HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
OTL Report No. 116-F-18-05
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO­SION MAY RESULT CAUSING PROPERTY DAM­AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin­ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
B-VENT ELITE
B-VENTED GAS APPLIANCES P/N 504,138M REV. H 03/2007
®
SERIES
MODELS
Millivolt Models Electronic Models
LBV-3824MN LBV-3824EN LBV-3824MP LBV-3824EP LBV-3824MN-H LBV-3824EN-H LBV-3824MP-H LBV-3824EP-H LBV-4324MN LBV-4324EN LBV-4324MP LBV-4324EP LBV-4324MN-H LBV-4324EN-H LBV-4324MP-H LBV-4324EP-H
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence ni d'autre vaperurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le batiment où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appeflez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié installer, agence de service ou le fournisseur de gaz.
1
Page 2
CONGRATULATIONS!
In selecting this LENNOX B-vented gas appliance you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product.
TABLE OF CONTENTS
Introduction..................................... page 2
General Information......................... page 2
Operation/Care of Your Appliance.... page 3
Damper & Combustion Air Controls page 4
Manual Limit Switch........................ page 5
Maintenance .................................... page 5
Burner Adjustments......................... page 5
Flame Appearance and Sooting ....... page 5
Maintenance Schedule..................... page 6
Adjustment ...................................... page 7
Millivolt Appliance Checkout............ page 7
Electronic Appliance Checkout......... page 7
Log and Rockwool Placement ......... page 7
Wiring Diagrams.............................. page 9
Warranty.......................................... page 9
Product Reference Information ....... page 9
Replacement Parts .......................... page 9
Lighting Instructions – Millivolt....... page 10
Lighting Instructions – Electronic.... page 12
Troubleshooting Guide – Millivolt ..... page 14
Troubleshooting Guide – Electronic .. page 15
Accessory Components................... page 16
Replacement Parts List..................... page 17
INTRODUCTION
The millivolt appliances are designed to oper­ate on either natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation.
The electronic appliances are designed to op­erate on either natural or propane gas. An electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these units.
These appliances comply with National Safety Standards and are tested and listed by Omni­Test Laboratories (Report No. 116-F-18-5) to ANSI Z21.50b-2002 (in Canada, CSA-2.22b-
2002), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Elec­trical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
GENERAL INFORMATION
Note: Installation and repair should be per­formed by a qualified service person. The appli­ance should be inspected annually by a quali­fied professional service technician. More fre­quent inspections and cleanings may be re­quired due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les in­structions d'installation et d'utilisation qui accompagnent l'apareil.
Provide adequate clearances around air open­ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
Due to high temperatures the appliance should be located out of traffic and away from furni­ture and draperies. Locate furniture and win­dow coverings accordingly.
WARNING: THESE FIREPLACES ARE VENTED DECORATIVE GAS APPLI­ANCES. DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will degrade the performance of this system and may be dan­gerous.
Input of appliances are 45,000 and 50,000 BTU/ HR for LBV-3824 and LBV-4324 respectively.
Gas Orifice Size
Type Elevation
LBV-3824
LBV-4324
Nominal operating pressures for the manifold side of the gas control system are; 3.5 inches water column (6.54 MmHg) for natural gas models and 10 inches water column (18.69 MmHg) for propane gas models.
Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water.
Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'lau.
Millivolt appliances may be fitted at time of manufacture with either a Honeywell millivolt gas control valve or as SIT millivolt gas control valve. Both valves have been tested with and approved for use with these appliances and are listed accordingly.
Natural
0.125 in.
#30
Propane
#48
#47
0 - 4500' (0 - 1370 m)
0 - 4500' (0 - 1370 m)
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 3
Test gage connections are provided on the
Refractory Access Panel
SIT Valve Shown
Gas Controls On Valve
front of the millivolt gas control valves (identi­fied OUT for the manifold side and IN for inlet pressure side for both SIT and Honeywell equipped appliances. A ¹⁄₈" NPT test gage connection is provided on the electronic gas control valve adjacent to the outlet to the main burner.
Minimum inlet gas pressure to the appliance is
5.0 inches water column (9.5 MmHg) for natural gas and 11 inches water column (20.55 MmHg) for propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to the appliance is 10.5 inches water column (19.95 MmHg) for natural gas and 13.0 inches water column (24.25 MmHg) for propane.
The appliance must be isolated from the gas supply piping system (by closing its individual manual shut-off valve) during any pressure test­ing of the gas supply piping system at test pressures equal to or less than ¹⁄₂ psig (3.5 kPa).
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ¹⁄₂ psig (3.5 kPa).
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN­STRUCTIONS PROVIDED IN THIS DOCU­MENT WILL RESULT IN AN IMPROP­ERLY INSTALLED AND OPERATING AP­PLIANCE, VOIDING ITS WARRANTY. ANY CHANGE TO THIS APPLIANCE AND/ OR ITS OPERATING CONTROLS IS DAN­GEROUS. IMPROPER INSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERIOUS INJURY OR DEATH FORM FIRE, BURNS, EXPLOSION OR CARBON MON­OXIDE POISONING.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be op­erating correctly.
WARNING: B-VENT APPLIANCES ARE NOT DESIGNED TO OPERATE IN NEGATIVELY PRESSURED ENVIRONMENTS (PRES­SURE WITHIN THE HOME IS LESS THAN PRESSURES OUTSIDE). SIGNIFICANT NEGATIVELY PRESSURED ENVIRON­MENTS CAUSED BY WEATHER, HOME DESIGN, OR OTHER DEVICES MAY IM­PACT THE OPERATION OF THESE APPLI­ANCES. NEGATIVE PRESSURES MAY RESULT IN POOR FLAME APPEARANCE, SOOTING, DAMAGE TO PROPERTY AND/ OR SEVERE PERSONAL INJURY. DO NOT OPERATE THESE APPLIANCES IN NEGA­TIVELY PRESSURED ENVIRONMENTS.
