45" DIRECT-VENT GAS FIREPLACE HEATERS
P/N 504,135M REV. A 04/2001
MODELS
SERIES
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WH Report No. J20006701
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicinity of this or any other appliance.
tlovilliM
sledoM
2-MNC0454DE2-ENC0454DE
2-MPC0454DE2-EPC0454DE
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odiur de gaz:
cinortcelE
sledoM
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
1
Page 2
CONGRATULATIONS!
GENERAL INFORMATION
In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most
dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a
wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your LENNOX product.
Replacement Parts List ..................... page 17
The millivolt appliances are designed to operate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation. External
electrical power is required to operate the
optional electrically powered components if
installed. Electrical power must be wired during appliance installation.
The electronic appliances are designed to operate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.
These appliances comply with National Safety
Standards and are tested and listed by (Report
No. J20006711) to ANSI Z21.88b-1999 (in
Canada, CSA-2.33b-M99), and CAN/CGA-2.17M91 in both USA and Canada, as vented gas
fireplace heaters.
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.) Electrical wiring must comply with local codes. In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
INTRODUCTION
The Fireplace models covered in this manual
are Direct-Vent sealed combustion gas fireplace heaters designed for residential application. Direct-Vent appliances operate with the
combustion chamber completely isolated from
the inside atmosphere. All air for combustion
is brought in from the outside and exhaust
gases are vented through the same direct vent,
vent system.
2
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO THIS
MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Note: Installation and repair should be performed by a qualified service person. The
appliance should be inspected annually by a
qualified professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept
clean.
S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les instructions d'installation et d'utilisation qui
accompagnent l'appareil.
Provide adequate clearances around air openings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffic and away from furniture and draperies. Locate furniture and window coverings accordingly.
WARNING: THESE FIREPLACES ARE
VENTED HEATERS. DO NOT BURN WOOD
OR OTHER MATERIAL IN THESE APPLIANCES.
These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade the
performance of this system and may be dangerous.
On Millivolt models the input of the appliance
can be varied from 27,000 to 35,000 BTU/HR
when using natural gas or from 26,000 to
35,000 BTU/HR when using propane gas.
On Electronic models the input is fixed at 35,000
BTU/HR for both gas types.
.taN.porP
33#15#
ezisecifirO
noitavelE
0054-0
)0731-0(
ledoM
.oN
2-0454DE
Maximum manifold pressure is 3.5 in. w.c.
(0.87 kPa) for natural gas and 10 in. w.c.
(2.49 kPa) for LP/Propane gas.
)sretem(teeF
Page 3
Do not use these appliances if any part has
Piezo Ignitor
Gas Valve
Modesty Panel
Drop-down
Lower Door
ON/OFF
Switch
Hinge Pin
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the control system and any gas control which have
been under water.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifié pour inspecter l'appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l'leau.
Test gage connections are provided on the
front of the millivolt gas control valve (identified OUT for the manifold side and IN for inlet
pressure. A ¹⁄₈" NPT test gage connection is
provided on the electronic gas control valve
adjacent to the outlet to the main burner.
Minimum inlet gas pressure to these appliances
is 5.0 inches water column (1.24 kPa) for natural
gas and 11 inches water column (2.74 kPa) for
propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to these appliances is 10.5 inches water column (2.61 kPa) for
natural gas and 13.0 inches water column (3.23 kPa)
for propane.
The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure testing of the gas supply piping system at test
pressures equal to or less than ¹⁄₂ psig (3.5 kPa).
The appliance and its individual shut-off valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at pressures in excess of ¹⁄₂ psig (3.5 kPa).
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
Any safety guard or screen removed for servicing the appliance must be replaced prior to
operating the appliance.
WARNING: FAILURE TO COMPLY WITH
THE INSTALLATION AND OPERATING INSTRUCTIONS PROVIDED IN THIS DOCUMENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING APPLIANCE, VOIDING ITS WARRANTY. ANY
CHANGE TO THIS APPLIANCE AND/OR
ITS OPERATING CONTROLS IS DANGEROUS. IMPROPER INSTALLATION OR USE
OF THIS APPLIANCE CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON MONOXIDE POISONING.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to
the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air
immediately. Turn off the gas supply to the
appliance and have it serviced by a qualified
professional, as it may not be operating
correctly.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURES. USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS
ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled by the
following means: the factory provided modesty
panel-mounted ON-OFF control switch, a remotely located optional wall switch or optional
remote control.
The modesty panel mounted ON-OFF control
switch is located behind the hinged drop-down
panel below the appliance front glass enclosure
panel. See
Figure 1.
Gas Controls
The gas controls can be found behind the
hinged drop-down panel.
To open the hinged drop-down panel, actuate the
spring loaded, magnetic catches securing the
door, by gently depressing the outer top corners
of the door until the catches "pop" the door free,
allowing it to swing out and down to open.
On millivolt systems, the piezo ignitor, Hi/Lo
flame adjustment knob, and pilot and main gas
ON/OFF control knob are located on the modesty panel. On both millivolt and electronic
systems the gas valve is located behind the
modesty panel. See
Remove the bottom compartment door by
sliding the hinge pin, located at the door’s
left side, to the right until it disengages
from the left corner post hole. Pull the
door diagonally to the left, away from the
fireplace.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 1.
Once the control compartment door has been
removed, the modesty panel can be removed
as follows: lift the modesty panel by the tab on
the panel’s right end, pull the right end of the
panel away from cabinet and then pull the
panel diagonally out of the corner post slots on
the left side of the unit. Remove the modesty
panel carefully, so that none of the wires
become loose or disconnected. Now complete
access to the gas control valve and its related
controls is attainable.
