Current Transducer HAS 50 ... 600-S
For the electronic measurement of currents: DC, AC, pulsed...,
= 50 ... 600 A
P N
with galvanic separation between the primary circuit and the secondary
circuit.
Electrical data
Type Primary nominal Primary current,
RMS current measuring range 1)
I
HAS 50-S 50 ±150
HAS 100-S 100 ±300
HAS 200-S 200 ±600
HAS 300-S 300 ±900
HAS 400-S 400 ±900
HAS 500-S 500 ±900
HAS 600-S 600 ±900
UC Supply voltage (±5 %) 1) ±15 V
I
R
U
R
Current consumption ±15 mA
C
Insulation resistance @ 500 V DC > 1000 MΩ
INS
Output voltage (Analog) @ ±I
out
Output internal resistance approx 100 Ω
out
RL Load resistance 2) > 1 kΩ
Accuracy - Dynamic performance data
ε
Total error @ I
tot
, TA = 25 °C (excluding oset) < ±1 % of I
P N
εL Linearity error 3) (0 ... ±I
U
Electrical oset voltage, TA = 25 °C < ±20 mV
O E
U
Hysteresis oset voltage @ IP = 0,
O M
after an excursion of 1 × I
TCU
Temperature coecient of U
O E
HAS 100 ... 600-S < ±1 mV/K
TCU
t
Temperature coecient of U
out
Delay time to 90 % of I
D 90
P N
BW Frequency bandwidth (−3 dB) 5) DC ... 50 kHz
General data
TA Ambient operating temperature −10 ... +80 °C
TS Ambient storage temperature −25 ... +80 °C
m Mass approx 60 g
Standards UL UL 508:2010
EMC IEC 61000-6-2:2016
IEC 61800-3:2017
Safety IEC 61010-1:2010
Environmental IEC 61477-1:2012
IEC 61800-2:2012
1)
Notes:
limited as the nominal. To measure the full dened measuring range, the
load resistor should be at minimum 10 kΩ
variation of the oset between 390 MHz and 400 MHz with a eld
intensity of 10 [V/m].
N° 74.74.25.000.0, N° 74.74.34.000.0, N° 74.74.44.000.0, N° 74.74.46.000.0, N° 74.74.48.000.0, N° 74.74.50.000.0, N° 74.74.52.000.0
15April2020/version 15
Operating at ±12 V ≤ UC < ±15 V will reduce the measuring range
2)
If the customer uses 1 kΩ of the load resistor, the primary current has to be
3)
Linearity data exclude the electrical oset
4)
For a di/dt = 50 A/µs
5)
Under small signals condition
6)
Regarding compliance towards IEC 61000-4-3 (IEC 61800-3:2017):
(A) I
P N
, RL = 10 kΩ, TA = 25 °C ±4 V
P N
) < ±1 % of I
P N
HAS 50-S < ±2 mV/K
O E
(% of reading) < ±0.1 %/K
out
(A)
P M
< ±20 mV
P N
4) < 3 µs
LEM reserves the right to carry out modications on its transducers,
in order to improve them, without prior notice
P N
P N
Features
● Hall eect measuring principle
● Insulating plastic case made of
polycarbonate PBT recognized
according to UL 94-V0.
Advantages
● Easy mounting
● Low power consumption
● Small size and space saving
● Only one design for wide current
ratings range
● High immunity to external
interference.
Applications
● AC variable speed drives
● Static converters for DC motor
drives
● Battery supplied applications
● Uninterruptible Power Supplies
(UPS)
● Switched Mode Power Supplies
(SMPS)
● Power supplies for welding
applications.
Application domain
6)
● Industrial.
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com
Page 1/3

Current Transducer HAS 50 ... 600-S
Insulation coordination
Ud RMS voltage for AC insulation test, 50 Hz, 1 min 3.6 kV
UNi Impulse withstand voltage 1.2/50 µs > 6.6 kV
Min
dCp Creepage distance 7.08 mm
dCI Clearance 6.23 mm
CTI Comparative tracking index (group IIIa) 275
Applications examples
According to IEC 61010-1 standard and following conditions:
● Over voltage category OV 3
● Pollution degree PD2
● Non-uniform eld
IEC 61010-1
, dCI, U
Cp
Ni
Nominal voltage
600 V
300 V
Safety
This transducer must be used in limited-energy secondary circuits according to
IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
15April2020/version 15
LEM reserves the right to carry out modications on its transducers,
in order to improve them, without prior notice
Page 2/3
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com

Dimensions HAS 50 ... 600-S (in mm)
Mechanical characteristics
● General tolerance ±0.5 mm
● Transducer fastening 1 hole ⌀ 4.5 mm
1 M4 steel screw
Recommended fastening torque 0.75 N·m (±10 %)
● Connection of secondary Molex type 2501P04V00A
: 1) Recommanded mating connector : Molex
511910400 (housing) and 508029101 (contact).
d
Cl
d
Cp
Connection
I
P
U
C
R
L
U
C
Remarks
● U
is positive when IP ows in the direction of the arrow.
out
● Temperature of the primary conductor should not exceed
100 °C.
● Installation of the transducer must be done unless
1)
otherwise specied on the datasheet, according to LEM
Transducer Generic Mounting Rules. Please refer to
LEM document N°ANE120504 available on our Web site:
https://www.lem.com/en/le/3137/download/.
● Dynamic performances (di/dt and delay time) are best
with a single bar completely lling the primary hole.
● This is a standard model. For dierent versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
15April2020/version 15
LEM reserves the right to carry out modications on its transducers,
in order to improve them, without prior notice
Page 3/3
LEM International SA
Chemin des Aulx 8
1228 PLAN-LES-OUATES Switzerland
www.lem.com