Lennox LSM40EN-PV, LSM45EN-PV User Manual

CARE AND OPERATION INSTRUCTIONS
F
R
E
E
See Page 2 For Details
SAFETY
GUARD
PROTECTS AGAINST BURNS
AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death.
WARNING /AVERTISSEMENT/AVISO
• HOT GLASS WILL CAUSE BURNS.
• DO NOT TOUCH GLASS UNTIL COOLED.
• NEVER ALLOW CHILDREN TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
P/N 506025-02 Rev. C 06/2011
This manual is one of a set of two supporting this product. Refer to P/N 506023-09 for Installation Instructions.
Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 506223-30.
WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . . . . 5
[EN FRANÇAIS] L’information de sûreté importante . . . . . . . . . . . . . . . 3–4
Apposition des mises en garde relatives à la sécurité d’utilisation . . . . 5
[EN ESPAÑOL] Información importante de seguridad . . . . . . . . . . . . . . 3–4
Colocación de advertencias de seguridad en operación . . . . . . . . . . . . 5
Wait...
DON’T THROW IT AWAY!
This manual contains
important operating
and safety
information.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil. CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
Montebello Power Vent DV Gas Fireplaces
MODELS
LSM40EN-PV LSM45EN-PV
US
OTL Report No. 116-F-22-5
ELECTRONIC:
Portland
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
Thank you for your purchase. We appreciate your business! Please carefully read and follow all instructions in this manual.
Pay special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
Safety and
Your Fireplace
All parts of your Lennox
FREE
severe burns and injuries by preventing direct contact
To receive your FREE SAFETY GUARD, call 1-800-786-7976
or visit www.lennox.com
SAFETY GUARD
The Lennox® SAFETY GUARD protects against
with the front glass surface of your fireplace.
(Lennox Hearth Products / Owner Resources)
OFFER
TABLE OF CONTENTS
Safety and Your Fireplace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . . . . . . . . 5
Appliance Installation, Service, and Maintenance Notices . . . . . . . . . . . . . 6
Appliance Operation Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
BTU Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Gas Pressure Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Orifice Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Burn-In Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operation and Care of Your Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Appliance Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Gas Controls / Control Compartment Access . . . . . . . . . . . . . . . . . . . . . 8
Purge Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Lighting Electronic Appliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Power Vent Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Variable Flame Height Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Front Glass Enclosure Panel Removal/Installation . . . . . . . . . . . . . . . . . . 11
Log, Volcanic Stone, and Glowing Ember Placement . . .. . . .. . . . . . . . . . 12
Burner Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Flame Appearance and Sooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Air Shutter Adjustment Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Burner Air Shutter Adjustment Procedure . . . . . . . . . . . . . . . . . . . . . . 15
Electronic Appliance Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Ordering Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Product Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Accessory Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Operating (Lighting) Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Troubleshooting Guide: Electronic Gas Control System . . . . . . . . . . . . . . 22
Troubleshooting Guide: Power Vent System . . . . . . . . . . . . . . . . . . . . . . 23
Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Replacement Parts Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Power Vent Replacement Parts and Illustrations . . . . . . . . . . . . . . . . . . . . 26
Hearth Products fireplace
get EXTREMELY HOT!
To prevent severe burns and injuries, install
a screen or physical barrier to prevent direct contact with the glass.
To order a FREE Lennox® SAFETY GUARD for your fireplace, see details at left.
Follow the safety instructions below
and be sure everyone in your household understands this burn hazard:
•The surfaces on your fireplace get EXTREMELY HOT!
•The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched.
•Keep children away from an operating fireplace. Closely supervise children in any room where a fireplace is operating to prevent contact with glass.
•Keep clothing, furniture, gasoline, and other flammable liquids away from the fireplace.
•Even after the gas is turned off, fireplace surfaces remain extremely hot.
Be sure to attach the enclosed Safety-in-
Operation Warnings where you turn on your
fireplace, to help remind everyone of the dangers associated with high temperatures (see Page 5).
Read Important Safety Information on
Page 4.
2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
[FRENCH] [SPANISH]
La sécurité et
votre foyer
Toutes les parties de votre foyer
Lennox Hearth Products deviennent
EXTRÊMEMENT CHAUDES !
Afin d'éviter de vous brûler gravement ou de
vous blesser, installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre.
Pour commander un PANNEAU DE PROTECTION Lennox® GRATUIT pour votre foyer, consultez les détails dans la partie gauche.
