Lennox Elite XC16-024, Elite XC16, Elite XC16-036, Elite XC16-048, Elite XC16-060 User Manual

Page 1
E N G I N E E R I N G D A TA
A I R C O N D T I O N E R S
XC16
ELITE® Series
R-410A - Two-Stage Compressor
Bulletin No. 210465
October 2010

MODEL NUMBER IDENTIFICATION

X C 16 - 036 - 230 - 2
Refrigerant Type
X = R-410A
Unit Type
C = Air Conditioner
Series
SEER up to 17.20
2 to 5 Tons
Cooling Capacity - 24,600 to 60,000 Btuh
Minor Revision Number
Voltage
230 = 208/230V-1phase-60hz
Nominal Cooling Capacity
024 = 2 tons 036 = 3 tons 048 = 4 tons 060 = 5 tons
Page 2

FEATURES

Contents
AHRI System Matches..................................................9
Dimensions ...................................................................7
Electrical Data ..............................................................5
Features........................................................................2
Field Wiring ..................................................................6
Installation Clearances .................................................6
Model Number Identication .........................................1
Optional Accessories ....................................................5
Outdoor Sound Data .....................................................6
Specications ...............................................................5
H
B
G
Equipment Warranty
Compressor - limited warranty for ten years in residential installations and ve years in non-residential installations. All other covered components - ve years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certicate included with unit for specic details.
ApplicationS
SEER up to 17.20. 2 through 5 ton. Single phase power supply. Sound levels as low as 74 dB. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches. See Indoor Coils and Air Handlers tab sections for data. Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation. Installer must set air conditioner, connect refrigerant lines, and make electrical connections to complete job.
Approvals
Certied in accordance with USE certication program which is based on AHRI Standard 210/240-2008. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. Air conditioners and components within bonded for grounding to meet safety standards for servicing required by UL and CEC. Units are UL and ULC listed. ISO 9001 Registered Manufacturing Quality System. EnErgy Star® certied units are designed to use less energy, help save money on utility bills, and help protect the environment.
For expanded ratings, see www.lennoxdavenet.com.
XC16 - 2 to 5 Ton Air Conditioner / Page 2
C
D
F
E
J
REFRIGERATION SYSTEM
R-410A Refrigerant
Non-chlorine, ozone friendly, R-410A. Unit pre-charged with refrigerant. See Specication table.
Outdoor Coil Fan
B
Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion Fan guard constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel. Fan service access accomplished by removal of fan guard.
Copper Tube/Enhanced Fin Coil
C
Lennox designed and fabricated coil. Ripple-edged aluminum ns. Copper tube construction. Lanced ns provide maximum exposure of n surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning.
I
A
Page 3
FEATURES
REFRIGERATION SYSTEM (CONTINUED)
High Pressure Switch
D
Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Manual reset.
Low Pressure Switch
E
Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset.
Hi-Capacity Liquid Line Drier
F
Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular-sieve bead type drier.
OPTIONS
Expansion Valve Kits
Must be ordered extra and eld installed on certain indoor units. See TXV Usage table.
Chatleff style tting.
Freezestat
Installs on or near the discharge line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it’s setpoint. Opens at 29°F and closes at 58°F.
Refrigerant Line Kits
Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory. Suction line fully insulated. L15 lines are stubbed at both ends. See Specications table for selection. Not available for -060 model and must be eld fabricated.
COMPRESSOR
Copeland Scroll Ultra Tech™ Two-Stage Compressor
G
Compressor features high efciency with uniform suction ow, constant discharge ow and high volumetric efciency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.
When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the xed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous ank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efciency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged.
On the xed scroll there are two bypass ports in the rst suction pocket. On the outside of the xed scroll there is a “slider ring” that is controlled by an internal solenoid that will rotate and cover the bypass ports. When the thermostat calls for rst-stage cooling, the bypass ports are open and
the compressor operates at 67% capacity, creating more cost-effective and efcient compressor operation. The bypassed refrigerant is returned to the compressor housing through the bypass ports. When the thermostat calls for second-stage cooling, the internal solenoid is energized, the slider ring rotates and covers the bypass ports, and the compressor operates at full capacity. Low gas pulses during compression reduces operational sound levels.
XC16 - 2 to 5 Ton Air Conditioner / Page 3
Page 4
FEATURES
COMPRESSOR (CONTINUED)
Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on specially formulated, resilient rubber mounts for better sound dampening and vibration free operation.
Crankcase Heater (048-060 models only)
Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication.
OPTIONS
Crankcase Heater (Optional for 024-036 models)
Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication.
Compressor Hard Start Kit
Single-phase units are equipped with a PSC compressor motor. This type of motor normally does not need a potential relay and start capacitor. In conditions such as low voltage, kit may be required to increase the compressor starting torque. Hard start kit is required in applications where the supply voltage is less than 230V.
CONTROLS
OPTIONS
HOME SCHEDULE OPTIONS
MODE
AUTO
ON
SCHED
INDOOR RH 26%
WED AN 21 12:35AM
SETAT
HEAT
SETAT
COOL
ComfortSense® 7000 Touchscreen Thermostat
Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/2 Cool. Auto-changeover. Controls humidity during cooling mode. Offers enhanced capabilities including humidication / dehumidication / dewpoint measurement and control, Humiditrol® control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual fuel and Humiditrol® applications. See the ComfortSense 7000 Engineering Handbook bulletin in the Controls section for more information.
Indoor Blower Off Delay Relay
Delays the indoor blower-off time during the cooling cycle. See AHRI System Matches for usage.
Indoor Blower Speed Relay
Relay kit provides optimum humidity control conditions by automatically reducing indoor blower speed during continuous fan or rst-stage compressor operation.
Low Ambient Kit
Air conditioner will operate satisfactorily down to 45°F outdoor air temperature without any additional controls. Kit can be added in the eld enabling unit to operate properly down to 30°F. A Freezestat should be installed on compressors equipped with a low ambient kit. A Compressor Low Ambient Cut-Off should be added to terminate compressor operation below recommended operation conditions.
Thermostat
Thermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book.
CAbinet
Heavy-gauge steel construction
H
Pre-painted cabinet nish. Painted base section. Control box is conveniently located with all controls factory wired. Large removable panel provides service access. Drainage holes are provided in base section for moisture removal. High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture.
SmartHinge™ Louvered Coil Protection
I
Steel louvered panels provides complete coil protection. Panels are hinged to allow easy cleaning and servicing of coils. Panels may be completely removed. Interlocking tabs and slots assure tight t on cabinet.
Refrigerant Line Connections, Electrical Inlets and
J
Service Valves
Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and eld wiring inlets are located in one central area of the cabinet. See dimension drawing.
XC16 - 2 to 5 Ton Air Conditioner / Page 4
Page 5

SPECIFICATIONS

General Data
Connections (sweat)
Refrigerant Outdoor
Net face area - sq. ft. Outer coil 21.00 24.5 21.00 24.93
Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8
Suction line (o.d.) - in. 3/4 7/8 7/8 1-1/8
1
R-410A charge furnished 7 lbs. 6 oz. 8 lbs. 8 oz. 11 lbs. 4 oz. 14 lbs. 2 oz.
Coil
Tube diameter - in. 5/16 5/16 5/16 5/16
Outdoor Fan
Shipping Data - lbs. 1 pkg. 230 249 268 323

ELECTRICAL DATA

Line voltage data - 60hz
2
Maximum overcurrent protection (amps) 20 35 45 60
3
Minimum circuit ampacity 13.6 22.0 28.2 33.9
Compressor Rated load amps 10.3 16.7 21.2 25.9
Locked rotor amps 52 82 96 118
Outdoor Fan Motor
Locked Rotor amps 2.1 2.1 3.1 2.9
OPTIONAL ACCESSORIES - must be ordered extra
ComfortSense® 7000 Thermostat Y2081 Compressor Crankcase Heater 93M06
Outdoor Temperature Sensor - for
ComfortSense 7000 Thermostat Compressor Hard Start Kit - Required in
applications with less than 230V
Compressor Low Ambient Cut-Off 45F08 Compressor Time-Off Control 47J27 Freezestat 3/8 in. tubing 93G35
5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 Indoor Blower Speed Relay 40K58 Low Ambient Kit 34M72 Refrigerant
Line Sets
L15-41-20 L15-41-40 L15-41-30 L15-41-50
L15-65-30 L15-65-40
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufcient for 15 ft. length of refrigerant lines.
2
HACR type breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Hard start kit is required in applications where the supply voltage is less than 230V.
Model No. XC16-024 XC16-036 XC16-048 XC16-060
Nominal Tonnage 2 3 4 5
Inner coil - - - - - - 20.27 24.14
No. of rows 1 1 2 2
Fins per inch 26 26 22 22
Diameter - in. 22 22 22 26
No. of blades 4 4 4 3
Motor hp 1/6 1/6 1/4 1/3
Cfm 3230 3260 3955 4380
Rpm 840 840 835 850
Watts 215 220 320 280
4
230V-1ph
4
230V-1ph
4
230V-1ph
4
230V-1ph
Power factor 0.98 0.99 0.99 0.99
Full load amps 1.1 1.1 1.7 1.8
 
Factory
X2658
10J42 81J69
               
L15-65-50
Field Fabricate
XC16 - 2 to 5 Ton Air Conditioner / Page 5
Page 6

OUTDOOR SOUND DATA

Octave Band Sound Power Levels dBA, re 10-12 Watts
1
Unit
Model No.
XC16-024
XC16-036
XC16-048
XC16-060
NOTE - the octave sound power data does not include tonal correction.
1
Tested according to AHRI Standard 270-2008 test conditions.
63 125 250 500 1000 2000 4000 8000
50 55 62 67 68.5 65.5 63 58.5 74
50.5 54.5 61 68 67 63 63 59.5 76
81.5 72 72 72.5 68.5 64.5 59.5 56.5 76
79 71 70.5 76.5 71 65 61.5 57.5 78

