Overview

Overview
The Leica DISTO™ is a laser distance meter oper­ating with a class2 laser. See chapter Technical data for scope of use.
1Display
2ON/ Measure
3Clear/ OFF
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
2
Page 4

Technical data

Tech nicaldata
General
Accuracywith favourable conditions * 2 mm / 0.08 in ***
Accuracywith unfavourable conditions ** 3 mm / 1/8" ***
Range with favourable conditions* 0.2 - 40 m / 0.6 - 120 ft ***
Range with unfavourable conditions** 0.2 - 30 m / 0.6 - 100 ft ***
Smallest unit displayed 0.1 mm / 1/32 in
Laser class 2
Laser type 635 nm, <1 mW
ø laser point | at distances 6 /30 /60 mm | 10/ 50/ 100 m
Protection class IP54 (dust- and splash water protected)
Auto. laser switch off after 90 s
Auto. power switch off after 180 s
Bluetooth® Smart Bluetooth® v4.0
Range of Bluetooth® Smart <10m
Battery durability(2 x AAA) up to 10000 measurements
Dimension (H x D x W) 115 x 43.5 x 23.5 mm | 4.53 x 1.71 x 0.93 in
Weight (with batteries) 87 g/ 3.07 oz
Temperature range Storage | Operation -25 to 70°C/ -13 to 158°F | -0 to 40°C/ 32 to 104°F
* favourable conditions are: white anddiffuse reflecting target (white painted w all), l ow background illuminationand moderate temperatures.
** unfavourable conditions are: targets with l ower or higher reflectivity or highbackground il lumination or temperatures at the upper or lower end of the specifiedtemperature range.
*** Tolerances apply from 0.05 m to 5 m with a confidence level of 95%.
With favourable conditions thetolerancem ay deteriorate by 0.10 m m/m for distances above 5 m.
With unfavourable conditions thetolerance may deteriorate by 0.15m m/m for distances above 5 m.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
3
Page 5
Technical data
Func tions
Distance measuring yes
Permanent measuring yes
Beep yes
Illuminated display yes
Bluetooth® Smart yes
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
4
Page 6

Instrument Set-up

InstrumentSet-up
Introduction
The safety instructions (see Safety Instructions) and the user manual should be read through carefully before the product is used for the first time.
The person responsible for the product must ensure that all users understand these directions and adhere to them.
The symbols used have the following meanings:
WARNING
Indicatesa potentiallyhazardous situ­ation or an unintended use which,if not avoided, will resultin death or ser­ious injury.
CAUTION
Indicatesa potentiallyhazardous situ­ation or an unintended use which,if not avoided, may result in minor injury and/or appr eciablematerial, financial and environmental damage.
Important par agraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
5
Page 7
Instrument Set-up
Insert batteries
To ensure a reliable use, we recom­mend using high qualityAlkaline bat­teries. Change batterieswhen battery symbol is flashing.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
6
Page 8
Instrument Set-up
Switching ON/OFF
Device is turned OFF.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
7
Page 9
Instrument Set-up
Clear
Undo last action. Leave actualfunction, go to default
operation mode.
Leica DISTO™ D1
8
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 10
Instrument Set-up
Message Codes
If the message "i" appears with a number, observe the instruc­tions in Message Codes section. Example:
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
9
Page 11
Instrument Set-up
Settings
Press both keys simultaneousley. Switch between the following units:
0.000 m 0'00" 1/16
0.0000 m
0.000 in
0.00 f t 0 in 1/16
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
10
Page 12

Operations

Operations
Measuring single distance
surfaces the measuring time increases.
Leica DISTO™ D1
Aim active laser at target.
Target surfaces: Measuring errors can occur when meas­uring to colourlessliquids, glass, styrofoam or permeable sur­faces or when aiming at high glosssurfaces. Against dark
11
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 13
Operations
Permanent measuring
Leica DISTO™ D1
The last value measured is displayed in the main line.
Stops permanent measuring.
12
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 14
Operations
Bluetooth® Smart
DISTO™ sketch.Use App for Bluetooth® data transfer.
Bluetooth® Smart is always act­ive when the device is switched on. Connect the device with your smart-phone, tablet, laptop.. Measurement values willbe transferred automatically right after a measurement. The efficient and innovative Bluetooth® Smart module (with the new Bluetooth® standard V4.0) works together with all Bluetooth® Smart Ready
devices. Allother Bluetooth® devices do not support the energy saving Bluetooth® Smart Module, which is integ­rated in the device.
We provide no warranty for free DISTO™ software and offer no support for it. We accept no liab­ility whatsoever arising from the use of the free software and we are not obliged to provide cor­rections nor to develop
upgrades. A wide range of com­mercial software can be found on our homepage. Apps for Android® or iOS can be found in special internet shops. For more details, see our homepage.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
13
Page 15

