Installation, Configuration, and Operation Instructions
END-TO-END Solutions for
Broadcast & Streaming
Page 2
Support
At LEIGHTRONIX, every customer of our standard product line
receives technical support at no extra charge. There are no service
contracts, no annual renewals, no allowances, no deductibles, and no
exclusions.
In addition to a 5 year hardware warranty, benets include access to:
• Priority toll-free telephone support
• Email support
• Online support, desktop to desktop via Webex®
• Software updates
• Firmware updates
• Assistance with updates
Looking for firmware/software or additional documentation? Go to
www.leightronix.com/support.html to download important updates
and full product manuals.
BACK PANEL ..................................................................................................................................4
SYSTEM INSTALLATION ................................................................................................................ 5
INSTALLING THE LABVAULT-HD ............................................................................................................................ 5
ENTERING NETWORK SETTINGS INTO LABVAULT-HD ...................................................................................... 8
ADMINISTRATIVE WEB INTERFACE .......................................................................................... 10
OPENING AND LOGGING IN ................................................................................................................................. 10
UNDERSTANDING STATUS INDICATORS ON “SYSTEM DASHBOARD” SCREEN ............................................11
Site Name and Location ................................................................................................................................... 12
LABvault-HD System Time ............................................................................................................................... 12
Usernames and Passwords for Administrative Interface .................................................................................. 13
Serial Port Setting ............................................................................................................................................. 14
SETTING UP FILE TRANSFER DESTINATION(S) ................................................................................................ 15
E-HD2 Server Destination ................................................................................................................................ 15
Server with FTP Capabilities ............................................................................................................................ 16
Record Settings ................................................................................................................................................ 17
Recording from the Web Interface .................................................................................................................... 18
PLAYING FILES ...................................................................................................................................................... 19
“MPEG Player” Left Column Controls ............................................................................................................... 19
Rename Files on Internal Hard Drive ............................................................................................................... 22
Delete Files from Hard Drive/Transfer Queue .................................................................................................. 22
Manually Transfer Recorded Files .................................................................................................................... 22
Change File Transfer Destinations ................................................................................................................... 22
Enable/Disable Auto Delete .............................................................................................................................. 22
Open a Log File ................................................................................................................................................ 23
Search a Log File ............................................................................................................................................. 23
Delete a Log File .............................................................................................................................................. 24
Page 4
MAINTAINING THE LABVAULT-HD........................................................................................................................ 25
Check Internal Hard Drive ................................................................................................................................ 25
Reboot/Shut Down ........................................................................................................................................... 25
CONTROL COMMANDS ............................................................................................................... 26
The LABvault-HD broadcast digital video encoder makes it simple to digitally record any video source
with the push of a button. Capture high-denition digital video les for use with a LEIGHTRONIX
E-HD2 server/controller and/or a FTP capable third party server or storage location. Use the included
administrative Web interface to operate your LABvault-HD record and transfer features from any
location and set up le transfer destinations, change recording quality presets, manage les on the
LABvault’s internal hard drive, and access the system’s log les.
ABOUT THIS MANUAL
This manual describes how to install your LABvault-HD as well as use the included LABvault-HD
Web interface to set up and control the player/recorder. Instructions on using a touch screen or other
external control system with the LABvault-HD should be obtained from the third party provider. Refer
to the “CONTROL COMMANDS” on page 26 of this manual for a list of the commands needed to
program your external control system.
PACKING LIST
(1) LABvault-HD Digital Video Player/Recorder
(1) Product Resource Disc, Including LABvault-HD Manual
(1) Part #10-0311, AC Power Cord, 6 ft.
(1) Part #10-4856, CAT 5e Ethernet Cable, 7 ft.
2018-08-07Page 1
Page 6
LABvault-HD
Important Safety Instructions
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers) that
produce heat.
9. Do not defeat the safety purpose of the grounding-type plug. A grounding-type plug has two blades and a third grounding
prong. The third prong is provided for your safety. If the provided plug does not t into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and the point
where they exit from the apparatus.
11. Only use attachments/accessories specied by the manufacturer.
12. Unplug this apparatus during lightning storms or when unused for long periods of time.
13. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. When the apparatus is turned off, certain components in the power supply and system board remain energized. In order to
remove all electrical power from the apparatus, unplug the power cord from the MAINS socket outlet.
To reduce the risk of electric shock, do not expose this apparatus to rain or moisture.
This apparatus must be connected to a MAINS socket outlet with a protective earthing
connection.
Page 22018-08-07
Page 7
LABvault-HD
Front Panel
FRONT PANEL
KEYPAD
The four LABvault-HD arrow keys are used to display status information as well as for the entry of TCP/IP network
addresses.If you hold down an arrow key for more than one second, it begins to scroll through all of the available
options. Release the key when the desired option is displayed.
The front panel keypad also turns the LABvault-HD on/off. Note that the
LABvault-HD automatically turns on when the unit is plugged in. When
held for four seconds, the red “X” button turns off the LABvault-HD. If the
LABvault-HD has been turned off, press the green check push button for
two seconds to turn the unit back on.
LEDS
The LABvault-HD front panel has two status, light-emitting diodes (LEDs) for at-a-glance feedback. The red “Record”
LED lights up when the LABvault-HD is encoding. The blue “Play” LED lights up when playback on the LABvault is
activated.
BEFORE unplugging or
removing power from the
LABvault-HD, shut down the
unit from its front panel.
DISPLAY
The LABvault-HD display shows status and password-protected TCP/IP address entry screens. Once the LABvault-HD
has been booted up, press the up or down arrows on the keypad to display the following status screens:
Serial Number & Firmware Version
06/13 10:30:00AM
094000 V1.1.11
Firmware Date
06/13 10:30:00AM
FW Blt:5/31/12
Build Number
06/13 10:30:00AM
Bld Num: 197
IP Address
06/13 10:30:00AM
10.9.0.16
LABvault-HD Identication
06/13 10:30:00AM
ID:LABvault-HD
Processor Temperature
06/13 10:30:00AM
Temp: 28°C
Recorder Status
06/13 10:30:00AM
Recorder Stopped
Player Status
06/13 10:30:00AM
MPEG Player Stop
Bios Date
06/13 10:30:00AM
Bios:02/20/10
PStat Firmware Version
Displays the rmware version for
the infrared remote control and
front panel status LEDs.
