See unit nameplate for manufacturer
and address.
504,558M
8/2002
Supersedes 2/2002
WARNING
GCS16−024, 030, 036, 048, 060
GCS20−024, 030, 036, 048, 060
GCS20R−024, 030, 036, 042, 048, 060
Improper installation, adjustment, alteration, ser
vice or maintenance can cause property damage,
personal injury or loss of life. Installation and ser
vice must be performed by a qualified installer, ser
vice agency or the gas supplier
READ ALL INSTRUCTIONS IN THIS MANUAL
FBR113270
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Installation and service must be per
formed by a qualified installer, ser
vice agency or the gas supplier.
AND RETAIN FOR FUTURE REFERENCE
If the information in this manual is not
followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
Litho U.S.A.
WARNING
WHAT TO DO IF YOU SMELL GAS:
S Do not try to light any appliance.
S Extinguish any open flames.
S Do not touch any electrical switch; do not
use any phone in your building.
S Leave the building immediately.
S Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli
er’s instructions.
S If you cannot reach your gas supplier, call
the fire department.
E2002
08/02
*2P0802*
504,558M
*P504558M*
GCS16, 20, and 20R Parts Arrangement
VENT CAP
COMBUSTION AIR INDUCER JUNCTION BOX
GAS
VALV E
BURNER
Safety
1− Keep unit area clear and free of combustible materi
als, gasoline and other flammable vapors and liquids.
2− Inspect return air duct to ensure duct is sealed to
the unit and terminates outside the space contain
ing appliance.
WARNING
Product contains fiberglass wool.
Disturbing the insulation in this product during
installation, maintenance, or repair will expose you
to fiberglass wool. Breathing this may cause lung
cancer. (Fiberglass wool is known to the State of
California to cause cancer.)
Fiberglass wool may also cause respiratory, skin,
and eye irritation.
To reduce exposure to this substance or for further
information, consult material safety data sheets
available from address shown below, or contact
your supervisor.
P.O. Box 799900
Dallas, TX 75379−9900
WARNING
CONDENSER
COIL
COMPRESSOR
WARNING
Electric shock hazard. Can cause
injury or death. Before attempting to
perform any service or maintenance,
turn the electrical power to unit OFF at
disconnect switch(es). Unit may have
multiple power supplies.
WARNING
Danger of explosion. Can cause injury
or product or property damage. Should
the gas supply fail to shut off or if
overheating occurs, shut off the gas
valve to the furnace before shutting off
the electrical supply.
WARNING
Danger of explosion and fire. Failure to
follow safety warnings exactly could
result in dangerous operation, serious
injury, death or property damage.
Do not use this furnace if any part has been under
water. A flood−damaged furnace is extremely dan
gerous. Attempts to use the furnace can result in
fire or explosion. A qualified service agency
should be contacted to inspect the furnace and to
replace all gas controls, control system parts,
electrical parts that have been wet or the furnace
if deemed necessary.
CAUTION
Label all wires prior to disconnection when servic
ing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
Page 1