LEMET GREENLINE 50, GREENLINE 80, GREENLINE 120, GREENLINE 200, ECOWAY 100 Operation And Installation Manual

...
1
OPERATION AND INSTALLATION MANUAL
WALL-MOUNTED, UNVENTED ELECTRIC WATER HEATERS
LEMET GREENLINE 30, 50, 80, 100, 120 and 200 Liter (vertical and horizontal)
GREENLINE ECOWAY SMALL
2
Thank you for purchasing a Lemet electric water heater. An electric water heater is a device used to heat water and store that water in a heated state by means of electricity. It is the ideal solution for light commercial, industrial and domestic hot water requirements. Please read and understand this manual before commencing to install the unit and leave the manual with the user.
ECOWAY, GREENLINE and SMALL water heaters can be installed only with the use of muffs (domestic cold water inlet and domestic hot water outlet) facing downwards. They can work in a pressurized system with one or more domestic hot water intake points. The vertical mounting method is specified on the cover. The heater is highly insulated and can remain switched on at all times.
1. GENERAL WARNINGS
1. Installation must be undertaken by a competent, preferably certified, installer with knowledge in the installation of unvented electric water heaters. The manufacturer shall not be liable for damage resulting from incorrect installation or a failure to comply with this instruction manual. The assembly must be performed by qualified staff having appropriate permissions, and executed in accordance with the conditions contained in the manual. The installation must be confirmed in the warranty card.
2. Do not use the water heater when frozen. Wait until the water flows again in the water heater before using.
3. Do not attempt to repair, but call a certified installer. Failing to do so will void your warrantee.
4. The appliance may be used by children aged 8 and over and persons with reduced mental, physical or sensory capabilities or lack of experience and knowledge only when they are under supervision or they have been instructed on how to operate the heater safely and know the risks. Children must never play with the water heater nor must they clean the heater or service the water heater.
5. Always use the supplied pressure relief valve or a KIWA approved pressure relief valve. Failing to do so will restrict the proper functioning of your water heater and can potentially damage your water heater.
6. Failing to use the supplied pressure relief valve or a KIWA approved pressure relief valve will void your warrantee.
7. Always install a stopcock on mains water supply line for easy installation and servicing.
8. IMPORTANT: We strongly recommend to install a pressure reducing valve if the water pressure is too high (5 bar or more) or if you suffer from fluctuating water pressure. High water pressure and/or fluctuating water pressure often occur in apartment building, flats, farms, older houses and houses and buildings in elevated areas. Any damage caused by a too high water pressure or fluctuating water pressure will not be covered by the warrantee.
Pressure reducing valve
3
2.1 TECHNICAL DATA: ECOWAY
Picture 2.1
ECOWAY Electric water heaters
50L
80L
100L
Time of heating up to 65OC (Δt=45)
min.
80
125
160
Rated voltage
V/Hz
230/50
230/50
230/50
Electric heater power
W
2000
2000
2000
Maximum rated current
A
9,1
9,1
9,1
Temperature adjustment range
°C
20-75
20-75
20-75
Minimal/maximal rated temperature
°C
5/85
5/85
5/85
Maximum tank working pressure
Mpa
0,6
0,6
0,6
Connection port spacing
cm
10
10
10
Tank diameter/Total height
cm
44/56
44/80
44/93
Protection rating
IP
24
24
24
Net weight (without water)
kg
17
23
27
1. Domestic cold water inlet (BLUE marking)
G 1/2" W/F
2. Domestic hot water outlet (RED marking)
G 1/2" W/F
3. Casing
4. Casing driver with control panel
5. Cable with plug*
6. Pressure relief valve
7. Drain valve (install a discharge pipe underneath)
8. Stopcock on mains water supply line inlet 9. Stopcock on hot water outlet
10. Discharge pipe to drain of expansion water
4
2.2 TECHNICAL DATA: GREENLINE (Vertical and Horizontal)
Picture 2.2.1 Picture 2.2.2
1. Domestic cold water inlet (BLUE marking)
G 1/2" W/F
2. Domestic hot water outlet (RED marking)
G 1/2" W/F
3. Casing
4. Housing with signal lamp and temperature control
5. Cable with plug*
6. Pressure relief valve
7. Drain valve (install a discharge pipe underneath)
8. stopcock on the mains water supply line
9. Stopcock on hot water outlet
10. Discharge pipe to drain of expansion water
GREENLINE Electric water heaters
50L
60L
80L
100L
Time of heating up to 65OC (Δt=45)
min.
