Lennox CA210 User Manual

INSTALLATION AND OPERATION MANUAL
EPA Certified
Wood-Burning
Fireplace Inserts
Save These Instructions
For Future Reference
P/N 775212M, Rev. C, 09/2011
A French manual is available upon request. Order P/N 775212CF.
Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de
la pièce 775212CF.
Performer™ C210
and SWI210
Performer™ CA210
Wood Fireplace Inserts
Performer™ Models C210,
CA210 and SWI210
This appliance must be properly installed and operated in order to prevent the
possibility of a house fire. Please read this entire installation and operation
manual before installing and using your wood fireplace insert. Failure
Portland
US
Report No. 050-S-03b-2
to follow these instructions could result in property damage, bodily
injury or even death. Contact your local building or fire officials
to obtain a permit and information on any installation re-
quirements and inspection requirements in your area.
WARNINGS
• Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result.
• Carefully supervise children in the same room as appliance.
CONGRATULATIONS!
When you purchased your new wood-burning fireplace insert, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthet­ics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new wood-burning fireplace insert.
Thank you for selecting a Lennox Hearth Products wood-burning fireplace insert as the answer to your home heating needs.
TABLE OF CONTENTS
Using This Manual ......................................................................... 2
Important Safety Information ......................................................... 3
Testing Information ........................................................................ 4
Draft Requirements ........................................................................ 4
Selecting the Proper Venting System ............................................. 4
Negative Pressure Warning ............................................................ 5
Creosote ......................................................................................... 5
Ash Disposal .................................................................................. 5
Fuel ........................................................................................... 5
Burn-In Period ...............................................................................5
Paint Curing ................................................................................... 5
Brick Installation ............................................................................ 6
Required Clearances ...................................................................... 7
Hearth Protection ........................................................................... 8
Chimney Requirements .................................................................. 9
Installation Procedures-Masonry Chimney ....................................9
Positive Flue Connection .............................................................. 10
Installation Procedure - Factory-Built Zero Clearance Fireplaces 10
Fireplace Pre-Installation Preparation ..........................................10
Insert Pre-Installation Preparation ............................................... 10
Chimney Liner Installation ........................................................... 12
Installing the Insert ...................................................................... 12
Post Installation Checks ............................................................... 12
Operating Hints ............................................................................ 13
Starting and Maintaining a Fire ....................................................13
Blower Operation (optional kit) .................................................... 14
Operating Techniques and Hints................................................... 15
Getting the Most Out of Your Fireplace Insert .............................. 15
Maximizing Your Fireplace Insert’s Overall Efficiency ................... 15
Achieving Clean, Long Burns ....................................................... 15
Maintenance ................................................................................. 16
Clean Glass .................................................................................. 16
Troubleshooting ...........................................................................17
Do’s and Don’ts ............................................................................ 18
Replacement Parts List ...........................................................19-21
Accessories .................................................................................. 22
Safety / Listing Labels .................................................................. 23
Product Reference Information .................................................... 24
USING THIS MANUAL
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual.
PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE
2
IMPORTANT SAFETY AND WARNIING INFORMATION
READ THIS MANUAL IN ITS ENTIRETY AND UNDER­STAND THESE RULES TO FOLLOW FOR SAFETY.
1. When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
2. Wear gloves during installation to avoid injury from sharp edges on the insert and/or its parts.
3. This unit is designed and engineered to burn only dry, well­seasoned wood. Burning wet wood will greatly reduce your inserts efficiency, produce excessive amounts of smoke and can cause dangerous chimney fires due to creosote build­up.
4. Before opening the door, the draft control must be fully open to avoid possible combustion flash (ignition of hot volatile gases as the door is opened).
5. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ’freshenup’ a fire in this heater. Keep all such liquids well away from the heater while it is in use.
6. While burning, fuel utilizes oxygen from the air in the room. Be sure to allow an adequate amount of fresh air into the room where the insert is burning.
