LEGRAND Kenall LUXTRAN LTSIU Installation Instructions Manual

Page 1
LUXTRAN
Luminaires for Tunnel Applications
INSTALLATION INSTRUCTIONS
1
LTSIU SERIES
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND OPERATION OF
THE PRODUCT AND THE HAZARDS INVOLVED.
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE
CODE D’INSTALLATION PERTINENT, PAR UNE
PERSONNE QUI CONNAÎT BIEN LE PRODUIT
ET SON FONCTIONNEMENT AINSI QUE LES
RISQUES INHÉRENTS. DISCONNECT POWER TO ALL
CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE
WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS
The LuxTran LTSIU series luminaires contains sensitive electronics. Take care to avoid damage by improper handling or static electricity discharge (ESD). Either type of damage could render the system inoperable or cause latent failure.
INSTALLATION INSTRUCTIONS
1. Secure xture to wall or ceiling using user supplied hardware. Slots for 3/8 bolts are provided in the mounting brackets. See Figure 1.
.44
.94
10.0
25.5
.41
.91
4.00
25.37
9.75
Figure 1b
20°
20°
5.95
Figure 1a
Figure 1
NOTE: If the xture has directional optics, note the label indicating the direction of light and install appropriately.
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
LTSIU_F-5445_091118
Page 2
INSTALLATION INSTRUCTIONS
2. Rotate latches and open door, which is retained by stainless steel cables.
3. Loosen wing nuts and remove Wiring Cover. See gure 2.
Figure 2
4. Connect weather tight electrical service to 7/8 dia. opening provided.
5. Connect electrical service:
Black- input line, 120-277VAC or 277-480VAC (refer to label for correct input voltage) White- Neutral
2
Copper- ground
6. Replace Wiring Cover and secure with wing nuts.
7. Close door and secure rotating latches.
SERVICE INSTRUCTIONS
LTSIU series LED modules are not eld replacable. LED module replacement may be done after the xture is removed from service.
Before beginning any service operation, be sure the power to the xture is off.
To replace an LED driver-
1. Open door, which is retained by stainless steel cables.
2. Loosen wing nuts and remove Wiring Cover. See Figure 3.
3. Disconnect the driver to be replaced.
4. Remove the retaining strap which secures the driver. See gure 3.
5. Install new driver and secure using restraining strap.
6. Connect to LED modules following the wiring diagram for the particular xture.
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
Figure 3
LTSIU_F-5445_091118
Page 3
INSTALLATION INSTRUCTIONS
To replace LED modules-
1. Open door, which is retained by stainless steel cables.
2. Loosen wing nuts and remove Wiring Cover. See Figure 2.
3. Remove reectors and disconnect LED module leads. See Figure 4.
4. Remove screws securing LED module.
3
Figure 4
5. Secure new LED module by re-installing removed screws.
6. Attach leads and secure reectors.
7. Re-install wiring cover and door.
Wiring Diagrams
100L Wiring
100L Wiring Diagram
Red
LED Module
Blue
Red
Blue
RED
RED
BLUE
BLUE
Purple
Gray
Red
Blue
Green
White
Black
Driver
DIMMING (+)
DIMMING (-)
GREEN
WHITE
BLACK
COPPER
White
BLACK
LED Module
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
Red
Blue
Red
Blue
LTSIU_F-5445_091118
Page 4
INSTALLATION INSTRUCTIONS
4
188L/216L Wiring Diagram
216L Wiring
Red
LED Module
Blue Red Blue
RED
BLUE
Red
LED Module
300L or 400L SINGLE DRIVER Wiring Diagram
300L/390L Wiring for Single Driver
Blue
Red
Blue
Red
LED Module
Blue
Red
Blue
RED
BLUE
RED
BLUE
Purple
Gray
Red
Blue
Green
White
Black
Drivers
Purple Gray
Red
Blue
Green
White
Black
Purple
Gray
Red
Blue
Green
White
Black
Driver
DIMMING (+)
DIMMING (-)
GREEN
BLACK
DIMMING (+)
DIMMING (-)
BLACK
DIMMING (+)
DIMMING (-)
GREEN
WHITE
BLACK
WHITE
COPPER
White
WHITE
Black
COPPER
RED
Red
LED Module
300L/390L Wiring for Multiple Drivers
300L or 400L Multiple Drivers Wiring Diagram
LED Module
Blue
Blue
Red
Blue
Red
Red
Blue
RED
Red
LED Module
Blue
Red
Blue
RED
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
BLUE
BLUE
RED
BLUE
RED
BLUE
BLUE
Drivers
Purple
Gray
Red
Blue
Green
White
Black
Purple
Gray
Red
Blue
Green
White
Black
Purple
Gray
Red
Blue
Green
White
Black
Purple
Gray
Red
Blue
Green
White
Black
DIMMING (+)
DIMMING (-)
DIMMING (+)
DIMMING (-)
DIMMING (+)
DIMMING (-)
DIMMING (+)
DIMMING (-)
GREEN
WHITE
White
BLACK
COPPER
BLACK
White
BLACK
LTSIU_F-5445_091118
Page 5
INSTALLATION INSTRUCTIONS
CUSTOMER SERVICE
For technical assistance, call 1-800-4KENALL (1-800-453-6255).
WARRANTY
For warranty information visit www.kenall.com/Resources/Certied-Performance-Warranties
5
www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents found at www.kenall.com/patents. Content of specication sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
LTSIU_F-5445_091118
Loading...