Message Codes

Messa geCode s
No. Cause Correction
204 Calculation error Perform measurement again.
220 Hardware error Contact your dealer
240 Data transfer error Connect deviceand repeat procedure
252 Temperature too high Let device cool down.
253 Temperature too low Warm device up.
255 Received signal too weak, measuring time too long Change target surface ( e.g. white paper).
256 Received signal too high Change target surface ( e.g. white paper) .
257 Too much background light Shadow target area.
* If other messagecodes are displayedfrequently even the instrument has been swi tched off and on, please contact your dealer.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
14
Page 16

Care

Care
l Clean the device with a damp, soft cloth.
l Never immerse the device in water.
l Never use aggressive cleaning agents or
solvents.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
15
Page 17

Warranty

Warranty
Warranty under PROTECT by Leica Geosystems
Lifeti me Manufacturer´s Warranty
Warranty coverage for the entire usage time of the product under PROTECT according to Leica Geosystems International Limited Warr anty and PROTECT General Terms & Conditions set out
charge repair or replacement of allproducts or any parts under PROTECT that suffer defects as a result of faults in materialsor workmanship.
3 Years No Cost
Additionalservices should the product under PROTECT become defective and require ser­vicing under normal conditions of use, as described in the user manual, at no additional charge.
To receive the "3 Years No Cost" period, the product under PROTECT must be registered at
the purchase date. If the product under PROTECT isnot registered, a "2 years No Cost" period applies.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
16
Page 18