7. The outside surface of the insert will be hot while burning properly and can set items like clothing and curtains on fire. Keep furnishings and other combustible materials away from the insert. Using the heat from the insert to dry wet clothing can be hazardous if clothes are placed too near the surface of the insert.
8. Do not allow children to play near the insert without close supervision. Do not touch the insert while it is burning. Use extreme caution while the unit is in use. Surface temperatures become dangerously hot and can cause serious burns.
9. Do not allow anyone to operate the insert who is not familiar with the operating instructions.
10. Attempts to achieve heat output rates that exceed insert design specifications can result in permanent damage to the insert. Never leave your insert unattended on high burn rates. This may cause overfiring. Overfiring the insert may cause a house fire. If the insert glows, you are overfiring.
11. Keep a water hose or hand-operated fire extinguisher close for safety.
12. Smoke Detectors - Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. If possible, install the smoke detector in a hallway adjacent to the room (to reduce the possibility of occasional false activation from the heat produced by the insert). If your local code requires a smoke detector be installed within the same room, you must follow the requirements of your local code. Check with your local building department for require­ments in your area.
13. Inspect your chimney at least once a month during the burn­ing season to check for soot and creosote accumulations. Any accumulations over 1/8” thick should be removed by a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire. If large accumulations are occurring, review your burning procedures.
14. If a creosote fire should develop, the fire department should be called immediately and then attempts should be made to control the fire until assistance arrives. If a “runaway” fire should develop causing over-heating of the insert, the door and draft regulators should be closed immediately. The fire should die down once deprived of oxygen. After a severe chimney fire, the complete chimney system should be checked before further use.
15. Do Not Use Grate Or Elevate Fire - Build Wood Fire Directly On Hearth (firebrick). Do not use andirons or other methods of supporting the fuel.
16. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death.
17. Check all local building and safety codes before installation. The installation instructions and appropriate code require­ments must be followed exactly and without compromise. In the absence of local codes the following standards and codes must be followed.
18. In the U.S.A, install in accordance with the National Fire Protection Association’s Code, NFPA 211, Standards for Chimneys, Fireplaces, Vents and Solid-Fuel-Burning Appli­ances, or similar regulations, may apply to the installation of a Solid-Fuel-Burning appliance in your area. In Canada, the guideline is established by the CSA Standard, CAN/CSA-B365­M93, Installation Code for Solid-Fuel-Burning Appliances and Equipment.
19. Do not connect to any air distribution duct or system.
20. WARNING: BURNING IMPROPER FUEL (I.E. CHARCOAL)
CAN RESULT IN CARBON MONOXIDE POISONING, WHICH MAY LEAD TO DEATH!
21. Carbon Monoxide Poisoning – early signs of carbon monox- ide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, get fresh air at once! Have the heater inspected by a qualified service technician. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
22. Failure to use manufacturer provided parts, variations in techniques and construction materials or practices other than those described in this manual may create a fire hazard and void the limited warranty.
23. Do not make any make-shift compromises during installation. Any modification or alteration may result in damage to the appliance or dwelling and will void the warranty, certification and listings of this unit.
24. These appliances are designed as supplemental heaters. Therefore, it is advisable to have an alternate heat source when installed in a dwelling.
25. Do Not Overfire – If Heater or Chimney Connector Glows,
You Are Overfiring.
26. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
3
TESTING INFORMATION
Less than
10' (3 m)
10'
(3 m)
3' (914 mm)
Min.
2’ (610 mm) Min.
(914 mm)
Min.
3'
This manual describes the installation and operation of these non-catalytic wood heaters. These heaters meet the U.S. Environmental Protection Agency’s emissions limits for wood heaters sold on or after July 1, 1990. This heater has been developed, tested and constructed in accordance with the requirements of UL 1482, ULC S628 and HUD standards and is listed by OMNI Test Laboratories, Portland, OR. It has been approved for residential and alcove installations.
DRAFT REQUIREMENTS
read greater than .04’ W.C. (inches water column) and less than .08” W.C. As per NFPA-211 standard (see paragraph below), the installer
must take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance. See Chimney Guidelines below to assist you in selecting the proper venting system for your installation.
