Current Transducer LA 100-P
For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
16019
Electrical data
IPN = 100 A
IPN Primary nominal current rms 100 A IPM Primary current, measuring range 0 .. ± 150 A RM Measuring resistance @ TA = 70°C TA = 85°C R
with ± 12 V @ ± 100 A @ ± 120 A with ± 15 V @ ± 100 A @ ± 150 A
ISN Secondary nominal current rms 50 mA KN Conversion ratio 1 : 2000 VC Supply voltage (± 5 %) ± 12 .. 15 V I
Current consumption 10 (@ ± 15 V) + IS mA
C
0 50 0 42
max
0 22 0 14
max
0 110 20 102
max
0 33 20 25
max
M min RM max RM min RM max
Accuracy - Dynamic performance data
X Accuracy @ IPN , TA = 25°C @ ± 15 V (± 5 %) ± 0.45 % @ ± 12 .. 15 V (± 5 %) ± 0.70 %
ε
Linearity error < 0.15 %
L
Typ Max IO Offset current @ IP = 0, TA = 25°C ± 0.10 mA IOM Magnetic offset current 1) @ IP = 0 and specied RM, after an overload of 3 x IPN ± 0.15 mA IOT Temperature variation of IO - 25°C .. + 85°C ± 0.05 ± 0.30 mA
- 40°C .. - 25°C ± 0.10 ± 0.50 mA tra Reaction time to 10 % of IPN step < 500 ns tr Response time 2) to 90 % of IPN step < 1 µs di/dt di/dt accurately followed > 200 A/µs BW Frequency bandwidth (- 1 dB) DC .. 200 kHz
General data
TA Ambient operating temperature - 40 .. + 85 °C TS Ambient storage temperature - 40 .. + 90 °C RS Secondary coil resistance @ TA = 70°C 120  @ TA = 85°C 128
m Mass 18 g
Standards 3) EN 50178: 1997
Features
effect
Advantages
Applications
Application domain
Notes: 1) Result of the coercive eld of the magnetic circuit
2)
090615/10
With a di/dt of 100 A/µs
3)
A list of corresponding tests is available.
LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com
Page 2
Current Transducer LA 100-P
dCp, dCI,
Rated isolation voltage
Nominal voltage
Single isolation
300 V
300 V
Reinforced isolation
150 V
150 V
Isolation characteristics
Vd Rms voltage for AC isolation test, 50 Hz, 1 min 2.5 kV
Impulse withstand voltage 1.2/50 µs 4.5 kV
V
w
Min dCp Creepage distance 3.8 mm dCI Clearance distance 3.8 mm CTI Comparative Tracking Index (group IIIa) 175
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
EN 50178 IEC 61010-1
V
w
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
090615/10
LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
Page 2/3
www.lem.com
Page 3
Dimensions LA 100-P (in mm. 1 mm = 0.0394 inch)
Front view
Connection
Secondary terminals
Terminal + : supply voltage +12 .. 15 V Terminal - : supply voltage -12 .. 15 V Terminal M : measure
Top view
Mechanical characteristics
0.63 x 0.56 mm Recommended PCB hole 0.9 mm
Left view
Remarks
I S is positive when IP ows in the direction of the arrow.
090615/10
LEM reserves the right to carry out modications on its transducers, in order to improve them, without prior notice.
Page 3/3
www.lem.com