PRODUCT LITERATURE
¤
1997 Lennox Industries Inc.
'DOODV 7H[DV
0
6XSHUVHGHV 0
£
*+5
6(5,(6
*$6 )851$&(
,I WKH LQIRUPDWLRQ LQ WKLV PDQXDO LV QRW
IROORZHG H[DFWO\ D ILUH RU H[SORVLRQ
PD\ UHVXOW FDXVLQJ SURSHUW\ GDPDJH
SHUVRQDO LQMXU\ RU ORVV RI OLIH
'R QRW VWRUH RU XVH JDVROLQH RU RWKHU
IODPPDEOH YDSRUV DQG OLTXLGV LQ WKH
YLFLQLW\ RI WKLV RU DQ\ RWKHU DSSOLDQFH
,QVWDOODWLRQ DQG VHUYLFH PXVW EH SHU
IRUPHG E\ D TXDOLILHG LQVWDOOHU VHUYLFH
DJHQF\ RU WKH JDV VXSSOLHU
£
:$51,1*
:+$7 72 '2 ,) <28 60(// *$6
-
'R QRW WU\ WR OLJKW DQ\ DSSOLDQFH
-
([WLQJXLVK DQ\ RSHQ IODPHV
-
'R QRW WRXFK DQ\ HOHFWULFDO VZLWFK GR QRW
XVH DQ\ SKRQH LQ \RXU EXLOGLQJ
-
,PPHGLDWHO\ FDOO \RXU JDV VXSSOLHU IURP D
QHLJKERUV SKRQH )ROORZ WKH JDV VXSSOLHUV
LQVWUXFWLRQV
-
,I \RX FDQQRW UHDFK \RXU JDV VXSSOLHU FDOO
WKH ILUH GHSDUWPHQW
/LWKR 86$
3DJH

*+5 3$576 ,'(17,),&$7,21 'RZQIORZ $SSOLFDWLRQ 6KRZQ
CABINET
BLOWER MOTOR
COMBUSTION AIR PROVING
(PRESSURE) SWITCH
DuralokPlus
HEAT EXCHANGER
ASSEMBLY
EXHAUST PIPE
CONNECTION
CONDENSATE TRAP
TM
CONNECTION
BURNER
BOX
BURNERS
FIGURE
WARNING
Product contains fiberglass wool.
Disturbing the insulation in this product during
installation, maintenance, or repair will expose
you to fiberglass wool. Breathing this may cause
lung cancer. (Fiberglass wool is known to the
State of California to cause cancer.)
Fiberglass wool may also cause respiratory, skin,
and eye irritation.
To reduce exposure to thissubstance or for further
information, consult material safety data sheets
available from address shown below, or contact
your supervisor.
Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379--9900
,03257$17 ',5(&7,216
1-- Keep the furnace area clear and free of combus-
tible material, gasoline, and other flammable va-
pors and liquids. If installed in an insulated area,
furnace must be kept free of insulating material. In-
sulating material may be combustible.
FILTER
TOP CAP
BLOWER ACCESS
DOOR
CONTROL BOX
INTEGRATED
IGNITION/BLOWER
CONTROL
DOOR INTERLOCK
SWITCH
COMBUSTION AIR
BLOWER
GAS
VALVE
FRESH AIR INTAKE
CONNECTION
HEATING ACCESS
PANEL
FLAME SIGHT
GLASS
1
2-- DO NOT obstruct air flow to unit. Unit must re-
ceive an unobstructed flow of combustion and
ventilating air.
3-- DO NOT store chlorine or fluorine products near
unit or introduce these products into the combus-
tion air. These products can cause furnace corro-
sion.
WARNING
If overheating occurs or if gas supply fails to shut
off, shut off the manual gas valve to the appliance
before shutting off electrical supply.
WARNING
Do not use this furnace if any part has been under-
water. Immediately call a qualified service techni-
cian to inspect the furnace and to replace any part
of the control system and any gas control which
has been under water.
CAUTION
Before attempting to perform any service ormain-
tenance, turn the electrical power to unit OFF at
disconnect switch.
3DJH