American National Standards Institute ANSI/NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances
- See Draft Section: A chimney or vent shall be so designed and con-
structed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere. The venting system shall satisfy the draft requirements of the connected appliance in accordance with the manufacturer’s instructions.
Your wood fireplace insert is dependent upon a properly functioning chimney for optimum performance. It is a high efficiency appliance that loses much less heat up the chimney than older appliances and fireplaces. For this reason it is important to match the fireplace insert to the chimney. The chimney has two functions:
1. It draws combustion air into the appliance (without air, no fuel will burn) and
2. It exhausts combustion by-products. Your new appliance is what is known as a “natural draft” appliance.
The appliance depends solely on the natural draft of the chimney system to draw combustion air into the unit. Draft is the force that moves air from the appliance up into the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance (overfiring). Slow or inadequate draft equals poor combus­tion and possible smoking problems. The following are some conditions that may contribute to poor chimney draft:
1. A chimney too large for your appliance.
2. A chimney with not enough height to produce adequate draft.
3. A chimney with excessive height (this may allow exhaust to cool too much before exiting, which will stall the rate the exhaust exits).
4. Offsets in the venting system are too restrictive (see Chimney Guide- lines).
Inadequate draft will cause the appliance to leak smoke into the room through the fireplace insert and the chimney connector joints.
Excessive draft may cause an uncontrollable burn or a glowing red fireplace insert or chimney part.
Chimney Guidelines:
• This appliance requires approximately 12 feet minimum of “effective draw” provided by the venting system. As a rule of thumb, every 90 degree total direction change in the venting will result in a loss of approximately 5 feet of “effective draw.” Example: If two 45 degree offsets are used, subtract 5 feet from the actual vertical vent height to determine your “effective draw.” In this case if you had 14 feet of vertical vent, the effective draw would only be approximately 9 feet (14 ft. - 5 ft. = 9 ft.), therefore it may be necessary to add additional height to the venting system.
• In well insulated and weather tight homes, it may be difficult to establish a good draft up your chimney. The poor draft is caused by a shortage of air in the house (see Negative Pressure Warning on Page 5).
Chimney Height Requirements
The chimney must extend 3’ (.92m) above the level of roof penetration and a minimum of 2’ (.61m) higher than any roof surface within 10’ (3m) (see below). Check with your local building officials for additional requirements for your area.
Overfiring Damage - If the heater or chimney connector glows, you are overfiring. Other symptoms may include: Cracking, warping or burning out of components, plated accessories may turn color, stove glass may develop a haze, which will not come off with cleaning.
Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached, beyond the design capabilities of the appli­ance. The damage that occurs from overfiring is not covered under the manufacturer’s limited warranty.
Also see Troubleshooting on Page 17.
SELECTING THE PROPER VENTING SYSTEM
The appliance is merely one component of a larger system. The other equally important component is the venting system. This is necessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion by-products from the appliance. If the venting system’s design does not promote these ends, the system may not function properly. Poorly functioning venting systems may create performance problems as well as be a safety hazard. A draft test should
4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 1 - Chimney Height Requirements
To pass inspection in nearly any jurisdiction, the chimney must meet both safety and exhaust flow requirements. The (3’ by) 2’ by 10’ rule applies to both masonry and factory-built chimneys.
* Ref. USA - National Standard, NFPA 211-latest edition and Canada National Standard CSA B365-01-latest edition. Vents installed with a listed cap shall terminate in accordance with the terms of the cap’s listings.
NEGATIVE PRESSURE WARNING
This appliance is not designed to be operated in a negative pressure. In very airtight homes with large kitchen exhaust fans, furnace cold air returns, fresh air exchange systems and any other air system in close proximity to the heating appliance may create a negative pressure in the same room as the heating appliance. This can create dangerous back drafting of the fireplace insert and chimney joints, drawing combustion by-products into the home. Be sure your home has adequate makeup air to eliminate negative pressures caused by the above-mentioned sources. Lennox Hearth Products accepts no liability for damages resulting from negative pressures described above.