Suivez les instructions de sécurité ci-dessous
et veillez à ce que tous les membres de votre famille soient conscients du danger de brûlure encouru :
•Les surfaces de votre foyer deviennent EXTRÊMEMENT CHAUDES !
•La vitre située à l'avant du foyer atteint des températures EXTRÊMEMENT ÉLEVÉES et peut causer de graves blessures en cas de contact.
•Tenez les enfants à l'écart du foyer lorsqu'il fonctionne. Surveillez attentivement les enfants dans les pièces où un foyer est utilisé afin d'éviter qu'ils ne soient en contact avec la vitre.
•Tenez tous les vêtements, les meubles, l'essence et tout autre liquide inflammable à l'écart du foyer.
•Même après fermeture du gaz, les surfaces du foyer restent extrêmement chaudes.
Seguridad y
su chimenea
¡Todas las partes de la chimenea
Lennox Hearth Products se ponen
MUY CALIENTES!
Instale una malla o barrera física para evitar
el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves.
Ver los detalles a la izquierda para ordenar un Lennox® SAFETY GUARD GRATIS para su chimenea.
Siga las instrucciones de seguridad a
continuación y asegúrese de que todos en su hogar sepan acerca de este peligro de quemadura:
•¡Las superficies de la chimenea se ponen MUY CALIENTES!
•El vidrio delante de la chimenea alcanza temperaturas EXTREMADAMENTE ALTAS y puede causar quemaduras graves si se toca.
•Mantenga a los niños alejados de la chimenea en funcionamiento. Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio.
•Mantenga la ropa, mobiliario, gasolina y otros líquidos inflamables alejados de la chimenea.
•Aún después de haber apagado el gas, las superficies de la chimenea permanecen extremadamente calientes.
Veillez à coller les Étiquettes de mise en garde
relatives à la sécurité d'utilisation à l'endroit
où vous utilisez le foyer, pour rappeler à tous les utilisateurs les dangers liés aux températures élevées (voir Page 5).
Lisez la section Informations importantes
relatives à la sécurité, Page 4.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Asegúrese de colocar las Etiquetas de
advertencia de seguridad de operación en
el lugar donde enciende la chimenea, para que todos recuerden los peligros asociados con las altas temperaturas (ver la página 5).
Lea la Información importante de seguridad
en la página 4.
3
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
Important Safety Information
1. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person .
2. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
3. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
4. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
5. Clothing or other flammable material should not be placed on or near the appliance.
6. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children, and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children, and other at-risk individuals out of the room and away from hot surfaces.
7. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
8. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. See maintenance instructions on Page 10.
L'information de sûreté importante
1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé. Confiez le remplacement du panneau à un technicien agréé
2. Ne pas utiliser cet appareil s’il a été plongé, même partiellement, dans l’eau. Appeler un technicien qualifié pour inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été plongée dans l’eau.
3. En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de circulation et loin du mobilier et des tentures.
4. Les enfants et les adultes devraient être informés des dangers que posent les températures de surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
5. On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
6. Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité ; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
7. Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
8. L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité importante de poussière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les conduits de circulation d’air de l’appareil soient tenus propres. Voyez les instructions d’entretien à la Page 10.
[SPANISH]
Información importante de seguridad
1. ADVERTENCIA: No opere el artefacto con el frente de vidrio quitado, agrietado o roto. Un técnico de servicio licenciado o capacitado debe reemplazar el vidrio.
2. No use este artefacto si alguna de sus partes ha estado bajo agua. Llame de inmediato a un técnico de servicio calificado para que inspeccione el artefacto y reemplace cualquier parte del sistema de control y cualquier control de gas que haya estado bajo agua.
3. Debido a las altas temperaturas, el artefacto debe situarse fuera de las áreas de tráfico y lejos del mobiliario y cortinas.
4. Se debe alertar a los niños y adultos sobre los peligros de las altas temperaturas en la superficie y que se mantengan alejados para evitar quemaduras o ignición de la ropa.
5. No debe colocarse ropa u otros materiales inflamables
4
sobre y cerca del artefacto.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
6. Se debe supervisar de cerca a los niños cuando estén en el mismo cuarto que el artefacto. Los niños pequeños, los jóvenes y otras personas pueden ser susceptibles a quemaduras por contacto accidental. Se recomienda instalar una barrera física si hay personas en riesgo en la casa. Para restringir el acceso a una chimenea o estufa, instale una puerta de seguridad ajustable para mantener a los niños pequeños, jóvenes y otras personas en riesgo fuera del cuarto y lejos de las superficies calientes.