FIELD WIRING

Center Frequency - HZ
1
Sound
Rating
Number
(dB)
DISCONNECT
SWITCH
(By Others)
THERMOSTAT
(Optional)
B
D
DISCONNECT
SWITCH
(By Others)
A
A - Two Wire Power (not furnished) B - Two Power (not furnished). See Electrical Data C - Four Wire Low Voltage (not furnished). 18 ga. minimum D - Six Wire Low Voltage (not furnished). 18 ga. minimum
C
LENNOX
AIR
CONDITIONER
LENNOX
HEATING UNIT
OR
AIR HANDLER
UNIT
INSTALLATION CLEARANCES - INCHES (MM)
See NOTES
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box.
All wiring must conform to NEC or CEC and local electrical codes.
See
NOTES
See NOTES
XC16 - 2 to 5 Ton Air Conditioner / Page 6
See
NOTES
Control
Box
Clearance to one of the other three sides must be 36 in. (914 mm)
Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. (610 mm) must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
Page 7
DIMENSIONS - INCHES (MM)
(216)
TOP VIEW
DISCHARGE AIR
SUCTION LINE CONNECTION
LIQUID LINE
CONNECTION
BC
LIQUID LINE CONNECTION
UNIT SUPPORT FEET
8−1/2
8−3/4 (222)
5−1/2 (140)
4−1/4(108)
SIDE VIEW
13−1/2
(343)
XC16-024 BASE SECTION
ELECTRICAL INLETS
SUCTION LINE CONNECTION
4−3/4 (121)
9−1/2 (241)
8−1/4 (210)
A
2 (51)
UNIT SUPPORT FEET
D
E
1 (25)
F
END VIEW
G
H
XC16-036 TO -060 BASE SECTION
K
J
Model No.
A B C D E F G H J K
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
XC16-024 39 991 30-1/2 775 35 889 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
XC16-036 45 1143 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524
XC16-048 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524
XC16-060 39 991 35-1/2 902 39-1/2 1003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683
XC16 - 2 to 5 Ton Air Conditioner / Page 7
Page 8
TXV USAGE
Model No. Order No.
XC16-024 37L51
XC16-036 37L51
XC16-048 91M02
XC16-060 91M02
CX34 upow coils and all Lennox air handlers (except CB26UH “R”) are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the “TXV SUBSTITUTIONS” table. The correct TXV must be ordered and eld installed. C33 coils and all horizontal and downow coils are shipped without a TXV. The TXV must be ordered and eld installed.
MOST POPULAR MATCHES
Outdoor Unit Model No.
XC16-024 CX34-36B with SL280UH090V36B
XC16-036 CX34-43C with SL280UH090V60C
XC16-048 CX34-62C with SL280UH090V60C
XC16-060 CX34-62C with SL280UH090V60C
Indoor Unit Model No
*tXV SUBSTITUTIONS
Indoor Coils/Air Handlers with factory installed expansion valves that require eld replacement
Model No.
XC16-024 CBX26UH-024 37L51
XC16-036 CX34-42 37L51
XC16-036 CX34-43 37L51
XC16-036 CX34-44/48 37L51
XC16-036 CX34-49 37L51
XC16-036 CBX26UH-030 37L51
XC16-036 CBX27UH-072 37L51
XC16-036 CBX32M-042 37L51
XC16-036 CBX32MV-024/030 37L51
XC16-036 CBX32MV-048 37L51
XC16-036 CBX40UHV-030 37L51
XC16-036 CBX40UHV-042 37L51
XC16-036 CBX40UHV-048 37L51
XC16-048 CX34-44/48 91M02
XC16-048 CBX26UH-042 91M02
* Factory installed expansion valve on the indoor coil or air handler shown must
be replaced with the expansion valve listed (ordered separately).
Indoor Coil or Air Handler
Order No.
XC16 - 2 to 5 Ton Air Conditioner / Page 8
Page 9