06/13 10:30:00AM
PStat Ver:4.10
Transfer Status
Indicates le transfer destination and
progress. If more than one destination is
selected for a transfer, the screen only shows
the rst destination to which the LABvault-HD
sends the le. Changes to “Send Idle” when
there are no active le transfers.
06/13 10:30:00AM
NX: 0.8591GB 2%
2018-08-07Page 3
Page 8
BACK PANEL
LABvault-HD
Back Panel
Not Used
A
The LABvault-HD back panel, includes, from left to right, top to bottom:
A: Power cord connector
B: 9-pin male RS-232 DTE connector for control by
a compatible third party system, such as a AMX or
Crestron touch screen
C: 1 RJ-45, 10/100/1000 BASE-T Ethernet port with
corresponding LED indicators
B
Not Used
D: 1 input tension clamp terminal block for analog
or AES digital audio recording
E: Audio output tension clamp terminal block for
analog or AES digital audio playback
F: 1 BNC video input connector for recording
G: 1 BNC video output connector for playback
C
DE
F
G
Page 42018-08-07
Page 9
LABvault-HD
System Installation
SYSTEM INSTALLATION
INSTALLING THE LABVAULT-HD
While installing the LABvault-HD, refer to the labeled back panel on page 4 that corresponds to your LABvault-HD.
Perform the following installation steps:
1. The LABvault-HD may be left as a standalone, tabletop unit or mounted into a rack as follows:
Leave empty rack spaces above and below the LABvault-HD. The LABvault-HD should not have
anything stacked on top of it.
a. Insert the LABvault-HD into the rack, aligning the holes of the unit’s mounting bracket with those of the rack.
b. Secure the LABvault-HD to the rack with user-supplied rack screws.
2. Connect the included power cable to the LABvault-HD’s power cord connector and then plug the other end into an
AC power source.
LEIGHTRONIX strongly recommends the use of an Uninterruptible Power Supply (UPS) with
the LABvault-HD. Damage from power loss or spikes is not covered under warranty.
3. Using a straight-through RJ-45 Ethernet cable, connect the LABvault-HD Ethernet port to a hub or switch on
your TCP/IP network. To check your network connection, look at the Ethernet LEDs above the Ethernet port and
compare to the the table on the bottom corresponding to your LABvault-HD’s back panel.
NOTE: The LABvault requires the following network
ports:
•23 Telnet
• 21 FTP Control Connection
• 20 FTP Data (if using third party FTP client in
passive mode)
• 80 for the LABvault-HD Web interface
• 2000 UDP for ePRO-BUS Control
LABvault-HD Ethernet LED Indicators
LED PositionStateDescription
RightOffConnection speed is 10Mb/s
GreenConnection speed is
OrangeConnection speed is
LeftSlow blinking
yellow
Fast blinking
yellow
100Mb/s
1000Mb/s
Ethernet link not established
Ethernet link established.
LABvault-HD is transmitting
on the network.
4. Connect your video signal wiring to the LABvault-HD as follows:
a. Video Source: this is the video resource or signal the LABvault-HD will record. Connect your video source
wiring to the LABvault-HD’s BNC video input.
b. Video Preview: preview your recorded video before it is transferred from the LABvault-HD by connecting a
monitor to the LABvault-HD’s BNC video output.
5. Your LABvault-HD audio connections are determined by the type of audio signals you wish to record and play out,
as described below:
• Embedded Digital Audio: part of your digital video signal, no additional audio connections are needed to play or
record this type of audio signal.
• Non-Embedded Audio Signals: the LABvault-HD supports two-channel analog and AES balanced digital audio
signals. The LABvault-HD server comes equipped with two audio terminal blocks for recording and playing your
non-embedded audio signals.
To play/record any of the LABvault-HD’s supported, non-embedded audio signals, connect your audio signal wiring
according to the following steps:
2018-08-07Page 5
Page 10
LABvault-HD
System Installation
NOTES:
a. Prepare your audio wiring for connection to the terminal
blocks by stripping approximately a 1/4 inch of shield
off the end of each wire. Twist each wire’s individual
strands together to prevent separation (see illustration
at right for example).
b. Perform the following steps for the LABvault-HD audio
record input and playback output:
i. With your ngers, gently grasp the desired terminal
block on the LABvault-HD’s rear panel and pull to
separate the block from the player/recorder.
ii. Secure each of your prepared audio wires in their
appropriate terminals as follows, referring to the table
below for each wire’s placement on the terminal block:
NOTE: The AES audio conguration uses only one of either common grounds.
• The illustrations for the following examples show the terminal blocks in vertical positions. When
connected to the rear panel, the blocks are horizontal with the AES terminals on each block
rotated toward the “SDI IN” BNC video input.
• The LABvault-HD supports an audio wiring gauge range of 18 (maximum) to 28 (minimum) AWG.
Terminal Block Wiring Congurations and Examples
AES
Terminal Block Conguration
Example of Wire Prepared for a LABvault-HD Terminal Block
Two-Channel Analog
Terminal Block Conguration
Terminals
Page 62018-08-07
Page 11
LABvault-HD
System Installation
(1) Using a slotted, pocket clip screwdriver with a
maximum tip width of 2.5mm and thickness
of .4mm, open the terminal’s tension clamp
by inserting the screwdriver tip into the
clamp’s corresponding tension release
slot (see the illustration on the right for an
example). Firmly push the screwdriver into
the slot until the clamp in the bottom of the
terminal slides open (refer to the illustration
Screwdriver Inserted into Tension Clamp Release Slot
Tension Clamp Release Slot Highlighted on a LABvault-HD
Terminal Block
Tension Clamp
Release Slot
Terminal
Tension Clamp
below).
(2) Insert the audio wire into its corresponding terminal until it is touches the bottom.
(3) While holding the wire in place, pull the screwdriver from the slot. The wire should now be clamped into
place and should not fall out of the terminal if gently tugged.
(4) Repeat steps 5.b.ii(1)–(3) for each of the remaining terminals in your audio terminal block conguration.
iii. Push each wired terminal block back into its slot on the rear panel of the LABvault-HD. The block only ts
one way into its holder on the rear panel
2018-08-07Page 7
Page 12
ENTERING NETWORK SETTINGS INTO LABVAULT-HD
LABvault-HD
System Installation
1. Power up the LABvault-HD by pressing the green check button on the
front panel for at least two seconds.
