HEARTH PRODUCTS
KITS AND ACCESSORIES
775,237M
Rev. A, 12/2007
INSTALLATION INSTRUCTIONS FOR CONVERTING FROM PROPANE GAS (LP) TO
NATURAL GAS (NG). FOR USE WITH THE MEDINA™ DIRECT VENT GAS FIREPLACE INSERTS
KIT CONTENTS (See Figure 1):
1 ea. Robertshaw NG Regulator Kit (A)
1 ea. #41 NG main burner orifice (25,000 BTU’s) (B)
1 ea. Instruction Sheet
MEDINA™ GAS CONVERSION INSTRUCTIONS LP TO NG
CAT. NO. H5465, MODEL MED-CK-LP TO NG
AVERTISSEMENT
Cet équipement de conversion sera installé par une
agence qualifiée de service conformément aux instruc-
TOOLS NEEDED (See Figure 2):
tions du fabricant et toutes exigences et codes applicables de l'autorisés avoir la juridiction. Si l'information
5/32” Allen Wrench Or T-Handle Wrench
Phillips Screwdriver
1/2” Open End Wrench
7/16” Open End Wrench
dans cette instruction n'est pas suivie exactement, un
feu, explosion ou production de protoxyde de carbone
peut résulter le dommages causer de propriété, perte
ou blessure personnelle de vie. L'agence qualifiée de
service est esponsable de l'installation propre de cet
Figure 1 - Kit Contents
équipment. L'installation n'est pas propre et compléte
jusqu'à l'opération de l'appareil converti est chéque
A
B
suivant les critères établis dans les instructions de
propriétaire provisionnées avec l'équipement.
Figure 2 - Tools Needed
Fig. 2
WARNING
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of
life. The qualified service agency performing this
installation is responsible for the proper installation of
this kit and assumes responsibility for this conversion.
The installation is not proper and complete until the
operation of the converted appliance is checked as
specified in the manufacturers instructions supplied
with the kit.
IMPORTANT CANADA
The conversion shall be carried out in accordance with
the requirements of the provincial authorities having
jurisdiction and in accordance with the requirements
of the CAN/CSA B149.1 Installation code.
IMPORTANT LE CANADA SEULEMENT
La conversion devra être effectuée conformément
aux recommandations des autorités provinciales
ayant juridiction et conformément aux exigences
du code d'installation CAN/CSA B149.1 .
IMPORTANT
The burner orifices provided in this kit are only for
use at elevations of 0 to 2,000 feet (610 M) in the
USA and 0 to 4,500 feet (0-1372 M) in Canada. At
higher elevations the BTU input must be de-rated
by 4% for every 1,000 feet (305 M) to maintain
the proper ratio of gas to air. If the installer must
convert the unit to adjust for varying altitudes, a
deration information sticker must be filled out by the
installer and adhered to the appliance at the time
of the conversion. Contact your local gas supplier
for deration requirements for your area.
1
READ ALL THE STEPS BEFORE STARTING THE CONVERSION.
INSTALLER NOTICE: THESE INSTRUCTIONS MUST BE LEFT WITH
THE APPLIANCE.
This kit contains components required to convert this appliance
from using Propane Gas to using Natural Gas as the only fuel.
All of these components must be replaced in order for the unit to
operate safely on Natural Gas.
When installing gas components use pipe joint compound or
Teflon tape on all pipe fittings before installing (ensure propane
resistant compounds are used, do not use pipe joint compounds
on flare fittings).
INSTALLATION INSTRUCTIONS
Step 1. TURN OFF THE GAS SUPPLY TO THE APPLIANCE.
Step 2. Using a phillips screwdriver, remove and discard the two pressure
regulator mounting screws (see Figure 3). Remove the pressure
regulator and rubber gasket. Discard all removed components.
Install the new regulator. Ensure the rubber gasket on the back
of the pressure regulator is properly positioned when installing
the new pressure regulator using the new screws supplied with
this kit. Locate the label provided in the regulator kit. Write in
the required information, then affix it to the valve.
Gas Valve
(located in control compartment below firebox)
Air shutter
screw
Figure 4A
Burner
Log rack and burner screws
Lift Out Burner
Regulator
Remove These
Screws
Fill out & affix label from
regulator kit to valve
Figure 3 - Replace Regulator on Valve
Step 3. Remove the glass door by releasing the two upper spring latches,
and lifting up, out of the lower latches (see Page 18 of the Instal-
lation and Operation Manual). Carefully remove the logs. Exercise
care so as not to break the logs. Set aside in a safe place.
Step 4. Remove log rack by first removing the two 5/32” allen head
screws. Note: Screws secure log rack and front of burner. After
screws are removed you can pull the lock rack straight out making sure it’s held high enough to clear over the pilot assembly.
See Figure 4A.
Step 5. Remove burner by shifting it to the right until it releases from
air shutter. Air shutter may need to be shifted to the left before
burner will release. Remove 5/32” air shutter screw before moving air shutter. See Figures 4A and 4B.
Burner
Figure 4B
Step 6. Using a 7/16” open-end wrench, loosen the stem of pilot hood
assembly with a 1/4 turn counterclockwise (see Figures 5 & 6).
Pilot Hood
Pilot Stem
7/16” End Wrench
Figure 5
2
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.