AHRI SYSTEM MATCHES

NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-024-230 TXV 25,200 14.20 11.70 CH23-41 3068768
XC16-024-230 TXV 25,400 16.50 13.00 CH33-19 SL280UH070V36A 3932948
XC16-024-230 TXV 25,400 16.50 13.00 CH33-19 SL280UH070XV36A 4037910
XC16-024-230 TXV 24,800 14.00 11.50 CH33-19 3068769
XC16-024-230 TXV 25,200 16.20 12.70 CH33-24/30 SL280UH070V36A 3932949
XC16-024-230 TXV 25,200 16.20 12.70 CH33-24/30 SL280UH070XV36A 4037911
XC16-024-230 TXV 24,600 14.00 11.50 CH33-24/30 3068843
XC16-024-230 TXV 25,800 16.70 13.00 CH33-25 SL280UH070V36A 3932950
XC16-024-230 TXV 25,800 16.70 13.00 CH33-25 SL280UH070XV36A 4037912
XC16-024-230 TXV 25,600 16.00 13.20 CH33-25 SL280UH090V36B 3932951
XC16-024-230 TXV 25,600 16.00 13.00 CH33-25 SL280UH090V48B 4249273
XC16-024-230 TXV 25,800 16.20 13.20 CH33-25 SLP98UH070V36B 4020625
XC16-024-230 TXV 25,400 14.50 11.70 CH33-25A 3068772
XC16-024-230 TXV 25,800 16.50 13.00 CH33-25B G61MPV-36B-045 3068821
XC16-024-230 TXV 25,800 16.50 13.00 CH33-25B G61MPV-36B-070 3068822
XC16-024-230 TXV 26,000 16.50 13.00 CH33-25B G61MPV-36B-071 3068824
XC16-024-230 TXV 25,200 14.20 11.70 CH33-25B 3068773
XC16-024-230 TXV 26,400 17.00 13.20 CH33-31 SL280UH070V36A 3932952
XC16-024-230 TXV 26,400 17.00 13.20 CH33-31 SL280UH070XV36A 4037913
XC16-024-230 TXV 26,200 16.50 13.50 CH33-31 SL280UH090V36B 3932953
XC16-024-230 TXV 26,200 16.50 13.20 CH33-31 SL280UH090V48B 4249274
XC16-024-230 TXV 26,400 16.70 13.50 CH33-31 SLP98UH070V36B 4020626
XC16-024-230 TXV 25,800 14.70 12.00 CH33-31A 3068774
XC16-024-230 TXV 26,400 16.70 13.20 CH33-31B G61MPV-36B-045 3068827
XC16-024-230 TXV 26,400 16.70 13.20 CH33-31B G61MPV-36B-070 3068828
XC16-024-230 TXV 26,600 17.00 13.20 CH33-31B G61MPV-36B-071 3068830
XC16-024-230 TXV 25,800 14.50 12.00 CH33-31B 3068775
XC16-024-230 TXV 25,600 16.50 13.00 CH33-36 SL280UH070V36A 3932954
XC16-024-230 TXV 25,600 16.50 13.00 CH33-36 SL280UH070XV36A 4037914
XC16-024-230 TXV 25,600 16.00 13.20 CH33-36 SL280UH090V36B 3932955
XC16-024-230 TXV 25,600 16.20 13.20 CH33-36 SLP98UH070V36B 4020627
XC16-024-230 TXV 25,200 14.20 11.70 CH33-36A 3068770
XC16-024-230 TXV 25,800 16.20 13.00 CH33-36B G61MPV-36B-045 3068833
XC16-024-230 TXV 25,800 16.50 13.00 CH33-36B G61MPV-36B-070 3068834
XC16-024-230 TXV 25,800 16.50 13.00 CH33-36B G61MPV-36B-071 3068836
XC16-024-230 TXV 25,000 14.20 11.70 CH33-36B 3068771
XC16-024-230 TXV 26,200 16.50 13.00 CH33-36C SLP98UH090V36C 4231106
XC16-024-230 TXV 26,200 16.70 13.20 CR33-30/36 G61MPV-36B-045 3068810
XC16-024-230 TXV 26,200 16.70 13.20 CR33-30/36 G61MPV-36B-070 3068811
XC16-024-230 TXV 26,200 16.70 13.20 CR33-30/36 G61MPV-36B-071 3068813
XC16-024-230 TXV 26,400 16.50 13.20 CR33-30/36 SL280DF070V36A 3932956
XC16-024-230 TXV 26,200 16.70 13.20 CR33-30/36 SLP98DF070V36B 4020628
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 9
Page 10
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-024-230 TXV 26,200 16.70 13.50 CR33-30/36 SLP98DF090V36C 4020629
XC16-024-230 TXV 25,400 14.50 11.70 CR33-30/36 3068766
XC16-024-230 TXV 25,200 15.70 12.70 CX34-18/24 CBWMV-24B-040 3496087
XC16-024-230 TXV 24,600 15.70 12.50 CX34-18/24 SL280UH070V36A 3932957
XC16-024-230 TXV 24,600 15.70 12.50 CX34-18/24 SL280UH070XV36A 4037915
XC16-024-230 TXV 24,600 15.20 12.70 CX34-18/24 SL280UH090V36B 3932958
XC16-024-230 TXV 24,600 15.50 12.50 CX34-18/24 SLP98UH070V36B 4020630
XC16-024-230 TXV 24,800 14.20 11.50 CX34-18/24 3493256
XC16-024-230 TXV 25,600 16.70 13.20 CX34-19 SL280UH070V36A 3932959
XC16-024-230 TXV 25,600 16.70 13.20 CX34-19 SL280UH070XV36A 4037916
XC16-024-230 TXV 24,800 14.20 11.50 CX34-19 3068761
XC16-024-230 TXV 26,000 16.50 13.00 CX34-25 G61MPV-36B-045 3068779
XC16-024-230 TXV 25,800 16.50 13.00 CX34-25 G61MPV-36B-070 3068780
XC16-024-230 TXV 25,800 16.70 13.00 CX34-25 SL280UH070V36A 3932960
XC16-024-230 TXV 25,800 16.70 13.00 CX34-25 SL280UH070XV36A 4037917
XC16-024-230 TXV 25,600 16.00 13.00 CX34-25 SL280UH090V36B 3932961
XC16-024-230 TXV 25,600 16.20 13.00 CX34-25 SL280UH090V48B 4249269
XC16-024-230 TXV 25,800 16.20 13.20 CX34-25 SLP98UH070V36B 4020631
XC16-024-230 TXV 25,200 14.20 11.70 CX34-25 3068762
XC16-024-230 TXV 25,200 15.70 12.50 CX34-30 G61MPV-36B-045 3068784
XC16-024-230 TXV 25,200 15.70 12.70 CX34-30 G61MPV-36B-070 3068785
XC16-024-230 TXV 25,200 16.00 12.50 CX34-30 G61MPV-36B-071 3068787
XC16-024-230 TXV 25,000 16.00 12.70 CX34-30 G61MPV-36C-090 3068844
XC16-024-230 TXV 26,400 16.70 13.20 CX34-31 G61MPV-36B-045 3068790
XC16-024-230 TXV 26,200 16.70 13.20 CX34-31 G61MPV-36B-070 3068791
XC16-024-230 TXV 26,400 16.70 13.20 CX34-31 G61MPV-36B-071 3068793
XC16-024-230 TXV 26,200 17.00 13.20 CX34-31 SL280UH070V36A 3932962
XC16-024-230 TXV 26,200 17.00 13.20 CX34-31 SL280UH070XV36A 4037918
XC16-024-230 TXV 26,000 16.50 13.20 CX34-31 SL280UH090V36B 3932963
XC16-024-230 TXV 26,000 16.50 13.20 CX34-31 SL280UH090V48B 4249270
XC16-024-230 TXV 26,200 16.70 13.50 CX34-31 SLP98UH070V36B 4020632
XC16-024-230 TXV 25,600 14.50 12.00 CX34-31 3068763
XC16-024-230 TXV 25,200 15.50 12.70 CX34-36 CBWMV-24B-040 3493247
XC16-024-230 TXV 25,800 16.50 13.00 CX34-36 G61MPV-36B-045 3068796
XC16-024-230 TXV 25,800 16.50 13.00 CX34-36 G61MPV-36B-070 3068797
XC16-024-230 TXV 25,800 16.50 13.00 CX34-36 G61MPV-36B-071 3068799
XC16-024-230 TXV 25,600 16.50 13.20 CX34-36 G61MPV-36C-090 3068800
XC16-024-230 TXV 25,800 16.70 13.20 CX34-36 SL280UH070V36A 3932964
XC16-024-230 TXV 25,800 16.70 13.20 CX34-36 SL280UH070XV36A 4037919
XC16-024-230 TXV 25,600 16.00 13.20 CX34-36 SL280UH090V36B 3932965
XC16-024-230 TXV 25,600 16.20 13.20 CX34-36 SLP98UH070V36B 4020633
XC16-024-230 TXV 25,600 16.50 13.20 CX34-36 SLP98UH090V36C 4237077
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 10
Page 11
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-024-230 TXV 24,600 13.70 11.50 CX34-36 3068764
XC16-024-230 TXV 26,600 16.70 13.20 CX34-38 G61MPV-36B-045 3068804
XC16-024-230 TXV 26,400 17.00 13.20 CX34-38 G61MPV-36B-070 3068805
XC16-024-230 TXV 26,600 17.00 13.20 CX34-38 G61MPV-36B-071 3068807
XC16-024-230 TXV 26,400 17.20 13.50 CX34-38 SL280UH070V36A 3932966
XC16-024-230 TXV 26,400 17.20 13.50 CX34-38 SL280UH070XV36A 4037920
XC16-024-230 TXV 26,200 16.50 13.50 CX34-38 SL280UH090V36B 3932967
XC16-024-230 TXV 26,200 16.50 13.20 CX34-38 SL280UH090V48B 4249271
XC16-024-230 TXV 26,400 16.70 13.50 CX34-38 SLP98UH070V36B 4020634
XC16-024-230 TXV 25,400 14.20 11.70 CX34-38 3068765
XC16-036-230 TXV 34,400 15.50 11.20 C33-36 CBWMV-36C-090 3184066
XC16-036-230 TXV 34,200 15.20 11.00 C33-36 G61MPV-36B-045 3069107
XC16-036-230 TXV 34,400 15.50 11.00 C33-36 G61MPV-36B-070 3069108
XC16-036-230 TXV 34,200 15.20 11.00 C33-36 G61MPV-36B-071 3069110
XC16-036-230 TXV 34,200 15.50 11.50 C33-36 G61MPV-36C-090 3069111
XC16-036-230 TXV 34,200 15.50 11.20 C33-36 SL280UH070V36A 3932968
XC16-036-230 TXV 34,200 15.50 11.20 C33-36 SL280UH070XV36A 4037922
XC16-036-230 TXV 34,400 15.70 11.50 C33-36 SL280UH090V36B 3932969
XC16-036-230 TXV 34,400 15.50 11.50 C33-36 SL280UH090V48B 3932970
XC16-036-230 TXV 34,800 15.70 11.70 C33-36 SL280UH090V60C 3932971
XC16-036-230 TXV 34,400 15.50 11.50 C33-36 SL280UH090XV48B 4038663
XC16-036-230 TXV 34,800 15.70 11.70 C33-36 SL280UH090XV60C 4235446
XC16-036-230 TXV 34,600 15.70 11.50 C33-36 SL280UH110V60C 3932972
XC16-036-230 TXV 34,600 15.70 11.50 C33-36 SL280UH110XV60C 4040506
XC16-036-230 TXV 33,800 13.70 10.70 C33-36 3069097
XC16-036-230 TXV 35,600 16.00 11.20 C33-38 G61MPV-36B-045 3069115
XC16-036-230 TXV 35,400 16.00 11.50 C33-38 G61MPV-36B-070 3069116
XC16-036-230 TXV 35,400 16.00 11.50 C33-38 G61MPV-36B-071 3069118
XC16-036-230 TXV 35,600 16.00 11.50 C33-38 SL280UH070V36A 3932973
XC16-036-230 TXV 35,600 16.00 11.50 C33-38 SL280UH070XV36A 4037923
XC16-036-230 TXV 35,800 16.20 11.70 C33-38 SL280UH090V36B 3932974
XC16-036-230 TXV 35,800 16.00 12.00 C33-38 SL280UH090V48B 3932975
XC16-036-230 TXV 35,800 16.00 12.00 C33-38 SL280UH090XV48B 4038664
XC16-036-230 TXV 34,600 14.00 10.90 C33-38 3069098
XC16-036-230 TXV 34,200 15.20 11.00 C33-42 G61MPV-36B-045 3069120
XC16-036-230 TXV 34,000 15.20 11.00 C33-42 G61MPV-36B-070 3069121
XC16-036-230 TXV 34,000 15.20 11.00 C33-42 G61MPV-36B-071 3069123
XC16-036-230 TXV 34,400 15.70 11.50 C33-42 SL280UH090V36B 3932976
XC16-036-230 TXV 34,400 15.50 11.50 C33-42 SL280UH090V48B 3932977
XC16-036-230 TXV 34,400 15.50 11.50 C33-42 SL280UH090XV48B 4038665
XC16-036-230 TXV 33,800 13.70 10.70 C33-42 3069099
XC16-036-230 TXV 35,800 16.00 11.70 C33-43 CBWMV-36C-090 3184068
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 11
Page 12