80
95
125
160
Rated voltage
V/Hz
230/50
230/50
230/50
230/50
Electric heater power
W
2000
2000
2000
2000
Maximal rated current
A
9,1
9,1
9,1
9,1
Temperature adjustment range - up to
°C
75
75
75
75
Minimal/Maximal rated temperature
°C
5/85
5/85
5/85
5/85
Maximum tank working pressure
Mpa
0,6
0,6
0,6
0,6
Connection port spacing
cm
10
10
10
10
Tank diameter/Total height
cm
44/56
44/63
44/80
44/93
Protection rating
IP
24
24
24
24
Net weight (without water)
kg
17
19
23
27
5
2.3 TECHNICAL DATA: SMALL
Picture 2.3
1. Domestic cold water inlet (BLUE marking)
G 1/2" W/F
2. Domestic hot water outlet (RED marking)
G 1/2" W/F
3. Casing
4. Signal lamp and temperature control
5. Cable with plug*
6. Pressure relief valve
7. Drain valve (install a discharge pipe underneath)
8. stopcock on the mains water supply line
9. Stopcock on hot water outlet
10. Under sink pressure version: Discharge pipe to drain of expansion water
10. Over sink non pressure version: three-way tap over sink
11, Under sink non pressure version: three-way tap under sink
6
Over sink
Type
10.5NE
10.10NE
Under sink
Type
10.5PE
10.1NE
Nominal capacity
L
5
10
Warm-up time (1500W**) to 65 °C (?t=45 °C)
min
11
23
Warm-up time (1200W**) to 65 °C (?t=45 °C)
min
13
27
Warm-up time (1000W**) to 65 °C (?t=45 °C)
min
26
37
Rated voltage
230/ 50 Hz
230/ 50 Hz
Maximum rated current
6,5A (1500kW**)
6,5A (1500kW**)
5,2A (1200W**) / 4,3A (1000W**)
Maximum working temperature and pressure
85 °C/ 6 bar
85 °C/ 6 bar
Temperature adjustment range
7-65
7-65
Height-width-depth
cm
42-25-22
44-29-26
Protection class
IP
24
24
Magnesium anode
Type
25 X 150
25 X 150
Net weight
kg
5
7
2.4 CONSTRUCTION The heater tank is made of sheet steel covered with ceramic coating, which constitutes a passive
corrosion protection. An additional corrosion protection is a magnesium anode. In the tank bottom there is a flange with a flanged lip fastened with bolts or a plug. A heater and a magnesium anode are installed in the flanged lip or in the plug. In the ECOWAY, GREENLINE models the insulation is made of polyurethane foam, whereas in the SMALL model with polystyrene.
Water is heated by an electric heater, which in the GREENLINE and SMALL models is controlled by a thermostat and in the ECOWAY model by means of an electronic controller. An overheat protection of water heated by the electric heating element is in this case a non-automatic temperature limiter, which disconnects the electric circuit when the water temperature rises too high. This limiter requires manual start in order to restart the heater. In the housing of the heating element control system there is a lamp signalling the operation of the electrical heating element.
Two connection muffs are lead from the housing; in the ECOWAY, GREENLINE and SMALL models, connection of cold water is marked with a blue band, and the outflow of hot water is marked with a red band.
3. INSTALLATION Overview
COMPONENTS CHECKLIST
Water heater
6 bar pressure relief valve ½”
Unassembled UK plug
General installation instructions
Installation must be undertaken by a competent, preferably certified, installer with knowledge
in the installation of unvented electric water heaters. The manufacturer shall not be liable for damage resulting from incorrect installation or a failure to comply with this instruction manual. The assembly must be performed by qualified staff having appropriate permissions, and executed in accordance with the conditions contained in the manual. The installation must be confirmed in the warranty card.
Make sure the stopcock on the mains water supply line is closed before commencing to install
the water heater