HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
OTL Report No. 116-F-18-05
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO­SION MAY RESULT CAUSING PROPERTY DAM­AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin­ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
B-VENT ELITE
B-VENTED GAS APPLIANCES P/N 504,138M REV. H 03/2007
®
SERIES
MODELS
Millivolt Models Electronic Models
LBV-3824MN LBV-3824EN LBV-3824MP LBV-3824EP LBV-3824MN-H LBV-3824EN-H LBV-3824MP-H LBV-3824EP-H LBV-4324MN LBV-4324EN LBV-4324MP LBV-4324EP LBV-4324MN-H LBV-4324EN-H LBV-4324MP-H LBV-4324EP-H
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence ni d'autre vaperurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le batiment où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appeflez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié installer, agence de service ou le fournisseur de gaz.
1
CONGRATULATIONS!
In selecting this LENNOX B-vented gas appliance you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product.
TABLE OF CONTENTS
Introduction..................................... page 2
General Information......................... page 2
Operation/Care of Your Appliance.... page 3
Damper & Combustion Air Controls page 4
Manual Limit Switch........................ page 5
Maintenance .................................... page 5
Burner Adjustments......................... page 5
Flame Appearance and Sooting ....... page 5
Maintenance Schedule..................... page 6
Adjustment ...................................... page 7
Millivolt Appliance Checkout............ page 7
Electronic Appliance Checkout......... page 7
Log and Rockwool Placement ......... page 7
Wiring Diagrams.............................. page 9
Warranty.......................................... page 9
Product Reference Information ....... page 9
Replacement Parts .......................... page 9
Lighting Instructions – Millivolt....... page 10
Lighting Instructions – Electronic.... page 12
Troubleshooting Guide – Millivolt ..... page 14
Troubleshooting Guide – Electronic .. page 15
Accessory Components................... page 16
Replacement Parts List..................... page 17
INTRODUCTION
The millivolt appliances are designed to oper­ate on either natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation.
The electronic appliances are designed to op­erate on either natural or propane gas. An electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these units.
These appliances comply with National Safety Standards and are tested and listed by Omni­Test Laboratories (Report No. 116-F-18-5) to ANSI Z21.50b-2002 (in Canada, CSA-2.22b-
2002), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Elec­trical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
GENERAL INFORMATION
Note: Installation and repair should be per­formed by a qualified service person. The appli­ance should be inspected annually by a quali­fied professional service technician. More fre­quent inspections and cleanings may be re­quired due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les in­structions d'installation et d'utilisation qui accompagnent l'apareil.
Provide adequate clearances around air open­ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
Due to high temperatures the appliance should be located out of traffic and away from furni­ture and draperies. Locate furniture and win­dow coverings accordingly.
WARNING: THESE FIREPLACES ARE VENTED DECORATIVE GAS APPLI­ANCES. DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will degrade the performance of this system and may be dan­gerous.
Input of appliances are 45,000 and 50,000 BTU/ HR for LBV-3824 and LBV-4324 respectively.
Gas Orifice Size
Type Elevation
LBV-3824
LBV-4324
Nominal operating pressures for the manifold side of the gas control system are; 3.5 inches water column (6.54 MmHg) for natural gas models and 10 inches water column (18.69 MmHg) for propane gas models.
Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water.
Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'lau.
Millivolt appliances may be fitted at time of manufacture with either a Honeywell millivolt gas control valve or as SIT millivolt gas control valve. Both valves have been tested with and approved for use with these appliances and are listed accordingly.
Natural
0.125 in.
#30
Propane
#48
#47
0 - 4500' (0 - 1370 m)
0 - 4500' (0 - 1370 m)
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Test gage connections are provided on the
Refractory Access Panel
SIT Valve Shown
Gas Controls On Valve
front of the millivolt gas control valves (identi­fied OUT for the manifold side and IN for inlet pressure side for both SIT and Honeywell equipped appliances. A ¹⁄₈" NPT test gage connection is provided on the electronic gas control valve adjacent to the outlet to the main burner.
Minimum inlet gas pressure to the appliance is
5.0 inches water column (9.5 MmHg) for natural gas and 11 inches water column (20.55 MmHg) for propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to the appliance is 10.5 inches water column (19.95 MmHg) for natural gas and 13.0 inches water column (24.25 MmHg) for propane.
The appliance must be isolated from the gas supply piping system (by closing its individual manual shut-off valve) during any pressure test­ing of the gas supply piping system at test pressures equal to or less than ¹⁄₂ psig (3.5 kPa).
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ¹⁄₂ psig (3.5 kPa).
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN­STRUCTIONS PROVIDED IN THIS DOCU­MENT WILL RESULT IN AN IMPROP­ERLY INSTALLED AND OPERATING AP­PLIANCE, VOIDING ITS WARRANTY. ANY CHANGE TO THIS APPLIANCE AND/ OR ITS OPERATING CONTROLS IS DAN­GEROUS. IMPROPER INSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERIOUS INJURY OR DEATH FORM FIRE, BURNS, EXPLOSION OR CARBON MON­OXIDE POISONING.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be op­erating correctly.
