INSTALLATION INSTRUCTIONS FOR OUTSIDE COMBUSTION AIR GATE KIT FOR USE WITH UVF-36,
UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H UNIVERSAL VENTFREE FIREBOXES
KIT CONTENTS
ITEM QUANTITY DESCRIPTION
1 1 ea. Air Gate Assembly
3 1 ea. Bracket, Air Gate Arm
4 1 ea. Collar, Outside Air
5 1 ea. Duct, 4”
6 1 ea. Hardware Kit (9 long screws & 4 short screws)
7 1 ea. Instruction Sheet
Table 1 - Refer to Figure 1
6
5
750,206M REV. NC 03/2006
1
Cat. No. Model Description H3991 OAK-UVFRC OUTSIDE AIR GATE & DUCT KIT
WARNING
Do not operate the combustion air gate with a fi re in the fi rebox unless all components of this kit have been installed.
Side View of Arm
Right Hand Side of Firebox
Remove Outside Air Knock-Out
installed into Air Gate.
Air Gate Assembly
1
7
2
4
3
Figure 1 - Kit Contents (see Table 1)
TOOLS / SUPPLIES REQUIRED
• 5/16” Nut driver or Socket • Duct Tape • Silicon Type Caulking
GENERAL INFORMATION
This kit is for use with models UVF-36, UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H Ventfree fi reboxes when installed in con­ventional construction.
These kits have an air gate assembly which allows adjustment of the amount of outside air delivered to the fi re for combustion. Only one air kit, located on the right side of the fi rebox, is required.
If you encounter any problems, need clarifi cation of these instructions or are not qualifi ed to properly install this kit, contact you local distributor or dealer.
Retain These Instructions for Future Reference
INSTALLATION INSTRUCTIONS
1. Remove the outside air knock-out on the right hand side of appliance
(See Figure 2 for location).
2. Assemble the Air Gate as shown in Figures 3 & 4.
3. Take the Air Gate Assembly and feed the arm
through the round opening (see Figures 5 & 6) and then through the side frame opening. Ensure the air gate arm remains attached to the air gate (see Figure 7).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 2
Air Gate
Figure 4
Air Gate Arm
Figure 3
Air Gate Arm
Outside View of Arm installed into Air Gate.
When assembled onto appliance, the notch here must be positioned down as shown.
Air Gate
Air Gate Arm
Right Side Panel on Firebox
Figure 5
1
5. Secure the air gate arm support bracket (item
#3 in Figure 1) as shown in Figure 9.
Slot
Locate this slot on right side panel of fi rebox.
Secure the duct to
the collar using
duct tape as
shown.
Collar
Figure 11
Hold the air gate arm and align the air gate assem­bly to fi t fl ush in the opening.
Figure 6
Front right side of fi rebox opening
Locate this opening
Air Gate Arm
CLOSED POSITION
OPEN POSITION
Feed the bent end of the air gate arm into this notched opening.
Figure 7
4. Secure the air gate to the fi rebox as shown in Figure 8.
Right Side of Firebox
Ensure this
Air Gate
Secure the Air Gate to the fi replace with four (4) long screws (provided) through the outside holes (indicated by arrows).
notch is positioned on the bottom half of air gate.
Figure 8
Insert the arm support bracket as shown. Adjust arm as necessary to rest on the bracket
Slot
Bracket
Secure the bracket with a
Long
Screw
screw provided.
Bracket
Figure 9
6. Secure the outside air collar (item #4 in Figure
1) as shown in Figure 10.
Secure the outside air collar over the air gate using the four (4) long screws (provided) through the inside holes (indicated by arrows).
Outside Air Collar
Figure 10
7. Attach fl exible duct to the outside air collar
using two (2) short screws (provided), then wrap with duct tape as shown in Figure 11.
8. Duct Hole Framing: Cut or frame a hole through
the outside of the enclosure for the installation of the duct inlet hood. A 5" (127 mm) diameter hole is required. Feed the loose end of the fl exible duct through the hole cut for the inlet hood and attach to the collar on the inlet hood using two (2) short screws (provided), then wrap with duct tape. Insert the hood into the opening. Secure in place with nails driven through the holes in hood fl ange. Seal with noncombustible waterproof silicon type caulking. If additional duct is needed, use Class 0 metallic air duct (refer to Figure 12).
Note: The Class 0 metallic air duct can be routed out the back wall or side wall, up through the ceiling or fl oor joists to an outside wall. Check local building codes for any restrictions. We recommend that the inlet be at least four (4) feet above grade level.
CAUTION
Do not install the air inlet in the attic, garage, near combustible gases (i.e. paint, gasoline, etc.) or where there is a fuel burning appliance or where the opening could be blocked by snow, bushes or other obstacles.
4" (102 mm) Class 0 air duct
Hood
Secure the hood
to a vertical post
with the inlet posi-
Air Inlet
tioned downward.
• IN COLD CLIMATES THE AIR DUCT SHOULD BE INSULATED.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LHP reserves the right to make changes at any time, without notice, in design, materials, specifi ca­tions, prices and the discontinuance of colors, styles and products. Consult your local distributor for fi replace code information.
Printed in U.S.A. © LHP 2006
P/N 750,206M REV. NC 03/2006
2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 12