Legrand LC6001 User Manual

INSTRUCTION / INSTALLATION SHEET
j
RFLC Event Controller
301Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
IS-0531 Rev. D
1. Introduction
The Legrand RFLC Event Controller (see Figure 1) provides the capability of controlling any installed RFLC Lighting Control Product subsystem. This control capability is user configurable and initiated via Ethernet or WiFi connected devices, such as PCs and Smart Phones. Using the RFLC Event Controller, the user can Discover and Locate up to 100 RFLC Zones. Once RFLC Zones are Discovered, the user can define system lighting control configurations via: up to 10 Collections of Zones (any discovered Zone can be included within a Collection), up to 10 lighting Scenes (a maximum of 32 Zones can be included within a Scene), and up to 20 Events (up to 2 Scenes can be executed per Event). Control of any discrete Zones, Collections, or Scenes can be initiated via any Ethernet or WiFi connected device (this and other user-specific functionality for this product is covered in greater detail in the online Owner’s Manual at www.legrand.us/support Additionally, automated lighting Scene control of the RFLC Lighting subsystem can be initiated via date and time based Events.
).
Figure 1
LCD Display
2. Description
The RFLC Event Controller unit with a front panel 4-line LCD display (see Figure 1) is provided and contains the following rear panel items (see Figure 2):
o Provides one RJ45 jack for Network connection with separate Link and Activity LEDs. o Provides one recessed Reset push button switch used to reset the unit to “factory default” condition. o Provides one Mode push button switch to select various setup and operational display modes. o Provides one Power/Status LED to indicate the unit’s operational states and status. o Provides one micro-USB jack for powering the unit. o Provides one RF antenna.
Also provided is an AC-DC Adapter, (5Vdc output) and Cable Assembly (USB to micro-USB).
3. Installation
IMPORTANT: Read the documentation that is included with all associated Legrand products before installation. If you are unsure of any of the following installation procedures contact Legrand Technical Support @ 1-800-321-2343 option 1 or contact a Legrand installer. NOTE: Prior to this installation, all other RFLC Lighting Products should be installed and configured!
A. Connect a Cat 5 cable from the RJ45 jack on the rear
panel to a Router port that provides DHCP addressing.
B. Connect the AC-DC Adapter to the micro-USB jack on the
rear panel.
C. When the unit is connected to an active LAN with DHCP
enabled Router connection, upon power up the Display will immediate present “Legrand RFLC Acquiring IP Address”. After successful IP acquisition, the Display will list the IP Address as xxx.xxx.xxx.xxx. After a short period of time the Display will transition to “Legrand RFLC Current Time mm/dd/yy hh:mm”. The Date and Time will be correct only if the unit is connected to an active WAN connection, updating the on-board Real Time Clock. It is possible to manually set the Date and Time using a PC Browser to access the device’s Setup Screens.
D. When the RFLC Event Controller is initially powered up, the Power/Status LED will be solid red in color until an IP
Address has been acquired. At the point of IP Address acquisition, the LED will change to an amber color, indicating a factory status condition (not configured as part of any RFLC Lighting Subsystem). Placing any installed and configured RFLC Device within a 100’ range into “Learn Mode”, will cause the Power/Status LED to change to blinking green, indicating that the Event Controller is now house bound to the existing RFLC Lighting Subsystem. Once the initiating RFLC Device is taken out of “Learn Mode”, the Power/Status LED will change to solid green.
RF
Antenna
Figure 2
Link LED
RJ45 jack
Reset button
Activity LED
Mode button
Power/Status LED
Micro-USB power
ack
©Copyright 2012 by Legrand All Rights Reserved. Page 1 of 4
INSTRUCTION / INSTALLATION SHEET
RFLC Event Controller
301Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
NOTE: To reset the unit to factory condition, push and hold the reset button for 10 seconds, or until the status LED goes to solid amber.
E. By toggling the Mode push button switch, the user can transition through the different Display Modes:
a. IP Address b. Date & Time c. MAC Address d. Firmware Revision
F. Press and hold the Mode button for 2-3 seconds (or until the Power/Status LED starts blinking amber) to perform an
RF Scan. The RF Scan will locate all the devices which the Event Controller can control. The Power/Status LED will return to solid green once the RF Scan has completed. This RF Scan may take several minutes, depending on the size of the RFLC system. There is also an RF Scan option available to the user from the PC Browser Setup Application.
4. Configuration/Operation
A. Using a PC Browser the user can access the Setup Application by entering the IP address shown on the
front panel Display. The Setup Application provides the ability to select for customization “System”, “Zones”, “Collections”, “Scenes”, or “Events”. If you select “System”, you should see a screen similar to the one shown in Figure 3.
B. To adjust the time, day or daylight savings
day/time click on the “Adjust Time Settings” button and you should see a screen similar to the one shown in Figure 4. You can also use this screen to change the zipcode from the 17057 default and change the time zone from the default Eastern Time Zone.
C. If you return to “Lighting” and select “Zones”
after an RF Scan, you will see a list of all the zones (load devices) that the Event Controller found during the RF Scan (see Figure 5).
Figure 3
IS-0531 Rev. D
Figure 4
©Copyright 2012 by Legrand All Rights Reserved. Page 2 of 4
Loading...
+ 2 hidden pages