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-036-230 TXV 35,600 16.00 11.50 C33-43 G61MPV-36B-045 3069126
XC16-036-230 TXV 35,400 16.00 11.50 C33-43 G61MPV-36B-070 3069127
XC16-036-230 TXV 35,400 16.20 12.00 C33-43 G61MPV-36C-090 3069129
XC16-036-230 TXV 36,200 16.20 12.00 C33-43 G61MPV-60C-090 3069131
XC16-036-230 TXV 36,200 16.20 11.70 C33-43 G61MPV-60C-091 3069133
XC16-036-230 TXV 36,200 16.00 12.00 C33-43 G61MPV-60C-110 3069134
XC16-036-230 TXV 36,200 16.20 12.00 C33-43 G61MPV-60C-111 3069136
XC16-036-230 TXV 36,000 16.20 11.70 C33-43 SL280UH090V36B 3932978
XC16-036-230 TXV 35,800 16.00 12.00 C33-43 SL280UH090V48B 3932979
XC16-036-230 TXV 36,400 16.50 12.00 C33-43 SL280UH090V60C 3932980
XC16-036-230 TXV 35,800 16.00 12.00 C33-43 SL280UH090XV48B 4038666
XC16-036-230 TXV 36,400 16.50 12.00 C33-43 SL280UH090XV60C 4235447
XC16-036-230 TXV 36,000 16.20 12.00 C33-43 SL280UH110V60C 3932981
XC16-036-230 TXV 36,000 16.20 12.00 C33-43 SL280UH110XV60C 4040507
XC16-036-230 TXV 35,200 14.20 11.00 C33-43 3069100
XC16-036-230 TXV 35,200 16.00 11.70 C33-44C G61MPV-36C-090 3068698
XC16-036-230 TXV 35,600 16.20 11.70 C33-44C G61MPV-60C-090 3068700
XC16-036-230 TXV 35,800 16.00 11.50 C33-44C G61MPV-60C-091 3068702
XC16-036-230 TXV 35,600 15.70 11.70 C33-44C G61MPV-60C-110 3068703
XC16-036-230 TXV 35,600 16.20 11.70 C33-44C G61MPV-60C-111 3068705
XC16-036-230 TXV 35,200 15.70 11.20 C33-48 G61MPV-36B-045 3069140
XC16-036-230 TXV 35,000 15.70 11.50 C33-48 G61MPV-36B-070 3069141
XC16-036-230 TXV 35,200 15.70 11.20 C33-48 G61MPV-36B-071 3069143
XC16-036-230 TXV 35,200 16.00 11.70 C33-48 G61MPV-36C-090 3069144
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 G61MPV-60C-090 3069146
XC16-036-230 TXV 35,800 16.00 11.50 C33-48 G61MPV-60C-091 3069148
XC16-036-230 TXV 35,600 15.70 11.70 C33-48 G61MPV-60C-110 3069149
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 G61MPV-60C-111 3069151
XC16-036-230 TXV 35,400 16.00 11.70 C33-48 SL280UH090V36B 3932982
XC16-036-230 TXV 35,400 15.70 11.70 C33-48 SL280UH090V48B 3932983
XC16-036-230 TXV 35,800 16.20 11.70 C33-48 SL280UH090V60C 3932984
XC16-036-230 TXV 35,400 15.70 11.70 C33-48 SL280UH090XV48B 4038667
XC16-036-230 TXV 35,800 16.20 11.70 C33-48 SL280UH090XV60C 4235448
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 SL280UH110V60C 3932985
XC16-036-230 TXV 35,600 16.00 11.70 C33-48 SL280UH110XV60C 4040508
XC16-036-230 TXV 34,800 14.20 10.90 C33-48 3069101
XC16-036-230 TXV 36,600 16.70 12.20 C33-49 SL280UH090V60C 3932986
XC16-036-230 TXV 36,600 16.70 12.20 C33-49 SL280UH090XV60C 4235449
XC16-036-230 TXV 36,400 16.20 12.00 C33-49 SL280UH110V60C 3932987
XC16-036-230 TXV 36,400 16.20 12.00 C33-49 SL280UH110XV60C 4040509
XC16-036-230 TXV 35,600 14.50 11.00 C33-49 3069102
XC16-036-230 TXV 34,800 14.70 11.20 CB26UH-030 3069152
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 12
Page 13
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-036-230 TXV 35,200 14.70 11.20 CB26UH-036 3069153
XC16-036-230 TXV 34,800 14.70 11.20 CBX26UH-030 3068746
XC16-036-230 TXV 35,200 14.70 11.20 CBX26UH-036 3068747
XC16-036-230 TXV 35,000 15.70 11.70 CBX27UH-036 3068754
XC16-036-230 TXV 36,000 16.50 12.00 CBX27UH-042 3068755
XC16-036-230 TXV 34,200 15.00 11.00 CBX32M-030 3068748
XC16-036-230 TXV 34,400 14.70 11.00 CBX32M-036 3068749
XC16-036-230 TXV 34,600 14.70 11.20 CBX32M-042 3068750
XC16-036-230 TXV 34,400 15.50 11.20 CBX32MV-024/030 3068751
XC16-036-230 TXV 35,000 16.00 11.50 CBX32MV-036 3068752
XC16-036-230 TXV 36,000 16.50 12.00 CBX32MV-048 3068753
XC16-036-230 TXV 34,400 15.50 11.20 CBX40UHV-030 3291635
XC16-036-230 TXV 35,000 16.00 11.50 CBX40UHV-036 3291687
XC16-036-230 TXV 36,000 16.50 12.00 CBX40UHV-042 3291711
XC16-036-230 TXV 36,000 16.50 12.00 CBX40UHV-048 3291797
XC16-036-230 TXV 34,400 15.50 11.50 CH23-41 G61MPV-36B-070 3068714
XC16-036-230 TXV 34,600 16.00 11.70 CH23-41 SL280UH090V36B 3932988
XC16-036-230 TXV 34,800 15.70 11.70 CH23-41 SL280UH090V48B 3932989
XC16-036-230 TXV 35,400 16.20 12.00 CH23-41 SL280UH090V60C 3932990
XC16-036-230 TXV 34,800 15.70 11.70 CH23-41 SL280UH090XV48B 4038668
XC16-036-230 TXV 35,400 16.20 12.00 CH23-41 SL280UH090XV60C 4235450
XC16-036-230 TXV 35,000 16.00 11.70 CH23-41 SL280UH110V60C 3932991
XC16-036-230 TXV 35,000 16.00 11.70 CH23-41 SL280UH110XV60C 4040510
XC16-036-230 TXV 34,800 15.70 11.50 CH23-41 SLP98UH070V36B 4020635
XC16-036-230 TXV 34,800 16.00 11.70 CH23-41 SLP98UH090V36C 4020636
XC16-036-230 TXV 34,600 16.00 11.70 CH23-41 SLP98UH090V48C 4020637
XC16-036-230 TXV 35,400 16.20 11.70 CH23-41 SLP98UH090V60C 4020638
XC16-036-230 TXV 35,200 16.00 11.70 CH23-41 SLP98UH110V60C 4020639
XC16-036-230 TXV 34,200 13.70 10.80 CH23-41 3068640
XC16-036-230 TXV 35,800 16.50 12.00 CH23-65 SL280UH090V60C 3932992
XC16-036-230 TXV 35,800 16.50 12.00 CH23-65 SL280UH090XV60C 4235445
XC16-036-230 TXV 35,600 16.20 12.00 CH23-65 SL280UH110V60C 3932993
XC16-036-230 TXV 35,600 16.20 12.00 CH23-65 SL280UH110XV60C 4040505
XC16-036-230 TXV 35,400 16.20 11.70 CH23-65 SLP98UH090V36C 4020640
XC16-036-230 TXV 35,200 16.20 12.00 CH23-65 SLP98UH090V48C 4020641
XC16-036-230 TXV 35,800 16.20 11.70 CH23-65 SLP98UH090V60C 4020642
XC16-036-230 TXV 35,600 16.20 12.00 CH23-65 SLP98UH110V60C 4020643
XC16-036-230 TXV 34,600 14.00 10.90 CH23-65 3068641
XC16-036-230 TXV 34,000 15.20 11.00 CH33-36 SL280UH070V36A 3932994
XC16-036-230 TXV 34,000 15.20 11.00 CH33-36 SL280UH070XV36A 4037921
XC16-036-230 TXV 34,400 15.70 11.50 CH33-36 SL280UH090V36B 3932995
XC16-036-230 TXV 34,200 15.50 11.50 CH33-36 SL280UH090V48B 3932996
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 13
Page 14
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-036-230 TXV 35,200 16.00 11.70 CH33-36 SL280UH090V60C 3932997
XC16-036-230 TXV 34,200 15.50 11.50 CH33-36 SL280UH090XV48B 4038669
XC16-036-230 TXV 35,200 16.00 11.70 CH33-36 SL280UH090XV60C 4235451
XC16-036-230 TXV 35,000 15.70 11.70 CH33-36 SL280UH110V60C 3932998
XC16-036-230 TXV 35,000 15.70 11.70 CH33-36 SL280UH110XV60C 4040511
XC16-036-230 TXV 34,200 15.50 11.20 CH33-36 SLP98UH070V36B 4020644
XC16-036-230 TXV 34,800 15.70 11.70 CH33-36 SLP98UH090V36C 4020645
XC16-036-230 TXV 34,600 15.70 11.70 CH33-36 SLP98UH090V48C 4020646
XC16-036-230 TXV 35,200 16.00 11.50 CH33-36 SLP98UH090V60C 4020647
XC16-036-230 TXV 35,000 16.00 11.70 CH33-36 SLP98UH110V60C 4020648
XC16-036-230 TXV 32,600 13.00 10.30 CH33-36A 3068642
XC16-036-230 TXV 33,800 15.20 11.00 CH33-36B G61MPV-36B-045 3068717
XC16-036-230 TXV 33,800 15.20 11.20 CH33-36B G61MPV-36B-070 3068718
XC16-036-230 TXV 33,800 15.20 11.20 CH33-36B G61MPV-36B-071 3068720
XC16-036-230 TXV 33,800 13.70 10.70 CH33-36B 3068643
XC16-036-230 TXV 35,000 15.70 11.50 CH33-36C G61MPV-36C-090 3068722
XC16-036-230 TXV 34,200 14.00 10.80 CH33-36C 3068644
XC16-036-230 TXV 34,800 15.50 11.20 CH33-42 G61MPV-36B-045 3068725
XC16-036-230 TXV 34,800 15.50 11.20 CH33-42 G61MPV-36B-070 3068726
XC16-036-230 TXV 34,800 15.50 11.20 CH33-42 G61MPV-36B-071 3068728
XC16-036-230 TXV 35,400 15.70 11.70 CH33-42 SL280UH090V36B 3932999
XC16-036-230 TXV 35,200 15.70 11.70 CH33-42 SL280UH090V48B 3933000
XC16-036-230 TXV 35,200 15.70 11.70 CH33-42 SL280UH090XV48B 4038673
XC16-036-230 TXV 35,000 15.70 11.20 CH33-42 SLP98UH070V36B 4020649
XC16-036-230 TXV 34,600 14.20 10.90 CH33-42 3068645
XC16-036-230 TXV 36,600 16.20 12.00 CH33-43 SL280UH090V36B 3933001
XC16-036-230 TXV 36,400 16.20 12.00 CH33-43 SL280UH090V48B 3933002
XC16-036-230 TXV 36,400 16.50 12.00 CH33-43 SL280UH090V60C 3933003
XC16-036-230 TXV 36,400 16.20 12.00 CH33-43 SL280UH090XV48B 4038676
XC16-036-230 TXV 36,400 16.50 12.00 CH33-43 SL280UH090XV60C 4235452
XC16-036-230 TXV 36,200 16.20 12.00 CH33-43 SL280UH110V60C 3933004
XC16-036-230 TXV 36,200 16.20 12.00 CH33-43 SL280UH110XV60C 4040512
XC16-036-230 TXV 36,200 16.20 11.70 CH33-43 SLP98UH070V36B 4020650
XC16-036-230 TXV 36,000 16.20 12.00 CH33-43 SLP98UH090V36C 4020651
XC16-036-230 TXV 36,200 16.50 12.00 CH33-43 SLP98UH090V48C 4020652
XC16-036-230 TXV 36,400 16.50 12.00 CH33-43 SLP98UH090V60C 4020653
XC16-036-230 TXV 36,200 16.50 12.00 CH33-43 SLP98UH110V60C 4020654
XC16-036-230 TXV 35,800 16.00 11.50 CH33-43B G61MPV-36B-045 3068730
XC16-036-230 TXV 36,200 16.00 11.50 CH33-43B G61MPV-36B-070 3068731
XC16-036-230 TXV 36,000 16.00 11.50 CH33-43B G61MPV-36B-071 3068733
XC16-036-230 TXV 35,800 14.50 11.00 CH33-43B 3068646
XC16-036-230 TXV 35,400 16.20 12.00 CH33-43C G61MPV-36C-090 3068736
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 14
Page 15
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-036-230 TXV 35,400 14.50 11.00 CH33-43C 3068647