Operation of millivolt and electronic gas
control systems are different. Before lighting and operating your appliance determine
if you have a millivolt or electronic appli-
Refer to Figure 1
ance.
control valve. Millivolt appliances will be
fitted with the gas control valve shown in
Figure 2 on page 4
Appliances with electronic systems will be
fitted with the electronic valve shown in
3 on page 4
control valve that your appliance uses.
Figure 1
Millivolt Appliances -
To light millivolt appliances refer to the detailed
lighting instructions found on
and page 12
ing instructions may also be found on the pull
out lighting instruction labels attached to the
gas control valve.
Millivolt appliances are fitted with an ON/OFF
Rocker Switch for appliance ON/OFF control.
See
lighted, the ON/OFF rocker switch will control
the appliance ON/OFF operation. To operate:
Toggle the switch between its ON and OFF
positions.
. Familiarize yourself with the gas
Control Compartment Access Millivolt Control Valve Shown
(French). Millivolt appliance light-
Figure 1
for its location. Once the pilot is
for access to the gas
.
Figure
page 11 (English)
3
Page 4
Variable Flame Height Adjustment
Manifold Pressure Port
TPTH TPTH
I
H
L
O
W
P
I
L
O
T
SIT Millivolt Gas Valve
Note: The piezo ignitor is located on the modesty panel - see Figure 1.
Figure 2
If your millivolt appliance is equipped with an
optional remote wall switch or remote control
kit and the pilot is lit, the appliance main burner
may be turned on and off with the wall switch or
remote control.
Electronic Appliances -
To light electronic appliances refer to the detailed lighting instructions found in both English and French on
pages 13 and 14
instructions respectively. Electronic appliance
lighting instructions may also be found on the
pull out lighting instruction labels attached to
the gas control valve.
Electronic appliances are fitted with an ON/OFF
Rocker Switch for appliance ON/OFF control.
See
Figure 1
for its location. Once the pilot is
lighted, the ON/OFF rocker switch will control
the appliance ON/OFF operation. To operate:
Toggle the switch between its ON and OFF
positions.
If your electronic appliance is equipped with an
optional remote wall switch or remote control
kit the appliance main burner may be turned on
and off with the wall switch or remote control.
variable gas control valve. Flame height for
these models may be adjusted through a range
between fixed low and high settings, alternately, while the appliance is in operation.
4
Inlet Pressure Port
IN
OUT
F
F
O
P
I
L
it
O
T
O
N
of these
Inlet
Pressure
Port
Electronic
Gas Control
Valve
Main Gas
Control Knob
Adjust the flame height as desired after lighting the appliance by rotating the variable
adjustment control knob located on the front
of the valve
(refer to Figure 2)
. (An extension
is provided to this knob so that the adjustment
may be made at the modesty panel.)
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is
due to the “burn-in” of internal paints and
lubricants used in the manufacturing process.
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and circulating air passageways of the appliance be kept clean.
4. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-lighting, refer to the lighting instructions in this
manual. Instructions are also found on a pullout panel located on the floor of the appliance.
5. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.
6. Remember, Millivolt appliances have a continuous burning pilot flame. Exercise caution
when using products with combustible vapors.
7. Clean the front glass enclosure only when
necessary. Wipe surface with clean, dampened, soft cloth. Follow with dry, soft towel as
desired. Take care not to scratch the glass
surface.
WARNING: DO NOT USE ABRASIVE
CLEANERS. NEVER CLEAN THE GLASS
WHEN IT IS HOT.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
CAUTION: DO NOT ATTEMPT TO TOUCH THE
FRONT ENCLOSURE GLASS WITH YOUR
HANDS WHILE THE FIREPLACE IS IN USE.
Maintenance
The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualified service technician. Proper maintenance and use will require
more frequent, less extensive inspections and
servicing by the homeowner.
Generally, annual inspections should be performed by a qualified service technician. More
frequent periodic inspections and cleanings
should be performed by the homeowner. Any
discrepancies discovered by the homeowner
should result in a call to a qualified service
technician to effect the repair or correction.
Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by
whom they should be performed. Always
verify proper operation of the appliance after
servicing.
IMPORTANT: TURN OFF GAS AND ANY ELECTRICAL POWER BEFORE SERVICING THE
APPLIANCE.
Control Compartment Access
The gas controls can be found behind the
hinged drop-down panel.
To open the door, actuate the spring loaded,
magnetic catches securing the door by gently
depressing the outer top corners of the door
until the catches "pop" the door free, allowing
it to swing out and down to open.
On millivolt systems, the piezo ignitor, Hi/Lo
flame adjustment knob, and pilot and main gas
ON/OFF control knob are located on the modesty panel. On both millivolt and electronic
systems the gas valve is located behind the
modesty panel. See
Remove the bottom compartment door by
sliding the hinge pin, located at the door’s
left side, to the right until it disengages
from the left corner post hole. Pull the
door diagonally to the left, away from the
fireplace.
Once the control compartment door has been
removed, the modesty panel can be removed
as follows: lift the modesty panel by the tab on
the panel’s right end, pull the right end of the
panel away from cabinet and then pull the
panel diagonally out of the corner post slots on
the left side of the unit. Remove the modesty
panel carefully, so that none of the wires
become loose or disconnected. Now complete
access to the gas control valve and its related
controls is attainable.
To ease door closure, depress the catches to
place them in their retracted position until they
stay there, then close the door.
Figure 1.
Page 5
Maintenance Schedule
Annually (Before the onset of the Burning Season)
Maintenance TaskAccomplishing PersonProcedure
Inspecting/Cleaning Burner, Logs
and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Appliance Checkout
Replacing Rockwool Ember Materials
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services Technician
Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the
control compartment, fireplace logs and burner
area.
