Lennox EL180DFE Series User Manual

E 2013 Lennox Industries Inc.
Dallas, Texas, USA
507141-01 01/2013
EL180DFE
SERIES
GAS FURNACE
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a licensed professional installer (or equivalent), a service agency, or the gas supplier.
FIRE OR EXPLOSION HAZARD.
Failure to follow safety warnings exact ly could result in serious injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other ap pliance.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING
Litho U.S.A.
WARNING
WHAT TO DO IF YOU SMELL GAS:
D Do not try to light any appliance. D Do not touch any electrical switch; do not
use any phone in your building.
D Leave the building immediately. D Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instructions.
D If you cannot reach your gas supplier, call
the fire department.
01/13
*2P0113*
507141-01
*P507141-01*
EL180DFE Parts Identification
TOP CAP
BLOWER
MOTOR
INTEGRATED
CONTROL
PRESSURE SWITCH
ASSEMBLY
BURNERS
COMBUSTION AIR
INDUCER
GAS VALVE AND
MANIFOLD
FIGURE 1
NOTE - This manual is the property of the homeowner and must be left with the equipment user.
Notice to Homeowner
This furnace is equipped with safety devices that protect you and your property. If one or more of these devices is activated, furnace operation will stop. If your home is left unattended for an extended period of time, equipment op
eration must be checked periodically. If this is not possible, the water supply to the house should be shut off and the pipes should be drained. This will prevent problems associ ated with a NO HEAT condition (frozen pipes, etc.)
Page 2
CAUTION
Before attempting to perform any service or mainte nance, turn the electrical power to unit OFF at the disconnect switch.
NOTICE
Any additions, changes, or conversions required in order for the appliance to satisfactorily meet the ap plication needs must be made by a licensed profes sional installer (or equivalent) using factory-speci fied and approved parts.
Safety Instructions
1 - Keep the furnace area clear and free of combustible
material, gasoline, and other flammable vapors and liquids. If it is installed in an insulated area, the furnace must be kept free of insulating material. Insulating ma terial may be combustible.
2 - DO NOT obstruct air flow to unit. Unit must receive an
unobstructed flow of combustion and ventilating air. DO NOT block or obstruct air openings on the furnace or air openings to the area in which the furnace is installed. Take care to maintain established clear ances surrounding the furnace.
3 - DO NOT store chlorine or fluorine products near unit
or introduce these products into the combustion air. These products can cause furnace corrosion.
4 - DO NOT draw return air from a room where this fur
nace, or any other gas appliance (ie., a water heat er), is installed. When return air is drawn from a room,
a negative pressure is created in the room. If a gas ap pliance is operating in a room with negative pressure, the flue products can be pulled back down the vent pipe and into the room. This reverse flow of the flue gas may result in incomplete combustion and the formation of carbon monoxide gas. This toxic gas might then be distributed throughout the house by the furnace duct system.
WARNING
The blower door must be securely in place when the blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into the living space resulting in personal injury or death.
Your furnace is a gas appliance. It is critical that the gas
supplied to the unit be completely burned to avoid the pro
duction of carbon monoxide gas. Complete combustion of the gas requires, but is not limited to, correct gas pressure and gas flow rate, adequate combustion, air, and proper venting.
WARNING
Asphyxiation Hazard
The exhaust vent for this furnace must be leak-free and must be securely connected to the furnace flue collar at all times.
For your safety and to fulfill the terms of the limited warranty, a licensed professional service technician (or equivalent) must annually inspect this furnace and its vent system.
Exposure to carbon monoxide gas can cause personal inju ry and even death to all occupants, including pets. Any item that is powered by or gives off heat from a combustion pro cess (including lawn mowers, automobiles, and fireplaces) has the potential to produce carbon monoxide gas. Because of this, Lennox recommends the use of a carbon monox
ide detector in your home, even if you do not own gas appliances. Reliable detectors are available at reasonable
retail prices. Contact your Lennox dealer for more details about this investment in your safety.
Your furnace is designed to meet standards set by nation al agencies, and to operate safely when properly installed and maintained. However, the unit's performance can be greatly impacted by the individual installation and the op erating environment. It is your responsibility to ensure that this appliance is maintained. Proper maintenance is criti cal for your safety and the satisfactory operation of the product. Lennox strongly recommends annual in spection and maintenance of this appliance. Contact your Lennox dealer for an inspection by a licensed profes sional service technician (or equivalent).
DANGER
Danger of explosion.
There are circumstances in which odorant used with LP/propane gas can lose its scent. In case of a leak, LP/propane gas will settle close to the floor and may be difficult to smell. An LP/propane leak detector should be installed in all LP applications.
Do not attempt to bleed the gas lines of air. Call your local gas provider.
Page 3