2. From the front panel, enter your password by pressing the right arrow
Default Front Panel Password:
ve right arrow keys
button to display the password entry screen and then your ve arrow key
password. If the password is entered correctly, the LABvault-HD’s conguration menu will be displayed (see below).
CONFIG MENU
Edit unit address
If the password is entered incorrectly, the front panel display returns to the status screens.
3. Either enter your LABvault-HD network addresses manually or use DHCP to automatically congure the addresses
according to the following steps:
• Automatic Network Addressing: enable DHCP on your LABvault-HD according to the table below. When enabled,
DHCP will congure your LABvault with an IP, subnet mask, and gateway network addresses.
i. From the “CONFIG MENU” screen, press “↑” or “↓” to pro-
ceed to the “Edit DHCP” screen.
CONFIG MENU
Edit DHCP
ii. Press “→” to select the screen.
iii. Press “↑” or “↓” to toggle the eld value from “DISABLED”
to “ENABLED.”
iv. Press “→” to enter the next screen.
ENABLE DHCP:
ENABLED
v. Either press “→” again to save your changes or “←” to
abort changes.
Press ~ to
confirm DHCP
The LABvault-HD must be powered down and then powered back up to apply any DHCP changes
(press the red “X” button for four seconds to turn the unit off and then press the green check
button for two seconds to return power).
• Manual Network Address Entry
Obtain an IP address, subnet mask, and a gateway for your LABvault-HD from your network administrator.
Repeat the network conguration steps below to enter your IP, subnet, and gateway network addresses.
i. From the “CONFIG MENU” screen, press “↑” or “↓” to pro-
ceed to the desired address screen.
ii. Press “→” to select the screen.
CONFIG MENU
Edit unit address
iii. Press “→” or “←” to position the underscore beneath the
editable elds and press “↑“ or “↓“ to edit the values.
iv. Press “→” past all of the editable elds to enter the next
Enter address
255. 0. 0. 0.
screen.
v. Either press “→” again to save your changes or “←” to
abort changes.
Press ~ to
confirm address
The LABvault-HD must be powered down and then powered back up to apply any network address
changes (press the red “X” button for four seconds to turn the unit off and then press the green
check button for two seconds to return power).
Page 82018-08-07
Page 13
LABvault-HD
System Installation
4. Optional: the LABvault-HD FTP buffer size setting helps to control the rate at which data is transferred to and from
the LABvault.The buffer size defaults to 16 kilobytes, but may be adjusted down to 4 KB or up to 64 KB. If your
network equipment can handle a higher rate, edit the setting to 32 or 64 KB for faster transfer times.
To change the FTP buffer size, perform the following:
i. From the “CONFIG MENU” screen, press “↑” or “↓” to
proceed to the “Edit FTP TCP Buf” screen.
ii. Press “→” to select the screen.
CONFIG MENU
Edit FTP TCP Buf
iii. Press “→” or “←” to position the underscore beneath the
editable elds and press “↑” or “↓” to edit the values.
iv. Press “→” again to apply change and enter reboot
TCP Buf size:
64 kbytes
message screen or “←” to abort changes.
The LABvault-HD must be powered down and then powered back up to apply any FTP buffer size
changes (press the red “X” button for four seconds to turn the unit off and then press the green
check button for two seconds to return power).
2018-08-07Page 9
Page 14
LABvault-HD
Administrative Web Interface
ADMINISTRATIVE WEB INTERFACE
Your LABvault-HD includes an administrative Web interface, allowing any authorized user to
conveniently set up and check on your LABvault from the Internet. The LABvault-HD administrative
Web interface has been tested for compatibility with Internet Explorer, version 8 or higher, Firefox,
Safari, and Google Chrome.
OPENING AND LOGGING IN
Type your LABvault-HD’s IP address into your Web brower’s address bar (i.e., http://10.255.14.175). Enter the LABvaultHD “admin” username and password into the login prompt and click the “Login” button.
NOTE: The username is always “admin” and the factory-default password is the last six digits of your LABvault-HD’s
serial number.
Administrative Interface Login Screen
Page 102018-08-07
Page 15
LABvault-HD
Administrative Web Interface
UNDERSTANDING STATUS INDICATORS ON “SYSTEM DASHBOARD” SCREEN
Click the “Dashboard” button to display the “System Dashboard” screen. The Dashboard displays all of the currently
congured settings for your LABvault-HD as well as the unit’s operational and storage status.
“System Dashboard” Web Interface Screen
MPEG Player Status: shows the
lename and playback time of the video
currently being displayed
Storage: shows the storage capacity of your
LABvault-HD’s internal hard drive for both
system conguration information (“System”)
and digital video les (“Internal”). Both the
“System” and “Internal” indicators show how
much storage has been used and is currently
available for each internal drive partition. The
“Internal” storage indicator also shows how
many les are currently on the hard drive.
Site Information: customize the “Site Name”
and “Site Location” information for your system
from the “Site Information” tab on the “System
Management” screen. Refer to the “Edit
Site Name and Location from the ‘System
Management’ Screen” subsection on the
following page for further information.
File Transfers: shows which les
are currently being transferred, the transfer
destination(s), and the transfer rate.
MPEG Recorder Status: shows
the user-selected lename and recording
quality preset for the current recording
session as well as the record time in
hours:minutes:seconds:frames. The
“Auto Delete” eld indicates whether or
not your LABvault-HD has been set up to
automatically delete transferred les from its
internal hard drive.
Destination Conguration: indicates
the le destination(s) set up for automatic/
manual le transfers and network settings
entered for all destinations.
Network Settings: shows the network
settings entered into your LABvault-HD’s
front panel.
2018-08-07Page 11
Page 16
LABvault-HD
Administrative Web Interface
ENTERING LABVAULT-HD SETTINGS
Congure your LABvault-HD’s site identication, system time and time zone, login username(s) and password(s), and
more from the “System Management” screen as described in the following subsections:
Site Name and Location
Customize the “Site Name” and “Site Location” on your
“System Dashboard” screen for your system. Click the
“SYSTEM” button to display the “System Management”
screen and then click the “Site Information” tab. Enter
a new identication name for your site into the “Site
Name” eld and a location description in the “Site
Location” eld. Click “Apply Changes” to change the
information on your “System Dashboard” screen.