Figure 7 on page 7
Refer to
and verify the flame
pattern and height displayed by the appliance
conforms to the picture. Flames must not
impinge on the logs.
Refer to
Figure 8 (SIT) or Figure 9 (Honeywell)
on page 7
. Remove any surface build-up on pilot
and burner assembly. Wipe the pilot nozzles,
ignitor/flame rod and hood. Ensure the pilot
flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of dislocation of the vent components.
Perform the appropriate appliance checkout
procedure detailed in this manual.
Remove old ember materials and vacuum the
screened rockwool placement area. Place new
rockwool as described in this document.
Periodically (After the Burning Season)
Maintenance TaskAccomplishing PersonProcedure
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Front Glass Enclosure Panel
Homeowner
Homeowner
Homeowner
Homeowner
Carefully remove logs, Rockwool and volcanic stone if used. Vacuum out interior of the
firebox. Clean firebox walls and log grate.
Replace logs, Rockwool and volcanic stone
as detailed in this manual.
Refer to Refer to
Figure 7 on page 7
and verify
the flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the logs.
Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage or obstruction. Look for any signs of
dislocation of the vent components.
Clean as necessary following the directions
provided in this manual. DO NOT TOUCH ORATTEMPT TO CLEAN GLASS WHILE HOT.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
Page 6
Front Glass Enclosure Panel, Removal
and Installation.
WARNING: NEVER OPERATE THE APPLIANCE WITHOUT THE FRONT GLASS ENCLOSURE PANEL IN PLACE AND SECURE.
DO NOT OPERATE APPLIANCE WITH
FRONT GLASS CRACKED, BROKEN OR
MISSING. REPLACEMENT MUST BE
DONE BY A LICENSED OR QUALIFIED
SERVICE TECHNICIAN.
These are direct-vent appliances. They are
designed to operate only when the front glass
enclosure panel is installed. Generally the front
glass enclosure panel should not be removed
except to gain access to the components within
the firebox, and the appliance may only be
operated without the front glass enclosure panel
in place for very brief periods of time during
appliance checkout and adjustment. Be sure
that the flame appearance will be diminished
while the front glass enclosure panel is removed.
WARNING: HANDLE THIS GLASS WITH
EXTREME CARE! TEMPERED GLASS IS
SUSCEPTIBLE TO DAMAGE – DO NOT
SCRATCH OR HANDLE ROUGHLY WHILE
REINSTALLING THE GLASS DOOR
FRAME.
WARNING: NO NOT ATTEMPT TO SUBSTITUTE THE MATERIALS USED ON THIS
DOOR, OR REPLACE CRACKED OR BROKEN GLASS WITH ANY MATERIALS
OTHER THAN THOSE PROVIDED BY THE
APPLIANCE MANUFACTURER.
THE GLASS DOOR OF THIS APPLIANCE MUST
ONLY BE REPLACED AS A COMPLETE UNIT AS
PROVIDED BY THE MANUFACTURER. DO
NOT ATTEMPT TO REPLACE BROKEN,
CRACKED OR CHIPPED GLASS SEPARATELY.
Refer to
enclosure panel as follows:
1. Open the hinged drop-down control com-
partment panel.
2. Remove the bottom compartment door
by sliding the hinge pin, located at the
door’s left side, to the right until it disengages from the left corner post hole. Pull
the door diagonally to the left, away from
the fireplace.
3. Remove the modesty panel as follows: lift the
modesty panel by the tab on the panel’s right end,
pull the right end of the panel away from cabinet
and then pull the panel diagonally out of the
corner post slots on the left side of the unit.
Remove the modesty panel carefully, so that
none of the wires become loose or disconnected.
6
Figure 4
and remove the front glass
Lower Compartment Door and Hinge
Top Flange
Glass Door Frame
Glass Door
Modesty Panel
Bottom Vee-flange
Glass Door Frame
Figure 4
4. Locate the two (2) latches at the top of the
control compartment and disengage them from
the floor frame bottom Vee-flange, pulling
down on their handles to open them.
5. Swing the bottom of the door out and raise
it slightly to lift the top flange of the door frame
away from the appliance.
To install the front glass enclosure panel,
proceed as follows:
1. Retrieve the glass door frame. Visually
inspect the gasket on the backside of the panel.
The gasket surface must be clean, free of
irregularities and seated firmly.
2. Position the door frame in front of the
firebox opening and engage the top flange over
the lip at the top of the firebox opening.
3. Swing the door down and back. Ensure the
gasket seats evenly as the door draws shut.
Engage the Vee-flange at the bottom of the
door with the latches and close the latches to
secure the door.
4. Reinstall the modesty panel by inserting the
left end of it into the left corner post slots,
swing the right end toward the right corner
post and hook it in the right corner post slot.
5. Reinstall the bottom compartment door by
inserting the right side locating pin into the right
cabinet corner post and then the left side springloaded pin into the left cabinet corner post.
Glass Door Latch
Firebox Floor
Burner Adjustments
The following paragraphs address burner adjustment concerns and procedures.
Flame Appearance and Sooting
Proper flame appearance is a matter of taste.
Generally most people prefer the warm glow of
a yellow to orange flame. Appliances operated
with air shutter openings that are too large will
exhibit flames that are blue and transparent.
These weak, blue and transparent flames are
termed anemic. If the air shutter opening is too
small sooting may develop.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Sooting is indicated by black puffs developing
at the tips of very long orange flames. Sooting
results in black deposits forming on the logs,
appliance inside surfaces and on exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in
the flames and a lack of combustion air entering
the air shutter opening. To achieve a warm
yellow to orange flame with an orange body that
does not soot, the shutter opening must be
adjusted between these two extremes. No smoke
or soot should be present. Reposition the logs if
the flames impinge on any of them.