7. Cualquier malla o resguardo de seguridad quitado para dar servicio a un artefacto, debe reinstalarse antes de operar el artefacto.
8. Una persona de servicio competente debe realizar la instalación y reparación. Una persona de servicio profesional debe inspeccionar el artefacto antes de usar al menos una vez por año. Se puede requerir limpieza más frecuente debido a la pelusa excesiva del alfombrado, del material de cobijas, etc. Es imprescindible mantener limpios los compartimientos de control, los quemadores y los pasajes de circulación del aire del artefacto. Ver las instrucciones de mantenimiento en la página 10.
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS
ATTACHING SAFETY-IN-OPERATION WARNINGS
Your fireplace has been furnished with safety instruc­tion labels that are to be affixed to the operation and control point of the fireplace. A safety instruction label should be affixed to the wall switch plate where the fireplace is turned on and off (See Figure A) or wall thermostat (See Figure B) and if used on the remote control handheld transmitter (Figure C). The warnings should already have been put in place when the fireplace initial set-up was completed. If they are not affixed at these spots, locate the multi-lingual adhesive labels provided with these instructions and proceed as follows:
1. Locate the wall switch or wall thermostat that controls the fireplace (verify the switch operates the fireplace by turning it on and off). Clean the wall switch plate or wall thermostat thoroughly to remove any dust and oils. Affix the label to the surface of the plate of the wall switch that controls the fireplace (Figure A) or the wall thermostat (Figure B). Choose the language primarily spoken in the home.
2. If a remote control is used to control the fireplace, locate the transmitter and clean it thoroughly to remove any dust and oils. Affix the label to the surface of handheld transmitter (Figure C). Choose the language primarily spoken in the home.
3. If you are unable to locate the labels, please call Lennox Hearth Products or your nearest Lennox Hearth Products dealer to receive additional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Note: English is red text on clear label. French and Spanish are white text on black label.
APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION
Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité doit être collée sur la plaque de l’interrupteur contrôlant l’allumage du foyer (voir Figure A) ou sur le thermostat mural (voir Figure B) et, le cas échéant, sur le boîtier de la télé- commande (Figure C). Les mises en garde auraient dû être collées au moment de l’installation initiale du foyer. Si ce n’est pas le cas, prenez les étiquettes adhésives multilingues fournies avec ces instructions et procédez comme suit:
1. Repérez l’interrupteur ou le thermostat mural qui contrôle le foyer (vérifiez que l’interrupteur contrôle le fonctionnement du foyer en le faisant basculer de Marche à Arrêt, et vice-versa). Nettoyez soigneusement la plaque murale de l’interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur la surface de la plaque de l’interrupteur mural qui contrôle le foyer (Figure A) ou du thermostat mural (Figure B). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire.
2. Si une télécommande est utilisée pour contrôler le foyer, nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur le boîtier de la télécommande (Figure C). Choisissez la langue qui est principale- ment parlée dans la résidence du propriétaire.
3. Si vous ne trouvez pas les étiquettes, veuillez appeler Lennox Hearth Products ou votre distribu­teur Lennox Hearth Products local pour recevoir gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Remarque : Le texte anglais est rouge sur un support transparent. Le texte français et espagnol est blanc sur un support noir.
COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD EN OPERACIÓN
Su chimenea incluye etiquetas de instrucciones de seguridad que deben colocarse en el punto de operación y control de la chimenea. Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared desde el cual se enciende y se apaga la chimenea
(ver la Figura A) o en el termostato de pared (ver la Figura B) y en el transmisor de control remoto (Figura C) si
se usa. Las advertencias ya deben haberse colocado cuando se completó la instalación inicial de la chimenea. Si no están colocadas en estos lugares, encuentre las etiquetas adhesivas multilingües proporcionadas con estas instrucciones y prosiga de la siguiente manera:
1. Identifique el interruptor o el termostato de pared que controla la chimenea (verifique que el interruptor opera la chimenea encendiéndola y apagándola). Limpie bien la placa del interruptor o el termostato de pared para quitar el polvo y aceite. Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea (Figura A) o en el termostato de pared (Figura B). Seleccione el idioma que más se habla en la casa.
