Page 1
TEKDEK
SAFETY RECOMMENDA TION
A 1/16" diameter aircraft cable with end-loop (not included) is recommended for
attaching the xture structural to the upper structural.
™
LED
Luminaire for Parking Garages
TD17 SERIES
INSTALLATION INSTRUCTIONS
1
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should
always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
CE PRODUIT DOIT ÊTRE INSTALLÉ EN CONFORMITÉ AVEC LE CODE DE
L'INSTALLATION PAR UNE PERSONNE QUI connaît BIEN LA CONSTRUCTION ET
LE FONCTIONNEMENT DU PRODUIT ET LES RISQUES ENCOURUS.
DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN
ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT
CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND
LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL
INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS
INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS
SAFETY RECOMMENDATION
A 1/16" diameter cable with end-loop (not included) is recommended
for attaching the xture structural to the upper structural
AIRCRAFT CABLE ATTACH
1/16" DIA. AIRCRAFT CABLE
(SUPPLIED BY OTHERS)
TO UPPER STRUCTURAL
SCREW (SUPPLIED BY OTHERS)
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents
found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
F-4260_091118
Page 2
DIRECT TO SURFACE INSTALLATION
1: Remove tertiary lens (if provided) by unscrewing (4) captive screws.
INSTALLATION INSTRUCTIONS
2
2: Remove heatsinking/LED base by unscrewing (4) captive screws.
These will be the inner most screws.
3: Disconnect the quick connector wires from the LED board and
the driver.
4: Make electrical connection to J-box (for sizes, see next page). Circuit
wire connection must be in J-box. Install housing to surface using (4)
5/16" diameter mounting holes.
5: Re-assemble by reversing the removal procedure.
HOUSING TOP VIEW
QUICK CONNECT
CAPTIVE SCREWS (4)
HOUSING
DRIVER
HEATSINK/LED BASE
CAPTIVE SCREWS (4)
FOR REMOVING HEATSINK
5/16” MOUNTING HOLES (4)
TERTIARY LENS (IF PROVIDED)
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents
found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
F-4260_091118
Page 3
QUICK MOUNT KIT INSTALLATION
INSTALLATION INSTRUCTIONS
2
1: Quick mount plate fastens to a secure J-box.
Screws by others.
2: Align hanger bracket with center slot on
top of xture as shown at right. Fixture
can then hang from bracket while electrical
connections are made.
3: After excess wires are in J-box (see sizes
below), push the xture up to the mounting
plate. Locking hooks should slide through
slots. Twist xture until a “click” is felt or
heard. Fixture is now in place.
USED WITH THE FOLLOWING
JUNCTION BOX SIZES:
4" ROUND
4" SQUARE
3-1/2" OCTAGON
2.50
3.37
3.37
2.50
LOCKING HOOKS
1.
HANGER BRACKET
2.
ALIGN HANGER BRACKET
WITH CENTER SLOT
LOCKING HOOK
3.
SLOTS
QUICK MOUNT PLATE
3.50
4.77
F-4258_091118
Page 4
BIRD GUARD INSTALLATION
DIRECT TO SURFACE & QUICK MOUNT
No tools required. Must install before xture is mounted.
INSTALLATION INSTRUCTIONS
2
1. Fasten tab through slots as shown above.
2. Bird Guard lays inside of casting.
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents
found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
F-4557_041013
Page 5
PENDANT MOUNT INSTALLATION
SWIVEL MOUNT NOT RECOMMENDED
(Kenall does not supply counterbalance system)
1: Attach 3/4" threaded conduit to
housing (provided by others).
INSTALLATION INSTRUCTIONS
2
2: Make electrical connections in
conduit body (supplied by others).
HOUSING TAPPED FOR
3/4” NPS THREAD
CONDUIT BODY AND
CONDUIT (BY OTHERS)
MUST USE SEALANT OR
SEALING LOCKNUT
F-4259_091118
Page 6
TRUNNION KIT INSTALLATION
INSTALLATION INSTRUCTIONS
2
1: Attach housing plate to housing. Align
notch. Use (4) at head screws (provided).
2: Assemble trunninon kits as shown using (4)
¼ -20 × .500" screws and nuts (provided).
3: Attach trunnion brackets to housing plate
with (4) 10-32 × .375" hex head screws
(provided).
4: Make electrical connections in conduit body
(supplied by others).
NOTE: Top of bracket to top of the xture
measurements: 9.1" min; 14.6" max
TRUNNION BRACKETS
HOUSING
PLATE
CONDUIT BODY AND
CONDUIT (BY OTHERS)
(To increase depth,
move this fastner here)
MUST USE SEALANT OR
SEALING LOCKNUT
HOUSING
F-4257_091118
Page 7
TEKDEK
Luminaire for Parking Garages
™
LED
INSTALLATION INSTRUCTIONS
1
TD17 SERIES
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
CE PRODUIT DOIT ÊTRE INSTALLÉ EN CONFORMITÉ AVEC LE CODE DE L'INSTALLATION PAR UNE PERSONNE QUI connaît BIEN LA CONSTRUCTION ET LE
FONCTIONNEMENT DU PRODUIT ET LES RISQUES ENCOURUS.
DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO
NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR
MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS
BIRD GUARD INSTALLATION - PENDANT MOUNT & TRUNNION KIT
1. Bird Guard lays on top of casting.
(For Trunnion Kit remove tabs)
Pendant Mount
2. Attach both sides with (4) screws provided.
NOTE: For LEL option, align hole in bird guard with LED indicator
Trunnion Kit
F-4558_041013
Page 8
MOUNT FIXTURE WITH REGARDS TO
OPTICAL ALIGNMENT KEY DIRECTION
INSTALLATION INSTRUCTIONS
TYPES II, III, IV
DRIVING
LANE
3
TYPE II
LIGHT DISTRIBUTION
PATTERN TYPES
TYPE III
TYPE IV
TYPE V, NORMAL
TYPE V, SQUARE
TYPE V
NORMAL
DRIVING
LANE
TYPE V
SQUARE
KEY
OPTICAL
ALIGNMENT KEY
F-4257_091118
Page 9
INSTALLATION INSTRUCTIONS
CUSTOMER SERVICE
For technical assistance, call 1-800-4KENALL (1-800-453-6255).
WARRANTY
For warranty information visit www.kenall.com/Resources/Certied-Performance-Warranties
9
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents
found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.