Introduction

Purchase Congratulations on the purchase of a Leica NA720/724/728/730/730 plus.
This manual contains important safety directions as well as instructions for setting up the product and operating it. Refer to "1 Safety Directions" for further informa­tion. Read carefully through the User Manual before you switch on the product.
2
Product identifica­tion
The type and serial number of your product are indicated on the type plate. Enter the type and serial number in your manual and always refer to this information
Type: _______________
Serial No.: _______________
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 3
Symbols The symbols used in this manual have the following meanings:
Type Description
DANGER
WARNING
CAUTION
NOTICE Indicates a potentially hazardous situation or an unintended
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation or an unintended use which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor or moderate injury.
use which, if not avoided, may result in appreciable material, financial and environmental damage.
Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner.
Validity of this manual
NA720/724/728/730/730 plus, Introduction 3
This manual applies to the NA720/724/728/730/730 plus instruments. Differences between the various models are marked and described.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 4
Available docu­mentation
Name Description/Format
NA720/724/ 728/730/730 plus User Manual
Refer to the following resources for all NA720/724/728/730/730 plus docu­mentation:
All instructions required in order to operate the product to a basic level are contained in the User Manual. Provides an overview of the product together with tech­nical data and safety directions.
4
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 5

Table of Contents

In this manual Chapter Page
1 Safety Directions
1.1 General Introduction 7
1.2 Definition of Use 8
1.3 Limits of Use 9
1.4 Responsibilities 10
1.5 Hazards of Use 11
2 Description of the System
2.1 Container Contents 16
2.2 Instrument Components 17
2.3 Understanding Terms and Expressions 18
3Operation
3.1 Preparation 20
3.2 Measurement 27
3.3 Check & Adjust 37
NA720/724/728/730/730 plus, Table of Contents 5
15
20
7
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 6
NA720/724/728/730/730 plus, Table of Contents
6
4 Care and Transport
4.1 Transport 42
4.2 Storage 43
4.3 Cleaning and Drying 44
5 Technical Data
6 Accessories
42
45
48
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 7

1 Safety Directions

1.1 General Introduction

Description The following directions enable the person responsible for the product, and the
NA720/724/728/730/730 plus, Safety Directions 7
person who actually uses the equipment, to anticipate and avoid operational hazards.
The person responsible for the product must ensure that all users understand these directions and adhere to them.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 8
NA720/724/728/730/730 plus, Safety Directions

1.2 Definition of Use

Intended Use Optical height readings.
Optical distance measuring with stadia readings.
8
Reasonably fore­seeable misuse
Use of the product without instruction.
Use outside of the intended use and limits.
Disabling safety systems.
Removal of hazard notices.
Opening the product using tools, for example screwdriver, unless this is permitted for certain functions.
Modification or conversion of the product.
Use after misappropriation.
Use of products with recognisable damages or defects.
Use with accessories from other manufacturers without the prior explicit approval of Leica Geosystems.
Aiming directly into the sun.
Inadequate safeguards at the working site.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 9

1.3 Limits of Use

Environment Suitable for use in an atmosphere appropriate for permanent human habitation: not
DANGER
NA720/724/728/730/730 plus, Safety Directions 9
suitable for use in aggressive or explosive environments.
Local safety authorities and safety experts must be contacted before working in hazardous areas, or close to electrical installations or similar situations by the person in charge of the product.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 10
NA720/724/728/730/730 plus, Safety Directions

1.4 Responsibilities

10
Manufacturer of the product
Person responsible for the product
Leica Geosystems AG, CH-9435 Heerbrugg, hereinafter referred to as Leica Geosys­tems, is responsible for supplying the product, including the user manual and original accessories, in a safe condition.
The person responsible for the product has the following duties:
To understand the safety instructions on the product and the instructions in the user manual.
To ensure that it is used in accordance with the instructions.
To be familiar with local regulations relating to safety and accident prevention.
To inform Leica Geosystems immediately if the product and the application becomes unsafe.
To ensure that the national laws, regulations and conditions for the operation of e.g. radio transmitters or lasers are respected.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 11