If the logs are properly positioned and sooting
conditions exist, the air shutter opening on the
main burner tube should be adjusted. Normally,
the more offsets in the vent system, the greater
the need for the air shutter to be opened further.
WARNING: AIR SHUTTER ADJUSTMENT
SHOULD ONLY BE PERFORMED BY A
QUALIFIED PROFESSIONAL SERVICE
TECHNICIAN.
ENSURE THAT THE FRONT GLASS PANEL IS IN
PLACE AND SEALED DURING ADJUSTMENT.
Adjustment
CAUTION: THE ADJUSTMENT ROD AND
NEARBY APPLIANCE SURFACES ARE HOT.
EXERCISE CAUTION TO AVOID INJURY WHILE
ADJUSTING FLAME APPEARANCE.
To adjust the flame, move the adjustment rod
(located in the lower control area) back or
forward to increase or reduce the air shutter
opening, respectively. Position the air shutter
to the factory setting as shown in
page 7
. Allow the burner to operate for at least
15 minutes. Observe the flame continuously. If
it appears weak or sooty as previously described, adjust the air shutter by pushing or
pulling on the adjustment rod until the flame
appearance is as desired.
The adjustment rod and associated adjustable
air shutter is patented technology. Flame adjustments can be made quickly and accurately
to taste without the need of disassembling the
appliance and waiting for 30 minutes after each
adjustment.
Propane models may exhibit a flame pattern
that may candle or appear stringy. If this is
problematic or persists as the appliance is
continually operated, adjust the air shutter closed
as described in the previous paragraphs. Operate the appliance for a period of time as the
effect diminishes, ensuring that the appliance
does not develop sooty flames.
When satisfied that the appliance operates properly, proceed to finish the installation. Leave the
control knob in “ON” position and turn the
remote switch “OFF.” Close the lower control
compartment door.
Figure 5 on
Page 7
Burner
Venturi
Tube
Air
Shutter
Door
Air Shutter
Opening
Natural Gas Slot
(A dimple or hole
identifies the natural
Propane Gas Slot
Air Shutter
Adjusting
Rod
Decrease Shutter Opening In This Direction
Increase Shutter Opening In This Direction
Orifice
gas slot)
Air Shutter
Adjusting Arm
RENRUBNIAM
GNITTESGNINEPORETTUHSYROTCAF
sledoM
2-0454DE
saGlarutaN
)mm(sehcni
₈⁄¹)3(₈⁄⁵)8.51(
saGenaporP
)mm(sehcni
Figure 5
Log Placement
WARNING: LOGS GET VERY HOT AND
WILL REMAIN HOT UP TO ONE HOUR
AFTER GAS SUPPLY IS TURNED OFF.
HANDLE ONLY WHEN LOGS ARE COOL.
TURN OFF ALL ELECTRICITY TO THE
APPLIANCE BEFORE YOU INSTALL
GRATE AND LOGS.
WARNING: THIS APPLIANCE IS NOT
MEANT TO BURN WOOD. ANY ATTEMPT
TO DO SO COULD CAUSE IRREPARABLE
DAMAGE TO YOUR APPLIANCE AND
PROVE HAZARDOUS TO YOUR SAFETY.
WARNING: THE SIZE AND POSITION OF
THE LOG SET WAS ENGINEERED TO GIVE
YOUR APPLIANCE A SAFE, RELIABLE
AND ATTRACTIVE FLAME PATTERN. ANY
ATTEMPT TO USE A DIFFERENT LOG SET
IN THE FIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUSTION, SOOTING, AND
POOR FLAME QUALITY.
Figure 6
Carefully position the ceramic fiber logs and
twigs over the burner as shown in
Figure 6
Refer to the detailed log placement instructions provided in the LOG PLACEMENT GUIDE
accompanying this document.
Proper twig placement is critical to prevent
sooting. Twigs should be placed in the gaps
between the flame peaks and should be positioned so that at no time they impinge the
flames.
Rockwool (Glowing Embers) Placement
Remove the replacement rockwool from the
packaging and tear into nickel size pieces
(
Figure 7
). Spread on and along the length of
the front burner section. Do not use more than
is necessary. Too many nickle-sized pieces on
the front burner section will cause poor combustion.
When properly positioned, the rockwool will
unevenly cover approximately 65% of the front
burner with no appreciable gaps or openings.
Do not place ember materials over large ports
- refer to the LOG PLACEMENT GUIDE.
Figure 7
Vermiculite Placement
Mound up a portion of the vermiculite (with a
mixture of black and gray ceramic fiber chunks)
in front of burner and grate. Taper off mound to
the front and at the sides. Spread the remaining
vermiculite evenly over the bottom surface of
the appliance firebox bottom plate as desired
to achieve an esthetically pleasing appearance.
For best results, spread in a non-uniform manner while ensuring complete coverage of the
tan sheetmetal surface.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Millivolt Appliance Checkout
.
The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.
The top ³⁄₈" (10 mm) at the pilot generator (thermopile) and the top ¹⁄₈" min (tip) of the quick drop
out thermocouple should be engulfed in the pilot
flame. The flame should project 1" (25 mm)
beyond the hood at all three ports. See
To light the burner, refer to the lighting instructions on
pages 11 and 12.
Thermocouple
Figure 8
MILLIVOLT
SIT
Pilot
Nozzels
Hood
Thermopile
Electronic Appliance Checkout
To light the burner, refer to the lighting instructions on
page 13 and 14
. Ensure the ignitor
lights the pilot. The pilot flame should engulf the
flame sensor as shown in
ELECTRONIC
Proper Flame
Adjustment
Pilot
Nozzle
Figure 9
3/8 To 1/2 Inch
(9 mm to 13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Figure 9
With proper care and maintenance, your appliance will provide many years of enjoyment. If you
should experience any problem, first refer to the
trouble shooting guide in this manual. If problem
persists, contact your Lennox distributor.
