SOLID STATE DEFROST
REPLACEMENT BOARD
LB-83114C (61H42) USED ON HP7-1, -2, HP8, CliP9 AND CliP10 SERIES UNITS
,/SHIPPINGANDPACKING _ : : :: : ]
Package 1 of 1 contains:
1- Control board on mounting bracket 1- Defrost thermostat
1- Outdoor fan/defrost relay
8- Wires with 3/16" terminals
1- Screw
2- Wire nuts
/tNSTA_TiON: :
1- Turn off power supply to unit. 2- Remove compressor access panel and control
box cover.
A- Defrost Thermostat
3- Disconnect coil thermistor from coil return bend
and air thermistor from fan section. Replace coil thermistor with provided defrost thermostat.
Secure to liquid line as close as possible to the outdoor coil.
NOTE-/t may be necessary to remove the front corner
panel for access to coil thermistor,
B-Defrost Board
4- Remove and retain screwfrom existing solid state
defrost board located in control box. Note existing wiring. See figure 1.
5- Install newcontrol board assembly using existing
screw and hole.
6- Drill new hole into control panel and secure with
screw provided in kit.
C-Outdoor Fan/Defrost Relay
7- Remove outdoor fan/defrost relay. Install
replacement outdoor fan/defrost relay.
1- Connect one end of long wire (provided) to "HLD"
terminal on the defrost board. Disconnect defrost
high pressure switch from between high pressure switch and loss of charge switch.
2-Splice remaining end of long wire to wire
between high pressure switch and toss of charge
switch where high pressure switch was originally connected.
3- Connect onewire from defrost relaycoitto "OUT"
terminal of defrost board.
4- Cut off terminal of remaining wire from defrost
relay coil and strip wire 5/8 inch. At a convenient location, splice wire to long wire from "HLD"
terminal using a wire nut.
5- Connect wire from defrost thermostat to one of
the "24V" terminals on defrost board.
IMPORTANT-Make sure defrost thermostat is securely fastened to the fiquid line.
6- Cut off terminal from remaining defrost
thermostat wire and strip wire 5/8 inch. Splice with one of the defrost pressure switch wires
using a wire nut.
7- Locate blue transformer wire and splice with
remaining defrost high pressure switch wire using a wire nut.
8- Connect the remaining existing wire to "COM"
terminal on defrost board.
9- Defrost time interval can be selected to defrost
every 30, 60 or 90 minutes. This is selected using the jumper on the defrost board.
10-Replace all panels and restore power to unit.
Page 1
TOP VIEW FRONT VIEW
REPLACEMENT
BOARD
_J
f
REMOVE
EXISTING BOARD
Use existing hole to
install replacement board
I
®1
Drill new hole into
control box panel
FIGURE 1
DEFROST TIME
INTERVAL JUMPER
9O
6O
0 _o
RST
HLD
24V
OUT
COM
_ INTERNAL
JUMPER
_] HIGH
PRESSURE
SWITCH
LOSS OF
, CHARGE ._ SWITCH
DEFROST
BOARD
COMPRESSOR
CONTACTOR
TYPICAL WIRING
RST 0
HLD
24V * _)-
OUT (_
tOM9
EXISTING TRANSFORMER
COMMON YELLOW WIRE
DEFROST THERMOSTAT
OUTDOOR FAN AND
DEFROST RELAY
EXISTING TRANSFORMER
24V POWER BLUE WIRE
DEFROST HIGH
PRESSURE
SWITCH
*NO TE-- No external/umper tsrequtred for
24VAC terminals. The 2,4V terminals are jumpered lnternal/}z Either termina/ may be
connected to defrost thermostat•