WARNING: B-VENT APPLIANCES ARE NOT DESIGNED TO OPERATE IN NEGATIVELY PRESSURED ENVIRONMENTS (PRES­SURE WITHIN THE HOME IS LESS THAN PRESSURES OUTSIDE). SIGNIFICANT NEGATIVELY PRESSURED ENVIRON­MENTS CAUSED BY WEATHER, HOME DESIGN, OR OTHER DEVICES MAY IM­PACT THE OPERATION OF THESE APPLI­ANCES. NEGATIVE PRESSURES MAY RESULT IN POOR FLAME APPEARANCE, SOOTING, DAMAGE TO PROPERTY AND/ OR SEVERE PERSONAL INJURY. DO NOT OPERATE THESE APPLIANCES IN NEGA­TIVELY PRESSURED ENVIRONMENTS.
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE­FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES ENFANTS. GARDER LES VÊTEMENTS, LES MEUBLES, L'ESSENCE OU AUTRES LIQUIDES À VAPEUR INFLAMMABLES LIN DE L'APPAREIL.
OPERATION AND CARE OF YOUR APPLIANCE
1. Appliance operation may be controlled
through a remotely located optional wall switch. Separate switches may provide independent control for the remote controlled fireplace op­eration (optional equipment). In lieu of remote or remote wall switch operation, the appliance must be operated directly through the controls located on the front of the valve located within the control compartment under the removable refractory access panel,
Operation of millivolt and electronic gas con­trol systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance.
Figure 1
ment below the lower refractory panel.
to access the gas control compart-
Figure 1
.
Refer to
Figure 1
Millivolt appliances will be fitted with one of the two gas control valves shown in
on page 4
tems will be fitted with the electronic valve shown in yourself with the differing controls for the valve your appliance uses.
To light millivolt appliances refer to the de­tailed lighting instructions found in both En­glish and French on pages 10 and 11 of these instructions respectively. Millivolt and elec-
tronic appliance lighting instructions may also be found on the pull out rating plate located within the gas control compartment.
Refer to used with your appliance.
If your appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control. If the appliance is not equipped with a wall or remote control, the main burner must be turned off and on with the gas control knob. Turn the knob counter-clockwise from the PILOT position to ON to light the main burner, and clockwise from ON to PILOT to turn off the main burner.
To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 12 and 13 of these instructions respectively. Millivolt and
electronic appliance lighting instructions may also be found on the pull out rating plate located within the gas control compartment.
If your appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turner on and off with the wall switch or remote control. If the appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with the gas control switch. Toggle the switch from ON to OFF to operate the main burner from ON to OFF.
. Appliances with electronic sys-
Figure 3 on page 4
Figure 2
for the spark ignitor location
Figure 2
. Familiarize
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
T
O
L
I
P
N
O
T
O
it
L
I
P
O
F
F
IN OUT
SIT Millivolt Valve
Spark Ignitor
Honeywell Millivolt Valve
Gas Control Knob
Gas Control Knob
O
N
P
I
L
O
O
F
F
T
Figure 2
Electronic Gas Control Valve
P S I
IN
ON/OFF Switch
E IT N IG
OFF
ON
CONTROL
Figure 3
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is due to the burn-in of internal paints and lubricants used in the manufacturing process.
3. Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materi­als, etc. It is important that control compart­ments, burners and circulating air passage­ways of the appliance be kept clean.
4. Always turn off gas to the pilot (millivolt appliances) before cleaning. Before re-light­ing, refer to the lighting instructions in this manual. Instructions are also found on a pull­out panel located on the floor of the appliance.
5. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
TPTH TP TH
Spark Ignitor
6. Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution when using products with combustible vapors.
7. Clean the optional glass doors only when necessary. Wipe surface with clean, damp­ened, soft cloth. Follow with dry, soft towel as desired. Take care not to scratch the glass surface.
WARNING: DO NOT USE ABRASIVE CLEANERS. NEVER CLEAN THE GLASS WHEN IT IS HOT.
CAUTION: DO NOT ATTEMPT TO TOUCH THE DOORS WITH YOUR HANDS WHILE THE FIRE­PLACE IS IN USE. ALWAYS USE DOOR HANDLES. DOORS WILL BECOME VERY HOT WHEN FIREPLACE IS IN USE.
WARNING: FIREPLACES EQUIPPED WITH OPTIONAL ACCESSORY DOORS SHOULD BE OPERATED ONLY WITH THE DOORS FULLY OPEN OR FULLY CLOSED
(FIGURE 4 ).
THIS APPLI­ANCE MAY ONLY BE FITTED WITH DOORS CERTIFIED FOR USE WITH THE APPLIANCE.
AVERTISSEMENT: POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÊES AVEC L'APPAREIL.
Fully Open or Fully Closed
Figure 4
DAMPER AND OUTSIDE AIR CONTROLS
This appliance is fitted with a manually con­trolled vent damper. The vent damper should be closed when the appliance is not in use to prevent cold air from entering the home through the venting system. The damper is controlled through the use of a control lever located within the appliance opening at the top center in front of the firebox lintel
(see Figure 5 )
. The control lever snaps into place at either extreme of its range of motion. When locked in position all the way to the right, the damper is open. When locked in position all the way to the left, the damper is closed.
