Lennox GCM07N, GCM09N, GHM09N, GCM12N, GHM07N Service Manual

...
HVAC EUROPE
SPLIT TYPE, HEAT PUMP AIR CONDITIONERS
Technical & service manual 2005
R410a Wall Mounted
[Models]
GCM07N niet leverbaar
GHM07N niet leverbaar
GCM09N
GHM09N
GCM12N
GHM12N
GCM18N
GHM18N
1
GC(H)M Series (R410A)
Contents
1. Features………………………………………………………………… 02
2. Specification………………………………………………………..……03
3. Dimensions…………………………………………………………..… 05
4. Refrigeration cycle diagram……………………………………………09
5. Pressure table…………….……………………………………….……10
6. Capacity table…………………………………………………………...14
7. Wiring diagram…………………………………………………..………20
8. Electronic function………………………………………….…………...25
9. Troubleshooting……………………………………………………….…33
10. Characteristic of temp. sensor…………………………………………36
2
1.Features
1.1 Compact design
1.2 High efficiency and quiet operation
1.3 A class energy level
3
2.Specification
Model
GCM-
07N GHM-
07N GCM-09N GHM-
09N
Power supply
Ph-V-Hz
1, 220-240V~, 50Hz
1, 220-240V~, 50Hz
1, 220-240V~, 50Hz
1, 220-240V~, 50Hz
Capacity
Btu/h 7000 7000 9000 9000
Input
W
640 640 820 820
Rated current
A
2.8 2.8 3.6 3.6
Cooling
EER
Btu/w.h, w/w
11,3.2 11,3.2 11,3.2 11,3.2
Ca
pacity
Btu/h
8500
11000
Input
W 690
890
Rated current
A 3.0
3.9
Heating
COP
W/W
3.6
3.6
Moisture Removal
L/h 0.7 0.7 1.0 1.0
Max. input consumption
W
850 1000 1000 1200
Max. current
A
3.8 4.5 4.5 5.3
Starting current
A
Model
PA82X1C
-
4DZDE PA82X1C
-
4DZDE PA108X1C
-
4FTDE PA108X1C
-
4FTDE
Type
Rotary Rotary Rotary Rotary
Brand
TOSHIBA
TOSHIBA
TOSHIBA
TOSHIBA
Capacity
Btu/h 7000 7000 9000 9000
Input
W
730 730 920 920
Rated current(RLA)
A
3.3 3.3 4.1 4.1
Locked rotor Amp(LRA)
A
16.0 16.0 18.7 18.7
Thermal protector
MRA13408
-
9087 MRA13408
-
9087 MRA13430
-
9087 MRA13430
-
9087
Capacitor
uF 25 25 25 25
Compressor
Ref
rigerant oil
ml
300 300 330 330
Model
RPG13H
RPG13H
RPG13H
RPG13H
Brand
Welling Welling Welling Welling
Input
W
36.5 36.5 39.5 39.5
Capacitor
uF
1.2 1.2 1.2 1.2
Indoor fan motor
Speed(hi/mi/lo)
r/min 1050/920/820
1050/9
20/820 1200/950/850
1200/950/850
Indoor air flow (Hi/Mi/Lo)
m3/h 450/400/350
450/400/350
500/430/370
500/430/370
Indoor noise level (Hi/Mi/Lo)
dB(A) 35/32/30
35/32/30
37/34/31
37/34/31
Dimension (W*H*D)
mm
710×250×190
710×250×190
710×250
×195 710×250×195
Packing (W*H*D)
mm
800×340×270
800×340×270
800×340×270
800×340×270
Indoor unit
Net/Gross weight
Kg
8/10 8/10 8/10 8/10
Model
YDK24-6T YDK24-6T YDK24-6F YDK24-6F
Brand
Welling Welling Welling Welling
Input
W 56 56 56 56
Capacitor
uF
2.5 2.5 2.5 2.5
Outdoor fan motor
Speed
r/min 800 800 800 800
Outdoor air flow
m3/h 1500 1500 1800 1800
Outdoor no
ise level
dB(A) 49 49 50 50
Dimension(W*H*D)
mm
700X535X235
700X535X235
780X540X250
780X540X250
Packing (W*H*D)
mm
815X580X325
815X580X325
910X575X335
910X575X335
Outdoor unit
Net/Gross weight
Kg
31/34 32/35 36/39 37/40
Refrigerant type R4
10A
g
800 820 900 920
Design pressure
MPa 4.2 4.2 4.2 4.2
Liquid side/ Gas side
mm(inch)
Ф
6.35/Ф9.53
Ф
6.35/Ф9.53
Ф
6.35/Ф9.53
Ф
6.35/Ф9.53
Max. refrigerant pipe length
m 10 10 10 10
Refrigerant piping
Max. difference in level
m 5 5 5 5
Connection wiring
No No No No
Plug type
16A 16A 16A 16A
Thermostat type
Electrolic control
Electroli
c control Electrolic control
Electrolic control
Operation temp
17-30 17-30 17-30 17-30
Ambient temp
18~-45 -7 -~
45 18~-45 -7 -~
45
Application area
m2 10-14 10-14 14-21 14-21
Qty’per 20’ /40’ /40'HQ
set 126/272/298
126/272/298
113/238/274
113/238/274
1 The noise date is base on hemi-anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient
condition.