“Site Information” Tab on “System Management” Web Interface Screen
“Site Information” Window on “System Dashboard” Screen
LABvault-HD System Time
Click the “SYSTEM” button to display the “System Management” screen and then click the “Site Information” tab.
“LABvault-HD Time” shows the date and time currently on your LABvault-HD system. To change the LABvault-HD’s
date/time, perform one of the following:
• Sync your LABvault-HD system’s date and time to your computer’s current date and time by clicking the “Set”
button next to the “Computer Time” eld.
• Manually change the LABvault-HD system date and time by editing the “Manual” elds as follows:
1. Use the up/down arrows to adjust the time elds.
2. Click on the date eld and select a new date in the calendar that appears.
3. Click the “Set” button to make the changes.
Page 122018-08-07
Page 17
LABvault-HD
Administrative Web Interface
Usernames and Passwords for Administrative Interface
Control access to your LABvault-HD system settings and operation through the browser-based interface. Click the
“SYSTEM” button to display the “System Management” screen and then click the “Security” tab. Perform the following:
“Security” Tab on “System Management” Web Interface Screen
• “System User (admin)” Password: use these elds to change the password for the “admin” user account. The
“admin” user is able to access the main LABvault-HD browser-based interface to change system conguration
settings, activate the LABvault-HD recorder, modify le transfer settings, and view system log les. To change the
“admin” password, enter up to eight alphanumeric characters in both elds and then click the “Change Password”
button to save.
• “Front Panel Password”: protect access to the network settings entered into the front panel of your LABvault-
HD by clicking a combination of ve arrow buttons and then clicking the “Save” button to change the password or
“Clear” to remove your entry from the eld.
• “Remote Users”:remote user accounts allow users with supported third party systems to initiate, stop, and check
the status of recording on your LABvault-HD. Enter a username and password into the corresponding elds and
then click the “Submit” button to add the account. To delete a remote user account, single click on the user’s name
and then click the “Delete” button.
2018-08-07Page 13
Page 18
LABvault-HD
Administrative Web Interface
ePRO-BUS Setting
Click the “SYSTEM” button to display the “System Management” screen and then click the “ePRO-BUS” tab. Click the
“Enable” button to allow the LABvault-HD to receive PRO-BUS control commands over your Ethernet network from a
LEIGHTRONIX E-HD2 server. Clicking “Disable” will prevent the LABvault-HD from receiving ePRO-BUS commands.
NOTE: Any LABvault-HD and E-HD2 server using the ePRO-BUS feature must be assigned a static IP address and
made available for UDP on Port 2000.
“ePRO-BUS” Tab on “System Management” Web Interface Screen
Serial Port Setting
The serial port mode setting, accessed by clicking the “Serial Port” tab on the “System Management” screen, applies to
the bottom serial port on the back panel of the LABvault-HD chassis. “Host” mode allows the LABvault-HD to receive
serial control commands from supported, external devices connected to the bottom serial port. “Camera” mode is not
currently supported. Currently, the LABvault-HD is automatically congured in the “Host” mode.
“Serial Port” Tab on “System Management” Web Interface Screen
Page 142018-08-07
Page 19
LABvault-HD
Administrative Web Interface
SETTING UP FILE TRANSFER DESTINATION(S)
Easily control where your recorded les are sent by clicking the “Destinations” button and using the “File
Destinations” screen tabs. Recorded les may be automatically or manually transferred to an E-HD2 server/
controller and/or third party server with FTP capabilities, as outlined below. The settings apply to each
recording session until you change them.
NOTE: If no destinations are enabled, the LABvault-HD will record and store your les on its internal 250 GB
hard drive. Refer to “Managing Files” on page 21 for instructions on transferring and deleting les
off the internal hard drive.
E-HD2 Server Destination
Send your LABvault-HD les to any of the storage volumes attached to your E-HD2 server. Enter your E-HD2’s IP
address, username, and password along with the name of the volume that you want to store the les. The names of
your storage volumes can be viewed in the WinLGX “Storage Manager” window. Complete the remaining settings
according to the labeled illustration below and click the “Apply Changes” button when you have nished.
“E-HD2” Tab on “File Destinations” Web Interface Screen
1
2
3
1
“Enable”: when checked, les will be automatically
transferred to the specied E-HD2 system after each
recording session.
2
“Verify Connectivity”: after entering your E-HD2 unit’s
IP address, username, and password, click the “Verify
Connectivity” button to ensure your LABvault-HD can
connect to the server.
LABvault will transfer les to your E-HD2 system. Single
click each hour segment on the timeline to toggle transfer
capabilities on or off (green = on, red = off).
4
“Enable Auto-Play CH”: if you have selected the “PEGcasting”
option on the “Record Settings” tab, you may choose to have the
transferring le stream automatically begin playing on your E-HD2
system’s Digital Video Player 1 and/or 2. Select a “Playback
Delay” of 2-60 minutes to specify how long after the le stream is
transferred that it should begin playing on the selected channel(s).
2018-08-07Page 15
Page 20
LABvault-HD
Administrative Web Interface
Server with FTP Capabilities
Push your les to another LEIGHTRONIX or third party video server with FTP capabilities. Enter your server’s IP
address, username, and password along with the name of the destination path. Complete the remaining settings
according to the labeled illustration below and click the “Apply Changes” button when you have nished.
“FTP Server” Tab on “File Destinations” Web Interface Screen
1
2
3
1
“Enable”: whenchecked, les will be automatically transferred
to the specied FTP server after each recording session.
2
“Verify Connectivity”: after entering your FTP server’s IP address,
username, and password, click the “Verify Connectivity” button to
ensure your LABvault-HD can connect to the server.
3
“Transfer Holdoff Schedule”: 24-hour timelineallows you to decide
which hours of the day your LABvault will transfer les to your server.
Single click each hour segment on the timeline to toggle transfer
capabilities on or off (green = on, red = off).