The damper lever actuates a switch, (see wir­ing diagram) which will prevent the appliance main burner from lighting unless the damper is locked open. The appliance flue damper must always remain open when operating.
WARNING: DAMPER MUST BE IN OPEN POSITION WHEN APPLIANCE MAIN BURNER IS OPERATING.
AVERTISSEMENT: LE REGISTRE DOIT ÊTRE EN POSITION OUVERTE LORSQUE LE OU LES BRULEURS PRINCIPAUX DE L'APPEREIL FONCTIONNMENT.
Locked
Closed
Locked Open
Outside Air Actuator
Figure 5
4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Many appliances are equipped when installed with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation. The shut-off lever for the outside air system is standard on all appliances but should not be operated if the complete system is not installed. Refer to complete outside air vent system is installed, the installer will remove the cover from the shut-off lever located in the left side of the firebox opening.
If your cover is not removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the pres­ence of the complete system. DO NOT assume that you have this system in place.
The hand operated shut-off lever is located in the left side of the fireplace opening behind the screen. To open, pull all the way. The outside air damper should be fully open when the fireplace is in use and completely closed when the fire­place is not being used. This will prevent outside cold air from entering the dwelling.
Figure 6
Figure 5
Detail A
. When the
WARNING: DO NOT OPERATE THE SHUTOFF LEVER UNLESS A COMPLETE OUTSIDE AIR VENT SYSTEM HAS BEEN INSTALLED WITH YOUR APPLIANCE.
MANUALLY-RESET BLOCKED FLUE SAFETY SWITCH
This appliance is equipped with a manually­reset blocked flue safety switch. Refer to
Figure 6
operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool, then reset the safety switch by pushing the red reset button.
This reset button is located on the back of the limit switch, between the wire terminals (
Detail A of Figure 21
The appliance should then relight and remain lit. If this does not occur, turn off the appli- ance and call a qualified service technician.
for its location. If during appliance
see
).
Wire Terminals
Maintenance
The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni­cian. Proper maintenance and use will require more frequent, less extensive inspections and servicing by the homeowner.
Generally, annual inspections should be per­formed by a qualified service technician. More frequent periodic inspections and cleanings should be performed by the homeowner. Any discrepancies discovered by the homeowner should result in a call to a qualified service technician to effect the repair or correction.
Refer to the maintenance schedule for mainte­nance tasks, procedures, periodicity and by whom they should be performed.
IMPORTANT: TURN OFF GAS AND ANY ELEC­TRICAL POWER BEFORE SERVICING THE APPLIANCE.
Burner Adjustments
Flame Appearance and Sooting
Proper flame appearance is a matter of taste. Generally most people prefer the warm glow of a yellow to orange flame. Appliances operated with air shutter openings that are too large, or with long vertical vent runs, will exhibit flames that are blue and transparent. These weak, blue and transparent flames are termed anemic.
Lintel Extension
Reset
Button
Manual Reset Limit Switch
Right Side Refractory Panel
If the air shutter opening is too small sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits form­ing on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termi­nation. Sooting is caused by incomplete com­bustion in the flames and a lack of combustion air entering the air shutter opening.
To achieve a warm yellow to orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
No smoke or soot should be present. Reposi­tion the log set if the flames impinge on any of them.
If sooting conditions exist, the air shutter opening on the main burner can be adjusted. Normally, the more offsets in the vent system, the greater the need for the air shutter to be opened further.
WARNING: AIR SHUTTER ADJUSTMENT SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
Maintenance Schedule
Annually (Before the onset of the Burning Season)
Maintenance Task Accomplishing Person Procedure
Inspecting/Cleaning Burner, Logs and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Appliance Checkout
Replacing Rockwool Ember Materials
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services Technician
Inspect valve and ensure it is properly operat­ing. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area.
Refer to
Figure 8 on page 7
and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Refer to
Figure 9 on page 7.
Remove any surface build-up on pilot and burner assem­bly. Wipe the pilot nozzles, ignitor/flame rod and hood. Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca­tion of the vent components.
Perform the appropriate appliance checkout procedure detailed in this manual.
Remove old ember materials and vacuum the rockwool placement area. Place new rockwool as described in this document.
Periodically (After the Burning Season)
Maintenance Task Accomplishing Person Procedure
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Optional Glass Doors
Homeowner
Homeowner
Homeowner
Homeowner
Carefully remove logs, Rockwool and volcanic stone if used. Vacuum out interior of the firebox. Clean firebox walls and log grate. Replace logs, Rockwool and volcanic stone as detailed in this manual.
Refer to
Figure 8 on page 7
and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca­tion of the vent components.
Clean as necessary following the directions provided in this manual. DO NOT TOUCH OR
ATTEMPT TO CLEAN DOORS WHILE THEY ARE HOT.
6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.