Lennox LM018HI-100P232-1X, LM024CI-100P232-1X, LM018HO-100P232-1X, LM024HI-100P232-1X, LM024HO-100P232-1X Owner's Manual

...
Split Air Conditioner
Thank you for selecting LENNOX air conditioners.Please read this manual carefully before operation and keep it for further reference
.
OWNER'S MANUAL
LENNOX AIR CONDITIONERS
LM018CI-100P232-1X LM018CO-100P232-1X LM024CI-100P232-1X LM024CO-100P232-1X LM018HI-100P232-1X LM018HO-100P232-1X LM024HI-100P232-1X
LM009CI-100P232-1 LM009CO-100P232-1
LM024HO-100P232-1X
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from un­controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate­rial resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for envi­ronmental safe recycling.
Content
Operation Notices
Precautions............................................................................................................1
Parts Name............................................................................................................7
ScreenOperation Guide
Buttons on remote controller .................................................................................9
Introduction for icons on display screen ...............................................................9
Introduction for buttons on remote controller .......................................................10
Function introduction for combination buttons .....................................................13
Operation guide ...................................................................................................14
Replacement of batteries in remote controller .....................................................14
Emergency operation ..........................................................................................15
Maintenance
Clean and Maintenance.......................................................................................15
Malfunction
Malfunction analysis ............................................................................................18
Installation Notice
Installation dimension diagram ............................................................................22
Tools for installation .............................................................................................23
Selection of installation location ..........................................................................23
Requirements for electric connection ..................................................................24
Installation
Installation of indoor unit......................................................................................25
Installation of outdoor unit ...................................................................................30
Vacuum pumping .................................................................................................33
Leakage detection ...............................................................................................33
Check after installation ........................................................................................34
Test and operation
Test operation ......................................................................................................34
Attachment
.........................................................................35
Pipe expanding method
Configuration of connection pipe
.......................................................................................37
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
1
Precautions
WARNING
Do not connect air conditioner to multi-purpose socket.
This appliance can be used by children aged from 8
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
.
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
2
Precautions
WARNING
conditioner and disconnect power immediately, and then
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
3
Precautions
WARNING
note
the following table.Air switch should be included
Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only.
4
Precautions
WARNING
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
The indoor unit should be installed close to the wall.
reachable after finishing installation.
far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
WARNING
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
Select a location which is out of reach for children and
For the air conditioner with plug, the plug should be
Working temperature range
Indoor side DB/WB(℃) Outdoor side DB/WB(℃) Maximum cooling 32/23 43/26 Maximum heating 27/- 24/18
The operating temperature range (outdoor temperature) for cooling only unit is 18℃~43℃; for heat pump unit is -7℃~ 43℃.
For LM009CI-100P232-1, LM009CO-100P232-1
NOTICE:
Precautions
5
6
For LM018CI-100P232-1X, LM018CO-100P232-1X, LM018HI-100P232-1X
Indoor side DB/WB(℃) Outdoor side DB/WB(℃)
Maximum cooling 32/23 48/30
Maximum heating 27/- 24/18
The operating temperature range (outdoor temperature) for cooling only unit is 18℃~ 48℃; for heat pump unit is -7℃~ 48℃.
NOTICE:
Precautions
LM018HO-100P232-1X,LM024CI-100P232-1X, LM024CO-100P232-1X LM024HI-100P232-1X, LM024HO-100P232-1X
7
(Display content or position may be di
fferent from above
graphics, please refer to actual products)
Parts Name
Indoor Unit
Outdoor Unit
air inlet panel
aux.button
horizontal louver air outlet
remote control
air inlet
Connection wire
air outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
Parts Name
Display content or position may be different from above graphics, please refer to actual products.
Display
W R G
temp. indicator
display
receiver window
W R O
temp. indicator
display
receiver window
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
For some model:
For some model:
For some model:
For some model:
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
G
W
R
Power LED color indicator: Green-status-ON. Red-status-OFF.
Mode LED color indicator: White-W-Cool Mode-
Red-R-Heat Mode-
Green-G-Dry Mode-
O
W
R
Power LED color indicator: Green-status-ON. Red-status-OFF.
Mode LED color indicator: White-W-Cool Mode-
Red-R-Heat Mode­Orange-O-Dry Mode-
(only for heating model)
(only for heating model)
8
9
Buttons on remote controller
Introduction for icons on display screen
1
14
3
1
13
2
2
5
4
6 7
8
11 12
13
9
14 15
ON/OFF button
▲ button
3
FAN button
SWING button
TIMER OFF button
TURBO button
10
TEMP button
I FEEL button
button
CLOCK button TIMER ON button SLEEP button
Send signal Turbo mode
8 heating function
Set temperature
Set time TIMER ON /
TIMER OFF Child lock
Up & down swing
Set fan speed
ventilation operation
Light
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Clock
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
I feel
6 9
8
12 15
4 7
10
5
11
X-FAN button
/
MODE button
button
X-fan mode
health function
10
Introduction for buttons on remote controller
Note:
After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator). After that, you can operate the air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the signal icon " " on the display of remote controller will blink once and the air conditioner will give out a “de” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the corre­ sponding icons will be displayed on the display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
ON/OFF button
▲ button
1
2
Press this button to turn on the unit. Press this button again to turn off the unit.
Press this button to increase set temperature. Holding it down above 2 seconds rapidly increases set temperature. In AUTO mode, set temperature is not adjustable.
MODE button
3
Each time you press this button,a mode is selected in a sequence that goes from AUTO, COOL, DRY, FAN, and HEAT *, as the following:
SWING button
4
Press this button to set up & down swing angle, which circularly changes as below:
button
5
Press this button to decrease set temperature. Holding it down above 2 seconds rapidly
decreases set temperature. In AUTO mode, set temperature is not adjustable.
After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will not be displayed on the LCD, and the unit will automatically select the suitable opera­tion mode in accordance with the room temperature to make indoor room comfortable.
AUTO COOL DRY FAN
HEAT
*
* Note: Only for models with heating function.
OFF
This remote controller is universal. If any command , or is sent out, the unit will carry out the command as
indicates the guide louver swings as:
Loading...
+ 28 hidden pages