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE­FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES ENFANTS. GARDER LES VÊTEMENTS, LES MEUBLES, L'ESSENCE OU AUTRES LIQUIDES À VAPEUR INFLAMMABLES LIN DE L'APPAREIL.
OPERATION AND CARE OF YOUR APPLIANCE
1. Appliance operation may be controlled
through a remotely located optional wall switch. Separate switches may provide independent control for the remote controlled fireplace op­eration (optional equipment). In lieu of remote or remote wall switch operation, the appliance must be operated directly through the controls located on the front of the valve located within the control compartment under the removable refractory access panel,
Operation of millivolt and electronic gas con­trol systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance.
Figure 1
ment below the lower refractory panel.
to access the gas control compart-
Figure 1
.
Refer to
Figure 1
Millivolt appliances will be fitted with one of the two gas control valves shown in
on page 4
tems will be fitted with the electronic valve shown in yourself with the differing controls for the valve your appliance uses.
To light millivolt appliances refer to the de­tailed lighting instructions found in both En­glish and French on pages 10 and 11 of these instructions respectively. Millivolt and elec-
tronic appliance lighting instructions may also be found on the pull out rating plate located within the gas control compartment.
Refer to used with your appliance.
If your appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control. If the appliance is not equipped with a wall or remote control, the main burner must be turned off and on with the gas control knob. Turn the knob counter-clockwise from the PILOT position to ON to light the main burner, and clockwise from ON to PILOT to turn off the main burner.
To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 12 and 13 of these instructions respectively. Millivolt and
electronic appliance lighting instructions may also be found on the pull out rating plate located within the gas control compartment.
If your appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turner on and off with the wall switch or remote control. If the appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with the gas control switch. Toggle the switch from ON to OFF to operate the main burner from ON to OFF.
. Appliances with electronic sys-
Figure 3 on page 4
Figure 2
for the spark ignitor location
Figure 2
. Familiarize
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
Page 4
T
O
L
I
P
N
O
T
O
it
L
I
P
O
F
F
IN OUT
SIT Millivolt Valve
Spark Ignitor
Honeywell Millivolt Valve
Gas Control Knob
Gas Control Knob
O
N
P
I
L
O
O
F
F
T
Figure 2
Electronic Gas Control Valve
P S I
IN
ON/OFF Switch
E IT N IG
OFF
ON
CONTROL
Figure 3
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is due to the burn-in of internal paints and lubricants used in the manufacturing process.
3. Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materi­als, etc. It is important that control compart­ments, burners and circulating air passage­ways of the appliance be kept clean.
4. Always turn off gas to the pilot (millivolt appliances) before cleaning. Before re-light­ing, refer to the lighting instructions in this manual. Instructions are also found on a pull­out panel located on the floor of the appliance.
5. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
TPTH TP TH
Spark Ignitor
6. Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution when using products with combustible vapors.
7. Clean the optional glass doors only when necessary. Wipe surface with clean, damp­ened, soft cloth. Follow with dry, soft towel as desired. Take care not to scratch the glass surface.
WARNING: DO NOT USE ABRASIVE CLEANERS. NEVER CLEAN THE GLASS WHEN IT IS HOT.
CAUTION: DO NOT ATTEMPT TO TOUCH THE DOORS WITH YOUR HANDS WHILE THE FIRE­PLACE IS IN USE. ALWAYS USE DOOR HANDLES. DOORS WILL BECOME VERY HOT WHEN FIREPLACE IS IN USE.
WARNING: FIREPLACES EQUIPPED WITH OPTIONAL ACCESSORY DOORS SHOULD BE OPERATED ONLY WITH THE DOORS FULLY OPEN OR FULLY CLOSED
(FIGURE 4 ).
THIS APPLI­ANCE MAY ONLY BE FITTED WITH DOORS CERTIFIED FOR USE WITH THE APPLIANCE.
AVERTISSEMENT: POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÊES AVEC L'APPAREIL.
Fully Open or Fully Closed
Figure 4
DAMPER AND OUTSIDE AIR CONTROLS
This appliance is fitted with a manually con­trolled vent damper. The vent damper should be closed when the appliance is not in use to prevent cold air from entering the home through the venting system. The damper is controlled through the use of a control lever located within the appliance opening at the top center in front of the firebox lintel
(see Figure 5 )
. The control lever snaps into place at either extreme of its range of motion. When locked in position all the way to the right, the damper is open. When locked in position all the way to the left, the damper is closed.
The damper lever actuates a switch, (see wir­ing diagram) which will prevent the appliance main burner from lighting unless the damper is locked open. The appliance flue damper must always remain open when operating.
WARNING: DAMPER MUST BE IN OPEN POSITION WHEN APPLIANCE MAIN BURNER IS OPERATING.
AVERTISSEMENT: LE REGISTRE DOIT ÊTRE EN POSITION OUVERTE LORSQUE LE OU LES BRULEURS PRINCIPAUX DE L'APPEREIL FONCTIONNMENT.
Locked
Closed
Locked Open
Outside Air Actuator
Figure 5
4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 5
Many appliances are equipped when installed with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation. The shut-off lever for the outside air system is standard on all appliances but should not be operated if the complete system is not installed. Refer to complete outside air vent system is installed, the installer will remove the cover from the shut-off lever located in the left side of the firebox opening.
If your cover is not removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the pres­ence of the complete system. DO NOT assume that you have this system in place.
The hand operated shut-off lever is located in the left side of the fireplace opening behind the screen. To open, pull all the way. The outside air damper should be fully open when the fireplace is in use and completely closed when the fire­place is not being used. This will prevent outside cold air from entering the dwelling.