Ventilation Requirements - Provide adequate air for combustion. The fresh air requirements of this appliance must be met within the space where it will be installed. Ventilation is essential when using a Solid-Fuel­Burning heater. In well insulated and weather tight homes, it may be difficult to establish a good draft up the chimney (caused by a shortage of air in the home). The lack of air is caused by many common household appliances which exhaust air from the home (such as a furnace, heat pump, air conditioner, clothes dryer, exhaust fans, fireplaces, and other fuel burning appliances). Also, the combustion process of this heater uses oxygen from inside the dwelling. If the available fresh air delivery in the dwelling is insufficient to support the demands of these appliances, problems can result (i.e. excessive negative pressure can develop in the dwelling which will affect the rate at which this appliance can draft thus resulting in performance problems. To correct this problem it may help to open a window (preferably on the windward side of the house).
CREOSOTE, FORMATION AND NEED FOR REMOVAL
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney and chimney connector should be inspected at least once monthly during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.
Dry, seasoned wood is that which has been cut, split and allowed to dry under a covered area where air is free to flow and circulate under and around the wood (not under a tarp or plastic). Make sure wood is not stacked directly on the ground, it may absorb moisture from the ground. It should be allowed to dry in these conditions for a minimum of six months, preferably one year or more. IT MUST BE UNDERSTOOD THAT
WOOD CANNOT BE LEFT IN ANY KIND OF WET OR DAMP AREA OR IT WILL NEVER BECOME COMPLETELY SEASONED. Your fireplace insert
will not operate at the level that it is meant to unless you use seasoned, dry wood. Do not burn driftwood or wood that has been in salt water, doing so will void your warranty. Do not burn treated wood, coal, garbage, cardboard, solvents, or colored paper. Burning treated wood, garbage, solvents, or colored paper may result in the release of toxic fumes. This type of burning will also void your warranty.
PAINT CURING
If your fireplace insert has plated accessories, be sure to clean it with a household type glass cleaner and a very soft cloth to remove any fingerprints and residues prior to the first fire and before any fire if the gold has been handled or soiled. Do not close the door tightly during the “Burn-In Period.” Also, open the door frequently (every 5-10 minutes) to keep the gasket from adhering to the curing paint.
Ventilate the house well during these first firings as the paint gives off carbon dioxide and unpleasant odors. It is recommended that persons sensitive to an imbalance in the indoor air quality avoid the fireplace insert during the curing process.
Your new appliance is painted with a high temperature paint that cures during the first few firings. We recommend that you put your fireplace insert through a regimen of three burns. The first two should last for 20 minutes each at 250 degrees (the fireplace insert should be allowed to cool completely between each burn). The third should be a burn of at least 450 degrees F. for 45-60 minutes. The paint will become soft, gummy and emit non-toxic smoke during these burns. After the fireplace insert cools down for the third time, the paint will harden. DO NOT BUILD A
LARGE ROARING FIRE UNTIL THIS CURING EFFECT IS COMPLETE OR YOU MAY DAMAGE THE FINISH OF YOUR STOVE OR INSERT. Spray
can touch-ups should be done only with a high temperature stove paint (cat. no. H8159), available from all Lennox Hearth Products dealers.
BURN-IN PERIOD
DISPOSAL OF ASHES
Ashes should be scooped out of a cool fireplace insert with a small metal shovel. Ashes should be placed in a metal container with a tight fitting lid and moved outdoors immediately. Other waste shall not be placed in this container. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all the cinders have thoroughly cooled. Ashes can ignite up to 72 hours after removal from the fireplace insert.
FUEL
This unit is designed and engineered to burn, dry, well-seasoned wood only.