Page 162018-08-07
Page 21
LABvault-HD
Administrative Web Interface
RECORDING
Set up your LABvault-HD system for recording with the administrative interface’s record quality and automation settings
and then learn how to use the interface to activate the LABvault-HD’s record features through the following subsections:
Record Settings
Click the “DESTINATIONS” button and then select the “Record Settings” tab. Enter the following record settings and
then click the “Apply Changes” button to send the changes to your LABvault-HD or “Cancel” to abort. The settings will
be applied to every recording session until they are changed.
“Record Settings” on “File Destinations” Screen
• “File Name”: in the “File Name” eld, enter up to 14 characters (letters, numbers, and underscores only—no
spaces). If you use the same lename for more than one recording session, the record date and start time will be
appended to the name of each additional recorded le as “yy/mm/dd-hh/mm/ss” (year/month/day-hours/minutes/
seconds).
NOTE: Alternatively, you may enter the new lename into the “File Name” box in the lefthand column of the
LABvault-HD Web interface. Click the “Save” button to make the change. The new name will appear in
the “File Name” eld on the “File Settings” tab.
• “Create Unique Files”: when this option is selected, the record date and start time will be appended to the lename
of each recorded le as “yy/mm/dd-hh/mm/ss” (year/month/day-hours/minutes/seconds).
• “Automatic Delete”: if you want your recorded les deleted from the LABvault’s internal hard drive after each
transfer, select the “Enable” “Automatic Delete” option. The “Disable” option will cause your recorded les to stay
on the hard drive until you manually delete them from the “File Management” screen (click the “Files” button).
NOTE: If no destinations are enabled, the LABvault-HD will record and store your les on its internal 250 GB hard
drive. Refer to “Managing Files” on page 21 for instructions on transferring and deleting les off the
internal hard drive.
• “File Quality”: select a “File Quality” recording preset for your les. Each recording quality preset represents the
range of bit rates within which the le will be recorded.
• “Audio Source”: select the type of embedded or non-embedded (“Analog” or “AES”) audio signal your system is set
up to record from the options below.
¾ “Analog”: corresponds to the analog terminals on the LABvault-HD’s audio input terminal block
2018-08-07Page 17
Page 22
LABvault-HD
Administrative Web Interface
¾ “AES”: corresponds to the AES terminals on the LABvault-HD’s audio input terminal block¾ “Embedded 1-2”, “Embedded 3-4,” “Embedded 5-6,” and “Embedded 7-8”: if your audio is embedded within the
incoming video signal, select the embedded audio channel pair that you want to record
• “Closed Captions”: Select the “Enable Closed Captions” option to capture any closed caption data from the source.
Closed captions are hidden in the video signal and decoded for display on televisions with built-in decoders or
televisions connected to external decoders.
• “PEGcasting”: if you want your LABvault-HD les transferred to your E-HD2 server 15 seconds after the les
begin recording, select the “Enable” “PEGcasting” option. To use the PEGcasting Next to Live autoplay feature for
simulated live broadcasting, you must still complete the “PEGcasting N2L” conguration settings on the “E-HD2”
tab.
Left Column
“MPEG Recorder” Controls
Recording from the Web Interface
Start/Stop recording from the LABvault-HD Web interface as follows:
1. From the “MPEG Recorder” panel under the menu buttons or from the “MPEG
Engine Control” panel on the bottom of the “File Management” screen, click
the record button to begin recording.
2. To end the recording session, click the stop recording button . If a le
destination was congured and enabled in the Web interface, your recorded
le will be automatically transferred to the destination.
“MPEG Engine Control” Panel
Stop Button
Record Button
Page 182018-08-07
Page 23
LABvault-HD
Administrative Web Interface
PLAYING FILES
Playback of your recorded les on a connected preview monitor may be initiated from the LABvault-HD web interface as
well as a third party touch screen. To initiate playback of a le from the web interface, use one of the following control
options:
“MPEG Player” Left Column Controls
Left Column
“MPEG Player” Controls
On the left sidebar of the LABvault-HD web interface, you will see the control buttons for
the LABvault-HD’s MPEG player. Perform the following:
1. Click the load button to display the “Open File” popup window. Single click to select
the le you wish to display and click “Open” to load the selection or “Cancel” to
abort.
“Open File” Popup Window
Load Button
Stop Button
Pause Button
Play Button
2. Start playing the le by clicking the play button.
3. You may pause playback by clicking the pause button or stop it completely with the button. The stop button also
unloads the le from the MPEG player.
2018-08-07Page 19
Page 24
LABvault-HD
Administrative Web Interface
“MPEG Engine Control” Panel
The LABvault-HD’s MPEG player controls are also available on the bottom of the “FILES”/”File Management” screen
in the “MPEG Engine Control” panel. The “MPEG Engine Control” panel playback controls mirror the functionality of
the “MPEG Player” left column controls, so that controls from either panel can be used interchangeably during each
playback session. If a le is playing or paused, its lename will have the corresponding symbol next to it in the lefthand
“File Management” listing. Perform the following:
1. Click the “FILES” menu button to display the “File Management” screen.
“MPEG Engine Control” Panel on “File Management” Screen
Files on the
LABvault-HD’s
Internal Hard
Drive
Currently
Playing File
Stop Button
“MPEG Engine
Control” Panel
Pause Button
Play Button
2. From the lefthand listing of les on the LABvault-HD’s internal hard drive, single click to select the le you wish to
display.
3. From the “MPEG Engine Control” panel, start playing the le by clicking the play button.
4. You may pause playback by clicking the pause button or stop it completely with the stop button. The stop button
also unloads the le from the MPEG player.
Page 202018-08-07
Page 25
LABvault-HD
Administrative Web Interface
MANAGING FILES
The “File Management” screen displays a recorded le listing and transfer queue, allowing you to manually transfer les,
stop le transfers, and manage any les stored on the LABvault-HD’s internal hard drive. Recorded les are stored on
the LABvault’s internal hard drive if the “Automatic Delete” record le setting has been disabled and/or no le destinations
have been enabled, giving you the option to rename, delete, and manually transfer les from the “File Management”
screen. Click the “Files” menu button to display the screen and then perform any of the following steps, as needed:
“File Management” Web Interface Screen
Files on the
LABvault-HD’s
Internal Hard
Drive
File Transfer Queue
2018-08-07Page 21
Page 26
LABvault-HD
Administrative Web Interface
Rename Files on Internal Hard Drive
Under the “Video Files” listing on the left side of the screen, either single click on the le you would like to rename and
then click the “Rename” button or just right click on the le and select “Rename” from the menu that appears. In the
“Rename File” window that appears, enter a new lename of up to 27 alphanumeric characters, no spaces, and click
“Ok” to accept the change or “Cancel” to abort.