Figure 6
Figure 5
Detail A
. When the
WARNING: DO NOT OPERATE THE SHUTOFF LEVER UNLESS A COMPLETE OUTSIDE AIR VENT SYSTEM HAS BEEN INSTALLED WITH YOUR APPLIANCE.
MANUALLY-RESET BLOCKED FLUE SAFETY SWITCH
This appliance is equipped with a manually­reset blocked flue safety switch. Refer to
Figure 6
operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool, then reset the safety switch by pushing the red reset button.
This reset button is located on the back of the limit switch, between the wire terminals (
Detail A of Figure 21
The appliance should then relight and remain lit. If this does not occur, turn off the appli- ance and call a qualified service technician.
for its location. If during appliance
see
).
Wire Terminals
Maintenance
The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni­cian. Proper maintenance and use will require more frequent, less extensive inspections and servicing by the homeowner.
Generally, annual inspections should be per­formed by a qualified service technician. More frequent periodic inspections and cleanings should be performed by the homeowner. Any discrepancies discovered by the homeowner should result in a call to a qualified service technician to effect the repair or correction.
Refer to the maintenance schedule for mainte­nance tasks, procedures, periodicity and by whom they should be performed.
IMPORTANT: TURN OFF GAS AND ANY ELEC­TRICAL POWER BEFORE SERVICING THE APPLIANCE.
Burner Adjustments
Flame Appearance and Sooting
Proper flame appearance is a matter of taste. Generally most people prefer the warm glow of a yellow to orange flame. Appliances operated with air shutter openings that are too large, or with long vertical vent runs, will exhibit flames that are blue and transparent. These weak, blue and transparent flames are termed anemic.
Lintel Extension
Reset
Button
Manual Reset Limit Switch
Right Side Refractory Panel
If the air shutter opening is too small sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits form­ing on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termi­nation. Sooting is caused by incomplete com­bustion in the flames and a lack of combustion air entering the air shutter opening.
To achieve a warm yellow to orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
No smoke or soot should be present. Reposi­tion the log set if the flames impinge on any of them.
If sooting conditions exist, the air shutter opening on the main burner can be adjusted. Normally, the more offsets in the vent system, the greater the need for the air shutter to be opened further.
WARNING: AIR SHUTTER ADJUSTMENT SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
Page 6
Maintenance Schedule
Annually (Before the onset of the Burning Season)
Maintenance Task Accomplishing Person Procedure
Inspecting/Cleaning Burner, Logs and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Appliance Checkout
Replacing Rockwool Ember Materials
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services Technician
Inspect valve and ensure it is properly operat­ing. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area.
Refer to
Figure 8 on page 7
and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Refer to
Figure 9 on page 7.
Remove any surface build-up on pilot and burner assem­bly. Wipe the pilot nozzles, ignitor/flame rod and hood. Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca­tion of the vent components.
Perform the appropriate appliance checkout procedure detailed in this manual.
Remove old ember materials and vacuum the rockwool placement area. Place new rockwool as described in this document.
Periodically (After the Burning Season)
Maintenance Task Accomplishing Person Procedure
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Optional Glass Doors
Homeowner
Homeowner
Homeowner
Homeowner
Carefully remove logs, Rockwool and volcanic stone if used. Vacuum out interior of the firebox. Clean firebox walls and log grate. Replace logs, Rockwool and volcanic stone as detailed in this manual.
Refer to
Figure 8 on page 7
and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca­tion of the vent components.
Clean as necessary following the directions provided in this manual. DO NOT TOUCH OR
ATTEMPT TO CLEAN DOORS WHILE THEY ARE HOT.
6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 7
Adjustment
To adjust the flame, position the air shutter to the nominal setting
(see Figure 7 ).
Allow the burner to operate for at least 30 minutes. Observe the flame continuously.
If it appears weak or sooty as previously de­scribed, adjust the air shutter open or closed until desired effect is achieved.
Note: If the flame still appears anemic with the air shutter closed all the way (usually a result of lengthy vertical venting runs), turn off the appli­ance, turn off the gas supply, wait for the parts to cool and access the air shutter. The shutter is prevented from actually closing by a tab that is bent over into the opening. Remove this obstruc­tion by bending back. Reassemble and restart the appliance and after 24 minutes reobserve the flame. Adjust the air shutter as described.
Orifice
Air Shutter
Adjusting Set Screw
Figure 8
MILLIVOLT
Hood
Ignitor Rod
³⁄₈" Min (9 mm)
Burner Tube
Models Shutter Setting
LBV-3824
LBV-4324
Gas
Type
Natural 1/16" (1.59 mm)
Propane 3/16" (4.76 mm)
Natural Closed
Propane 1/4" (6.35 mm)
Factory Air
Inches (mm)
Figure 7
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge.
The top ³⁄₈" (9 mm) at the pilot generator (thermo- pile) should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports
(Figure 9 - Millivolt section)
Pilot Nozzels
Figure 9
Electronic Appliance Checkout
Light the burner, refer to the Lightilng Instruc­tions in this manual. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame rod as shown in
With proper care and maintenance, your appli-
.
Figure 9 - Electronic section.
ance will provide many years of enjoyment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox Dealer.
ELECTRONIC
3/8 To 1/2 Inch
(9 mm to 13 mm)
Proper Flame Adjustment
Pilot Nozzle
Logs and Rockwool (Glowing Embers) Placement
WARNING: LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF. HANDLE ONLY WHEN LOGS ARE COOL. TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL GRATE AND LOGS.
Ground Electrode
Flame Rod
Hot Surface Igniter
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
7
Page 8
WARNING: THIS APPLIANCE IS NOT MEANT TO BURN WOOD. ANY ATTEMPT TO DO SO COULD CAUSE IRREPARABLE DAMAGE TO YOUR APPLIANCE AND PROVE HAZARDOUS TO YOUR SAFETY.