Please be patient with the heat output of your fireplace insert for the first few weeks. The steel will go through a curing process that eliminates moisture, which is deep in the steel and firebrick. This moisture will reduce initial heat output of your fireplace insert and may make it dif­ficult to start. After you have broken in the paint on the fireplace insert it will be necessary to build hot fires to thoroughly remove the moisture from the appliance. Running the fireplace insert with the draft fully open for 1 to 1-1/2 hours after starting and adding generous amounts of fuel during the first week or two should complete the curing process. We recommend the use of a thermometer attached to the fireplace insert top or chimney. Temperatures on the connector pipe should run in the 250-600 degree range.
(DO NOT OVERFIRE THE STOVE OR INSERT DURING THIS PROCESS. IF THE STOVE OR CHIMNEY BECOMES RED, REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY).
5
BRICK INSTALLATION
CAUTION: Wear gloves during brick installation in case of sharp edges behind the fireplace insert.
Note: Installation of the baffle boards and baffle blankets are easier when you can still access the flue outlet, (before connecting the flue vent). Be
sure the baffle blankets are placed flat on the baffle boards so as not to block exhaust flow to the flue. Use a ruler or a piece of kindling to
reach over the baffle blanket to be sure it is completely flat on top of the baffle boards.
Measure bricks before installing, as per list of dimensions on next page, to be sure the correct bricks are installed in the correct location.
1. Install bricks #1-26 in the numbered sequence shown in Figure 2. Important: The secondary burn tubes at the top of the firebox are
supported by a metal bracket. Move this bracket so it is centered left and right on the tubes. Also make sure the small supporting brackets on the front and rear tubes are centered and hanging from the steel rods at the front and rear of the fireplace insert.
2. Next, you will install the baffle boards. All 4 baffle boards included are the same size which is 15” x 4-3/4”. You will start by installing the boards in the center part of the unit on top of the secondary tubes to each side of the baffle support with the 15” side of the baffle board going from the front to back of the unit. Once you have the first two boards installed slide the board to the left side of the baffle support all the way to the left and rear of the unit. You will slide the board to the right side of the secondary support to the right and rear of the unit. Next you will install the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit. The stainless steel support hanger should be centered left to right between the sets of baffle boards and placed as shown in Figure 4.
3. Also included with the unit are two 15” x 10” x 1” thick baffle blan­kets. Install each blanket above the baffle board to each side of the secondary support with the 15” side of the blanket from front to rear of the unit. Make sure that the baffle blankets are to the full rear of the unit.
4. Also included with the unit are two 15” x 10” x 1” thick baffle blan­kets. Install each blanket above the baffle board to each side of the secondary support with the 15” side of the blanket from front to rear of the unit. Make sure that the baffle blankets are to the full rear of
the unit.
CAUTION: Make sure the baffle blankets are down flat on the baffle boards, pulled together in the center so that no gaps exists between them and do not protrude beyond baffle boards. It is critical that baffle boards and baffle blankets are fully against the rear of the unit.
Firebox Brick Layout Viewed From the Front
Figure 2
9
S
24
E
1 F
6*
F 7 F
8 F
14
F
19
B
25
H
3
2
G
F
15
16
F
G
21
20
K
B
26
E
4
5
F
17
F
22
B
10*
F
F
11
F
18
F
12
F
13
S
23
B
* Bricks 6 and 10 fit up against the back of the firebox.
Front View - See the following for brick sizes
*Fits against the back of the firebox.
Note: These bricks may be slightly smaller to adjust for steel and fire­brick tolerances beyond our control. Be sure to measure and mark bricks with their numbers when removing.
Baffle
15”
Insulation Parts
1” Thickness
Two Baffle Blankets Per Unit
15”
1/2” Thickness
Four Boards Per Unit
10”
4-3/4”
Figure 3
Side Cut-A-Way View of Firebox
Baffle Blankets
WARNING: IF THE BRICKS ARE NOT INSTALLED EXACTLY AS SHOWN BELOW, THEY COULD FALL OUT OF PLACE DURING REFUELING OR BURNING OF THE FIREPLACE INSERT CAUSING SERIOUS INJURY!