Safety instructions

Safetyinstructions
The person responsible for the instrument must ensure that allusers understand these directionsand adhere to them.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
17
Page 19
Safety instructions
Symbols used
The symbols used have the following meanings:
WARNING
Indicatesa potentiallyhazardous situation or an unintended use which, if not avoided, willresult in death or serious injury.
CAUTION
Indicatesa potentiallyhazardous situation or an unintended use which, if not avoided, may result in minor injury and/or appreciable material, financial and environmental damage.
Important par agraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner .
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
18
Page 20
Safety instructions
Permitted use
l Measuring distances
l Data transfer with Bluetooth®
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
19
Page 21
Safety instructions
Prohibited use
l Using the product without instruction
l Using outside the stated limits
l Deactivation of safety systems and
removal of explanatory and hazard labels
l Opening of the equipment by using tools
(screwdrivers, etc.)
l Use of accessories from other man-
ufacturers without express approval
l Carrying out modification or conversion
of the product
l Deliberate dazzling of third parties; also in
the dark
l Inadequate safeguards at the surveying
site (e.g. when measuring on roads, con­struction sites, etc.)
l Deliberate or irresponsible behaviour on
scaffolding, when using ladders, when measuring near machines whichare run­ning or near parts of machines or install­ations which are unprotected
l Aiming directlyin the sun
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
20
Page 22
Safety instructions
Hazards in use
WARNING
Watch out for erroneous measurements if the instrument isdefective or if it has been dropped or has been misused or modified. Carry out periodic test measurements. Particularlyafter the instru­ment has been subject to abnormal use, and before, during and after important meas­urements.
CAUTION
Never attempt to repair the product yourself. In case of damage, contact a localdealer.
WARNING
Changes or modificationsnot expresslyapproved could void the user´ s authority to operate the equipment.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
21
Page 23
Safety instructions
Limits of use
Refer to section Technicaldata. The device isdesigned for use in areas permanently hab­itable by humans. Do not use the product in explosion hazardous areas or in aggressive environments.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
22
Page 24
Safety instructions
Areas of responsibility
Responsi bil ities of the manufacturer of the ori­ginal equipment:
The company above is responsible for supplying the product, including the User Manual in a com­pletelysafe condition.
The company above is not responsible for third party accessories.
Responsi bil ities of the person in c harge of the ins trument:
l To understand the safety instructionson
the product and the instructions in the User Manual.
l To be familiar with local safety regulations
relating to accident prevention.
l Alwaysprevent accessto the product by
unauthorised personnel.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
23
Page 25
Safety instructions
Disposal
CAUTION
Flat batteries must not be disposed of with house­hold waste. Care for the environment and take them to the collection pointsprovided in accord­ance with national or localregulations.
The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regulations in force in your country. Adhere to the nationaland coun­try specific regulations.
Product specific treatment and waste man­agement can be downloaded from our homepage.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
24
Page 26
Safety instructions
Electromagnetic Compatibility
(EMC)
WARNING
The device conforms to the most stringent require­ments of the relevant standards and regulations. However, the possibility of causing interference in other devices cannot be totallyexcluded.
Japanese Radi o Law Complianc e
This device is gr anted pursuant to the Japanese Radio Law 電 波 法 . This device should not be modified otherwise the granted designation num­ber will become invalid.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
25
Page 27
Safety instructions
FCC statement (applicable in U.S.)
This equipment has been tested and found to com­ply with the limits for a Class B digitalinstrument, pursuant to part 15 of the FCC rules.These limits are designed to provide reasonable protection against harmful interference in a residential install­ation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio com­munications.
However, there is no guarantee that interference willnot occur in a particular installation. If this equip­ment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
l Reorient or r elocate the receiving
antenna
l Increase the separation between the
equipment and the receiver
l Connect the equipment into an outlet on
a circuit different from that to which the receiver isconnected
l Consult the dealer or an experienced radi-
o/TV technician for help
This device complies with part 15 of the FCC rules. Operation is subjected to the following two conditions:
l This device may not cause harmful inter-
ference, and
l this device must accept any interference
received, includinginterference that may cause undesired operation.
FCC Radiati on Expos ure Statement
The radiated rf output power of the instrument is below the FCC radio frequency exposure limits for portable devicesaccording to KDB 447498.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
26
Page 28
Safety instructions
ISED Statement (applicable in
Canada)
This device complies with Industry Canada's license-exempt RSSs. Operation issubject to the following two conditions:
l This device may not cause harmful inter-
ference, and
l this device must accept any interference,
including interference that may cause undesired operation of the device.
Radio F requency ( RF) Expos ure Compliance Statement
The radiated rf output power of the instrument is below the Health Canada's Safety Code 6 exclu­sion limit for portable devices (radiated element separation distancebetween the radiating ele­ment and user and/or bystander is below 20 cm).
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
27
Page 29
Safety instructions
Use of the product with Bluetooth®
WARNING
Electromagnetic radiation can cause disturbances in other equipment, in installations ( e.g. medical ones such as pacemakers or hearing aids) and in aircraft. It can also affect humans and animals.
Precautions :
Although this product conforms to the most strin­gent standards and regulations, the possibility of harm to people and animals cannot be totally excluded.
l Do not use the product near petrol sta-
tions, chemicalplants, in areas with a potentiallyexplosiveatmosphere and where blasting takesplace.
l Do not use the product near medical
equipment.
l Do not use the product in airplanes.
l Do not use the product near your body
for extended periods.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
28
Page 30
Safety instructions
Laser classification
The device produces visible laser beams, which are emitted from the instrument: It is a Class2 laser product in accordance with:
l IEC60825-1 : 2014 „Radiation safety of
laser products“
Laser Class 2 products:
Do not stare into the laser beam or direct it towards other people unnecessarily. Eye pro­tection is normallyafforded by aversion responses including the blinkreflex.
WARNING
Looking directly into the beam with opticalaids (e.g. binoculars, telescopes) can be hazardous.
CAUTION
Looking into the laser beam may be hazardous to the eyes.
Wavelength 620 - 690 nm Maximum radiant output power for classification < 1 mW
Pulseduration > 400 ps Pulserepetition frequency 320 MHz Beam divergence
0.16 x 0.6 mrad
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
29
Page 31
Safety instructions
Labelling
Subject to change (drawings, descriptions and technicaldata) without prior notice.
Leica DISTO™ D1
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
30
Loading...