1.5 Hazards of Use

CAUTION
DANGER
NOTICE Strong magnetic fields in the immediate vicinity (e.g. transformers, melting
NA720/724/728/730/730 plus, Safety Directions 11
Watch out for erroneous measurement results if the product has been dropped or has been misused, modified, stored for long periods or transported.
Precautions:
Periodically carry out test measurements and perform the field adjustments indicated in the user manual, particularly after the product has been subjected to abnormal use and before and after important measurements.
Because of the risk of electrocution, it is dangerous to use poles and extensions in the vicinity of electrical installations such as power cables or electrical railways.
Precautions:
Keep at a safe distance from electrical installations. If it is essential to work in this environment, first contact the safety authorities responsible for the electrical instal­lations and follow their instructions.
furnaces...) may influence the compensator and lead to measuring errors.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 12
NA720/724/728/730/730 plus, Safety Directions
Precautions:
When working near strong magnetic fields, check results for plausibility.
12
CAUTION
WARNING
WARNING
Be careful when pointing the product towards the sun, because the telescope func­tions as a magnifying glass and can injure your eyes and/or cause damage inside the product.
Precautions:
Do not point the product directly at the sun.
During dynamic applications, for example stakeout procedures there is a danger of accidents occurring if the user does not pay attention to the environmental condi­tions around, for example obstacles, excavations or traffic.
Precautions:
The person responsible for the product must make all users fully aware of the existing dangers.
Inadequate securing of the working site can lead to dangerous situations, for example in traffic, on building sites, and at industrial installations.
Precautions:
Always ensure that the working site is adequately secured. Adhere to the regulations governing safety and accident prevention and road traffic.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 13
CAUTION
If the accessories used with the product are not properly secured and the product is subjected to mechanical shock, for example blows or falling, the product may be damaged or people can sustain injury.
Precautions:
When setting-up the product, make sure that the accessories are correctly adapted, fitted, secured, and locked in position. Avoid subjecting the product to mechanical stress.
WARNING
WARNING
NA720/724/728/730/730 plus, Safety Directions 13
If the product is used with accessories, for example masts, staffs, poles, you may increase the risk of being struck by lightning.
Precautions:
Do not use the product in a thunderstorm.
If the product is improperly disposed of, the following can happen:
If polymer parts are burnt, poisonous gases are produced which may impair health.
If batteries are damaged or are heated strongly, they can explode and cause poisoning, burning, corrosion or environmental contamination.
By disposing of the product irresponsibly you may enable unauthorised persons to use it in contravention of the regulations, exposing themselves and third parties to the risk of severe injury and rendering the environment liable to contamination.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 14
NA720/724/728/730/730 plus, Safety Directions
Precautions:
The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regulations in force in your country. Always prevent access to the product by unauthorised personnel.
Product-specific treatment and waste management information can be downloaded
14
WARNING
Only Leica Geosystems authorised service workshops are entitled to repair these products.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 15

2 Description of the System

General descrip­tion
NA720/724/728/730/730 plus, Description of the System 15
The NA720/724/728/730/730 plus is a member of a new generation of construction levels. Its innovative technology makes the daily surveying jobs easier. The instrument is ideally suited for all applications of a reliable and robust construc­tion level. The easy operation of the instrument functions can be quickly learned even by inex­perienced surveyors.
Easy operation; quickly to learn!
Attractive design; low weight.
Endless drive.
Robust and reliable.
Enables angle measurements with horizontal circle (choice of ° or gon).
Resistant to water and dirt (IP57).
Adaptable to all types of tripods with 5/8" central fixing screw.
Nitrogen filled telescope to prevent fogging the lens.
3 years without additional costs with Leica Protect.
Produced (in accordance to ISO 9001 and ISO 14001) and proofed with ISO 17123-2
Swiss technology
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 16
NA720/724/728/730/730 plus, Description of the System
008716_001
a
b
c
d
e