WARNING: THE SIZE AND POSITION OF THE LOG SET WAS ENGINEERED TO GIVE YOUR APPLIANCE A SAFE, RELI­ABLE AND ATTRACTIVE FLAME PAT­TERN. ANY ATTEMPT TO USE A DIFFER­ENT LOG SET IN THE FIREPLACE WILL VOID THE WARRANTY AND WILL RE­SULT IN INCOMPLETE COMBUSTION, SOOTING, AND POOR FLAME QUALITY.
The logs are packaged within the firebox. The bag of rockwool is in the lower control compartment. Remove the rockwool from the packaging and tear into dime size pieces
(
Figure 10 on page 8
burner evenly. Do not use more than is necessary to cover the burner. When prop­erly positioned, the rockwool will unevenly cover approximately 85% of the burner with no appreciable gaps.
These appliances are equipped with a beauti­fully crafted five (5) piece ceramic fiber log set. The logs, shown in be positioned precisely as shown. Any modi­fication to the to the lay of these logs may result in sooting, property damage and injury or death.
All logs that engage pins have mating holes for pin engagement on their bottom sides. DO NOT force a hole into a log by engaging the pins where they are not intended to go. Apparent minor mis-alignment of the pins and holes can be eliminated by gently adjusting the position of the logs until the pins and holes easily mate.
). Spread across the
Figure 11 on page 8
, are to
Step 3. Place the "C" shaped main log (b) in position over the remaining log grate pin lo­cated at the far right near the front of the grate. The left end of the main log is to rest upon the "V" shaped front log with its back left edge butted up against the rear log (c).
Step 4. Position the top log (d) over the pins in the rear log and the main log. When prop­erly placed, the top will have its charred area to the left and the stubbed end toward the front.
Step 5. Position the rear top log (e) in the pocket formed over the left side of the rear log (c). The split face of the rear top log (e) must be facing forward, It's left end should be down fully against the log rack, and the crook (bend) in the log should break directly over the end of the rear log.
When properly positioned the logs should appear as illustrated in Logs must not impinge any of the flames.
Figures 11 and 12.
WARNING: IF USING THE OPTIONAL EMBER KIT, DO NOT PLACE ANY OF THE KIT COMPONENTS IN ANY LOCATION WHERE THEY MAY IMPINGE ON THE LOFTING FLAMES. GIVE CONSIDER­ATION TO THE POTENTIAL OF LATER INADVERTENT DISLOCATION OF THESE ELEMENTS AND ENSURE THEY ARE PLACED WHERE THEY MAY NOT FALL OR ROLL INTO AN IMPINGING LOCA­TION. FLAME IMPINGEMENT WILL RE­SULT IN SOOTING AND MAY CAUSE SERIOUS INJURY OR DEATH.
Figure 11
e.
d.
c.
a.
b.
7"
Step 1. To position the logs, begin by placing
the rear log (c) in position over the two pins located at the right center rear and right rear of the log grate
Step2. Position the front log (a) over the two pins found near the front left corner of the log grate. This log should be positioned with the split "V" notch to the front with the bulkier half of the "V" to the left.
8
(refer to Figure 11 ).
Figure 12
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 9
WIRING DIAGRAMS
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. Two Millivolt wiring diagrams are provided here, one each for both Honeywell and SIT equipped systems.
Electronic Wiring Diagram (Honeywell)
(Optional ON/OFF Switch Wiring)
1. If any of the original wire as supplied must be replaced,
1. it must be replaced with Type AWM 200°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
BK
BK
R
Gas Valve
CONTROL
BL
OPT FAN
Tab Intact
Green Ground Screw
WT
OPTIONAL
ON/OFF
SWITCH OR
WALL SWITCH
Factory Wired
IGNITER
W
BK
Neutral Side of Receptacle
BL
PILOT
ASSEMBLY
Green
B
R
BK
DAMPER
SWITCH
White
G
Black
Ta b
Broken Red Hot
Side of Receptacle
BK
Transf.
120 V.
24 V
LIMIT
SWITCH
G
r
120 VAC - Black
Junction Box
Optional
Accessory
Switch
Field Wired
SIT Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 200°C – 18 GA. wire.
Damper Switch
BK
BK
neerG-dnuo e
-
tihW
lartueN
Limit Switch
TP
TH
TP
TH
Thermopile
BK
*
WHT
BK
* For Wall Switch Attachment Only.
BK
Honeywell Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 200°C – 18 GA. wire.
WHT
TH
TPTH
TP
BK
TH
*
Limit
Switch
BK
BK
Damper
TH
TP
TP
Thermopile
* For Wall Switch Attachment Only.
Switch
BK
WARRANTY
Your gas appliance is covered by a limited twenty year warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other
REPLACEMENT PARTS
A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer.
Normally, all parts should be ordered through your Lennox distributor or dealer. Parts will be shipped at prevailing prices at time of order.
documents for future reference.
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your fireplace. Please contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox dealer, please call 1-800-9-LENNOX.
Your Fireplace's Model Number _______________________________________ Your Fireplace's Serial Number ________________________________________ The Date On Which Your Fireplace Was Installed __________________________ The Type of Gas Your Fireplace Uses ___________________________________ Your Dealer's Name_________________________________________________
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any questions concerning the installation or appli­cation of this system, please contact your dis­tributor, or Lennox directly:
LENNOX HEARTH PRODUCTS 1110 West Taft Avenue Orange, CA 92865
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9
Page 10
LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lighted with a piezo
ignitor. When lighting the pilot, follow these instructions exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Extinguish any open flame.
Open windows.
Do not light any appliance.
Do not touch any electrical switches.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Access the lower control compartment.
3. Turn remote wall switch to OFF.
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to OFF.
O
N
P
I
L
O
O
F
F
T
IN
TPTH TP TH
I
L
W
O
P
I
L
O
T
OUT
H
F
F
O
P
I
L
it
O
T
O
N
HONEYWELL
MILLIVOLT GAS VALVE
SIT MILLIVOLT GAS VALVE
Note: Knob cannot be turned from PILOT to OFF
unless the knob is pushed in slightly. Do not force.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbors phone.