Brick Sizes (see Figures on this page)
E = 3 x 9” H = 1-1/2 x 3” F = 4-1/2 x 9” K = 1-1/2 x 5-1/2” G = 1-1/2 x 9” S = 2-1/8”
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Baffle Board
Firebox Brick
Figure 4
REQUIRED CLEARANCES
WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC­TION IS NOT LESS THAN SHOWN ON THIS PAGE.
Model *A *B *C *D E(1)
C/A210 SWI210
C/A210 & SWI210
w/mantel and/or
side shields u
Model F (1) G H J(2) M
C/A210
SWI210
C/A210 & SWI210
w/mantel and/or
side shields u
USA-24”
CAN-
813mm
USA-16”
CAN-
813mm
18”
450mm
18”
450mm
USA -18”
CAN-
660mm
USA -10”
CAN-
660mm
12-1/4”
311mm
12-1/4”
311mm
18”
450mm
18”
450mm
19”
483mm
19”
483mm
15”
381mm
USA-8”
381mm
4-1/2”
114mm
4-1/2”
114mm
USA-
CAN-
200mm
USA-
CAN-
200mm
42-1/8”
1070mm
34-1/8”
867mm
8"
8"
SIDE WALL
Figure 5
Maximum Mantel Depth = 9” (229mm)
COMBUSTIBLE MANTEL
Top Facing / Trim
B
D
Side Facing Material
C
E (USA)
A
Insert
Hearth Protection
E (Canada)
Mantel
* Reduced clearances may be available for A, B, C and D dimensions per
NFPA 211 - latest edition, Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances (in Canada CSA B365 - latest edition). See section on “Reduction of Appliance Clearance with Specified Forms of
Protection.” ** Side view of optional mantel deflector shown. (1)Hearth extension reductions: 2” (51 mm) reduction for 2” (51 mm) raised
hearth. (USA) 16” minimum hearth extension on all stoves and inserts
as measured from the door opening of the unit. (Canada) 18”(450 mm)
minimum hearth extension on all stoves and inserts as measured from the
door opening of the unit. Minimum distance of floor protection to the side
= 8” (200 mm). This is measured from the sides of the door opening in the
USA and from the sides of the insert in Canada. (2) J = Maximum lintel depth without flue offset or smoke deflector.
Notes:
• Facing material that projects more than 3/4” (19 mm) from the wall
is considered a mantel or side wall.
C/A210
SWI210
Depth Min. 12-1/2” (318mm) 12-1/2” (318mm)
Height Min. 21” (533mm) 19-1/4” (489mm)
Width Min. 36” (914mm) 26” (660mm)
Lintel Max. Depth
Without use of adjustable offset box or smoke deflector
u
u
ZC Fireplace
UL 127
4-1/2” (114mm) 4-1/2” (114mm)
Masonry Fireplace
UBC Chapter 37
Table 1 - Fireplace Sizing
M
Figure 6
F
Hearth Protection
**
229mm
Top View
Trim
9”
J
G
6” Ø
Flue Collar
H
Figure 7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
23”
584mm
25-1/2” 648mm
7
HEARTH PROTECTION
The hearth and/or floor protection must be a thermally rated non-com­bustible hearth/floor protector meeting or exceeding a thermal rating of k=.84 or equivalent with a listed thickness of 3/8" (9.5mm) minimum in USA (3/4" - 19mm minimum in Canada). The covering must extend 18” (450mm) in front of the heater and 8” (200mm) to either side (measured from door opening in the USA and measured from the side of the unit in Canada).
Using Alternate Material As Floor / Hearth Protection
The hearth extension or alternate material used as a floor/hearth protec­tor must be constructed of a durable noncombustible material having an equal or better thermal conductivity value (lower k value) of k =.84 BTU/IN FT2 HR °F or a thermal resistance that equals or exceeds r = 1.19 HR °F FT2 IN/BTU with a minimum thickness of 3/8” in USA or 3/4” in Canada. With these values, determine the minimum thickness of the alternate material required using the formula(s) and shown in Table 2
for USA and Table 3 for Canada.