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-045 3068738
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-070 3068739
XC16-036-230 TXV 35,200 15.70 11.50 CH33-44/48 G61MPV-36B-071 3068741
XC16-036-230 TXV 35,800 16.00 11.70 CH33-44/48 SL280UH090V36B 3933005
XC16-036-230 TXV 35,600 15.70 11.70 CH33-44/48 SL280UH090V48B 3933006
XC16-036-230 TXV 35,600 15.70 11.70 CH33-44/48 SL280UH090XV48B 4038680
XC16-036-230 TXV 35,600 15.70 11.50 CH33-44/48 SLP98UH070V36B 4020655
XC16-036-230 TXV 35,200 14.20 11.00 CH33-44/48 3068648
XC16-036-230 TXV 36,200 16.50 12.00 CH33-48 SL280UH090V60C 3933007
XC16-036-230 TXV 36,200 16.50 12.00 CH33-48 SL280UH090XV60C 4235453
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SL280UH110V60C 3933008
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SL280UH110XV60C 4040513
XC16-036-230 TXV 35,800 16.20 11.70 CH33-48 SLP98UH090V36C 4020656
XC16-036-230 TXV 36,000 16.50 11.70 CH33-48 SLP98UH090V48C 4020657
XC16-036-230 TXV 36,200 16.20 11.70 CH33-48 SLP98UH090V60C 4020658
XC16-036-230 TXV 36,000 16.20 12.00 CH33-48 SLP98UH110V60C 4020659
XC16-036-230 TXV 35,200 14.20 11.00 CH33-48 3068649
XC16-036-230 TXV 35,600 16.20 11.70 CH33-48C G61MPV-36C-090 3068744
XC16-036-230 TXV 34,400 15.20 11.00 CR33-30/36 G61MPV-36B-045 3068708
XC16-036-230 TXV 34,400 15.50 11.20 CR33-30/36 G61MPV-36B-070 3068709
XC16-036-230 TXV 34,200 15.50 11.00 CR33-30/36 G61MPV-36B-071 3068711
XC16-036-230 TXV 34,600 15.50 11.50 CR33-30/36 G61MPV-36C-090 3068712
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 G61MPV-60C-090 4207541
XC16-036-230 TXV 34,600 15.50 11.20 CR33-30/36 SL280DF070V36A 3933009
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SL280DF090V48B 3933010
XC16-036-230 TXV 35,200 16.00 11.70 CR33-30/36 SL280DF090V60C 3933011
XC16-036-230 TXV 35,000 16.00 11.70 CR33-30/36 SL280DF110V60C 3933012
XC16-036-230 TXV 34,400 15.50 11.20 CR33-30/36 SLP98DF070V36B 4020660
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 SLP98DF090V36C 4020661
XC16-036-230 TXV 34,800 15.70 11.50 CR33-30/36 SLP98DF090V48C 4020662
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SLP98DF090V60C 4020663
XC16-036-230 TXV 34,800 15.70 11.20 CR33-30/36 SLP98DF110V60C 4020664
XC16-036-230 TXV 34,200 14.00 10.70 CR33-30/36 3068638
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SL280DF090V48B 3933013
XC16-036-230 TXV 35,200 15.70 11.70 CR33-48 SL280DF090V60C 3933014
XC16-036-230 TXV 34,800 16.00 11.70 CR33-48 SL280DF110V60C 3933015
XC16-036-230 TXV 34,400 15.70 11.50 CR33-48 SLP98DF070V36B 4020665
XC16-036-230 TXV 34,600 15.70 11.50 CR33-48 SLP98DF090V36C 4020666
XC16-036-230 TXV 34,800 15.70 11.70 CR33-48 SLP98DF090V48C 4020667
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SLP98DF090V60C 4020668
XC16-036-230 TXV 34,800 15.70 11.50 CR33-48 SLP98DF110V60C 4020669
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 15
Page 16
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-036-230 TXV 34,000 13.70 10.70 CR33-48 3068639
XC16-036-230 TXV 34,400 15.50 11.20 CX34-36 CBWMV-36C-090 3184067
XC16-036-230 TXV 34,200 15.20 11.00 CX34-36 G61MPV-36B-045 3068653
XC16-036-230 TXV 34,400 15.50 11.00 CX34-36 G61MPV-36B-070 3068654
XC16-036-230 TXV 34,200 15.20 11.00 CX34-36 G61MPV-36B-071 3068656
XC16-036-230 TXV 34,200 15.50 11.50 CX34-36 G61MPV-36C-090 3068657
XC16-036-230 TXV 34,200 15.50 11.20 CX34-36 SL280UH070V36A 3933016
XC16-036-230 TXV 34,200 15.50 11.20 CX34-36 SL280UH070XV36A 4037924
XC16-036-230 TXV 34,400 15.70 11.50 CX34-36 SL280UH090V36B 3933017
XC16-036-230 TXV 34,400 15.50 11.50 CX34-36 SL280UH090V48B 3933018
XC16-036-230 TXV 34,800 15.70 11.70 CX34-36 SL280UH090V60C 3933019
XC16-036-230 TXV 34,400 15.50 11.50 CX34-36 SL280UH090XV48B 4038684
XC16-036-230 TXV 34,800 15.70 11.70 CX34-36 SL280UH090XV60C 4235454
XC16-036-230 TXV 34,600 15.70 11.50 CX34-36 SL280UH110V60C 3933020
XC16-036-230 TXV 34,600 15.70 11.50 CX34-36 SL280UH110XV60C 4040514
XC16-036-230 TXV 34,200 15.50 11.20 CX34-36 SLP98UH070V36B 4020670
XC16-036-230 TXV 34,400 15.70 11.50 CX34-36 SLP98UH090V36C 4020671
XC16-036-230 TXV 34,600 15.70 11.50 CX34-36 SLP98UH090V48C 4020672
XC16-036-230 TXV 34,600 15.70 11.50 CX34-36 SLP98UH110V60C 4020673
XC16-036-230 TXV 33,800 13.70 10.70 CX34-36 3068632
XC16-036-230 TXV 35,600 16.00 11.20 CX34-38 G61MPV-36B-045 3068661
XC16-036-230 TXV 35,400 16.00 11.50 CX34-38 G61MPV-36B-070 3068662
XC16-036-230 TXV 35,400 16.00 11.50 CX34-38 G61MPV-36B-071 3068664
XC16-036-230 TXV 35,600 16.00 11.50 CX34-38 SL280UH070V36A 3933021
XC16-036-230 TXV 35,600 16.00 11.50 CX34-38 SL280UH070XV36A 4037925
XC16-036-230 TXV 35,800 16.20 11.70 CX34-38 SL280UH090V36B 3933022
XC16-036-230 TXV 35,800 16.00 12.00 CX34-38 SL280UH090V48B 3933023
XC16-036-230 TXV 35,800 16.00 12.00 CX34-38 SL280UH090XV48B 4038689
XC16-036-230 TXV 35,600 16.20 11.50 CX34-38 SLP98UH070V36B 4020674
XC16-036-230 TXV 34,600 14.00 10.90 CX34-38 3068633
XC16-036-230 TXV 34,200 15.20 11.00 CX34-42 G61MPV-36B-045 3068666
XC16-036-230 TXV 34,000 15.20 11.00 CX34-42 G61MPV-36B-070 3068667
XC16-036-230 TXV 34,000 15.20 11.00 CX34-42 G61MPV-36B-071 3068669
XC16-036-230 TXV 34,400 15.70 11.50 CX34-42 SL280UH090V36B 3933024
XC16-036-230 TXV 34,400 15.50 11.50 CX34-42 SL280UH090V48B 3933025
XC16-036-230 TXV 34,400 15.50 11.50 CX34-42 SL280UH090XV48B 4038694
XC16-036-230 TXV 34,200 15.50 11.20 CX34-42 SLP98UH070V36B 4020675
XC16-036-230 TXV 33,800 13.70 10.70 CX34-42 3068634
XC16-036-230 TXV 35,800 16.00 11.70 CX34-43 CBWMV-36C-090 3184069
XC16-036-230 TXV 35,600 16.00 11.50 CX34-43 G61MPV-36B-045 3068672
XC16-036-230 TXV 35,400 16.00 11.50 CX34-43 G61MPV-36B-070 3068673
XC16-036-230 TXV 35,400 16.20 12.00 CX34-43 G61MPV-36C-090 3068675
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 16
Page 17
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-036-230 TXV 36,200 16.20 12.00 CX34-43 G61MPV-60C-090 3068677
XC16-036-230 TXV 36,200 16.20 11.70 CX34-43 G61MPV-60C-091 3068679
XC16-036-230 TXV 36,200 16.00 12.00 CX34-43 G61MPV-60C-110 3068680
XC16-036-230 TXV 36,200 16.20 12.00 CX34-43 G61MPV-60C-111 3068682
XC16-036-230 TXV 36,000 16.20 11.70 CX34-43 SL280UH090V36B 3933026
XC16-036-230 TXV 35,800 16.00 12.00 CX34-43 SL280UH090V48B 3933027
XC16-036-230 TXV 36,400 16.50 12.00 CX34-43 SL280UH090V60C 3933028
XC16-036-230 TXV 35,800 16.00 12.00 CX34-43 SL280UH090XV48B 4038698
XC16-036-230 TXV 36,400 16.50 12.00 CX34-43 SL280UH090XV60C 4235455
XC16-036-230 TXV 36,000 16.20 12.00 CX34-43 SL280UH110V60C 3933029
XC16-036-230 TXV 36,000 16.20 12.00 CX34-43 SL280UH110XV60C 4040515
XC16-036-230 TXV 35,800 16.20 11.70 CX34-43 SLP98UH070V36B 4020676
XC16-036-230 TXV 35,800 16.20 11.70 CX34-43 SLP98UH090V36C 4020677
XC16-036-230 TXV 36,000 16.50 11.70 CX34-43 SLP98UH090V48C 4020678
XC16-036-230 TXV 36,200 16.20 11.70 CX34-43 SLP98UH090V60C 4020679
XC16-036-230 TXV 36,200 16.20 12.00 CX34-43 SLP98UH110V60C 4020680
XC16-036-230 TXV 35,200 14.20 11.00 CX34-43 3068635
XC16-036-230 TXV 35,200 15.70 11.20 CX34-44/48 G61MPV-36B-045 3068685
XC16-036-230 TXV 35,000 15.70 11.50 CX34-44/48 G61MPV-36B-070 3068686
XC16-036-230 TXV 35,200 15.70 11.20 CX34-44/48 G61MPV-36B-071 3068688
XC16-036-230 TXV 35,200 16.00 11.70 CX34-44/48 G61MPV-36C-090 3068689
XC16-036-230 TXV 35,600 16.00 11.70 CX34-44/48 G61MPV-60C-090 3068691
XC16-036-230 TXV 35,800 16.00 11.50 CX34-44/48 G61MPV-60C-091 3068693
XC16-036-230 TXV 35,600 15.70 11.70 CX34-44/48 G61MPV-60C-110 3068694
XC16-036-230 TXV 35,600 16.00 11.70 CX34-44/48 G61MPV-60C-111 3068696
XC16-036-230 TXV 35,400 16.00 11.70 CX34-44/48 SL280UH090V36B 3933030
XC16-036-230 TXV 35,400 15.70 11.70 CX34-44/48 SL280UH090V48B 3933031
XC16-036-230 TXV 35,800 16.20 11.70 CX34-44/48 SL280UH090V60C 3933032
XC16-036-230 TXV 35,400 15.70 11.70 CX34-44/48 SL280UH090XV48B 4038702
XC16-036-230 TXV 35,800 16.20 11.70 CX34-44/48 SL280UH090XV60C 4235456
XC16-036-230 TXV 35,600 16.00 11.70 CX34-44/48 SL280UH110V60C 3933033
XC16-036-230 TXV 35,600 16.00 11.70 CX34-44/48 SL280UH110XV60C 4040516
XC16-036-230 TXV 35,200 16.00 11.50 CX34-44/48 SLP98UH070V36B 4020681
XC16-036-230 TXV 35,400 16.00 11.70 CX34-44/48 SLP98UH090V36C 4020682
XC16-036-230 TXV 35,600 16.20 11.70 CX34-44/48 SLP98UH090V48C 4020683
XC16-036-230 TXV 35,800 16.20 11.70 CX34-44/48 SLP98UH090V60C 4020684
XC16-036-230 TXV 35,600 16.20 11.70 CX34-44/48 SLP98UH110V60C 4020685
XC16-036-230 TXV 34,800 14.20 10.90 CX34-44/48 3068636
XC16-036-230 TXV 36,600 16.70 12.20 CX34-49 SL280UH090V60C 3933034
XC16-036-230 TXV 36,600 16.70 12.20 CX34-49 SL280UH090XV60C 4235457
XC16-036-230 TXV 36,400 16.20 12.00 CX34-49 SL280UH110V60C 3933035