If your gas supplier cannot be reached, call the fire depart-
ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow B in the safety information above on this page. If you do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise to PILOT.
8. Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (pushing the button) until pilot lights. Continue to hold the control knob in for about 1 ¹⁄₂ minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
SIT
MILLIVOLT PILOT
If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
If pilot will not stay lit after several tries, turn the control knob to “OFF” and call your service technician or gas supplier.
9. Turn gas control knob counterclockwise to ON.
10. Close lower control compartment.
10
TO TURN OFF GAS TO APPLIANCE
1. Turn remote wall switch OFF. The pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to OFF.
3. Access the lower control compartment.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
4. Depress gas control knob slightly and turn clockwise to OFF. Do not force.
5. Close lower control compartment.
Page 11
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT LALLUMAGE
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT SEN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Cet appareil est muni dune veilleuse qui doit être allumée avec un
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre exactement ces instructions.
B. AVANT LALLUMAGE: Assurez-vous que vous ne détectez aucune
odeur de gaz autour de lapareil ainsi que près du sol; certains gaz, étant plus lourds que lair, descendent au niveau du sol.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR DE GAZ:
Éteignez toute flamme visible.
Ouvrez les fenêtres.
Nallumez aucun appareil.
Ne touchez à aucun commutateur électrique.
Ne vous servez daucun téléphone dans votre édifice.
INSTRUCTIONS D'ALLUMAGE
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.
2. Ouvrez le compartiment de contrôle du bas.
3. Tournez linterrupteur mural à la position darrêt OFF”.
4. Assurez-vous que la soupape darrêt de la canalisation principale est
ouverte.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans le sens des aiguilles dune montre jusqu’à la position darrêt OFF.
O
N
P
I
L
O
O
F
F
T
IN
TPTH TP TH
I
L
W
O
P
I
L
O
T
OUT
H
F
F
O
P
I
L
it
O
T
O
N
Remarque: Il est impossible de tourner le bouton de PILOT” à OFF à
moins quil ne soit légèrement enfoncé. Ne le forcez pas.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des consignes de sécurité au verso de cette plaque. Si vous ne remarquez aucune odeur de gaz, passez à l’étape suivante.
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en sens inverse des aiguilles dune montre jusqu’à la position de veilleuse “PILOT”.
VANNE GAZ MILLIVOLT
HONEYWELL
VANNE GAZ
MILLIVOLT SIT
Appelez immédiatement votre compagnie de gaz en utilisant le téléphone du voisin.
Sil vous est impossible de contacter votre compagnie de gaz, appelez le service des incendies.
C. Nutilisez que votre main pour manipuler le bouton de réglage du gaz.
Nutilisez jamais doutils. Si le bouton refuse de tourner ou de bouger, nessayez pas de le réparer. Communiquez immédiatement avec un technicien de service qualifié. Toute tentative pour le forcer ou le réparer, risquerait de provoquer un incendie ou une explosion.
D. Ne vous servez pas de cet appareil si lun de ses éléments a été
immergé dans leau. Appelez immédiatement un technicien compétent pour faire inspecter lappareil et remplacer toute pièce du système de réglage ou commande du gaz qui a été sous leau.
8. Enfoncez le bouton de réglage jusquau fond et gardez-le enfoncé. Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le bouton) jusqu’à ce que la veilleuse senflamme. Continuez de tenir le bouton de réglage enfoncé pendant environ 90 secondes après lallumage de la veilleuse. Relâchez le bouton et il sortira subitement. La veilleuse devrait rester allumée. Si elle s’éteint, répétez les étapes 5 à 8 inclusivement.
• Si le bouton ne sort pas automatiquement après avoir été relâché, arrêtez immédiatement et téléphonez à votre technicien de service ou à votre fournisseur de gaz.
• Si la veilleuse refuse de rester allumée après plusieurs tentatives,
SIT
MILLIVOLT PILOT
tournez le bouton de réglage jusqu’à sa position d’arrêt “OFF” et téléphonez à votre technicien de service ou à votre fournisseur de gaz.
9. Tournez le bouton de réglage du gaz en sens inverse des aiguilles d’une montre jusqu’à sa position de marche “ON”.
10. Fermez le compartiment de contrôle du bas.
11. Au besoin, rebrancher lappareil au courant électrique et remettre
linterrupteur du brûleur principal à la position ON ou régler le thermostat à la température désirée.
12. Si lappareil ne fonctionne pas, suivre les instructions intituléesPour fermer le gaz qui alimente lappareil et appeler un
technicien ou le fournisseur de gaz.
POUR FERMER LE GAZ QUI ALIMENTE LAPPAREIL
1. Tournez linterrupteur mural à la position darrêt OFF. La veilleuse
restera allumée jusquau retour du service normal.
2. Pour une fermeture complète, tournez linterrupteur mural à la position d’arrêt “OFF”.
3. Ouvrez le compartiment de contrôle du bas.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans le sens des aiguilles d’une montre jusqu’à la position darrêt OFF. Ne forcez pas le bouton.
5. Fermez le compartiment de contrôle du bas.
11
Page 12
LIGHTING INSTRUCTIONS ELECTRONIC
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. When lighting the appliance, follow these instructions
exactly.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Extinguish any open flame.
Open windows.
Do not light any appliance.
Do not touch any electrical switches.
Do not use any phone in your building.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to OFF.
3. Open lower control compartment door.
4. Verify main line shut-off valve is open.
Immediately call your gas supplier from a neighbor’s phone.
If your gas supplier cannot be reached, call the fire department.
C. Use only your hand to turn the gas control lever. Never
use tools. If the lever will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
5. Turn the ON/OFF switch to OFF. Do not force.
6. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.