2.1 Container Contents

Container contents
16
a) Allen key b) Protective cover c) CD user manual d) Customer information,
Manufacturer certification, Protect card
e) Level
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 17

2.2 Instrument Components

008715_001
a
b
c
d
e
f
g
g
h
i
j
k
Instrument compo­nents
a) Level mirror for NA720/NA724; Level
prism for NA728/NA730/NA730 plus
b) Eyepiece c) Cover glass for angle reading (° or gon) d) Focusing knob e) Coarse aiming device (back/fore-sight for
NA720/NA724; optical sight with point marking for NA728/NA730/NA730 plus)
NA720/724/728/730/730 plus, Description of the System 17
f) Objective g) Endless drive (both sides) h) Circular level i) Knurled ring of adjustable hori-
zontal circle j) Footscrew k) Base plate
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 18
NA720/724/728/730/730 plus, Description of the System

2.3 Understanding Terms and Expressions

Plumb line
b
18
008717_001
By centring the circular level the instrument is nearly levelled up. A small instrument tilt remains (the vertical axis tilt).
a
a) Plumb line b) Vertical axis tilt
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 19
Compensator
008809_001
R
V/S
B
A
(ΔH)
b
008788_001
The compensator in the instrument is responsible for compensating the vertical axis tilt enabling an exactly horizontal aiming.
Backsight/Fore­sight/Intermediate sight
For determining the height difference (H) between the ground points A and B the back sight (R) is measured first followed by the forward sight (V). Additional points relating to A are measured as intermediate sight (S).
NA720/724/728/730/730 plus, Description of the System 19
a
a) Plumb line b) Line of sight
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 20
NA720/724/728/730/730 plus, Operation

3 Operation

3.1 Preparation

20
Tripod
When setting up the tripod pay attention
to ensuring a horizontal position of the tripod plate. Slight corrections of inclina­tion can be made with the foot screws of the tribrach. Larger corrections must be done with the tripod legs.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 21
Loosen the clamping screws on the tripod
a
b
legs, pull out to the required length and tighten the clamps.
a) In order to guarantee a firm foothold
sufficiently press the tripod legs into the ground.
b) When pressing the legs into the ground
note that the force must be applied along the legs.
Careful handling of tripod.
Check all screws and bolts for correct fit.
During transport always use the cover supplied.
Use the tripod only for surveying tasks.
NA720/724/728/730/730 plus, Operation 21
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 22
NA720/724/728/730/730 plus, Operation
008790_001
Levelling up, step-by-step
1. Place level onto tripod head. Tighten central fixing screw of tripod.
2. Turn footscrews of tribrach into its centre position.
3. Centre circular level by turning the foot­screws.
22
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 23
Centring the circular level
008791 001
A
B
C
1. Turn footscrews A and B simultaneously in opposite directions until bubble is in the centre (on the imaginary "T").
2. Turn footscrew C until bubble is centred.
NA720/724/728/730/730 plus, Operation 23
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 24
NA720/724/728/730/730 plus, Operation
Selection of angle
Changing between ° and gon:
reading
1
24
3
2
008803_001
Degree
0
35010
Gon
0
39010
Step Description
1. Loosen screws with Allen key and remove cover glass.
2. Turn cover glass.
3. Insert cover glass and tighten screws again.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 25
Focusing telescope
008816_001
25
26
27
008817_001
Step Description
1. Aim telescope against a bright background (e.g. white paper).
2. Turn eyepiece until reticule is sharp-focused and deep black. Now the eyepiece is adapted to your eye.
3. Aim telescope on staff using the coarse aiming device.
4. Turn focusing knob until image of staff is sharply focused. If the eye is moved up and down behind the eyepiece the image of the staff and the reticle may not be displaced against each other.
NA720/724/728/730/730 plus, Operation 25
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 26
NA720/724/728/730/730 plus, Operation
008818_001
Centring
Step Description
For possible centring over a ground point:
1. Attach plumb bob.
2. Loosen central fixing screw slightly and shift instru­ment parallel on tripod until the plummet is exactly over the point.
3. Tighten central fixing screw.
26
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 27