2. Si se usa un control remoto para controlar la chimenea, encuentre el transmisor y límpielo bien para quitar el polvo y aceite. Pegue la etiqueta en la superficie del transmisor (Figura C). Seleccione el idioma que más se habla en la casa.
3. Si no puede encontrar las etiquetas, sírvase llamar a Lennox Hearth Products o al distribuidor de Lennox Hearth Products más cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas.
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Nota: La etiqueta en inglés es transparente con texto rojo. Las etiquetas en francés y español son negras con texto blanco.
SAFETY LABEL
DIAGRAMS
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
Figure A Figure B Figure C
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
DIAGRAMAS DE ETIQUETAS
DE SEGURIDAD
5
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES
IMPORTANT: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier.
Only trim kit(s) supplied by the manufac­turer shall be used in the installation of this appliance.
Draft relief openings must not be covered or blocked.
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
Any change to this appliance and/or its operating controls is dangerous. Improper installation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizzi­ness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly. Some people are more affected by carbon monoxide than others, including pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
APPLIANCE OPERATION NOTICES
Do not operate appliance with the glass front removed, cracked, or broken.
These fireplaces are vented gas appli­ances. Do not burn wood or other material in these appliances.
This appliance is only for use with the type of gas indicated on rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
Provide adequate clearances around air openings and adequate accessibility clearance for service and proper opera­tion. Never obstruct the front openings of the appliance.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
These fireplaces are designed as supple­mental heaters. Therefore, it is advisable to have an alternate primary heat source when installed in a dwelling.
WARRANTY INFORMATION
Your gas appliance is covered by a limited twenty-year warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu­ments for future reference.
Failure to comply with the installation and operating instructions provided will result in an improperly installed and operating appliance, voiding its warranty.
Do not attempt to alter or modify the construction of the appliance or its components. Any modification or alteration may void the warranty, certification, and listings of this unit.
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
The vent termination is hot while in operation and for a period of time fol­lowing the use of the fireplace. Young children should be carefully supervised when they are in the same area as a hot termination
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
GENERAL INFORMATION
The fireplace models covered in this manual are direct-vent, sealed combustion gas fireplaces designed for residential application. Direct­vent appliances operate with the combustion chamber completely isolated from the indoor environment.
All air for combustion is brought in from the outside and exhaust gases are vented through the same direct-vent, co-axial (intake/exhaust) vent system.
These electronic appliances are designed to operate on natural gas or propane and have an electronic intermittent pilot ignition system. External 120 Volt AC electrical power is is required to operate these units.
These appliances comply with National Safety Standards and are tested and listed by OMNI­Test Laboratories, Inc. (Report No. 116-F-22-5) to ANSI Z21.50b in the USA.
The Installation must conform to local codes or, in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The appliance, when installed, must
be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition.
BTU Input
Electronic models come standard with a manually-modulated gas valve; flame appear­ance and heat output can be controlled at the gas valve. The BTU Input for these appliances is shown in Table 1.
Input (BTU/HR) - All Models
Model No. Input (BTU/Hr)
Natural Gas
LSM40EN-PV 32,500 to 42,000 LSM45EN-PV 32,500 to 42,000
Propane Gas (if field converted)
LSM40EN-PV field-
converted to propane
LSM45EN-PV field-
converted to propane
30,000 to 40,500
30,000 to 40,500
Table 1
Gas Pressure Requirements - All Models
Tables 2 and 3 show the appliances' gas pres- sure requirements.
Inlet Gas Supply Pressure
(all models)
Fuel # Minimum Maximum
Natural Gas
Propane
5.5" WC
(1.37 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 2
Manifold Gas Supply Pressure
(all models)
Fuel # Low High
Natural
Gas
Propane
(Lo) 2.2" WC
(.55 kPa)
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 3.5" WC
(.87 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 3
Test gauge connections are provided on the front of the gas control valve, identified IN for the inlet and OUT for the manifold side (see Figure 3 on Page 6). The control valve has a 3/8" (10 mm) NPT thread inlet and outlet side of the valve.
These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
These appliances and their individual shut-off valves must be disconnected from the gas supply piping system dur­ing any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa).
Orifice Sizes - Sea Level to High Altitude
(All Models): These appliances are tested and
approved for installations at elevations of 0-2000 feet (0-610 meters) above sea level using the standard burner orifice sizes (marked with an asterisk [*] in Table 4).