7. Turn the ON/OFF switch to ON. Do not force.
12
ON/OFF Switch
CONTROL
OFF
ON
IG N
IT E
R
Front View
IN
I S P
TO TURN OFF GAS TO APPLIANCE
1. For complete shut-down, turn remote wall switch to
OFF.
2. Open lower control compartment door.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
8. Turn ON all electrical power to appliance (remote wall switch).
9. Close lower control compartment door.
TO SHUT OFF
1. Turn off all electrical power to the appliance (remote wall
switch).
3. Turn the ON/OFF switch to OFF. Do not force.
4. Close the main line shut-off valve.
5. Close lower control compartment door.
Page 13
INSTRUCTIONS DALLUMAGE ELECTRONIC
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT LALLUMAGE
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT SEN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Lorsque vous allumez lappareil, suivez exactement ces instruc-
tions.
B. AVANT LALLUMAGE: Assurez-vous que vous ne détectez
aucune odeur de gaz autour de lapareil ainsi que près du sol; certains gaz, étant plus lourds que lair, descendent au niveau du sol.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR DE GAZ
Éteignez toute flamme visible.
Ouvrez les fenêtres.
Nallumez aucun appareil.
Ne touchez à aucun commutateur électrique.
Ne vous servez daucun téléphone dans votre édifice.
INSTRUCTIONS DALLUMAGE
1. ARRÊTEZ ! Lisez les consignes de sécurité au verso de cette
plaque.
2. Tournez linterrupteur mural à la position darrêt OFF”.
3. Ouvrez la porte du compartiment de contrôle du bas.
4. Assurez-vous que la soupape darrêt de la canalisation principale
est ouverte.
Appelez immédiatement votre compagnie de gaz en utilisant le téléphone du voisin.
Sil vous est impossible de contacter votre compagnie de gaz, appelez le service des incendies.
C. Nutilisez que votre main pour manipuler linterrupteur ON/
OFF de la valve à gaz. Nutilisez jamais doutils. Si linterrupteur ne bouge pas manuellement, nessayez pas de le réparer. Communiquez immèdiatement avec un technicien de service qualifié. Toute tentative pour forcer linterrupteur ou le réparer, risquerait de provoquer un incendie ou une explosion.
D. Ne vous servez pas de cet appareil si lun de ses éléments a été
immergé dans leau. Appelez immédiatement un technicien compétent pour faire inspecter lappareil et remplacer toute pièce du système de réglage ou commande du gaz qui a été sous leau.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez une odeur de gaz ARRÊTEZ ! Retournez au point B” des consignes de sécurité au verso de cette plaque. Si vous ne remarquez aucune odeur de gaz, passez à l’étape suivante.
7. Tournez la manette de réglage du gaz jusqu’à la position de marcheON. Ne la forcez pas.
8. Ouvrez le courant électrique (ON) qui alimente lappareil (interrupteur mural).
5. Tournez la manette de réglage du gaz à la position darrêt OFF”.
Interrupteur
ON/OFF
CONTROL
OFF
ON
IGNITER
Vue de face
IN
PSI
POUR FERMER LE GAZ QUI ALIMENTE LAPPAREIL
1. Pour une fermeture complète, tournez linterrupteur mural à la
position d’arrêt “OFF”.
2. Ouvrez la porte du compartiment de contrôle du bas.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9. Fermez la porte du compartiment de contrôle du bas.
10. Au besoin, rebrancher lapareil au courant électrique et
remettre linterrupteur principal du brûleur à la position ON ou régler le thermostat à la température désirée.
11. Si lappareil ne se met pas en marche, suivre les instructions
intitulées Pour fermer le gaz qui alimente lappareil et appeler un technicien ou le fournisseur de gaz.
POUR ÉTEINDRE LAPPAREIL
1. Coupez tout le courant électrique qui alimente lappareil (interrupteur
mural).
3. Tournez la manette de réglage du gaz à la position d’arrêt OFF. Ne la forcez pas.
4. Fermez la soupape darrêt de la canalisation principale.
5. Fermez la porte du compartiment de contrôle du bas.
13
Page 14
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM
Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in
the ON position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
1. Spark ignitor will not light
pilot after repeated triggering of ignitor button.
2. Pilot will not stay lit after carefully following the lighting instructions.
3. Pilot burning, no gas to burner, Valve knob ON, Wall Switch ON.
POSSIBLE CAUSES
A. Defective ignitor
(no spark at electrode).
B. Defective or misaligned electrode
at pilot (spark at electrode).
C. Gas supply pressure errant.
D. Pilot orifice plugged. A. Defective pilot generator
(thermogenerator).
A. Damper closed or Damper Switch
defective.
CORRECTIVE ACTIONSYMPTOM
Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace ignitor.
Using a match, light pilot. If pilot lights, turn off pilot and trigger the ignitor button again. If pilot lights, an improper gas mixture caused the bad lighting and a longer purge period is recommended. If pilot will not light – check gap at electrode and pilot - should be ³⁄₈" to have a strong spark. If gap measures ³⁄₈", replace pilot
Check inlet gas pressure. It should be within the limits as marked on the rating plate.
Clean or replace pilot orifice. Check pilot flame, it must impinge on thermogenerator
(Figure 9 on page 7)
mum flame impingement on thermogenerator. Ensure that the connection between the valve and thermogenerator are tight and secure.
Ensure damper control lever is locked in the open position, all the way to the right. If the damper control lever is locked in the open position troubleshoot through Steps B., C. and D. below. If the main burner will still not light, determine if the damper switch is defective and replace if necessary.
. Clean and/or adjust pilot for maxi-
(Figure 9 on page 7)
.
14
4. Frequent pilot/burner outage
problem.
B. Wall switch or wires defective.
C. Thermopile may not be generating
sufficient millivoltage.