4
Model
GCM-12N GHM-
12N GCM-
18N GHM-18N
Power su
pply Ph-V-Hz 1, 220-240V~, 50Hz
1, 220-240V~, 50Hz
1, 220-240V~,50Hz
1, 220-240V~,50Hz
Capacity
Btu/h 12000 12000 18000 18000
Input
W
1120 1120 1720 1720
Rated current
A
5.0 5.0 7.8 7.8
Cooling
EER
Btu/w.h,
w/w 11,3.2 11,3.2 10.5,3.1 10.5,3.1
Capacity
15000
19000
Input
1180
1650
Rated current
5.3
8.0
Heating
COP
3.6
3.4
Moisture Removal
L/h 1.2 1.2 1.6 1.6
Max. input
consumption
W
1550 1550 2500 2500
Max. current
A 10 10
11.5 11.5
Starting current
A 30 30
42.5 42.5
Model
PA140X2C
-
4FT PA140X2C
-
4FT
PA200X2CS
-
4KU1 PA200X2CS
-
4KU1
Type
rotary R
otary Rotary Rotary
Brand
TOSHIBA
TOSHIBA
Toshiba Toshiba
Capacity
Btu/h 12000 12000 16910 16910
Input
W
1200 1200 1720 1720
Rated current(RLA)
A
5.4 5.4 7.50 7.50
Locked rotor Amp(LRA)
A
29.9 29.9 34.5 34.5
Thermal protector
UP3RE059
1-T56 UP3RE0591
-
T56 Internal Internal
Capacitor
uF 35 35 45 45
Compressor
Refrigerant oil
ml
480 480 ESTER OIL VG74 ·750
ESTER OIL VG74 ·750
Model
RPG13D
RPG13D
RPG28D
RPG28D
Brand
Welling Welling Welling Welling
Input
W 44 44 53 53
Capacitor
uF
1.2 1.2 1.5uF/450V
1.5uF/450V
Indoor fan motor
Speed(hi/mi/lo)
r/min 1220/1000/800
1220/1000/800
1180/1080/800
1180/1080/800
Indoor air flow (Hi/Mi/Lo)
m3/h 580/500/420
600/520/420
850/700/600
850/700/600
Ind
oor noise level (Hi/Mi/Lo)
dB(A) 40/37/34
40/37/34
42/39/37
42/39/37
Dimension (W*H*D)
mm
790×265×193
790×265×193
920×292×225
1000×353×280
Packing (W*H*D)
mm
875x285x375
875x285x375
1015×368×295
1015×368×295
Indoor unit
Net/Gross weight
Kg
9.0/11.5
9/11 13/15 13/15
Model
YDK24-6F YDK24-6F YDK53-6K YDK53-6K
Brand
Welling Welling Welling Welling
Input
W 56 56
125 125
Capacitor
uF
2.5 2.5 3.5 3.5
Outdoor fan motor
Speed
r/min 800 800 800 800
Outdoor air flow
m3/h 1800 1800 2500 2500
Outdoor noise level
dB(A) 50 50 52 52
Dimension(W*H*D)
mm
780X540X250
780X540X250
845X695X335
845X695X335
Packing (W*H*D)
mm
910X575X335
910X575X335
970X770X395
970X770X395
Outdoor unit
Net/Gross weight
Kg
37/40 38/41 52/56 52/56
Refrigerant type R410A
g
1050 1080 1690 1740
Design pressure
MPa 4.2 4.2 3.8 3.8
Liquid side/ Gas side
mm(inch)
Ф
6.35/Ф12.7
Ф
6.35/Ф12.7
Ф
6.35/Ф12.7
Ф
6.35/Ф12.7
Max. refrigerant pipe length
m 10 10 15 15
Refrigerant piping
Max. difference in level
m 5 5 8 8
Connection wiring
No No No No
Plug type
16A 16A NO PLUG
NO PLUG
Thermostat type
Electrolic control
Electrolic control
Electronic control
Electronic control
Operation temp
17-30 17-30 17-30 17-30
Ambient temp
18~-45 -7 -~
45
18-45 -
7~45
Application area
m2 18-26 18-26
28~40 28~40
Qty’per 20’ /40’ /40'HQ
set 94/199/232
94/199/232
70 / 148 / 170
70 / 148 / 170
1 The noise date is base on hemi-anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient
condition.
