LEISTER ASO Medium Pressure Blower
Please read operating instructions carefully before use and keep for further reference.
GB
OPERATING INSTRUCTIONS
It is suitable for delivering air, non combustible, non corrosive and non
explosive gases.
• Air supply for LEISTER Hot Air tools, for intake air supply and for cooling.
• Ventilation of tanks, aquariums and different applications for textile ma-
chines.
• Drawing off of welding gases and fumes.
• Transfer of granular and loose materials.
• Vacuuming screen printing machines and air tables.
APPLICATION
®
LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland
Tel. +41 41 662 74 74 Fax + 41 41 662 74 16
www.leister.com sales@leister.com
2
Danger! When opening up the tool live connections are exposed. Therefore, before opening it, discon­nect all poles from the mains.
The tool must be grounded with the protective con­ductor.
The voltage rating stated on the tool should corre­spond to the mains voltage.
Protect tool from damp and wet.
Use thermal overload protection switch.
Pay attention to the direction of rotation.
230 400
Design Voltage for three-phase supply V~ Voltage for single phase supply V~ Condensor for single phase mF Capacity W Frequency Hz Air flow l/min. Static pressure Pa Noise level dB (A) Environmental protection DIN 40050 Diameter of air intake (external Ø) mm Diameter of air outlet (external Ø) mm Ambient temperature °C Weight kg Size (L x B x H) mm
radial blower
3 x 230 – 254 3 x 380 – 440
1 x 230 – 254
25
550
50 / 60
13500 / 15900
1600 / 2400
70
IP 54
134
90
<60
15,0
357 x 387 x 368
WARNING
CAUTION
TECHNICAL DATA
100 Pa = 1 mbar