Delete Files from Hard Drive/Transfer Queue
• Hard Drive: under the “Video Files” listing, either single click on the le you would like to delete and then click
the “Delete” button or just right click on the le and select “Delete File” from the pop-up menu. Click “Yes” when
prompted to delete the le or “No” to abort.
• Transfer Queue: to delete a single le under “Video Transfers,” either single click on the le you would like to
delete and then click the “Remove” button or just right click on the le and select “Remove Transfer” from the
pop-up menu. To remove all les from the transfer catalog, either single click on a le and then click the “Remove
All” button or just right click on the le and select “Remove All Transfers” from the pop-up menu. Click “Yes” when
prompted to delete the le(s) or “No” to abort.
Manually Transfer Recorded Files
Under the “Video Files” listing, either single click on the le you would like to transfer and click the “Add” button to
transfer the le to your congured destination(s) or right click on the le and select a le transfer destination(s) from
the pop-up menu. Ensure you have entered the conguration settings for the selected destination(s) on the “File
Destinations” screen.
Popup Menu for “Video Files” Listing on the “File Management” Screen
Change File Transfer Destinations
Change the destination of any le in the “Video Transfers” queue by right clicking on the le and selecting one of the
add/remove options in the popup menu. The remove options de-select current le transfer destinations, while the add
options transfer the le to the corresponding destinations. Ensure you have entered the conguration settings for the
selected destination(s) on the “File Destinations” screen.
Popup Menu for “Video Transfers” Listing on the “File Management” Screen
Enable/Disable Auto Delete
Use the “Toggle Auto Delete” option to turn “Delete” on and off for the selected le.
Page 222018-08-07
Page 27
LABvault-HD
Administrative Web Interface
CHECKING LOG FILES
The LABvault-HD keeps track of everything done to or by it in internal log les which are accessible from the
administrative Web interface. Click the “LOGS” menu button to display the list of current LABvault-HD logs on the “Log
Files” screen.
“EVENTS.LOG” Selected on “Log Files” Web Interface Screen
Open a Log File
From the top panel on the “Log Files” screen, single click on the desired log le to select it and then click the “Save”
button to display an open/save le dialog box. Either open or save the selected log le on your computer or network as
a .txt or Excel® le.
Search a Log File
Search for specic entries within either of the event or rmware logs. From the top panel on the “Log Files” screen,
single click the desired log le. Enter your search term into the “Find” box and click the “Search” button to lter out any
entries not containing the search term. Use the “Previous” and “Next” buttons to move up and down between entries in
2018-08-07Page 23
Page 28
LABvault-HD
Administrative Web Interface
the log le.
Delete a Log File
From the top panel on the “Log Files” screen, single click the desired log le to select it and then click the “Delete”
button. A popup box will appear, asking whether or not you wish to delete the le. Click “Yes” to delete or “No” to abort.
The types of LABvault-HD log les are as follows:
• Event Logs: the event logs track LABvault-HD operations, including recording sessions, le transfers, and
LABvault status. Single click either “EVENTS.LOG” to select the most current le of LABvault-HD actions or
“OLDEVNTS.LOG” to view archived LABvault actions.When selected, both event logs display the screen shown in
the illustration above. The event logs provide a description of each action under “Message,” along with the action’s
date and time, severity, and type (“Source”).
The LABvault will continually write to the “EVENTS.LOG” le until it reaches 7 MB. Once “EVENTS.LOG” reaches
7 MB, the LABvault-HD will rename it to “OLDEVNTS.LOG” (deleting the previous “OLDEVNTS.LOG”) and then
display a new “EVENTS.LOG” on the “Log Files” screen. This ongoing cycle ensures that recent events are always
logged.
• Firmware Logs: the LABvault-HD creates log les that specically track rmware installations. The “pkgsrch.
log” le veries whether the LABvault-HD rmware le has been uploaded onto your LABvault, while the
“lvhdxxxxxx_full.log” records information about the actual installation of rmware on the LABvault. Separate
“pkgsrch.log” and “lvhdxxxxxx_full.log” rmware log les are created each time you perform a LABvault-HD rmware
update. Previous rmware log les are not overwritten when new rmware updates are performed.
• Disk Diagnostics Logs:the “scan_C.log” and “scan_D.log” les display information from the most recent
LABvault-HD hard drive scan performed with the “Disk Diagnostics” utility. Both les are automatically overwritten
each time you run a drive scan, with “scan_C.log” providing information about the system data partition on the drive
and “scan_D.log” covering the drive’s le partition area.
Page 242018-08-07
Page 29
LABvault-HD
Administrative Web Interface
MAINTAINING THE LABVAULT-HD
The administrative interface provides a “Maintenance” tab screen under “System Management” to help you easily keep
your LABvault-HD at peak performance. Take advantage of the no-charge rmware le updates to ensure your LABvaultHD system has the latest features and enhancements. Also, safeguard any recorded les and data on your LABvault-
HD’s internal hard drive by regularly running the disk diagnostics utility with the click of a button. Refer to the subsections
below for more details.
“Maintenance” Tab on “System Management” Web Interface Screen
Update Firmware
LEIGHTRONIX places the most current LABvault-HD rmware les on the LEIGHTRONIX Support Center Web
site. Save the update les to an accessible directory on your computer or network.
Once you have downloaded the LABvault-HD rmware update le from the Support Center, open the LABvault’s Web
interface and click the “SYSTEM” menu button. Select the “Maintenance” tab and use the “Choose File” button to
navigate to the saved location of the rmware le. Click the “Update” button to download and install the rmware le
onto your LABvault-HD.
Check Internal Hard Drive
The LABvault-HD disk diagnostics feature automatically xes many common File Allocation Table (FAT) errors that may
impair or cause data loss on your LABvault’s internal hard drive. LEIGHTRONIX recommends using the feature on a
monthly basis to ensure optimal drive performance as well as any time you discover le/drive errors in your log les or
notice drive performance issues due to improper system shutdown or rmware changes.