Figure 8.
Ignitor Rod
³⁄₈" Min
(9 mm)
.
Igniter
7
Page 8
WIRING DIAGRAMS
Wiring diagrams are provided here for reference purposes only. This information is also
provided on schematics attached directly to
the appliance on a pullout panel located within
the control compartment.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS APPLIANCE OPERATION.
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced, it
must be replaced with Type AWM 200°C – 18 GA. wire.
TH
TP
TP
TH
Thermopile
Field Wired
Factory Wired
APPLIANCE-MOUNTED ON/OFF SWITCH
*OPTIONAL WALL-MOUNTED ON/OFF
SWITCH OR OPTIONAL THERMOSTAT
*Turn the appliance-mounted ON/OFF burner control switch to
the OFF position if an optional control switch is installed.
Schematic Representation Only
1. If any of the original wire as supplied must be replaced,
1. it must be replaced withType AWM 200°C – 18 GA.
2. 120V, 60Hz – Less than 3 amps.
**ON/OFF Switch (Integral
BK
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-100 and FBK-200 Kits
wire.
**Leave the ON/OFF switch, which is integral
with Gas Valve)
Gas Valve
BK
R
BL
OPT
BLOWER
Hot side of Outlet
*Blower speed control switch is provided in FBK200 blower kit.
***Turn the appliance-mounted ON/OFF burner control switch
to the OFF position if an optional control switch is installed.
with the gas valve, in the ON position.
*OPTIONAL
ACCESSORY
PILOT
ASSEMBLY
IGNITER
J-box Green
Ground
Screw
G
Break Off
Tab
W
BL
R
APPLIANCE-MOUNTED ON/OFF SWITCH
Factory WiredField Wired
Schematic Representation Only
SWITCH
Black
pigtail
Red
pigtail
Junction Box
B
***OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
BK
W
G
Outlet Box
Green Ground
White Wire
to Opposite
Transf.
120 V.
24 V
Screw
Side
R
R
VAC.
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-250 Kits
1. If any of the original wire as supplied must be replaced,
1. it must be replaced withType AWM 200°C – 18 GA.
wire.
2. 120V, 60Hz – Less than 3 amps.
*ON/OFF Switch (Integral
with Gas Valve)
Gas Valve
120
BK
R
BL
OPT
BLOWER
Hot side of Outlet
BK
**Turn the appliance-mounted ON/OFF burner control switch to
the OFF position if an optional control switch is installed.
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
PILOT
ASSEMBLY
IGNITER
Optional FBK-250
Module
W
B
BL
R
APPLIANCE-MOUNTED ON/OFF SWITCH
Factory WiredField Wired
Schematic Representation Only
Outlet Box Green
Ground Screw
**OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
G
G
BK
W
White Wire
To Opposite
Side
J-box Green
Ground Screw
Junction Box
Transf.
120 V.
24 V
R
R
120
VAC.
WARRANTY
Your gas appliance is covered by a limited
twenty year warranty. You will find a copy of
the warranty accompanying this manual. Please
read the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu-
REPLACEMENT PARTS
A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.
Normally, all parts should be ordered through
your Superior distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
ments for future reference.
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your fireplace. Please
contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox
dealer, please call 800-731-8101
Your Fireplace's Model Number _______________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed __________________________
The Type of Gas Your Fireplace Uses ___________________________________
Your Dealer's Name_________________________________________________
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or application of this system, please contact your distributor, or Superior directly:
LENNOX HEARTH PRODUCTS
4325 Artesia Avenue
Fullerton, CA 92833
(714) 521-7302
8
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 9
ACCESSORY COMPONENTS
INDICATOR
SIGNAL
LIGHT
ON/OFF
BUTTONS
Remote Control System (Standard) 26N04RC
ON
OFF
Standard Remote Control System
The Model RC (Standard) Remote Control
System, features a simplistic on/off control
function for the fireplace. This model includes
a hand-held transmitter, a remote receiver
with wall-mount coverplate and all hardware
required to install the unit. The remote receiver can be wall or hearth mounted.
The transmitter has ON and OFF functions that
are activated by pressing either button on the face
of the transmitter. When a button on the transmitter is pressed, a signal light illuminates briefly
to verify that a signal has been sent.
The Model RC is designed to operate with all
millivolt ignition systems, as well as electronic
ignition systems. It may be installed with use for
either natural or propane gas appliances. The RC
offers ease of installation and allows you to
execute on-off commands to the fireplace effortlessly with one simple motion.
The Model RC comes complete with detailed
operating instructions.
MODE
SET
UP
DOWNTIMER/
TIME
COVER
OPEN
Remote Control System (Deluxe) 98K99RC-STAT
LCD SCREEN
Deluxe Remote Control System
The Model RC-STAT (Deluxe) Remote Control
System has all of the features of the standard
system along with an added easy to read LCD
screen which presents access to many enhancements, including; battery power level indicator, timer, mode of operation, thermostatic
display including room temperature in either
metric of English units, flame indicator and
clock. Fully programmable, the Model RCSTAT allows for virtual command over nearly all
operational and temperature variables, using
the hand held remote control transmitter.
The Model RC-STAT (Deluxe) remote control
system is installed in the same manner as the
standard system, may be operated with electronic and millivolt systems with either natural
or propane gas. The RC-STAT comes complete
with detailed operating instructions.
Screen Panel Kit96K33HG45
Screen Panel Kit
An optional screen panel can be installed on the
4540 Series door. This screen panel is easy to
install. This kit can be retrofitted to previously
installed appliances. The screen panel kit can not
be used in conjunction with either of the arch
door kits or door frame kits.