XC16-036-230 TXV 36,400 16.20 12.00 CX34-49 SL280UH110XV60C 4040517
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 17
Page 18
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-036-230 TXV 36,200 16.20 12.00 CX34-49 SLP98UH090V36C 4020686
XC16-036-230 TXV 36,600 16.50 12.00 CX34-49 SLP98UH090V48C 4020687
XC16-036-230 TXV 36,600 16.50 12.00 CX34-49 SLP98UH090V60C 4020688
XC16-036-230 TXV 36,600 16.50 12.20 CX34-49 SLP98UH110V60C 4020689
XC16-036-230 TXV 35,600 14.50 11.00 CX34-49 3068637
XC16-048-230 TXV 45,500 14.70 11.50 C33-44C G61MPV-60C-090 1003983
XC16-048-230 TXV 45,500 14.70 11.20 C33-44C G61MPV-60C-091 1046650
XC16-048-230 TXV 45,500 14.50 11.50 C33-44C G61MPV-60C-110 1003988
XC16-048-230 TXV 45,500 14.50 11.50 C33-44C G61MPV-60C-111 1046651
XC16-048-230 TXV 45,500 14.70 11.20 C33-48 G61MPV-60C-091 1046652
XC16-048-230 TXV 45,500 14.50 11.50 C33-48 G61MPV-60C-110 1003986
XC16-048-230 TXV 45,500 14.50 11.50 C33-48 G61MPV-60C-111 1046653
XC16-048-230 TXV 45,000 14.20 11.20 C33-48 O23V5-140/154 1038249
XC16-048-230 TXV 46,000 15.00 11.70 C33-48 SL280UH090V60C 3933036
XC16-048-230 TXV 46,000 15.00 11.70 C33-48 SL280UH090XV60C 4235458
XC16-048-230 TXV 45,500 14.70 11.70 C33-48 SL280UH110V60C 3933037
XC16-048-230 TXV 45,500 14.70 11.70 C33-48 SL280UH110XV60C 4040519
XC16-048-230 TXV 45,500 13.70 11.20 C33-48 1003999
XC16-048-230 TXV 47,500 15.20 12.00 C33-49 G61MPV-60C-090 1003774
XC16-048-230 TXV 47,500 15.00 11.70 C33-49 G61MPV-60C-091 1046654
XC16-048-230 TXV 47,500 15.00 12.00 C33-49 G61MPV-60C-110 1003775
XC16-048-230 TXV 47,000 15.00 11.70 C33-49 G61MPV-60C-111 1046655
XC16-048-230 TXV 46,500 14.70 11.70 C33-49 O23V5-140/154 1038250
XC16-048-230 TXV 47,500 15.70 12.20 C33-49 SL280UH090V60C 3933038
XC16-048-230 TXV 47,500 15.70 12.20 C33-49 SL280UH090XV60C 4235459
XC16-048-230 TXV 47,500 15.50 12.20 C33-49 SL280UH110V60C 3933039
XC16-048-230 TXV 47,500 15.50 12.20 C33-49 SL280UH110XV60C 4040520
XC16-048-230 TXV 47,000 14.20 11.70 C33-49 1003730
XC16-048-230 TXV 46,000 15.20 11.20 C33-50/60C CBWMV-60C-100 1088641
XC16-048-230 TXV 46,000 15.00 11.70 C33-50/60C G61MPV-60C-090 1003766
XC16-048-230 TXV 46,000 14.70 11.50 C33-50/60C G61MPV-60C-091 1046656
XC16-048-230 TXV 46,000 14.70 11.70 C33-50/60C G61MPV-60C-110 1003768
XC16-048-230 TXV 46,000 14.70 11.70 C33-50/60C G61MPV-60C-111 1046657
XC16-048-230 TXV 46,000 14.50 11.20 C33-50/60C O23V5-140/154 1038251
XC16-048-230 TXV 46,500 15.20 11.70 C33-50/60C SL280UH090V60C 3933040
XC16-048-230 TXV 46,500 15.20 11.70 C33-50/60C SL280UH090XV60C 4235460
XC16-048-230 TXV 46,000 15.00 11.70 C33-50/60C SL280UH110V60C 3933041
XC16-048-230 TXV 46,000 15.00 11.70 C33-50/60C SL280UH110XV60C 4040521
XC16-048-230 TXV 46,500 13.70 11.20 C33-50/60C 1003726
XC16-048-230 TXV 47,000 15.50 12.20 C33-60D G61MPV-60D-135 3133211
XC16-048-230 TXV 46,500 15.00 11.50 C33-60D O23V5-140/154 1003981
XC16-048-230 TXV 47,000 15.50 12.20 C33-60D SL280UH135V60D 3933042
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 18
Page 19
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-048-230 TXV 46,500 14.00 11.50 C33-60D 1004000
XC16-048-230 TXV 48,000 15.70 12.20 C33-62C G61MPV-60C-090 1003978
XC16-048-230 TXV 48,000 15.50 12.00 C33-62C G61MPV-60C-091 1046658
XC16-048-230 TXV 48,000 15.50 12.30 C33-62C G61MPV-60C-111 1046659
XC16-048-230 TXV 47,500 15.20 12.00 C33-62C O23V5-140/154 1003977
XC16-048-230 TXV 48,000 16.00 12.20 C33-62C SL280UH090V60C 3933043
XC16-048-230 TXV 48,000 16.00 12.20 C33-62C SL280UH090XV60C 4235461
XC16-048-230 TXV 48,000 15.70 12.50 C33-62C SL280UH110V60C 3933044
XC16-048-230 TXV 48,000 15.70 12.50 C33-62C SL280UH110XV60C 4040522
XC16-048-230 TXV 47,500 14.20 11.70 C33-62C 1003996
XC16-048-230 TXV 47,000 15.20 12.00 C33-62D O23V5-140/154 1003975
XC16-048-230 TXV 47,500 15.50 12.20 C33-62D SL280UH135V60D 3933045
XC16-048-230 TXV 47,000 14.20 11.50 C33-62D 1003997
XC16-048-230 TXV 48,000 14.70 11.70 CB26UH-042 1003995
XC16-048-230 TXV 48,000 14.70 12.00 CB26UH-048 1003952
XC16-048-230 TXV 48,000 14.70 11.70 CBX26UH-042 1003953
XC16-048-230 TXV 48,000 14.70 12.00 CBX26UH-048 1003954
XC16-048-230 TXV 47,000 15.70 12.20 CBX27UH-048 1145118
XC16-048-230 TXV 46,500 15.50 12.20 CBX27UH-060 1145119
XC16-048-230 TXV 47,000 14.70 12.00 CBX32M-048 1003958
XC16-048-230 TXV 47,500 14.50 11.70 CBX32M-060 1003957
XC16-048-230 TXV 47,000 15.70 12.20 CBX32MV-048 1003956
XC16-048-230 TXV 47,500 15.70 12.20 CBX32MV-060 1003955
XC16-048-230 TXV 47,500 15.70 12.50 CBX32MV-068 1003963
XC16-048-230 TXV 47,000 15.70 12.20 CBX40UHV-048 3291798
XC16-048-230 TXV 47,500 15.70 12.20 CBX40UHV-060 3291847
XC16-048-230 TXV 45,000 15.00 11.70 CH23-51 SL280UH090V60C 3933046
XC16-048-230 TXV 45,000 15.00 11.70 CH23-51 SL280UH090XV60C 4235462
XC16-048-230 TXV 45,000 14.70 11.70 CH23-51 SL280UH110V60C 3933047
XC16-048-230 TXV 45,000 14.70 11.70 CH23-51 SL280UH110XV60C 4040523
XC16-048-230 TXV 45,000 14.70 11.70 CH23-51 SL280UH135V60D 3933048
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH090V48C 4020710
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH090V60C 4020711
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH110V60C 4020712
XC16-048-230 TXV 45,000 14.70 11.50 CH23-51 SLP98UH135V60D 4020713
XC16-048-230 TXV 45,000 13.50 11.20 CH23-51 1003722
XC16-048-230 TXV 46,000 15.50 12.00 CH23-65 SL280UH090V60C 3933049
XC16-048-230 TXV 46,000 15.50 12.00 CH23-65 SL280UH090XV60C 4235463
XC16-048-230 TXV 45,500 15.20 12.00 CH23-65 SL280UH110V60C 3933050
XC16-048-230 TXV 45,500 15.20 12.00 CH23-65 SL280UH110XV60C 4040518
XC16-048-230 TXV 46,000 15.20 12.00 CH23-65 SL280UH135V60D 3933051
XC16-048-230 TXV 45,500 15.20 11.70 CH23-65 SLP98UH090V48C 4020714
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 19
Page 20
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-048-230 TXV 45,500 15.20 11.70 CH23-65 SLP98UH090V60C 4020715
XC16-048-230 TXV 46,000 15.20 12.00 CH23-65 SLP98UH110V60C 4020716
XC16-048-230 TXV 46,000 15.20 12.00 CH23-65 SLP98UH135V60D 4020717
XC16-048-230 TXV 45,500 13.70 11.20 CH23-65 1003998
XC16-048-230 TXV 48,000 15.70 12.50 CH23-68 SL280UH135V60D 3933052
XC16-048-230 TXV 48,000 15.70 12.50 CH23-68 SLP98UH135V60D 4020718
XC16-048-230 TXV 47,000 14.20 11.70 CH23-68 1003723
XC16-048-230 TXV 47,500 15.20 12.00 CH33-43 SL280UH090V48B 4016694
XC16-048-230 TXV 47,500 15.20 12.00 CH33-43 SL280UH090XV48B 4038715
XC16-048-230 TXV 45,500 14.70 11.50 CH33-44/48 SL280UH090V48B 4016695
XC16-048-230 TXV 45,500 14.70 11.50 CH33-44/48 SL280UH090XV48B 4038719
XC16-048-230 TXV 46,500 15.00 11.70 CH33-48 G61MPV-60C-090 1003972
XC16-048-230 TXV 46,500 15.00 11.70 CH33-48 G61MPV-60C-091 1046660
XC16-048-230 TXV 46,500 14.70 11.70 CH33-48 G61MPV-60C-111 1046661
XC16-048-230 TXV 46,500 15.20 11.70 CH33-48 SL280UH090V60C 3933053
XC16-048-230 TXV 46,500 15.20 11.70 CH33-48 SL280UH090XV60C 4235464
XC16-048-230 TXV 46,500 15.20 12.00 CH33-48 SL280UH110V60C 3933054
XC16-048-230 TXV 46,500 15.20 12.00 CH33-48 SL280UH110XV60C 4040524
XC16-048-230 TXV 46,000 15.00 11.70 CH33-48 SLP98UH090V48C 4020719
XC16-048-230 TXV 46,000 15.00 11.70 CH33-48 SLP98UH090V60C 4020720
XC16-048-230 TXV 46,500 15.00 11.70 CH33-48 SLP98UH110V60C 4020721
XC16-048-230 TXV 46,000 14.00 11.20 CH33-48C 1003724
XC16-048-230 TXV 47,500 15.20 12.00 CH33-49 G61MPV-60C-090 1132858
XC16-048-230 TXV 47,500 15.00 11.50 CH33-49 G61MPV-60C-091 1132859
XC16-048-230 TXV 47,500 15.00 12.00 CH33-49 G61MPV-60C-110 1132860
XC16-048-230 TXV 47,500 15.00 11.70 CH33-49 G61MPV-60C-111 1132861
XC16-048-230 TXV 47,500 15.50 12.00 CH33-49 SL280UH090V60C 3933055
XC16-048-230 TXV 47,500 15.50 12.00 CH33-49 SL280UH090XV60C 4235465
XC16-048-230 TXV 47,500 15.50 12.20 CH33-49 SL280UH110V60C 3933056
XC16-048-230 TXV 47,500 15.50 12.20 CH33-49 SL280UH110XV60C 4040525
XC16-048-230 TXV 47,500 15.20 12.00 CH33-49 SLP98UH090V48C 4020722
XC16-048-230 TXV 47,500 15.20 12.00 CH33-49 SLP98UH090V60C 4020723
XC16-048-230 TXV 47,500 15.20 12.00 CH33-49 SLP98UH110V60C 4020724
XC16-048-230 TXV 47,000 14.20 11.70 CH33-49 1132855
XC16-048-230 TXV 47,000 15.50 12.00 CH33-50/60C CBWMV-60C-100 1088639
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C G61MPV-60C-090 3094647
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C G61MPV-60C-091 1046662
XC16-048-230 TXV 47,000 15.00 11.70 CH33-50/60C G61MPV-60C-110 1003968
XC16-048-230 TXV 47,000 15.00 11.70 CH33-50/60C G61MPV-60C-111 1046663
XC16-048-230 TXV 47,000 15.50 12.00 CH33-50/60C SL280UH090V60C 3933057
XC16-048-230 TXV 47,000 15.50 12.00 CH33-50/60C SL280UH090XV60C 4235466