3.2 Measurement

H
d
26
27
H
008793_001
Height reading
NA720/724/728/730/730 plus, Operation 27
Before starting field work or after longer periods of storage/transport of
your equipment check the field adjustment parameters specified in this User Manual. Reduce possible vibrations by holding the tripod legs.
If the optical parts of your instrument are dirty of fogged, your measure-
ments can be affected. Keep clean all optical parts of your instrument and follow the cleaning instructions specified in the User Manual.
Step Description
1. Setup instrument, level and sharp-focus the reti­cule.
2. Setup level staff vertically (refer also to Instruction Manual of staff).
3. Roughly aim on staff using the coarse aiming device.
4. Sharp-focus using the focusing knob.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 28
NA720/724/728/730/730 plus, Operation
25
26
27
L
008794_001
Step Description
5. Fine-aim on staff using the endless drives.
6. Check if circular level is centred (view level prism/level mirror).
7. Read off height H at the centre hair of the reticle. Example above: H = 2.585 m
28
27
26
25
008795_001
Distance meas­uring
Carry out steps 1 to 6 according to height reading.
Reading:
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 29
Upper distance line: 2.670 m
0
Degree
35010
008796_001
Lower distance line: 2.502 m Difference L: 0.168 m Distance d: 16.8 m
Result: Distance d = 100 x L
Angle measuring The NA720/724/728/730/730 plus is equipped with a horizontal circle. The gradua-
tion is 1° or 1 gon.
Wanted:
Angle between point A and point B. Carry out steps 1 to 6 according to height measuring. By doing so, align the vertical hair of the reticle to the centre of the staff.
NA720/724/728/730/730 plus, Operation 29
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 30
NA720/724/728/730/730 plus, Operation
60
Degree
5070
008797_001
A
B
Step Description
1. Turn Hz-circle to "0".
2. Align instrument to point B and aim on the
centre of the staff.
3. Read off Hz-angle from Hz-circle:
Example above: Hz = 60°.
Line levelling
30
A
008798_001
R
d
1
V
d
2
I
1
R
2
V
I
2
R
3
V
I
3
B
ΔH
Wanted:
Height difference (H) between point A and B.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 31
Select instrument station and staff location by pacing off so, that approxi-
mately the same target distances result (d1 d2; approx. 40 to 50m).
Procedure:
Step Description
1. Setup instrument at I1.
2. Setup level staff vertically at point A.
3. Aim on staff and read off and take down height (backsight R).
4. Setup level at the changepoint 2, aim on staff and read off and take down
height (foresight V).
5. Setup level at I2, aim on staff at the changepoint 2 and read backsight and
take down.
6. Carry out a foresight at changepoint 3.
7. Continue in the same way until height at point B is measured.
Result:
H = sum backsight - sum foresight
NA720/724/728/730/730 plus, Operation 31
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 32
NA720/724/728/730/730 plus, Operation
1
2
3
4
S3
S2
S1
R
A
S4
008811_001
Example of the booking:
Point No. Backsight R Foresight V Height
A +2.502 650.100
2 +0.911 -1.803
3 +3.103 -1.930
B -0.981 651.902
Sum +6.516 -4.714 H= +1.802
Area levelling
Wanted:
Height difference of several reference points.
32
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 33
The required accuracy is usually not very high with such measurements.
Nevertheless, from time to time read the staff on a stable intermediate point (reading must remain the same).
Procedure:
Step Description
1. Set up instrument centrally between the desired points. The instrument tele-
scope may not be below the highest measured intermediate point.
2. Set up staff vertically at reference point A.
3. Aim on staff and read and take down height (=backsight to known point).
4. Set up staff vertically at point 1.
5. Aim on staff and read and take down height (=measuring intermediate point,
intermediate sight)
6. Repeat steps 4 and 5 for additional intermediate points.
7. The height of individual points are:
Height = Height of station point + backsight (A)
- intermediate sight
NA720/724/728/730/730 plus, Operation 33
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 34
NA720/724/728/730/730 plus, Operation
Example of the booking:
Point No. Interm. sight Height
A592.00
R1 +2.20
594.20
S1 -1.80 592.40
S2 -1.90 592.30
S3 -2.50 591.70
S4 -2.30 591.90
= Instrument horizon
34
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 35
Levelling total
R
A
008802_001
station measuring
Wanted:
Position of several ground points.
The levelling total station measuring is normally carried out during area level-
ling.
Procedure:
Step Description
1. Sequence of measurements is the same as with area levelling. However,
beside the height read also the staff section L (see chapter "Distance meas­uring") and the Hz-angle.
2. Transfer measured value into the map - points are determined by position
and height.
NA720/724/728/730/730 plus, Operation 35
Backsight to known point
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 36
NA720/724/728/730/730 plus, Operation
008823_001
A
2
1
Levelled stakeout
The stakeout is the counterpart to the levelling total station measuring - map points are set out in the field.
Procedure:
Step Description
1. Set up instrument at a known point, centre and level up.
2. Focus instrument and aim on known orientation point.
3. Orient horizontal circle (Hz-direction).
4. Move staff to stakeout point on the basis of known values (distance and Hz-
angle, height) and stakeout point.
36
Measuring ground points
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 37