Arch Door Kits
Brass Finish81L36ADK45CPB
Brushed Stainless Finish98L70ADK45CBS
Arch Door Kits
Two arch door kits are available for the 4540
Series. Both kits are easy to install and do not
require hardware to attach them to the standard
door frame. These kits can be retrofitted to
previously installed 4540 Series appliances.
The decorative arch kits can not be used in
conjunction with the screen panel kit.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
A clean faced panel kit is available to convert the
standard louvered appliances to radiant models
more suited for finishing around the firebox
opening with non-combustible materials such
as tile.
Attractive hoods are available in two styles to
be used on the 4540 Series appliances. These
hoods are designed to be fitted to the face of
the appliance. In addition to providing an aesthetically pleasing appearance to your appliance installation, the hood reduces heat effects to decorative mantles and finish materials located above the fireplace opening. The
hood kit replaces the standard hood that comes
with these appliances and snaps into place.
These kits can be retrofitted to previously
installed appliances.
(FBK-200 Models Only)
Forced Air Blower Kits
-Single Speed80L84FBK-100
-Variable Speed with wall-mountable switch
80L85FBK-200
-Variable Speed with unit-mountable switch
80L86FBK-250
Forced Air Kit
The FBK-100 blower provides for a constant
velocity forced air circulation feature for your
appliance. The FBK-200 assembly with variable
speed wall switch provides a forced air circulation feature for your appliance. The FBK-250
comes complete with a unit mountable switch
operating system.
Door Frame Kits
Brushed Stainless Finish90L71DTK45BS
Brass Finish88L45DTK45PB
Door Frame Kits
A decorative door frame kit is available for use
with these appliances. The DTK is designed to
attach directly to the front face of the appliance
at its extreme edges. The DTK provides a picture frame finish for the appliance. The door
frame kit can be retrofitted onto previously
installed appliances.
Touch-Up Paint (Charcoal) Kit90L74 TPK-C
Touch-Up Paint Kit
Repair of minor scratches and discoloration of
the appliance black painted surfaces may be
accomplished with the touch-up paint kit.
Bag of Glowing Embers88L53FGE
Bag of Glowing Embers
Replacement ember materials are available for
use with these appliances. Order a bag of Glowing Embers, Model FGE to replace ember materials as part of the periodic maintenance of the
appliance.
Decorative louvers are available for use with all
4540 Series direct vent louvered-face appliances. These louvers are designed to replace
the standard charcoal louvers that are provided with the appliance. The brass louver kit
includes eight (6) brass louvers. They provide
a touch of elegance to any 4540 Series appliance. This kit can be retrofitted to previously
installed appliances.
10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 11
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lighted with a piezo
ignitor. When lighting the pilot, follow these instructions
exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Access the lower control compartment.
3. Turn remote wall switch to “OFF.”
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
• If your gas supplier cannot be reached, call the fire depart-
ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
6. Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above on this page. If you
do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to “PILOT.”
8. Push in control knob all the way and hold in. Immediately light the
pilot by triggering the spark ignitor (pushing the button) until pilot
lights. Continue to hold the control knob in for about 1 ¹⁄₂ minutes
after the pilot is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.
IN
TPTHTPTH
I
H
W
L
O
P
I
L
O
T
OUT
F
F
O
P
I
L
O
it
T
O
N
Note: Knob cannot be turned from “PILOT” to “OFF”
unless the knob is pushed in slightly. Do not force.
TO TURN OFF GAS TO APPLIANCE
1. Turn remote wall switch “OFF.” The pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to “OFF.”
3. Access the lower control compartment.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
• If knob does not pop up when released, stop
and immediately call your service
technician or gas supplier.
• If pilot will not stay lit after several
tries, turn the control knob to “OFF”
and call your service technician or gas
supplier.
9. Turn gas control knob counterclockwise
to “ON.”
10. Close lower control compartment.
4. Depress gas control knob slightly and turn clockwise
to “OFF.” Do not force.
5. Close lower control compartment.
11
Page 12
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE
EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre
exactement ces instructions.
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez aucune
odeur de gaz autour de l’apareil ainsi que près du sol; certains gaz, étant
plus lourds que l’air, descendent au niveau du sol.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR
DE GAZ:
•Éteignez toute flamme visible.
• Ouvrez les fenêtres.
• N’allumez aucun appareil.
• Ne touchez à aucun commutateur électrique.
• Ne vous servez d’aucun téléphone dans votre édifice.
INSTRUCTIONS D'ALLUMAGE
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.
2. Ouvrez le compartiment de contrôle du bas.
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
4. Assurez-vous que la soupape d’arrêt de la canalisation principale est
ouverte.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position
d’arrêt “OFF”.
IN
TPTHTPTH
I
H
W
L
O
P
I
L
O
T
Remarque: Il est impossible de tourner le bouton de “PILOT” à“OFF”à
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez
une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des consignes
de sécurité au verso de cette plaque. Si vous ne remarquez aucune
odeur de gaz, passez à l’étape suivante.
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en
sens inverse des aiguilles d’une montre jusqu’à la position de
veilleuse“PILOT”.
OUT
F
F
O
P
I
L
O
it
T
O
N
• Appelez immédiatement votre compagnie de gaz en utilisant le téléphone
du voisin.
• S’il vous est impossible de contacter votre compagnie de gaz, appelez
le service des incendies.
C. N’utilisez que votre main pour manipuler le bouton de réglage du gaz.
N’utilisez jamais d’outils. Si le bouton refuse de tourner ou de bouger,
n’essayez pas de le réparer. Communiquez immédiatement avec un
technicien de service qualifié. Toute tentative pour le forcer ou le
réparer, risquerait de provoquer un incendie ou une explosion.