NOTE: The disk diagnostics process does not x physical degradation of the hard drive. Contact LEIGHTRONIX
Technical Support for further information on servicing your LABvault’s internal hard drive.
To run the disk diagnostics feature, click the “SYSTEM” button to display the “System Management” screen and then
click the “Maintenance” tab. Click the “Disk Diagnostics” button and then select the popup menu’s “Yes” option to
perform the disk check process. When the diagnosis has been completed, a log le describing any errors discovered
and actions performed will be added to the “Log Files” page on your LABvault’s Web interface.
Reboot/Shut Down
Click the “SYSTEM” button to display the “System Management” screen and then click the “Maintenance” tab. Click
“Reboot” to power your LABvault-HD off and then back on or click the “Shutdown” button to only power off your
LABvault.
2018-08-07Page 25
Page 30
LABvault-HD
Control Commands
CONTROL COMMANDS
The LABvault-HD is meant to be locally operated from a compatible, third party control system
connected either directly to the LABvault via an RS-232 serial cable or through your network. This
section provides the control commands needed to program your touch screen to operate your
LABvault-HD. For even greater versatility, your programmer can create a Web interface for Internet
Explorer that duplicates your touch screen interface.
Touch Screen Interface: RS-232 SERIAL or TELNET
NOTES:
• Serial communication is 115200, N, 8, 1.
• The remote control port is standard RS-232 DTE (connection to a standard PC DB-9 would
be via DB9F to DB9F NULL cable).
• Telnet has a 5 minute session timeout after no activity. Serial connections do not have a
timeout.
• A LABvault-HD with a serially connected external control system will boot logged in. A
LABvault-HD with an external control system connected via Telnet requires the user to log in
again on a reboot.
• When logged in, the prompt is: “LABVAULTHD>” and when not logged in, the prompt is: “>”
• Multiple Telnet sessions and a serial session are independent of each other.
• All commands and responses are terminated with <CR><LF>.
• The destination server for the FINALIZE command is congured via the LABvault-HD Web
interface.
LABvault-HD Control Commands
FUNCTIONCOMMANDDETAILSASCII RESPONSE
(Username) LoginUSER <USERNAME>Logs in username. Allows
access to restricted
function. Followed by PASS
command to complete
login. If followed by ANY
argument, it will appear to
be successful (as to not give
away which user accounts
are and are not valid).
331 User name ok, need
password
(Password) LoginPASS <PASSWORD>Species password after
“USER” command has been
completed.
Page 262018-08-07
• If successful: 230 User
Logged in, proceed
• If already logged in: 335
Already logged in
• If not preceded by
successful USER attempt:
332 USER account not
specied
• If invalid password or
user entered (user will
be required to re-execute
USER command): 507 Login
attempt FAILED
Page 31
FUNCTIONCOMMANDDETAILSASCII RESPONSE
LogoutLOGOFFLogs off the user and ends
the session. Restores
336 Session reset, rights reset
to guest privileges
default user guest rights.
Show PromptPROMPTONTurns on the “LABVAULT>”
200 Command OK
prompt.
Hide PromptPROMPTOFFTurns off the “LABVAULT>”
200 Command OK
prompt.
Play
NOTE: When
playback is
initiated, recording
will be stopped.
PLAYFILE <FILENAME>FILENAME is full lename/
ext of le to be played.
Filename is case insensitive.
\Internal\mpeg\ directory is
assumed.
200 Command OK
Ex.: PLAYFILE BROOKS.
M2T
Record
NOTE: When
recording is
initiated, playback
will be stopped.
RECFILE <FILENAME>Time/Date stamp will be
appended if same lename
is used for multiple records.
Do not include “.m2t” le
extension at the end of
lename. \Internal\mpeg\
200 Command OK
directory is assumed.
(Alphanumeric, ‘-’, ‘_’
allowed)
Ex.: RECFILE BROOKS
NOTE: Record le
parameters are set in
the LABvault-HD’s Web
interface
Pause PlayPAUSEPauses channel if it is in
200 Command OK
play, unpauses it if it is in
pause (toggle).
StopSTOPStops the current playback
200 Command OK
or record function.
Send FileFINALIZE <FILENAME>FILENAME is full lename/
ext of le to be nalized.
Filename is case insensitive.
\Internal\mpeg\ directory is
assumed. File will no longer
• If successful: 200
Command OK
• If unsuccessful: 663 Cannot
nalize le, no destinations
are enabled
be available for playback.
NOTE: For nalize to
succeed, at least one
destination must be
congured and enabled
via the LABvault-HD Web
interface, otherwise the
result will be fail.
Ex.: FINALIZE BROOKS.
M2T
LABvault-HD
Control Commands
2018-08-07Page 27
Page 32
LABvault-HD
Control Commands
FUNCTIONCOMMANDDETAILSASCII RESPONSE
Get File DirGETMPEGDIRGets the directory of the \
Internal\mpeg\ dir.
Ex.: 399 * 20683495 06-162009 14:32:30 00:00:30:07
BROOKS.m2t
In no event shall LEIGHTRONIX be liable for any damages whatsoever resulting from loss of use, data, or prots, whether
or not advised of the possibility of damage, and on any theory of liability, arising out of or in connection with the use or
performance of the LABvault-HD.
Dimensions1.75”H x 14”W x 9”D (19”W with rack ears)
Weight, without carton
or cables
Front Panel Display2x16 character liquid crystal display
KeypadSix push button keypad
Power InputThree-position IEC power input with removable power cord
Power SupplyInternal 200W power supply with active P.F.C., which accepts 90-264VAC @ 47-
The LABvault-HD’s HD/SD digital video channel operates as either a player or
recorder. Initiating playback during recording stops recording and likewise starting
recording during playback stops video playback. The LABvault-HD encoder/decoder
supports the following:
• H.264 High Prole video encoding/decoding, HD Level 4 and SD Level 3
• MPEG-1 Layer II audio encoding/decoding
• HD (1080i and 720p) and Standard Denition (480i) playback and recording
• High Denition
○ 1920 x 1080 (29.97 Hz Interlaced, IBP group of pictures [GOP]
structure)
○ 1280 x 720 (59.94 Hz progressive, IBBP GOP structure)
¾ Standard Denition: 720 x 480 (29.97 Hz interlaced, IBBP GOP structure)
• 4:2:0 chroma subsampling, 8-bit, YCbCr
Automatic video and audio multiplexing during recording results in a single MPEG-
2 transport stream (.m2t) le containing an H.264 High Prole video stream
and MPEG-1 Layer II audio.. The maximum recorded le length allowed by the
LABvault-HD is 23 hours, 59 minutes, and 50 seconds.