3.3 Check & Adjust

TSOX_122
1
2
3
Service the tripod step-by-step
The connections between metal and timber components must always be
firm and tight.
1) Tighten the leg cap screws moderately with the allen key supplied.
2) Tighten the articulated joints on the tripod head just enough to keep the tripod legs open when lifting the tripod off the ground.
3) Tighten the screws of the tripod legs.
NA720/724/728/730/730 plus, Operation 37
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 38
NA720/724/728/730/730 plus, Operation
008799_001
2
1
3
Δ
Circular Level
Step Description
1. Level up instrument.
2. Turn instrument by 180°.
3. If bubble of level is outside the circle then it should be adjusted (see point 4.).
38
4. Correct the half error using an Allen key and repeat steps 2 and 3 until the bubble of level is in the centre in any telescope direction.
Δ/2
008800_001
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 39
Checking the line
dd
A
B
ΔH
H=1.832 H=1.616
δδ
I
1
008979_001
of sight
NA720/724/728/730/730 plus, Operation 39
Step Description
1. Choose a distance of appr. 30 m
2. Set up a staff at both final points (A,
3. Set up the instrument at point I1
4. Read both staffs.
With the circular bubble centred and adjusted, the line of sight should be horizontal.
within a gentle terrain.
B).
(halfway between A and B, just pass it down) and centre the bubble.
Reading on A = 1.832 m Reading on B = 1.616 m H = A - B = 0.216 m
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 40
NA720/724/728/730/730 plus, Operation
A
B
ΔH
δ
I
2
008980_001_en
actual = 1.604
nominal = 1.388
Step Description
5. Set up the level about 1 m from staff
A.
6. Read staff A (eg.: 1.604 m).
7. Find nominal reading B; eg.:
Reading A - H = 1.604 m - 0.216 m =
1.388 m.
8. Read staff B, compare nominal-
/actual- reading.
40
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 41
Adjusting the line of sight
NA720/724/728/730/730 plus, Operation 41
Step Description
When the difference nominal-/actual- reading is
more than 3 mm the line of sight must be adjusted.
1. Turn the allen key until the middle hair gives the required reading (eg. 1.388 m).
2. Check line of sight again.
Before starting field work or after long periods of
storage/ transport of your equipment check the field adjustment parameters specified in this User Manual.
008815_001
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 42
NA720/724/728/730/730 plus, Care and Transport

