Leicke Sharon LH67402 User Manual

User's Manual
LEICKE Sharon Blood Pressure Monitor
with Bluetooth
Product number: LH67402
Thank you for purchasing the Blood Pressure Monitor from LEICKE Sharon.
We continuously work on the development of our products, our customer support and innovations. Our products have a long service life, are eco-friendly and high performing. Furthermore, every day we do our very best to satisfy you as our customer. That is why you, no matter if private or business customer, are in the focus of our company’s efforts. We take your reviews and proposals seriously and evaluate them continuously. That way, we get to know you and your demands on our products and services better and thus allow for positive enhancements.
To discover more about LEICKE products or if you have any questions about this product
visit our website www.leicke.com.
PACKAGE CONTENTS
Before attempting to use this device, please check the packaging and make sure the following items are contained in the package:
Number of
Pieces
Name
Note
1
Blood Pressure Monitor (USB interface)
Bluetooth 4.0
2
USB Cable
-
1
User's Manual
-
TECHNICAL DETAILS
Input voltage
USB, 5V
Input current
60mA
Measurement mode
Oscillographic testing mode
Measurement range
Rated cuff pressure: 0mmHg-300mmHg(0kPa-40kPa) Measurement pressure: 40mmHg-230mmHg ( 5.3kPa-30.7kPa ) pulse value:(40-199)beat/minute
Accuracy
Pressure: 5°C – 40°C within ± 3mmHg (0.4kPa) pulse value: ±5%
Normal working condition
Temperature: 5°C to 40°C Relative humidity: 85%RH Atmospheric pressure: 86kPa to 106kPa
Storage & transportation condition
Temperature: -20°C to 60°C Relative humidity: 10%RH to 93%RH Atmospheric pressure: 50kPa to 106kPa
Degree of protection
Type BF applied part
Protection against ingress of water
IP22 Software version
V01
Device classification
Battery Powered Mode: Internally Powered ME Equipment AC Adaptor charged Mode: Class II ME Equipment
RF Frequency Range
2402 MHz to 2480 MHz
Transmitting Distance
10 m
Weight
108 g
Dimensions
Size: 79.8 mm x 72.5 mm x 13.2 mm
PRODUCT INFORMATION
The device features blood pressure measurement, pulse rate measurement and the result storage. Readings taken by this device are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method. This manual contains important safety and care information, and provides step by step instructions for using the product. Please do read this user manual carefully and thoroughly before use.
FEATURES:
Systolic Blood Pressure Diastolic Blood Pressure Pulse Rate Memory: Up to 60 pieces of records
MEASUREMENT PRINCIPLE
This product uses the Oscillometric Measuring Method to detect blood pressure.
Before every measurement, the unit establishes a “zero point” equivalent to the
atmospheric pressure. Then it starts inflating the cuff. Meanwhile, the unit detects pressure oscillation generated by beat-to-beat pulsatile, which is used to determine the systolic pressure and diastolic pressure as well as pulse rate. The device also compares the longest and the shortest intervals of detected pulse wave with the average value, and then calculates the standard deviation. The monitor will light up a warning symbol when the calculated standard deviation is larger than or equal to 15.
SAFETY INFORMATION
The signs below might be in the user manual, labelling or other components. They are the requirement of standard and using.
Symbol for “THE OPERATION GUIDE MUST BE READ”
Symbol for “TYPE BF APPLIED PARTS”
Symbol for “COMPLIES WITH
MDD 93/42/EEC
REQUIREMENTS”
Symbol for “ENVIRONMENT
PROTECTION - Electrical waste products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice”
Symbol for “MANUFACTURER” Symbol for “SERIAL NUMBER”
Symbol for “DIRECT CURRENT”
Symbol for “Including RF transmitter”
Symbol for “Authorised
Representative in the European
Community”
Caution: These notes must be observed to prevent any damage to the device.
Symbol for “MANUFACTURE DATE”
INDICATIONS FOR USE
The LEICKE Sharon Blood Pressure Monitor is a digital monitor intended for measuring blood pressure and heartbeat rate with wrist circumferences ranging from 13.5 cm to 21.5 cm ( about 5¼ inches to 8½ inches ). It is intended for adult indoor use only.