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été
immergé dans l’eau. Appelez immédiatement un technicien compétent
pour faire inspecter l’appareil et remplacer toute pièce du système de
réglage ou commande du gaz qui a été sous l’eau.
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz àétincelle (en poussant le bouton) jusqu’à ce que la veilleuse
s’enflamme. Continuez de tenir le bouton de réglage enfoncé
pendant environ 90 secondes après l’allumage de la veilleuse.
Relâchez le bouton et il sortira subitement. La veilleuse devrait
rester allumée. Si elle s’éteint, répétez les étapes 5 à 8
inclusivement.
• Si le bouton ne sort pas automatiquement après avoir été relâché,
arrêtez immédiatement et téléphonez
à votre technicien de service ou à
votre fournisseur de gaz.
• Si la veilleuse refuse de rester
allumée après plusieurs tentatives,
tournez le bouton de réglage jusqu’à
sa position d’arrêt “OFF” et
téléphonez à votre technicien de
service ou à votre fournisseur de gaz.
9. Tournez le bouton de réglage du gaz en sens inverse des aiguilles
d’une montre jusqu’à sa position de marche “ON”.
10. Fermez le compartiment de contrôle du bas.
11. Au besoin, rebrancher l’appareil au courant électrique et remettre
l’interrupteur du brûleur principal à la position “ON” ou régler le
thermostat à la température désirée.
12. Si l’appareil ne fonctionne pas, suivre les instructions intitulées
“Pour fermer le gaz qui alimente l’appareil” et appeler un
technicien ou le fournisseur de gaz.
12
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse
restera allumée jusqu’au retour du service normal.
2. Pour une fermeture complète, tournez l’interrupteur mural à la
position d’arrêt “OFF”.
3. Ouvrez le compartiment de contrôle du bas.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre jusqu’à la position
d’arrêt “OFF”. Ne forcez pas le bouton.
5. Fermez le compartiment de contrôle du bas.
Page 13
LIGHTING INSTRUCTIONS — ELECTRONIC
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. When lighting the appliance, follow these instructions
exactly.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
• Do not use any phone in your building.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to “OFF.”
3. Open lower control compartment door.
4. Verify main line shut-off valve is open.
• Immediately call your gas supplier from a neighbor’s
phone.
• If your gas supplier cannot be reached, call the fire
department.
C. Use only your hand to turn the gas control lever. Never
use tools. If the lever will not turn by hand, do not try to
repair it, call a qualified service technician. Force or
attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
5. Turn the ON/OFF switch to “OFF”. Do not force.
6. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the
next step.
7. Turn the ON/OFF switch to “ON”. Do not force.
ON/OFF Switch
CONTROL
OFF
ON
IG
N
IT
E
Front View
I
I
S
P
TO TURN OFF GAS TO APPLIANCE
1. For complete shut-down, turn remote wall switch to
“OFF.”
2. Open lower control compartment door.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
8. Turn “ON” all electrical power to appliance (remote wall
switch).
9. Close lower control compartment door.
TO SHUT OFF
1. Turn off all electrical power to the appliance (remote wall
switch).
3. Turn the ON/OFF switch to “OFF”. Do not force.
4. Close the main line shut-off valve.
5. Close lower control compartment door.
13
Page 14
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU
UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Lorsque vous allumez l’appareil, suivez exactement ces in-
structions.
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez
aucune odeur de gaz autour de l’apareil ainsi que près du sol;
certains gaz, étant plus lourds que l’air, descendent au niveau
du sol.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE
ODEUR DE GAZ
•Éteignez toute flamme visible.
• Ouvrez les fenêtres.
• N’allumez aucun appareil.
• Ne touchez à aucun commutateur électrique.
• Ne vous servez d’aucun téléphone dans votre édifice.
INSTRUCTIONS D’ALLUMAGE
1. ARRÊTEZ ! Lisez les consignes de sécurité au verso de cette
plaque.
2. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
3. Ouvrez la porte du compartiment de contrôle du bas.
4. Assurez-vous que la soupape d’arrêt de la canalisation principale
est ouverte.
• Appelez immédiatement votre compagnie de gaz en utilisant
le téléphone du voisin.
• S’il vous est impossible de contacter votre compagnie de
gaz, appelez le service des incendies.
C. N’utilisez que votre main pour manipuler linterrupteur “ON/
OFF” de la valve à gaz. N’utilisez jamais d’outils. Si
l’interrupteur ne bouge pas manuellement, n’essayez pas de le
réparer. Communiquez immèdiatement avec un technicien de
service qualifié. Toute tentative pour forcer l’interrupteur ou le
réparer, risquerait de provoquer un incendie ou une explosion.
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été
immergé dans l’eau. Appelez immédiatement un technicien
compétent pour faire inspecter l’appareil et remplacer toute
pièce du système de réglage ou commande du gaz qui a été
sous l’eau.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous
décelez une odeur de gaz ARRÊTEZ ! Retournez au point “B” des
consignes de sécurité au verso de cette plaque. Si vous ne
remarquez aucune odeur de gaz, passez à l’étape suivante.
7. Tournez la manette de réglage du gaz jusqu’à la position de marche
“ON”. Ne la forcez pas.
8. Ouvrez le courant électrique (“ON”) qui alimente l’appareil
(interrupteur mural).
14
5. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.
Interrupteur
ON/OFF
CONTROL
OFF
ON
IG
N
ITE
Vue de face
I
PSI
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Pour une fermeture complète, tournez l’interrupteur mural à la
position d’arrêt “OFF”.
2. Ouvrez la porte du compartiment de contrôle du bas.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9. Fermez la porte du compartiment de contrôle du bas.
10. Au besoin, rebrancher l’apareil au courant électrique et
remettre l’interrupteur principal du brûleur à la position “ON”
ou régler le thermostat à la température désirée.