4 Care and Transport

4.1 Transport

42
Transport in the field
Transport in a road vehicle
Shipping When transporting the product by rail, air or sea, always use the complete original
Field adjustment Periodically carry out test measurements and perform the field adjustments indicated
When transporting the equipment in the field, always make sure that you
either carry the product in its original transport container,
or carry the tripod with its legs splayed across your shoulder, keeping the attached product upright.
Never carry the product loose in a road vehicle, as it can be affected by shock and vibration. Always carry the product in its transport container, original packaging or equivalent and secure it.
Leica Geosystems packaging, transport container and cardboard box, or its equiva­lent, to protect against shock and vibration.
in the User Manual, particularly after the product has been dropped, stored for long periods or transported.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 43

4.2 Storage

Product Respect the temperature limits when storing the equipment, particularly in summer
Field adjustment After long periods of storage inspect the field adjustment parameters given in this
NA720/724/728/730/730 plus, Care and Transport 43
if the equipment is inside a vehicle. Refer to "5 Technical Data" for information about temperature limits.
user manual before using the product.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 44
NA720/724/728/730/730 plus, Care and Transport

4.3 Cleaning and Drying

44
Product and acces­sories
Damp products Dry the product, the transport container, the foam inserts and the accessories at a
Blow dust off lenses.
Never touch the glass with your fingers.
Use only a clean, soft, lint-free cloth for cleaning. If necessary, moisten the cloth with water or pure alcohol. Do not use other liquids; these can attack the polymer components.
temperature not greater than +40°C/+104°F and clean them. Do not repack until everything is dry. Always close the transport container when using in the field.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 45

5 Technical Data

Accuracy Standard deviation for 1 km double levelling ISO17123-2:
NA720: 2.5 mm NA724: 2.0 mm NA728: 1.5 mm NA730: 1.2 mm NA730 plus: 0.7 mm
Height accuracy for a single measurement at 30 m:
NA720: 1.5 mm NA724: 1.2 mm NA728: 1 mm NA730: 0.8 mm NA730 plus: 0.4 mm
Telescope
NA720/724/728/730/730 plus, Technical Data 45
Erect image Magnification
NA720: 20 x NA724: 24 x NA728: 28 x NA730/NA730 plus: 30 x
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 46
NA720/724/728/730/730 plus, Technical Data
Field of view (at 100 m): > 4 m (NA720)
Shortest target distance: < 0.5 m (NA720/NA724)
46
> 3.5 m (NA724) > 3 m (NA728/NA730/NA730 plus)
< 0.7 m (NA728/NA730/NA730 plus)
Distance measure­ment
Compensator
Circular level
Circle
Multiplication factor: 100 (all instruments) Additive constant: 0 (all instruments) Resolution (higher than) 4" (NA720)
Working range: ±15’ Setting accuracy (standard deviation):
Sensitivity: 10’/2 mm
Graduation: 360°/400gon Graduation interval: 1°/1gon
3.5" (NA724) 3" (NA728/NA730/NA730 plus)
0.5’’
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 47
Adaption
To normal or ball head tripod Central fixing screw: 5/8’’
Environmental specifications
NA720/724/728/730/730 plus, Technical Data 47
Temperature
Operating temperature Storage temperature
-20°C to +50°C (-4°F to +122°F)
-40°C to +70°C (-40°F to +158°F)
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Page 48
NA720/724/728/730/730 plus, Accessories
008981_001
a
b
c
d
e

6 Accessories

Purchasable Acces­sory
48
a) Protective cover b) Allen key c) Level base d) Standard level staff e) Tripod
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Loading...