LEGRAND Kenall MIGHTY MAC Installation Instructions Manual

MIGHTY MAC
Luminaires for Correctional Applications
INSTALLATION INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS
BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO
AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING
ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS
Read all xture markings and labels to insure correct installation of the xture. Additional information may be located on the xture, separate from this instruction sheet, regarding orientation and mounting restrictions. Disconnect power to nightlight and main circuits before wiring xture. Remove door/housing to gain access to the inside of the xture.
SURFACE MOUNT INSTALLATION
• Disconnect the quick connect from the xture and wire to the appropriate supply wires. Connect xture leads to power supply leads using connectors suitable for the gage and number of wires being used (not included). Connections are to be made in the junction box, not the xture. Black and other colored wires connect to the supply conductor, white xture lead connects to the neutral supply conductor, and the grounding wire must be connected to a suitable ground.
1
• Place xture over an installed electrical junction box. Locate and drill pilot holes in mounting surface. Use xture base as template. Using fasteners and anchors appropriate for the mounting surface and xture weight, (not supplied), mount xture base to building.
• Pull quick connect through wiring access hole and connect to mating connector inside xture. Push quick connector back into junction box.
RECESSED FLANGE INSTALLATION
• Install plaster frame appropriate for the xture (separately purchased accessory), or install threaded rod from ceiling structure above ceiling, using same spacing as mounting holes on xture. Guide xture up into cutout, guiding threaded rod into obround mounting holes in xture. Install washers and nuts to hold xture.
RECESSED GRID INSTALLATION
• Angle the xture into the grid opening and lay the xture onto the suspended ceiling grid.
• Fixtures weighing over 50 lbs. should be fastened to the ceiling grid system, or to the ceiling structure above the suspended ceiling by using threaded rod or steel wires (not provided ) appropriate for the weight of the xture.
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
MIGHTY-MAC_F-0939_091118
INSTALLATION INSTRUCTIONS
2
FOR ALL RECESSED FIXTURES:
• Run a length of exible conduit from the supply point to the xture, and run the appropriate number of conductors. Black or other colored leads connect to the supply conductor, white xture lead connects to the neutral supply conductor, and the grounding wire must be connected to a suitable ground.
• As applicable, reassemble ballast housing, reectors, wireway covers, etc. to the base. Install lamps.
NOTE: For Wet Location rated xtures, check gasket for proper seal between door/housing and mounting surface. To insure the xtures watertight integrity, especially if the xture is mounted in direct exposure to the elements, caulk between the mounting surface and base using a high quality caulking material.
CAUTION
Care should be exercised when these xtures will not be installed immediately upon delivery, and if they will not be put into service immediately after installation. Proper xture performance and a “like new” appearance can only be assured if precautions are taken after xtures arrive. If xtures will be on site but uninstalled for any length of time please follow these precautions to prevent damage to the xtures:
Fixtures should be left palletized in the cardboard gaylord, in an indoor area. If gaylord is opened, xtures should be indoors and left in their plastic bags to protect from dirt and moisture. Care should be taken to protect edges of xture from damage, because the damage to any painted surface will cause rust. Fixtures that are installed, but in an unoccupied area, can also be subject to dirt and moisture. Be aware that conduit runs can direct water inside a xture through the junction box.
Depending on the location, weather in certain localities and certain times of the year can be especially damp. Fixtures in uncontrolled areas that are not in use will likely become covered with condensation. Even wet location rated products are not airtight and moist air will get inside the xture. This situation is most severe since the heat of the xture cannot be used to dry out the xture. This situation is not recommended and eventually rust will begin to form on steel products. Kenall recommends that in these situations, the xture housing be wrapped in a vented plastic bag and closed up against the wall or ceiling. This will provide short term (weeks) protection for CRS products. Longer exposure (month or longer) to these conditions will require a stainless steel housing and hardware.
CUSTOMER SERVICE
For technical assistance, call 1-800-4KENALL (1-800-453-6255). For additional instructions, go to www.kenall.com/Installs
WARRANTY
For warranty information visit www.kenall.com/Resources/Certied-Performance-Warranties
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.