Digital video recording results are based on a combination of the selected recording
quality default and the quality of the input source. Video being fed to the encoder
must have stable sync. Input signals with copy protection are not recordable.
The LABvault-HD encoder can capture HD (1080i and 720p) and Standard Denition
(480i) video at one of the following recording qualities:
• Good: VBR of 3.00-5.00 Mb/s, incoming video signal with a resolution of
1920 x 1080i is recorded at a video resolution of 1440 x 1080i; all other
signals recorded at their native resolutions, 192 kb/s audio bit rate, 48 kHz
audiosample rate
NOTE: This setting is best for reducing le size when recording signals with
lower levels of action. The LABvault-HD records the incoming HD 1920 x
1080i video signal at a resolution of 1440 x 1080i while preserving the 16:9
aspect ratio of the video in an anamorphic format.
• Better: VBR of 4.00-7.00 Mb/s, resolution same as source, 192 kb/s audio bit
rate, 48 kHz audiosample rate
• Best: VBR of 7.00-9.00 Mb/s, resolution same as source, 224 kb/s audio bit
rate, 48 kHz audiosample rate
• Two BNC-F HD/SD-SDI video inputs
• Two BNC-F HD/SD-SDI video outputs
• Society of Motion Pictures and Television Engineers (SMPTE) standards for
inputs/outputs:
►
HD: SMPTE292M
►
SD: SMPTE259M
• Support for embedded audio
Digital and Analog Audio
Inputs/Outputs
• Digital AES balanced audio connections
• Analog balanced audio connections
2018-08-07Page 31
Page 36
LABvault-HD
Product Warranty
PRODUCT WARRANTY
LEIGHTRONIX, INC. warrants this digital video LABvault-HD encoder against defective workmanship
or materials for a period of ve (5) years from the original date of purchase.
During this warranty period, any parts found to be defective will be replaced at no charge. Labor to
repair or replace defective parts will also be performed at no charge during the warranty period.
This warranty does not cover abuse, shipping damage, neglect, tampering by unauthorized
personnel, acts of God, damage inadvertently caused by the user, preventive maintenance, or any
product whose serial number is removed or defaced.
The sole responsibility of LEIGHTRONIX shall be to repair or replace in accordance with this
warranty. The seller’s and manufacturer’s only obligation shall be to repair or replace such quantity of
the product proved to be defective.
The customer shall bear the cost of shipping products returned to LEIGHTRONIX for warranty repair.
The cost for return shipment to the customer will be assumed by LEIGHTRONIX and shipped via an
equal priority service shipper prepaid and insured.
Neither seller nor manufacturer shall be liable for any injury, loss or damage, direct or consequential,
arising out of the use of, or the inability to use the product. Before using, the user shall determine the
suitability of the product for his/her intended use, and user assumes all risk and liability whatsoever in
connection therewith.
The warranty and the obligations and liabilities thereunder shall replace all other warranties or
guarantees, express or implied.
DECLARATION OF STANDARDS CONFORMITY
FCC NOTICE
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Changes or modications to this device not expressly approved by LEIGHTRONIX,
INC. could void the user’s authority to operate this device.
This equipment is intended to be installed in a controlled environment with restricted access.
Page 322018-08-07
Page 37
Copyright Statements
COPYRIGHT STATEMENTS
The LABvault-HD rmware contains portions of the software referenced in the following copyright statements.
WHITSOFT SLIMFTPD
Portions of the LEIGHTRONIX FTP Server are derived from WhitSoft SlimFTPd.
Copyright (c) 2006, Matt Whitlock and WhitSoft Development
All rights reserved.
Redistribution and use in source and binary forms, with or without
modication, are permitted provided that the following conditions are met:
* Redistributions of source code must retain the above copyright notice,
this list of conditions and the following disclaimer.
* Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation
and/or other materials provided with the distribution.
* Neither the names of Matt Whitlock and WhitSoft Development nor the names
of their contributors may be used to endorse or promote products derived
from this software without specic prior written permission.
LABvault-HD
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY
EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Redistribution and use in source and binary forms, with or without modication, is permitted provided that the following
conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following
disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following
disclaimer in the documentation and/or other materials provided with the distribution.
3. The name “PHP” must not be used to endorse or promote products derived from this software without prior written
permission. For written permission, please contact [email protected].
4. Products derived from this software may not be called “PHP”, nor may “PHP” appear in their name, without prior
written permission from [email protected]. You may indicate that your software works in conjunction with PHP by
saying “Foo for PHP” instead of calling it “PHP Foo” or “phpfoo”
5. The PHP Group may publish revised and/or new versions of the license from time to time. Each version will be given
a distinguishing version number. Once covered code has been published under a particular version of the license,
2018-08-07Page 33
Page 38
LABvault-HD
Copyright Statements
you may always continue to use it under the terms of that version. You may also choose to use such covered code
under the terms of any subsequent version of the license published by the PHP Group. No one other than the PHP
Group has the right to modify the terms applicable to covered code created under this License.
6. Redistributions of any form whatsoever must retain the following acknowledgment: “This product includes PHP, freely
available from <http://www.php.net/>”.
THIS SOFTWARE IS PROVIDED BY THE PHP DEVELOPMENT TEAM ``AS IS’’ AND ANY EXPRESSED
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT
SHALL THE PHPDEVELOPMENT TEAM OR ITS CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
This software consists of voluntary contributions made by many individuals on behalf of the PHP Group.
For more information on the PHP Group and the PHP project, please see <http://www.php.net>.
This product includes the Zend Engine, freely available at <http://www.zend.com>.
GD STATEMENT
• Portions copyright 1994, 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004 by Cold Spring Harbor
Laboratory. Funded under Grant P41-RR02188 by the National Institutes of Health.
• Portions copyright 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004 by Boutell.Com, Inc.
• Portions relating to GD2 format copyright 1999, 2000, 2001, 2002, 2003, 2004 Philip Warner.