5
3.Dimensions
3.1 Indoor unit GCM-07N,GHM07N,GCM09N,GHM09N
3.2 Indoor unit GCM-12N, GHM12N
6
3.2 Indoor unit GCM-18N,GHM18N
7
3.4 Outdoor unit
GCM-07N,GHM07N
3.5 Outdoor unit
GCM-09N1,GHM09N,GCM12N,GHM12N
8
GCM-18N,GHM18N
12.5
9
4.Refrigeration cycle diagram
10
5. Pressure table Note: *The pressure data is from 3 way valve, the pressure data are pressure above atmosphere. *D: Dry bulb temp. *W: Wet bulb temp.
5.1GCM07N
Cooling mode
Outdoor temperature (Dry bulb temp)
Indoor Conditions
Pressure 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
15ºC W
Pressure
( kg/cm2 )
6.2 6.7 7.2 8.0 8.5 9.4
24ºC D
17ºC W
Pressure
( kg/cm2 )
6.3 6.5 7.5 8.1 8.7 9.5
27ºC D
19ºC W
Pressure
( kg/cm2 )
6.1 6.8 7.7 8.2 9.0 10.0
32ºC D
23ºC W
Pressure
( kg/cm2 )
7.0 7.3 7.8 8.4 9.2 10.1
.2GHM07N
Cooling mode
Outdoor temperature (Dry bulb temp)
Indoor
Conditions
Pressure 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
15ºC W
Pressure
( kg/cm2 )
6.2 6.7 7.2 8.0 8.5 9.4
24ºC D
17ºC W
Pressure
( kg/cm2 )
6.3 6.5 7.5 8.1 8.7 9.5
27ºC D
19ºC W
Pressure
( kg/cm2 )
6.1 6.8 7.7 8.2 9.0 10.0
32ºC D
23ºC W
Pressure
( kg/cm2 )
7.0 7.3 7.8 8.4 9.2 10.1
Heating mode
OUTDOOR CONDITIONS
Indoor Conditions
Pressure
12ºC D
11ºC W
7ºC D
6ºC W
0
ºC D
-1ºC W
-
4ºC D
-6ºC W
-7ºC D
-9ºC W
-15ºC D
-xºC W
15ºC
Pressure
( kg/cm2 )
24.0 23.0 21.5 21.0 20..5 /
18ºC
Pressure
( kg/cm2 )
24.6 23.5 23.0 22.6 20.8 /
20ºC
Pressure
( kg/cm2 )
25.0 24.2 24.0 23.0 21.0 /
22ºC
Pressure
( kg/cm2 )
25.3 24.6 24.5 23.8 21.7 /
11
5.3GCM09N
Cooling mode
Outdoor temperature (Dry bulb temp)
Indoor Conditions
Pressure 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
15ºC W
Pressure
( kg/cm2 )
7.8 8.1 8.4 9.0 9.3 10.0
24ºC D
17ºC W
Pressure
( kg/cm2 )
7.9 8.2 8.7 9.0 9.5 10.1
27ºC D
19ºC W
Pressure
( kg/cm2 )
8.0 8.5 9.2 9.9 10.2 10.8
32ºC D
23ºC W
Pressure
( kg/cm2 )
8.8 9.1 9.2 10.0 10.5 11.2
5.4GHM09N
Cooling mode
Outdoor temperature (Dry bulb temp)
Indoor Conditions
Pressure 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
15ºC W
Pressure
( kg/cm2 )
7.8 8.1 8.4 9.0 9.3 10.0
24ºC D
17ºC W
Pressure
( kg/cm2 )
7.9 8.2 8.7 9.0 9.5 10.1
27ºC D
19ºC W
Pressure
( kg/cm2 )
8.0 8.5 9.2 9.9 10.2 10.8
32ºC D
23ºC W
Pressure
( kg/cm2 )
8.8 9.1 9.2 10.0 10.5 11.2
Heating mode
OUTDOOR CONDITIONS
Indoor Conditions
Pressure
12ºC D
11ºC W
7ºC D
6ºC W
0ºC D
-1ºC W
-
4ºC D
-6ºC W
-7ºC D
-9ºC W
-15ºC D
-xºC W
15ºC
Pressure
( kg/cm2 )
26.5 25.0 22.0 21.5 20.5 /
18ºC
Pressure
( kg/cm2 )
27.0 26.0 23.5 22.5 20.8 /
20ºC
Pressure
( kg/cm2 )
27.5 26.5 25.0 23.0 21.0 /
22ºC
Pressure
( kg/cm
2
)
28.5 27.0 25.5 23.9 21.5 /
Loading...