D. Plugged burner orifice. A. Pilot flame may be too low or
blowing (high) causing the pilot/ valve safety to drop out.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Check wall switch and wires for proper connections. Jumper wire across terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad.
Check thermopile with millivolt meter. Take reading at ther­mopile terminals of gas valve. Should read 325 millivolts minimum with optional wall switch “OFF.” Replace faulty thermopile if reading is below specified minimum.
Check burner orifice for stoppage and remove. Clean and/or adjust pilot flame for maximum flame impinge-
ment on thermogenerator
(Figure 9 on page 7)
.
Page 15
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
N
ote: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in
the ON position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Burner will not light.
2. Burners come ON but
go OFF.
START
Turn Off Gas Supply
Assure Valve Switch Is In ON Position
Disconnect Control Harness
Set Thermostat To Call For Heat
A. Damper closed or
Damper Switch defective.
B. Faulty Valve System. C. Faulty limit switch.
D. OFF/ON or wall switch
defective.
A. Burner orifice plugged. B. Obstructed vent system.
Check For Proper Voltage At Control Harness (See Insert A). Voltage Should Be 24V Between Thermostat Or Pressure Switch And 24V Common And 24V Hot.
YES
Plug Control Harness Into Valve. Wait For Internal Check Delay.
Ensure damper control lever is locked in the open position, all the way to the right. If the damper control lever is locked in the open position troubleshoot through Steps B., C. and D. below. If the main burner will still not light, determine if the damper switch is defective and replace if necessary.
See Below. Reset the limit switch button. If still not working, access the leads attached to
the limit switch and check for continuity. If no continuity, replace limit switch. Disconnect the two black wires from the wire nuts. Test switch(s) for
continuity with a multimeter. If continuity is not indicated, switch(s) is defective and must be replaced.
Note: Before replacing OFF/ON switch, be sure to check wiring for loose connections or broken wires and repair as needed.
Check main burner orifice(s) for stoppage. Clean or replace. Check vent system for obstructions.
CHECK
Line Voltage Power
NO
Low Voltage Transformer
Limit Controller
2
Thermostat
Wiring
Insert A
24 Volt Hot
24 Volt Switched
Check For Damaged Or Missing Terminals In Connector
Insert B
Igniter Terminals
Igniter Will Cycle Off And Back On Once During
1
The 90 Second Ignition Trial. All Voltage Measurements Must Be Taken While The Igniter Is Powered.
End View Of Control Harness Connector
24 Volt Common
Igniter Warms Up And Glows Red.
1
YES
Turn On Gas Supply. Pilot Burner Lights.
YES
Main Valve Opens And Main Burner Lights.
YES
System Is Okay.
When Measured Voltage At Connections, Use
2
Care To Assure Terminals Are Not Damaged.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
With Pilot Burner Cable Connected, Measure
NO
Voltage At Valve HSI Element Output. 24V Nominal. (See Insert B)
YES
Replace Igniter/Flame Rod Assembly.
YES
NO
Check That Pilot Gas Is Flowing. Wait To Assure Plot Gas Tubing Is Purged. Recycle Call For Heat If Necessary.
YES
Measure Voltage Between 24V Hot And 24V Common Leads To Valve Control. Must Measure At Least 19.5 VAC With Igniter Powered (See Insert A). To Identify Proper Lead, This Check Must Be Done With The Valve Control Connected And Igniter Powered.
YES
Replace Pilot Assembly.
Check That Pilot Flame Makes Good Contact With
Pilot Burner Flame Rod.
NO
Check For Good Electrical Connection Through The Pilot Tubing.
If Both Of The Above Are Good, Replace Igniter/Flame Rod Assembly.
YES
Cycle Thermostat Off And Back On.
Main Burner Lights.
NO
2
1
Replace Valve.
NO
Replace Valve.
NO
Check Transformer And Line Volt Supply.
NO
Replace Valve.
15
Page 16
ACCESSORY COMPONENTS
Remote Control System (Standard) H0249 RCL
Standard Remote Control System (Model RCL)
The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes a hand-held transmitter, a remote receiver with wall-mount coverplate and all hardware re­quired to install the unit. The remote receiver can be wall or hearth mounted.
The transmitter has ON and OFF functions that are activated by pressing either button on the face of the transmitter. When a button on the transmitter is pressed, a signal light illuminates briefly to verify that a signal has been sent.
The Model RCL is designed to operate with all millivolt ignition systems, as well as electronic ignition systems. It may be installed with use for either natural or propane gas appliances. The RCL offers ease of installation and allows you to execute on-off commands to the fire­place effortlessly with one simple motion.
The Model RCL comes complete with detailed operating instructions.
Pine Cones and Wood Bits 91L05 FPCK
Twelve Piece Ember Kit
A twelve piece ember kit (model FPCK) has been developed to provide a means of enhanc­ing the already impressive log presentation of this fireplace. This kit contains three (3) ce­ramic fiber pine cones and nine (9) ceramic fiber debris wood bits. All twelve elements will not be consumed in the flames and may be placed within the presentation area (without impinging any of the lofting flames) to add realism and enhance the rustic look and ap­peal of the fire.
Decorative Volcanic Stone 80L42 FDVS Bag of Glowing Embers 88L53 FGE
Decorative Volcanic Stone
The decorative volcanic stone, Model FDVS, can be used to enhance the look of your appli­ance. Spread the decorative volcanic stone evenly around the bottom of the firebox.
Bag of Glowing Embers
Replacement ember materials are available for use with these appliances. Order a bag of Glowing Embers, Model FGE to replace ember materials as part of the periodic maintenance of the appliance.
12M20 38LBF 12M21 38LBF-BB 12M22 38LBF-BS 12M23 43LBF 12M24 43LBF-BB
Bi-Fold Doors 12M25 43LBF-BS
Bi-Fold Doors
Your appliance can be fitted with beautiful bi­fold doors. Model 38/43LBF doors are avail­able for use with these appliances. Doors are easily fitted to the fireplace opening. Model 38/43LBF doors come with standard black finish. Model 38/43LBF-BB doors have a beau­tiful bright brass finish. Model 38/43LBF-BS doors are made of brushed stainless steel.
