LOG PLACEMENT GUIDE
LOG PLACEMENT GUIDE FOR LENNOX DIRECT VENT EDV3530, EDV4035
AND EDV4540 SERIES VENTED GAS FIREPLACE HEATERS
GENERAL INFORMATION
This log placement guide has been prepared to present detailed log
placement illustrations and provide instruction to assist in the placement of logs at the initial (new appliance) setup and after the annual
cleaning and inspection cycles. The information provided here is to
be used in conjunction with the Homeowner's Care and Operation Instructions provided together with this document in the appliance literature packet. Please read the Homeowner's Care and Operation Instructions completely before completing the procedures detailed in
this placement guide.
INITIAL INSTALLATION CONSIDERATIONS
If the logs are being installed for the first time, the following paragraphs apply:
DO NOT attempt to install the logs until the appliance installation has
been completed, the gas line connected and tested for leaks and the
initial burner operation has been checked out.
750,158M
REV. N/C 05/2003
Figure 1
EDV3530, EDV4035 AND
EDV4540 SERIES
Step 1. Remove the appliance front door.
Step 2. Remove the boxed log set from the interior of the firebox.
Remove the logs from their packaging. Handle logs carefully to prevent breakage.
CERAMIC EMBER PANELS, LOGS AND GLOWING EMBER
PLACEMENT
Step 1. Install the Ceramic Ember Panels as shown in
should be placed in the order shown.
A. Place the left and right panel against the corners as shown.
B. Align the two front legs of the grate assembly on the dimples and
align the two rear legs between the cut out as shown.
C. Place the front panel into its proper position as shown. Adjust the
panels to minimize the gaps.
Note: This appliance is provided with enough Glowing Embers for several applications, do not feel compelled to use all that is in a new bag.
For best glowing effect, replace the ember material annually. Replacement Glowing Embers are available (Catalog Number 88L53).
Step 2. Position the individual logs as shown in
should be placed in the order shown. All logs that have notches to fit
over the grate tines should be positioned with these notches directly
against the grate.
Figure 3
Figures 4 and 5
. Panels
. Logs
Figure 2
Proper log placement is critical to encourage outstanding flame
appearance and prevent sooting. When positioned properly as
shown, logs will be positioned between flame peaks and will not
impinge any flames.
Step 3. Separate the Glowing Ember (Rockwool) into pieces about
the size of a quarter
Distribute these pieces over the front surface of the burner, as shown
in
Figure 2
tioned, the Glowing Embers will cover approximately 65% of the front
burner and with no appreciable gaps or openings. Ensure that the
main burner ports remain uncovered by the ember material.
Refer to
EDV4035 & EDV4540
. Do not use more than is necessary. When properly posi-
page 3 for EDV3530
Figure 1
. Keep the pieces fluffed up, not matted.
Series appliances and to
Series appliances.
page 4 for
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
1

CERAMIC EMBER PANEL PLACEMENT
Catalog Number for the entire Ceramic Ember Panel set: 55M4601 (For EDV3530), 55M4701 (For EDV4035)
And 55M4801 (For EDV4540).
Left Side
Panel
Left Side
Panel
Right Side
Panel
Grate Assembly
Right Side
Panel
Left Side
Panel
Grate Assembly Must Rest On
Dimples In Firebox Sub-Floor
Grate Assembly
Firebox Sub-Floor
Right Side
Panel
Front Panel
Figure 3
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

EDV3530 LOG PLACEMENT
Log Part
2
1
3
4
6
5
Number Description Number
1 Log, Rear 55M0601
2 Log, Diagonal/Left 55M0701
3 Log, Diagonal/Right 55M0801
4 Log, Front/Left 55M0901
5 Log, Top/Right 55M1001
6 Log, Front/Center 55M1101
Catalog Number for the entire log set: 55M0201
Locating Pins
2
1
Align Groove At The Bottom
Of Log (1) Over The Grate And
Push It Towards The Rear.
Locating Pin
Align The Hole On The Log (5) Over The Locating Pin
And Postition The Notch Over The Grate As Shown
4
Align The Groove In The Bottom Of Log (4)
Over The Grate And Slide It Toward The Front.
5
Align The Holes In One End Of Logs 2 & 3 Over The
Locating Pins And Align The Grooves On The Other
End Over The Grate And Push It Toward The Rear
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
6
Position The Grooves On Log (6)
Against The Grate As Shown
Figure 4
3

EDV4035 & EDV4540 LOG PLACEMENT
Log Part
Number Description Number
1 Log, Rear 55M1201
2 Log, Diagonal/Left 55M1301
3 Log, Diagonal/Right 55M1401
4 Log, Front/Left 55M1501
5 Log, Top/Right 55M1601
6 Log, Front/Center 55M1701
Catalog Number for the entire log set: 55M0301
1
2
1
3
4
6
5
Align The Hole On The Log (5) Over The Locating Pin
And Postition The Notch Over The Grate As Shown
4
5
Locating Pins
Align Groove At The Bottom
Of Log (1) Over The Grate And
Push It Towards The Rear.
Locating Pin
2
Align The Holes In One End Of Logs 2 & 3 Over The
Locating Pins And Align The Grooves On The Other
End Over The Grate And Push It Toward The Rear
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Lennox reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Align The Groove In The Bottom Of Log (4)
Over The Grate And Slide It Toward The Front.
3
6
Position The Grooves On Log (6)
Against The Grate As Shown
Figure 5
Printed in U.S.A. © 2003 by Lennox
P/N 750,158M REV. N/C 05/2003
4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
1110 West Taft Avenue • Orange, CA 92865