Note: Any noncombustible material having a minimum thickness of
3/8”(9.5 mm) for USA or 3/4” (19mm) in Canada whose k value is less than .84 or whose r value is more than 1.19 is acceptable. If the alternate material used has a higher k value or lower r value will require a greater thickness of the material used. In some cases, if the k value is less or the r value higher, a thinner material may be used.
Methods of determining floor protection equivalents:
To determine the thickness required for the alternate material when either the "k" value or "r" value is known, use either the k formula or r
formula.
Example: If Micore 160 Mineral Fiber Board is to be used for the floor
protection, how thick must this material be?
k
= k value per inch of alternate material
M
rM = r value per inch of alternate material
TM = minimum thickness required for alternate material T
= standard thickness of the alternate material
S
k
= k value per inch of listed material
L
rL = r value per inch of listed material
= minimum thickness of listed material
T
L
Note: An asterisk "*" indicates, it is a value taken from Tables 2 and 3. Using the k formula:
FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS
Using the k formula:
Minimum k-value (per Inch) of Specified min. thickness of = alternate material (k alternate k-value (per inch) of listed material (T
(inches) = kM x TL
T
M
) of listed material (kL) material (TL)
M
) x thickness
M
*.84
(inches) = *.35 x .375"
T
M
*.84
.156 (inches)= .417 x .375"
Answer - The minimum required thickness of the Micore 160 is .156" therefore round up to nearest standard thickness available which is 3/8” (.375”)
8
Using the r formula:
Minimum r-value (per Inch) Specified min. thickness of = of listed material x thickness alternate r-value (per inch) of listed material of alternate material material
(inches) =
T
M
r
(inches) = *1.19 x .375"
T
M
r
L x T
M
L
*2.86
.312 (inches)= .416 x .375"
Answer - The minimum required thickness of the Micore 160 is .156" therefore round up to near est standard thickness available which is 3/8” (.375”)
Listed Material
k (per inch) r (per inch) Listed Min. Thickness
Listed Material .84
** Approved Alternate Materials for Floor/Hearth Protection
Alternative Materials Thermal Values Minimum Thickness
Kaowool M Board .47 2.13 .42" (1/2")
Micore 160™
U.S. Gypsum
Micore 300™
U.S. Gypsum
Durock™ Cement Board
U.S. Gypsum
Hardibacker™ 1.95 .51 1.74" (1-3/4")
Hardibacker 500™ 2.30 .43 2.05" (2-1/8")
Cultured Stone Hearth­stone™
Wonderboard 3.23 .31 2.88" (3")
Super Firetemp M
Johns-Manville
Super Firetemp L
Johns-Manville
Face brick 9.00 .111 8.04" (8-1/8")
Common brick 5.00 .20 4.46” (4-1/2")
Cement mortar 5.00 .20 4.46” (4-1/2")
Ceramic tile 12.5 .08 11.16" (11-1/4")
Marble ~11 ~.09 9.82" (9-7/8")
K
L
k (per inch)
K
M
.35 2.86 .31" (3/8")
.46 2.17 .41" (1/2")
1.92 .52 1.71" (1-3/4")
2.82 .35 2.52" (2-5/8")
.61 1.64 .54" (5/8")
.54 1.85 .48" (1/2")
1.19
r
L
r (per inch)
r
M
3/8" (.375")
T
L
(rounded to nearest 1/8 inch)
Min. Thickness
T
M
Table 2 - USA REQUIREMENTS
** If the hearth extension material(s) that is intended to be used is NOT listed on Table 1, the material can still be used if the material(s) is noncombustible. However, the manufacturer of the material must provide either the listed k-value per inch or r-value per inch with listed thickness so that the minimum thickness required for the hearth can be calculated (per instructions here or as specified in the NFI Certification Manuals).
Note: Also see NFI (National Fireplace Institute) Certification Manuals show­ing other acceptable calculation methods and acceptable alternate materials which can be used.
SEE TABLE 3 ON FOLLOWING PAGE FOR CANADA REQUIRE­MENTS