To ensure warranty and to prevent a potential fire hazard, do not use any other doors on these appliances.
Touch-Up Paint Kit 90L73 FTPK-B
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch-up paint kit.
16
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 17
REPLACEMENT PARTS LIST MILLIVOLT
LBV-3824 LBV-4324
No. DESCRIPTION Part No. Qty. Part No. Qty.
1. Gas Fireplace Assembly –– ––
2. Firescreen 93076 2 93075 2
3. Rod, Screen 19242 2 19241 2
4. Refractory, Side (Standard) 43061 2 43061 2 Refractory, Side (L) (Herringbone) 126841 1 126843 1 Refractory, Side (R) (Herringbone) 126842 1 126844 1
5. Refractory, Rear 43071 1 43072 1 Refractory, Rear (Herringbone) 126831 1 126832 1
6. Refractory Access Panel 77M76 1 LB-97550A 1 Refractory Access Panel (Herringbone) 77M81 1 126854 1
7. Refractory, Base (Left) 125031 1 125031 1 Refractory, Base (Left) (Herringbone) 126853 1 126853 1
8. Refractory, Base (Right) 125051 1 125051 1 Refractory, Base (Right) (Herringbone) 126855 1 126855 1
9. Log Set, Complete H1607 1 904224 1
a. Log, Front/Left N/A N/A – b. Log, Center N/A N/A – c. Log, Rear N/A N/A – d. Log, Top/Right N/A N/A – e. Log, Rear/Top N/A N/A
10. Log Grate 77M80 1 125121 1
11. Burner Assembly Complete 77M79 1 125081 1
12. Gasket, Venturi 900272 1 900272 1
13. Venturi Tube 77M78 1 77M78 1
14. Bag of Glowing Embers 88L53 1 88L53 1
15. B-Vent Connector LB-97577A 1 LB-97577A 1
16. Front Face 43091-BLK 1 LB-97352A 1
GAS CONTROLS MILLIVOLT
Natural Propane
No. DESCRIPTION Part No. Qty. Part No. Qty.
*20. Gas Valve - SIT H165801 1 H165901 1 *21. Gas Valve - Honeywell 62L05 1 62L05 1
22. Piezo Igniter - SIT 10K8601 1 10K8601 1
23. Orifice, Standard 903881 1 903882 1
24. Pilot Assembly - SIT 62L1201 1 62L1301 1
25. Thermogenerator 60J7901 1 60J7901 1
26. Piezo Ignitor, Lead Wire - SIT 902564 1 902564 1
27. Damper Switch 94468 1 94468 1
28. Limit Switch H1614 1 H1614 1
29. Pilot Tube 74L5601 1 74L5601 1
* Appliances may be fitted at the factory with either a Honeywell or SIT Millivolt gas control valve. Valve will need to be converted from Natural to Propane for propane units.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
17
Page 18
REPLACEMENT PARTS MILLIVOLT
15
1
3
e.
d.
9
c.
2
27
28
a.
b.
4
16
10
5
Standard Refractorys Shown
14
18
12
13
29
11
7
25
26
22
24
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
6
23
8
20
21
Page 19
REPLACEMENT PARTS LIST ELECTRONIC
LBV-3824 LBV-4324
No. DESCRIPTION Part No. Qty. Part No. Qty.
1. Gas Fireplace Assembly –– ––
2. Firescreen 93076 2 93075 2
3. Rod, Screen 19242 2 19241 2
4. Refractory, Side (Standard) 43061 2 43061 2 Refractory, Side (L) (Herringbone) 126841 1 126843 1 Refractory, Side (R) (Herringbone) 126842 1 126844 1
5. Refractory, Rear 43071 1 43072 1 Refractory, Rear (Herringbone) 126831 1 126832 1
6. Refractory Access Panel 77M76 1 LB-97550A 1 Refractory Access Panel (Herringbone) 77M81 1 126854 1
7. Refractory, Base (Left) 125031 1 125031 1 Refractory, Base (Left) (Herringbone) 126853 1 126853 1
8. Refractory, Base (Right) 125051 1 125051 1 Refractory, Base (Right) (Herringbone) 126855 1 126855 1
9. Log Set, Complete H1607 1 904224 1
a. Log, Front/Left N/A N/A – b. Log, Center N/A N/A – c. Log, Rear N/A N/A – d. Log, Top/Right N/A N/A – e. Log, Rear/Top N/A N/A
10. Log Grate 77M80 1 125121 1
11. Burner Assembly Complete 77M79 1 125081 1
12. Gasket, Venturi 900272 1 900272 1
13. Venturi Tube 77M78 1 77M78 1
14. Bag of Glowing Embers 88L53 1 88L53 1
15. B-Vent Connector LB-97577A 1 LB-97577A 1
16. Front Face 43091-BLK 1 LB-97352A 1
GAS CONTROLS ELECTRONIC
Natural Propane
No. DESCRIPTION Part No. Qty. Part No. Qty.
20. Gas Valve - Honeywell 62L1801 1 62L1901 1
21. Pilot Assembly, Honeywell 62L1401 1 62L1501 1
22. Transformer 42J3201 1 42J3201 1
23. Orifice, Standard 903881 1 903882 1
24. Damper Switch 94468 1 94468 1
25. Limit Switch H1614 1 H1614 1
26. Ignitor Assembly Replacement Kit 87L54 1 87L54 1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
19
Page 20
REPLACEMENT PARTS ELECTRONIC
15
1
3
e.
d.
9
c.
2
24
a.
b.
4
25
16
10
5
Standard Refractorys Shown
14
11
12
13
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.