At the time of installation, it must be determined if the appliance needs to be derated. Contact your local gas supplier for deration requirements for your area.
Burner Orifice Size
Elevation 0-2000 ft. (0-610m)
Model Natural Gas Propane Gas
LSM40-PV
LSM45-PV
Table 4
Deration
At higher elevations, the amount of BTU fuel value delivered must be reduced by either using gas that has been derated by the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1 - latest edition.
.125" (1/8") *
H7924•
.125" (1/8") *
H7924•
* Standard size installed at factory
•Part/Cat.Number
.073" (#49)
H7936
.073" (#49)
H7936
Burn-in Period
During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the burn-in period may take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.
NOTICE: A white film may develop
on the glass enclosure panel during the first few fires as part of the burn-in process.
The first few times you use the fireplace, clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED); otherwise, the white film will bake onto the glass and become difficult to remove.
See glass cleaning instructions on Page 8.
7
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
OPERATION AND CARE OF YOUR APPLIANCE
WARNING
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trou­vent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
Gas Controls / Control Compartment Access
The gas controls can be found on the right hand side of the appliance as shown in Figure 1.
The standard controls for appliance operation are located behind the panel on the right side as shown in Figure 1. Optional control switches are also available (see Page 15 - remote wall switch, remote control or wall thermostat).
Right Side
Modesty Panel
Access Plate
Hi-Lo
Extension Knob
Gas Valve
Appliance Operation
To light the appliance refer to the detailed lighting instructions (see Pages 17 and 18). The appli- ance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
These appliance are fitted with an ON/OFF rocker switch for appliance ON/OFF control. See Figure 1 for its location. Once the pilot is lit, the ON/ OFF rocker switch will control the appliance ON/ OFF operation. To operate: Toggle the switch between its ON and OFF positions.
If your appliance is equipped with an optional remote switch kit, wall switch, remote control or wall thermostat, the appliance main burner may be turned on and off using the optional switch.
Note: To prevent excessive resistance in burner circuit (which can cause burner operation prob­lems), only one burner control switch should be wired to valve.
PURGE CYCLE
This is a power vented fireplace that requires household electrical power to operate. It will not operate during a power failure. When the fireplace is turned off, the exhaust blower will continue to operate for approximately one to two minutes after shutdown to expel the exhaust gases from the venting system.
ON/OFF Switch
Control Compartment Access
Figure 1
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS • MONTEBELLO® POWER VENT DV GAS FIREPLACES (LSM40/45EN-PV) • CARE AND OPERATION INSTRUCTIONS
16.17
(411 mm)
15.92
(404 mm)
10.00
(254 mm)
(284 mm)
HI
LO
Lighting Electronic Appliances
To light electronic appliances refer to the detailed lighting instructions found on Page 17 of these instructions respectively. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
Electronic appliances are fitted with an ON/OFF rocker switch for appliance ON/OFF control. See Figure 1 for its location.
Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions.
POWER VENT OPERATING INSTRUCTIONS
Power Vent Control Sequences
Turn On
1. Turn On The Thermostat Or On/Off Switch.
2. Blower Should Start Immediately.
3. Igniter Starts Sparking And Pilot Will Light.
4. Burner Should Light After A Few Seconds.
5. Fireplace Should Run Continuously Until Thermostat Or On/Off Switch Is Turned Off.
Turn Off
1. Turn Off The Thermostat Or On/Off Switch.
2. Burner And Pilot Should Be Off Immediately.
3. Blower Will Continue To Run For About 90 Seconds And Then The Blower Will Stop.
Gas Supply Inlet
Inlet Pressure Gauge Port
Manifold Pressure Gauge Port
Gas Outlet to Burner
Hi / Lo Variable Flame Height Adjustment
Pilot Adjustment Screw
Figure 3 - SIT Electronic Gas Valve
Variable Flame Height Adjustment
These appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alternately, while the appliance is in operation. Use the extension knob (refer to Figure 1), to adjust the flame height as desired by sliding the knob over the variable flame adjustment knob located on the front of the valve (refer to Figures 1 and 3). Replace the extension knob back to the hanger after the adjustment.
15.92
(404 mm)
Figure 2 - Power Vent Specifications
13.50
(343 mm)
Top View
16.17
(411 mm)
Front View
11.19
10.00
Note: Dimensions Are In Inches (mm)
(254 mm)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9