LEGRAND Keystone RJ 45 Technical Data Sheet

87045 LIMOGES Cedex
Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88
Keystone RJ45 socket cat.5e
UTP
1. GENERAL CHARACTERISTICS
2. PRESENTATION
Colour code and Contact number
Identification number UTP : SK01
Cat. no(s).: 0 331 80
CONTENTS Page
1. General characteristics.............1
2. Presentation .....................1
3. Technical characteristics ...........1
4. Overall dimensions................1
5. Usual connection of RJ45 sockets....2
6. Standards and approvals ...........2
7. Performance................... 3-4
3. TECHNICAL CHARACTERISTICS
3.1 Material characteristics
Contacts: gold/nickel, thickness of gold > 0.8 µm min. Metal parts: bronze, nickel, platinum, gold PBT polycarbonate
3.2 Electrical characteristics
Breakdown voltage 1000 V. Contact resistance 20 mΩ. Insulation resistance 500 MΩ at 100 V DC. Connector tested and guaranteed to support POE signals, standard IEEE
802.3af and POE+, draft standards 802.3at, up to 2500 connections and disconnections with load.
Tests are carried out with 2 simultaneous POE+ circuits producing a minimum total power of 50W.
3.3 Mechanical characteristics
Max. number of connections and disconnections: 5 without refreshing the cable Endurance: 2500 movements (plug insertion/withdrawal) IK03
3.4 Climatic characteristics
Operating temperature: - 40°C to + 70°C Humid heat cycle 21 days
Category colour code: Cat. 5 grey
4. OVERALL DIMENSIONS
17,8
26,7
30,1
Technical data sheet: F01421EN/00 Updated on : Created on: 20/09/2011
1/4
Keystone RJ45 socket cat.5e
568
Cat. no(s).: 0 331 80
5. USUAL CONNECTION OF RJ45 SOCKETS
Accepts the following cable connectors: RJ11 (4 contacts), RJ12 (6 contacts), RJ45 (9 contacts).
Double colour code EIA - TIA 568 A and B on terminals:
- UTP 8 contacts
12345678
EIA 568 A
Conductors supported:
- Single-strand: 0.5 to 0.65 mm, AWG 22 to 25
- Multi-strand: AWG 26
- Polyethylene conductor insulation: max. Ø with insulation 1.58 mm
The RJ45 connectors are equipped with a rotating locking system that does not require special tools and enables rewiring in the event of error.
12345678
EIA
B
This system allows the wire pairs to be spread easily before attaching them to the connector.
Spreading the wires ensures that pairs are separated by the required 13 mm. Spreading the pairs at 90° in relation to the cable ensures the best performance levels.
OK
6. STANDARDS AND APPROVALS
Conforms to standards: ISO/IEC 11801 Edition 2
CENELEC EN 50173-1 2007 ANSI/EIA/TIA 568-B.2-1 IEC series 60603-7
Technical data sheet: F01421EN/00 Updated on : Created on: 20/09/2011