XC16-048-230 TXV 47,000 15.20 12.00 CH33-50/60C SL280UH110V60C 3933058
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 20
Page 21
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-048-230 TXV 47,000 15.20 12.00 CH33-50/60C SL280UH110XV60C 4040526
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C SLP98UH090V48C 4020725
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C SLP98UH090V60C 4020726
XC16-048-230 TXV 47,000 15.20 11.70 CH33-50/60C SLP98UH110V60C 4020727
XC16-048-230 TXV 47,000 14.20 11.70 CH33-50/60C 1050279
XC16-048-230 TXV 47,000 15.50 12.20 CH33-60D G61MPV-60D-135 1003993
XC16-048-230 TXV 47,000 15.50 12.20 CH33-60D SL280UH135V60D 3933059
XC16-048-230 TXV 47,000 15.20 12.00 CH33-60D SLP98UH135V60D 4020728
XC16-048-230 TXV 46,500 14.00 11.50 CH33-60D 1003992
XC16-048-230 TXV 47,500 15.50 12.20 CH33-62D G61MPV-60D-135 1003758
XC16-048-230 TXV 47,000 15.50 12.20 CH33-62D SL280UH135V60D 3933060
XC16-048-230 TXV 47,000 15.20 12.00 CH33-62D SLP98UH135V60D 4020729
XC16-048-230 TXV 47,000 14.00 11.50 CH33-62D 1003725
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 G61MPV-60C-091 1046664
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 G61MPV-60C-110 1003754
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 G61MPV-60C-111 1046665
XC16-048-230 TXV 44,500 14.50 11.50 CR33-48 SL280DF090V60C 3933061
XC16-048-230 TXV 44,500 14.70 11.50 CR33-48 SL280DF110V60C 3933062
XC16-048-230 TXV 45,000 14.70 11.70 CR33-48 SLP98DF090V48C 4020730
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 SLP98DF090V60C 4020731
XC16-048-230 TXV 44,500 14.20 11.20 CR33-48 SLP98DF110V60C 4020732
XC16-048-230 TXV 44,500 13.20 11.00 CR33-48 1003771
XC16-048-230 TXV 46,000 15.20 11.70 CR33-50/60 G61MPV-60C-090 1003762
XC16-048-230 TXV 46,000 14.70 11.50 CR33-50/60 G61MPV-60C-091 1046666
XC16-048-230 TXV 46,000 15.00 11.70 CR33-50/60 G61MPV-60C-111 1046667
XC16-048-230 TXV 46,500 15.20 12.00 CR33-50/60 SL280DF090V60C 3933063
XC16-048-230 TXV 46,500 15.20 12.20 CR33-50/60 SL280DF110V60C 3933064
XC16-048-230 TXV 46,000 15.00 11.50 CR33-50/60 SLP98DF090V48C 4020733
XC16-048-230 TXV 46,000 15.20 11.70 CR33-50/60 SLP98DF090V60C 4020734
XC16-048-230 TXV 46,500 15.20 11.70 CR33-50/60 SLP98DF110V60C 4020735
XC16-048-230 TXV 46,000 13.70 11.20 CR33-50/60 1003770
XC16-048-230 TXV 46,000 13.70 11.20 CR33-60 1005092
XC16-048-230 TXV 46,000 15.00 11.70 CX34-43 SL280UH090V48B 4016692
XC16-048-230 TXV 46,000 15.00 11.70 CX34-43 SL280UH090XV48B 4038706
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 CBWMV-60C-100 3060548
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 G61MPV-60C-090 1003961
XC16-048-230 TXV 45,500 14.70 11.20 CX34-44/48 G61MPV-60C-091 1046668
XC16-048-230 TXV 45,500 14.50 11.50 CX34-44/48 G61MPV-60C-111 1046669
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SL280UH090V48B 4016693
XC16-048-230 TXV 46,000 15.00 11.70 CX34-44/48 SL280UH090V60C 3933065
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SL280UH090XV48B 4038711
XC16-048-230 TXV 46,000 15.00 11.70 CX34-44/48 SL280UH090XV60C 4235467
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 21
Page 22
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 SL280UH110V60C 3933066
XC16-048-230 TXV 45,500 14.70 11.70 CX34-44/48 SL280UH110XV60C 4040527
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH090V48C 4020736
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH090V60C 4020737
XC16-048-230 TXV 45,500 14.70 11.50 CX34-44/48 SLP98UH110V60C 4020738
XC16-048-230 TXV 45,500 13.70 11.20 CX34-44/48 3024355
XC16-048-230 TXV 47,500 15.20 12.00 CX34-49 G61MPV-60C-090 3490811
XC16-048-230 TXV 47,500 15.00 11.70 CX34-49 G61MPV-60C-091 1046670
XC16-048-230 TXV 47,500 15.00 12.00 CX34-49 G61MPV-60C-110 1003910
XC16-048-230 TXV 47,000 15.00 11.70 CX34-49 G61MPV-60C-111 1046671
XC16-048-230 TXV 46,500 14.70 11.70 CX34-49 O23V5-140/154 1003909
XC16-048-230 TXV 47,500 15.70 12.20 CX34-49 SL280UH090V60C 3933067
XC16-048-230 TXV 47,500 15.70 12.20 CX34-49 SL280UH090XV60C 4235468
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SL280UH110V60C 3933068
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SL280UH110XV60C 4040528
XC16-048-230 TXV 47,000 15.50 12.00 CX34-49 SLP98UH090V48C 4020739
XC16-048-230 TXV 47,500 15.50 12.20 CX34-49 SLP98UH090V60C 4020740
XC16-048-230 TXV 47,500 15.50 12.00 CX34-49 SLP98UH110V60C 4020741
XC16-048-230 TXV 47,000 14.20 11.70 CX34-49 1050269
XC16-048-230 TXV 46,000 15.20 11.20 CX34-50/60C CBWMV-60C-100 1088640
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C G61MPV-60C-090 1003788
XC16-048-230 TXV 46,000 14.70 11.50 CX34-50/60C G61MPV-60C-091 1046672
XC16-048-230 TXV 46,000 14.70 11.70 CX34-50/60C G61MPV-60C-111 1046673
XC16-048-230 TXV 46,000 14.50 11.20 CX34-50/60C O23V5-140/154 1003785
XC16-048-230 TXV 46,500 15.20 11.70 CX34-50/60C SL280UH090V60C 3933069
XC16-048-230 TXV 46,500 15.20 11.70 CX34-50/60C SL280UH090XV60C 4235469
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SL280UH110V60C 3933070
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SL280UH110XV60C 4040529
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH090V48C 4020742
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH090V60C 4020743
XC16-048-230 TXV 46,000 15.00 11.70 CX34-50/60C SLP98UH110V60C 4020744
XC16-048-230 TXV 46,500 13.70 11.20 CX34-50/60C 1050270
XC16-048-230 TXV 47,000 15.50 12.20 CX34-60D G61MPV-60D-135 1003906
XC16-048-230 TXV 46,500 15.00 11.50 CX34-60D O23V5-140/154 1003905
XC16-048-230 TXV 47,000 15.50 12.20 CX34-60D SL280UH135V60D 3933071
XC16-048-230 TXV 47,000 15.20 12.00 CX34-60D SLP98UH135V60D 4020745
XC16-048-230 TXV 46,500 14.00 11.50 CX34-60D 1050271
XC16-048-230 TXV 48,000 15.50 12.00 CX34-62C G61MPV-60C-091 1046674
XC16-048-230 TXV 48,000 15.50 12.30 CX34-62C G61MPV-60C-110 1003904
XC16-048-230 TXV 48,000 15.50 12.30 CX34-62C G61MPV-60C-111 1046675
XC16-048-230 TXV 47,500 15.20 12.00 CX34-62C O23V5-140/154 1003903
XC16-048-230 TXV 48,000 16.00 12.20 CX34-62C SL280UH090V60C 3933072
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 22
Page 23
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-048-230 TXV 48,000 16.00 12.20 CX34-62C SL280UH090XV60C 4235470
XC16-048-230 TXV 48,000 15.70 12.50 CX34-62C SL280UH110V60C 3933073
XC16-048-230 TXV 48,000 15.70 12.50 CX34-62C SL280UH110XV60C 4040530
XC16-048-230 TXV 48,000 15.70 12.20 CX34-62C SLP98UH090V48C 4020746
XC16-048-230 TXV 48,000 15.70 12.20 CX34-62C SLP98UH090V60C 4020747
XC16-048-230 TXV 48,000 15.70 12.20 CX34-62C SLP98UH110V60C 4020748
XC16-048-230 TXV 47,500 14.20 11.70 CX34-62C 1050272
XC16-048-230 TXV 47,500 15.50 12.20 CX34-62D G61MPV-60D-135 1003902
XC16-048-230 TXV 47,000 15.20 12.00 CX34-62D O23V5-140/154 1003901
XC16-048-230 TXV 47,500 15.50 12.20 CX34-62D SL280UH135V60D 3933074
XC16-048-230 TXV 47,500 15.50 12.20 CX34-62D SLP98UH135V60D 4020749
XC16-048-230 TXV 47,000 14.20 11.50 CX34-62D 1050273
XC16-060-230 TXV 58,500 15.20 11.70 C33-49 G61MPV-60C-090 1003778
XC16-060-230 TXV 58,500 15.00 11.20 C33-49 G61MPV-60C-091 1046676
XC16-060-230 TXV 59,000 15.00 11.70 C33-49 G61MPV-60C-110 1003779
XC16-060-230 TXV 59,000 15.20 11.70 C33-49 G61MPV-60C-111 1046677
XC16-060-230 TXV 58,500 15.00 11.20 C33-49 O23V5-140/154 1003776
XC16-060-230 TXV 58,500 15.20 11.50 C33-49 SL280UH090V60C 3933075
XC16-060-230 TXV 58,500 15.20 11.50 C33-49 SL280UH090XV60C 4235471
XC16-060-230 TXV 58,500 15.00 11.20 C33-49 SL280UH110V60C 3933076
XC16-060-230 TXV 58,500 15.00 11.20 C33-49 SL280UH110XV60C 4040531
XC16-060-230 TXV 59,000 14.50 11.50 C33-49 1003784
XC16-060-230 TXV 57,500 14.70 11.20 C33-50/60C CBWMV-60C-120 3184074
XC16-060-230 TXV 57,500 14.70 11.20 C33-50/60C G61MPV-60C-090 1003810
XC16-060-230 TXV 57,500 14.70 11.20 C33-50/60C G61MPV-60C-091 1046678
XC16-060-230 TXV 57,500 14.70 11.20 C33-50/60C G61MPV-60C-110 1003808
XC16-060-230 TXV 57,500 14.70 11.20 C33-50/60C G61MPV-60C-111 1046679
XC16-060-230 TXV 57,500 14.50 11.20 C33-50/60C O23V5-140/154 1003780
XC16-060-230 TXV 57,500 15.00 11.20 C33-50/60C SL280UH090V60C 3933077
XC16-060-230 TXV 57,500 15.00 11.20 C33-50/60C SL280UH090XV60C 4235472
XC16-060-230 TXV 57,000 14.70 11.00 C33-50/60C SL280UH110V60C 3933078
XC16-060-230 TXV 57,000 14.70 11.00 C33-50/60C SL280UH110XV60C 4040532
XC16-060-230 TXV 57,500 14.20 11.20 C33-50/60C 1003795
XC16-060-230 TXV 58,500 15.50 11.40 C33-60D G61MPV-60D-135 3133210
XC16-060-230 TXV 58,500 15.00 11.50 C33-60D O23V5-140/154 1003930
XC16-060-230 TXV 58,500 15.50 11.50 C33-60D SL280UH135V60D 3933079
XC16-060-230 TXV 58,500 14.20 11.50 C33-60D 1003951