CAUTION:
* Intended for adult indoor use only. Pregnant women, neonatal patients, pre-eclamptic patients and patients with severe obesity must not use the device. If in need, please consult a professional doctor. * Intended for non-invasive measuring and monitoring of arterial blood pressure. Not intended for use on extremities other than wrist or for functions other than obtaining a blood pressure measurement. * Please use device under user manual specified environment, otherwise accuracy may be influenced. * Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure. Do not start or end medical treatment without asking a physician for treatment advice. * If you are taking medication, consult your physician to determine the most appropriate time for your
measurement. Never change a prescribed medication without your physician’s consent. * If the cuff’s pressure exceeds 40 kPa (300 mmHg), the unit will automatically deflate. If the cuff doesn’t deflate when its pressure exceeds 40 kPa (300 mmHg), detach cuff from wrist and
press the START/STOP button to stop inflation. * Do not use the monitor under a strong electromagnetic field (e.g. medical RF equipment) that radiates interference signals or electrical fast transient/ burst signals. * The maximum temperature of the device is 42.5°C the environmental temperature being 40°C. * The device is not AP/APG equipment. It is not suitable for use in the presence of a flammable anaesthetic mixture with air (or oxygen, nitrous oxide). * Please keep the unit out of reach of infants, children or pets, since inhalation or swallowing of small parts is dangerous or even fatal. * Please use ACCESSORIES and detachable parts specified / authorised by MANUFACTURER. Otherwise, it may cause damage to the unit or endanger the user / patient. * The patient is an intended operator. The patient can measure, transmit data and charge battery under normal circumstances and maintain the device and its accessories according to the user manual. * The blood pressure monitor, its adaptor, and the cuff are suitable for use within the patient's environment. If you are allergic to dacron or plastic, please don’t use this device. * The device is not intended for PATIENT transport outside a healthcare facility. * This device cannot be used with HF surgical equipment at the same time. * There is a PTC current limiter in the monitor, whose specification is 8V and 0.5A. When the voltage and current exceed the limiting value, the monitor will stop working. * The adaptor is specified as a part of ME equipment. * The device is not suitable for public use. * The adapter insulates the device from the main supply. Do not position the plug in a position where it is difficult to disconnect from the supply mains. * Sensitive people, including pregnant women pre-eclamptic patients, patients who implanted medical electronic instruments and have atrial fibrillation (AF), premature ventricular beats and peripheral arterial disease (PAD)., should avoid using the unit whenever possible. * This unit is not suitable for continuous monitoring during medical emergencies or operations. * Manufacturer will make available on request circuit diagrams, component parts list etc.
LCD DISPLAY SIGNAL
SYMBOL
DESCRIPTION
EXPLANATION
SYS
Systolic Blood Pressure
High blood pressure
DIA
Diastolic Blood Pressure
High blood pressure Pulse
Beat/minute
Low Battery
Low battery - please charge
mmHg
Unit
Measurement unit of blood pressure (1mmHg=0.133kPa)
IHB Detector
Irregular Heartbeat Detector
Bluetooth
Successful Bluetooth Connection
Error
Error
Memory
Recalling the history records
Time
Hour: Minute (Month/Day/Year)
Heartbeat
Heartbeat detection during the measurement
Monitor Components
SYSTOLIC
DIASTOLIC
PULSE RATE
TIME
MEM/UP START/STOP BUTTON
BUTTON
SET/DOWN
BUTTON
Component list of pressure measuring system:
CUFF
(Type BF applied part)
1. PCBA
2. Air Pipe
3. Pump
4. Valve
5. Cuff
USB Interface
Charging the Device
1. The battery of the monitor is a built-in rechargeable lithium-ion battery, the battery
current is 420 mAh.
2. Please use the USB cable to charge the battery, just like the following pictures:
Method 1 Method 2
Charging the power under following circumstances:
displays on the LCD
The LCD display dims
• When switching on the monitor, the LCD doesn’t light up.
CAUTION:
1. The battery of the monitor is built-in rechargeable lithium-ion battery, please do not disassemble yourself or by unauthorized maintenance personnel.
2. When used normally, it can be charged about 300 times, if the battery cannot be charged normally or the blood pressure monitor cannot be used normally, please contact authorized maintenance personnel. If you measure three times per day, and the battery was fully charged, it can be used for about 20 days.
3. Store and use the blood pressure monitor in a cool, dry and ventilated environment. Avoid fire and heat sources, or the battery may explode.
4. Only use the authorized USB cable (5V 1A) to charge power.
5. During the charging process, the blood pressure monitor displays:
When charging is finished, please pull the plug in time.
CAUTION:
6. When charging, do not touch charging connector and patient simultaneously.
7. Do not attempt to replace your blood pressure monitor’s battery. It is built-in and not changeable.
8. Only charge the battery in accordance with the user instructions supplied with the blood pressure monitor.
9. Avoid charging your blood pressure monitor in extremely high or low temperatures.
10. Do not use your blood pressure monitor while you are charging it.
11. Do not attempt to disassemble the blood pressure monitor or force open the built-in battery.
12. Do not clean the blood pressure monitor when it is being charged. Always unplug the charger first before cleaning the blood pressure monitor.
13. Do not dispose of your blood pressure monitor in a fire. The battery could explode causing injury or death.
14. Batteries (battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or the like.
Activate Your Blood Pressure Monitor
Getting the Blood Pressure Monitor, the first thing to do after charging is to activate it. Please press and hold the SET button to activate it and enter setting mode.