11. Si l’appareil ne se met pas en marche, suivre les instructions
intitulées “Pour fermer le gaz qui alimente l’appareil” et
appeler un technicien ou le fournisseur de gaz.
POUR ÉTEINDRE L’APPAREIL
1. Coupez tout le courant électrique qui alimente l’appareil (interrupteur
mural).
3. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.
Ne la forcez pas.
4. Fermez la soupape d’arrêt de la canalisation principale.
5. Fermez la porte du compartiment de contrôle du bas.
Page 15
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM
Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in
the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
1. Spark ignitor will not light
pilot after repeated triggering of ignitor button.
2. Pilot will not stay lit after
carefully following the
lighting instructions.
3. Pilot burning, no gas to
burner, Valve knob “ON,”
Wall Switch “ON.”
POSSIBLE CAUSES
A. Defective ignitor
(no spark at electrode).
B. Defective or misaligned electrode
at pilot (spark at electrode).
C. Gas supply pressure errant.
D. Pilot orifice plugged.
A. Defective pilot generator
(thermocouple).
A. Wall switch or wires defective.
CORRECTIVE ACTIONSYMPTOM
Check for spark at electrode and pilot; if no spark and
electrode wire is properly connected, replace ignitor.
Using a match, light pilot. If pilot lights, turn off pilot and
trigger the ignitor button again. If pilot lights, an improper gas
mixture caused the bad lighting and a longer purge period is
recommended. If pilot will not light – check gap at electrode
and pilot – should be ¹⁄₈" to have a strong spark. If gap
measures ¹⁄₈", replace pilot
Check inlet gas pressure. It should be within the limits as
marked on the rating plate.
Clean or replace pilot orifice.
Check pilot flame, it must impinge on thermocouple
9 on page 7)
impingement on thermocouple. Ensure that the connection
between the valve and thermocouple are tight and secure.
Check wall switch and wires for proper connections. Jumper
wire across terminals at wall switch, if burner comes on,
replace defective wall switch. If okay, jumper wires across wall
switch wires at valve, if burner comes on, wires are faulty or
connections are bad.
Clean and/or adjust pilot for maximum flame
(Figure 9 on page 7)
.
(Figure
4. Frequent pilot/burner outage
problem.
B. Thermopile may not be generating
sufficient millivoltage.
C. Plugged burner orifice.
A. Pilot flame may be too low or
blowing (high) causing the pilot/
valve safety to drop out.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 325 millivolts minimum with optional wall switch “OFF.” Replace faulty thermopile if reading is below specified minimum.
Check burner orifice for stoppage and remove.
Clean and/or adjust pilot flame for maximum flame impingement on thermocouple
(Figure 9 on page 7)
.
15
Page 16
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
N
ote: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in
the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOMPOSSIBLE CAUSESCORRECTIVE ACTION
1. Burner will not light.
2. Burners come “ON” but
go “OFF.”
START
• Turn Off Gas Supply
• Assure Valve Switch Is In ON Position
• Disconnect Control Harness
• Set Thermostat To Call For Heat
Insert A
24 Volt Hot
24 Volt
Switched
Check For Damaged Or Missing Terminals
In Connector
Insert B
Igniter Terminals
End View Of
Control Harness
Connector
A. Faulty Valve System.
B. “OFF/ON” or wall switch
defective.
A. Burner orifice plugged.
B. Obstructed vent system.
• Check For Proper Voltage At Control Harness
(See Insert A). Voltage Should Be 24V
Between Thermostat Or Pressure Switch
And 24V Common And 24V Hot.
• Plug Control Harness Into Valve. Wait For
Internal Check Delay.
• Igniter Warms Up And Glows Red.
24 Volt
Common
• Turn On Gas Supply. • Pilot Burner Lights.
See Below.
Disconnect the two black wires from the wire nuts. Test switch(s) for
continuity with a multimeter. If continuity is not indicated, switch(s) is
defective and must be replaced.
Note: Before replacing “OFF/ON” switch, be sure to check wiring for loose
connections or broken wires and repair as needed.
Check main burner orifice(s) for stoppage. Clean or replace.
Check vent system for obstructions.
CHECK
• Line Voltage Power
NO
• Low Voltage Transformer
• Limit Controller
2
YES
1
YES
YES
• Thermostat
• Wiring
• With Pilot Burner Cable Connected, Measure
NO
Voltage At Valve HSI Element Output. 24V
Nominal. (See Insert B)
YES
• Replace Igniter/Flame Rod Assembly.
YES
NO
• Check That Pilot Gas Is Flowing. Wait To
Assure Plot Gas Tubing Is Purged. Recycle
Call For Heat If Necessary.
YES
• Measure Voltage Between 24V Hot And 24V Common
Leads To Valve Control. Must Measure At Least 19.5
VAC With Igniter Powered (See Insert A). To Identify
Proper Lead, This Check Must Be Done With The
Valve Control Connected And Igniter Powered.
YES
• Replace Pilot Assembly.
NO
2
1
• Replace Valve.
NO
• Replace Valve.
NO
• Check Transformer And
Line Volt Supply.
16
Igniter Will Cycle Off And Back On Once During
1
The 90 Second Ignition Trial. All Voltage
Measurements Must Be Taken While The Igniter
Is Powered.
• Main Valve Opens And Main Burner Lights.
YES
• System Is Okay.
When Measured Voltage At Connections, Use
2
Care To Assure Terminals Are Not Damaged.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
• Check That Pilot Flame Makes Good Contact With
Pilot Burner Flame Rod.
NO
• Check For Good Electrical Connection Through The
Pilot Tubing.
• If Both Of The Above Are Good, Replace Igniter/Flame
Rod Assembly.
LENNOX reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.