XC16-060-230 TXV 59,500 15.50 11.50 C33-62C G61MPV-60C-091 1046680
XC16-060-230 TXV 60,000 15.20 11.70 C33-62C G61MPV-60C-110 1004033
XC16-060-230 TXV 60,000 15.50 11.70 C33-62C G61MPV-60C-111 1046681
XC16-060-230 TXV 59,500 15.20 11.50 C33-62C O23V5-140/154 1003927
XC16-060-230 TXV 60,000 15.70 11.70 C33-62C SL280UH090V60C 3933080
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 23
Page 24
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-060-230 TXV 60,000 15.70 11.70 C33-62C SL280UH090XV60C 4235473
XC16-060-230 TXV 59,500 15.50 11.50 C33-62C SL280UH110V60C 3933081
XC16-060-230 TXV 59,500 15.50 11.50 C33-62C SL280UH110XV60C 4040533
XC16-060-230 TXV 60,000 14.70 11.70 C33-62C 1003950
XC16-060-230 TXV 59,500 15.70 12.00 C33-62D G61MPV-60D-135 3281425
XC16-060-230 TXV 59,000 15.20 11.50 C33-62D O23V5-140/154 1003932
XC16-060-230 TXV 59,000 15.50 11.70 C33-62D SL280UH135V60D 3933082
XC16-060-230 TXV 59,000 14.50 11.50 C33-62D 1003965
XC16-060-230 TXV 60,000 15.20 11.70 CB26UH-060 1003943
XC16-060-230 TXV 60,000 15.20 11.70 CBX26UH-060 1003948
XC16-060-230 TXV 58,500 15.50 11.70 CBX27UH-060 1145120
XC16-060-230 TXV 59,000 14.70 11.70 CBX32M-060 1003949
XC16-060-230 TXV 58,500 15.70 11.70 CBX32MV-048 1003947
XC16-060-230 TXV 59,000 15.70 11.70 CBX32MV-060 1003946
XC16-060-230 TXV 59,000 15.70 12.00 CBX32MV-068 1003945
XC16-060-230 TXV 58,500 15.70 11.70 CBX40UHV-048 3291799
XC16-060-230 TXV 59,000 15.70 11.70 CBX40UHV-060 3291848
XC16-060-230 TXV 55,500 13.50 10.70 CH23-51 3986401
XC16-060-230 TXV 55,500 13.50 10.70 CH23-51 3986402
XC16-060-230 TXV 56,500 15.00 11.20 CH23-65 SL280UH090V60C 3933083
XC16-060-230 TXV 56,500 15.00 11.20 CH23-65 SL280UH090XV60C 4235474
XC16-060-230 TXV 56,500 14.70 11.00 CH23-65 SLP98UH090V60C 4020690
XC16-060-230 TXV 56,000 15.00 11.20 CH23-65 SLP98UH110V60C 4020691
XC16-060-230 TXV 56,500 15.00 11.20 CH23-65 SLP98UH135V60D 4020692
XC16-060-230 TXV 56,500 14.00 11.20 CH23-65 1003966
XC16-060-230 TXV 59,500 15.50 11.70 CH23-68 SL280UH135V60D 3933084
XC16-060-230 TXV 59,000 15.70 11.70 CH23-68 SLP98UH135V60D 4020693
XC16-060-230 TXV 60,000 14.50 11.70 CH23-68 1003783
XC16-060-230 TXV 58,500 14.20 11.50 CH33-50/60C CBWMV-60C-120 1260281
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C G61MPV-60C-090 1003938
XC16-060-230 TXV 58,500 14.70 11.20 CH33-50/60C G61MPV-60C-091 1046682
XC16-060-230 TXV 58,500 15.00 11.50 CH33-50/60C G61MPV-60C-110 1003942
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C G61MPV-60C-111 1046683
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C SL280UH090V60C 3933085
XC16-060-230 TXV 58,500 15.20 11.50 CH33-50/60C SL280UH090XV60C 4235475
XC16-060-230 TXV 58,000 15.00 11.20 CH33-50/60C SL280UH110V60C 3933086
XC16-060-230 TXV 58,000 15.00 11.20 CH33-50/60C SL280UH110XV60C 4040534
XC16-060-230 TXV 58,000 15.00 11.00 CH33-50/60C SLP98UH090V60C 4020694
XC16-060-230 TXV 58,000 15.00 11.20 CH33-50/60C SLP98UH110V60C 4020695
XC16-060-230 TXV 58,500 14.50 11.50 CH33-50/60C 1003967
XC16-060-230 TXV 58,500 15.20 11.70 CH33-60D CBWMV-60C-100 1086362
XC16-060-230 TXV 58,500 15.50 11.70 CH33-60D G61MPV-60D-135 3069477
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 24
Page 25
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-060-230 TXV 58,000 15.20 11.50 CH33-60D SL280UH135V60D 3933087
XC16-060-230 TXV 58,000 15.50 11.50 CH33-60D SLP98UH135V60D 4020696
XC16-060-230 TXV 58,000 14.20 11.50 CH33-60D 1003964
XC16-060-230 TXV 58,500 15.20 11.70 CH33-62D G61MPV-60C-090 1132864
XC16-060-230 TXV 58,000 15.00 11.50 CH33-62D G61MPV-60C-090 4184803
XC16-060-230 TXV 58,500 15.20 11.50 CH33-62D G61MPV-60C-091 1132865
XC16-060-230 TXV 58,500 15.00 11.70 CH33-62D G61MPV-60C-110 1132866
XC16-060-230 TXV 58,000 15.20 11.50 CH33-62D G61MPV-60C-110 4184805
XC16-060-230 TXV 58,500 15.20 11.70 CH33-62D G61MPV-60C-111 1132867
XC16-060-230 TXV 58,500 15.50 11.70 CH33-62D G61MPV-60D-135 1003806
XC16-060-230 TXV 58,000 15.20 11.70 CH33-62D SL280UH090V60C 4184806
XC16-060-230 TXV 58,000 15.20 11.70 CH33-62D SL280UH090XV60C 4235818
XC16-060-230 TXV 58,000 15.20 11.70 CH33-62D SL280UH110V60C 4184807
XC16-060-230 TXV 58,500 15.20 11.50 CH33-62D SL280UH135V60D 3933088
XC16-060-230 TXV 58,500 15.50 11.70 CH33-62D SLP98UH135V60D 4020697
XC16-060-230 TXV 58,500 14.20 11.50 CH33-62D 1003782
XC16-060-230 TXV 57,500 15.20 11.50 CR33-60 G61MPV-60D-135 1003801
XC16-060-230 TXV 57,000 15.00 11.20 CR33-60 SLP98DF090V60C 4020706
XC16-060-230 TXV 57,000 14.70 11.20 CR33-60 SLP98DF110V60C 4020707
XC16-060-230 TXV 57,500 14.20 11.20 CR33-60 1003781
XC16-060-230 TXV 58,500 15.20 11.70 CX34-49 G61MPV-60C-090 1003919
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 G61MPV-60C-091 1046684
XC16-060-230 TXV 59,000 15.00 11.70 CX34-49 G61MPV-60C-110 3094650
XC16-060-230 TXV 59,000 15.20 11.70 CX34-49 G61MPV-60C-111 1046685
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 O23V5-140/154 1003916
XC16-060-230 TXV 58,500 15.20 11.50 CX34-49 SL280UH090V60C 3933089
XC16-060-230 TXV 58,500 15.20 11.50 CX34-49 SL280UH090XV60C 4235476
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 SL280UH110V60C 3933090
XC16-060-230 TXV 58,500 15.00 11.20 CX34-49 SL280UH110XV60C 4040535
XC16-060-230 TXV 58,500 15.20 11.20 CX34-49 SLP98UH090V60C 4020698
XC16-060-230 TXV 58,500 15.20 11.20 CX34-49 SLP98UH110V60C 4020699
XC16-060-230 TXV 59,000 14.50 11.50 CX34-49 1050274
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C CBWMV-60C-120 3184076
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-090 1003797
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-091 1046686
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-110 1003798
XC16-060-230 TXV 57,500 14.70 11.20 CX34-50/60C G61MPV-60C-111 1046687
XC16-060-230 TXV 57,500 14.50 11.20 CX34-50/60C O23V5-140/154 1003796
XC16-060-230 TXV 57,500 15.00 11.20 CX34-50/60C SL280UH090V60C 3933091
XC16-060-230 TXV 57,500 15.00 11.20 CX34-50/60C SL280UH090XV60C 4235477
XC16-060-230 TXV 57,000 14.70 11.00 CX34-50/60C SL280UH110V60C 3933092
XC16-060-230 TXV 57,000 14.70 11.00 CX34-50/60C SL280UH110XV60C 4040536
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 25
Page 26
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model No.
XC16-060-230 TXV 57,000 14.70 11.00 CX34-50/60C SLP98UH090V60C 4020700
XC16-060-230 TXV 57,000 14.70 11.00 CX34-50/60C SLP98UH110V60C 4020701
XC16-060-230 TXV 57,500 14.20 11.20 CX34-50/60C 1050275
XC16-060-230 TXV 58,500 15.50 11.40 CX34-60D G61MPV-60D-135 1003924
XC16-060-230 TXV 58,500 15.00 11.50 CX34-60D O23V5-140/154 1003917
XC16-060-230 TXV 58,500 15.50 11.50 CX34-60D SL280UH135V60D 3933093
XC16-060-230 TXV 58,500 15.50 11.70 CX34-60D SLP98UH135V60D 4020702
XC16-060-230 TXV 58,500 14.20 11.50 CX34-60D 1050276
XC16-060-230 TXV 59,500 15.50 11.70 CX34-62C G61MPV-60C-090 1003920
XC16-060-230 TXV 59,500 15.50 11.50 CX34-62C G61MPV-60C-091 1046688
XC16-060-230 TXV 60,000 15.20 11.70 CX34-62C G61MPV-60C-110 3069551
XC16-060-230 TXV 60,000 15.50 11.70 CX34-62C G61MPV-60C-111 1046689
XC16-060-230 TXV 59,500 15.20 11.50 CX34-62C O23V5-140/154 1003913
XC16-060-230 TXV 60,000 15.70 11.70 CX34-62C SL280UH090V60C 3933094
XC16-060-230 TXV 60,000 15.70 11.70 CX34-62C SL280UH090XV60C 4235478
XC16-060-230 TXV 59,500 15.50 11.50 CX34-62C SL280UH110V60C 3933095
XC16-060-230 TXV 59,500 15.50 11.50 CX34-62C SL280UH110XV60C 4040537
XC16-060-230 TXV 59,500 15.50 11.50 CX34-62C SLP98UH090V60C 4020703
XC16-060-230 TXV 59,500 15.50 11.50 CX34-62C SLP98UH110V60C 4020704
XC16-060-230 TXV 60,000 14.70 11.70 CX34-62C 1050277
XC16-060-230 TXV 59,500 15.70 12.00 CX34-62D G61MPV-60D-135 1003915
XC16-060-230 TXV 59,000 15.20 11.50 CX34-62D O23V5-140/154 1003914
XC16-060-230 TXV 59,000 15.50 11.70 CX34-62D SL280UH135V60D 3933096
XC16-060-230 TXV 59,000 15.70 11.70 CX34-62D SLP98UH135V60D 4020705
XC16-060-230 TXV 59,000 14.50 11.50 CX34-62D 1050278
NOTES:
TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.
Ratings are certied in accordance with USE certication program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed. Also see Expansion Valve Kit Usage Table.
Expansion Device
Capacity SEER EER
Coil or Air Handler
Furnace
AHRI Reference
XC16 - 2 to 5 Ton Air Conditioner / Page 26
Page 27
Page 28

REVISIONS

Sections Description of Change
AHRI System Ratings System ratings updated.
Visit us at www.lennox.com
For the latest technical information, www.lennoxdavenet.com
Contact us at 1-800-4-LENNOX
NOTE - Due to Lennox’ ongoing commitment to quality, Specications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualied installer and servicing agency. ©2010 Lennox Industries, Inc.