Refer to markings on the appliance for additional information
Please read entire manual before installing your new furnace. Failure to follow these instructions may
SAFETY NOTICE
Parts List
1. Furnace assy w/Jackets and top 110k unit has 20”x 20” standard 220k has 20”x 25” outlet
2. Jacket filler plate for flue outlet ( in Ship kit )
3. Flue outlet (110k has 6” 220K has 8”) w /gasket ( In ash pan)
4. Blank cover for flue outlet w/gasket ( In ash pan)
5. 16-1/4-20 x 1 bolts ( In ash pan)
6. Feeder Assy w/gaskets installed
7. 110kBTU furnace has a 200# hopper w/320# as option. 220kbtu comes standard with the
8. Blower w/ Coal Trol Thermostat and feeder motor(s) and convection blower(s)
9. High Limit
10. Ash Pan
11. Owner’s Manual ( in Ship kit )
12. Warranty Registration ( in Ship kit )
13. Firestop ring (s) ( in Ship kit )
14. Starter Bag(s) ( in Ship kit )
15. Flame Diffuser ( In ash pan)
BURN ANTHRACITE COAL ONLY
WARNING - Risk of Fire:- Do not operate with flue draft exceeding -.07 in. water column.
Operating at a number above -.07 can cause solid fuel devices to burn back into the hopper.
- Do on operate with fuel loading or ash removal doors open.
- Do not store fuel or other combustible material within marked installation clearances.
- Inspect and clean flues and chimney regularly.
320# hopper
Options
1. Filter box w/ filter
2. 320Lb hopper for AK110 standard on the AK220
3. Custom outlet sizes and shapes available for top
4. Custom inlet sizes and shapes available
5. Extra ash pan
6. Ash pan cover
Additional Info can be found by visiting https://www.leisurelinestoves.com/owners/videos/
DANGER - Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.
CAUTION - Hot Surfaces: - Keep children away. - Do not touch during operation.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
Please save these instructions
BURN ANTHRACITE COAL ONLY
WARNING - Risk of Fire:- Do not operate with flue draft exceeding -.07 in. water column.
Operating at a number above -.07 can cause solid fuel devices to burn back into the hopper.
- Do on operate with fuel loading or ash removal doors open.
- Do not store fuel or other combustible material within marked installation clearances.
- Inspect and clean flues and chimney regularly.
To ensure a safe installation, it is recommended that this furnace be installed by a qualified installer.
The sheet metal top and sides can be easily removed to reduce the chance of dents or scratches on the painted surfaces.
To remove the sheet metal, first lift off the top section. Now, the sides can be removed by lifting up and out away from the furnace
Place the furnace as close to the chimney as possible while still maintaining the proper clearances. No more than 10 feet of stovepipe should be used, including two or less 90° elbows. All horizontal runs of pipe should have a minimum 1/4 in. rise per foot. All stove pipe must be 24 gauge or thicker black or blued steel. Do not
use galvanized or Aluminum pipe! A properly sized barometric damper is also needed. 6” pipe for 110kbtu furnace and 8” pipe for 220kbtu furnace. Type HT (was Class A) / or masonry chimney required for exterior
pipe. If a liner is needed for a masonry chimney use an insulated or fill insulation. Should be made of Stainless Steel of at least 316 grade. It is a recommended to always check with local code for proper installation.
If no chimney is available a Powervent can be used (SWG5- AF ) for both 110kbtu and 220kbtu purchased from a Leisure Line Dealer make sure it is labeled for use with a Leisure Line Product. Instructions will be provided with the Powervent for install.
At least 16 inches (400 mm) in front and 8 inches (200 mm) on either side of the fuel-loading and ash-removal doors. Furnace is to be installed on non-combustible surface. Underneath the chimney connector and extending at least 2 inches (50 mm) on either side of the chimney connector. Non-combustible floor must extend to these dimensions as well.
After selecting the side for the flue, break out the perforated panel at the bottom of the jacket. Install the flue outlet and outlet blank off plate. Install the bottom jacket filler plate under the flue outlet. Re-install the sheet metal jacket by sliding the groove on the bottom of each side panel over the steel lip on the furnace. The gap around the flue outlet can be sealed with fiberglass gasketing such a rope or thick flat gasket. The top sheet metal piece holds the sides in place. Making sure the jacket insulation is properly in place.
Next install the feeder in the back of the unit, the grate(s) can be removed to make this process easier. Using the 4 bolts supplied, tighten just past snug about 80in/lbs. Next install the hopper placing the gasket(s) around hopper opening(s) of the feeder first. Use the ¼-20 bolts with the angle support.
Mount fan extension box to fan using ¼-20 bolts and nuts supplied . If you are installing the cold air return box assemble to the fan assembly now. Filter is removable by sliding it to the front or rear after removing holding tab, Select what side of the hopper you want the thermostat module mount it to the bottom of the hopper using supplied self drilling screws (The holes can be predrilled to make it easier. ) keeping it about 1.5”- 2 “ from back of furnace. Try to keep metal shavings from falling into module box. Feeder motor(s) and combustion blower(s) can be wired at this time using blue wire nuts supplied. Red wires are for feeder gear motor, Blue wires are for the combustion blowers. If you are wiring a 220kbtu the red w/white trace and blue w/white trace are for 2nd feeder Route the conduit neatly and out of the way. Next install the convection fan to the furnace
DANGER - Risk of Fire or Explosion - Do not burn garbage, gasoline, drain oil or other flammable liquids.
CAUTION - Hot Surfaces: - Keep children away. - Do not touch during operation.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
Please save these instructions
Loading...
+ 7 hidden pages