LEGRAND F9018-BK, F9018-SR Instruction Manual

INSTRUCTION/INSTALLATION SHEET INTERCOM DESKTOP UNIT
301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
1. Introduction
The On-Q/Legrand Intercom Desktop Unit, PN F9018-xx (see Figure 1), provides a free standing expansion to the On-Q/Legrand Category 5 Intercom System. The unit is connected to the system via a 12’ Cat 5e jumper cable (provided). Typical applications will be a desktop in an office or on a nightstand.
2. Description
The Intercom Desktop Unit is functionally the same as the Category 5 Intercom Indoor/Room Unit (P/N F7637-xx).
3. Installation
Installation of the Desktop Unit may be accomplished at any time by connecting the unit (see Figure 2) with the supplied 12’ jumper cable to any Category 5 outlet which is wired back to the Intercom Module in the Enclosure.
At the Intercom Module, the connection from the Desktop Unit is treated just like any other Room Unit, and as such, plugged into one of the 12 available Room Unit jacks.
NOTE: Cat 5e termination may have to be accomplished at the outlet or in the enclosure. All terminations follow the T568A pin assignments. Refer to Figure 3 for correct T568A termination for both RJ45 plugs and 110 punchdown blocks.
Figure 3
Figure 1
IS-0328 REV. O
F9018-BK Black F9018-SR Silver
Insert jumper here
Figure 2
©Copyright 2005 by On-Q/Legrand All Rights Reserved.
INSTRUCTION/INSTALLATION SHEET INTERCOM DESKTOP UNIT
301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
4. Operation
Please refer to Figure 4 to familiarize yourself with the operation of the Desktop Unit.
TALK: Depressing this button will allow you to communicate with all other active units. Hold in the TALK button while speaking, and let it go when you are done. Your voice will be heard on the Main Console Unit, as well as any active Room or Desktop Unit within the system.
Figure 4
IS-0328 REV. O
ANSWER LED: This LED is located at the top of the
keypad of the Desktop Unit. When lit, the LED indicates that the microphone in the unit is active and anything you say will be communicated through the system. This LED will light when you are depressing the TALK or DOOR buttons. The LED will be constantly lit when the unit is in MONITOR mode.
DOOR: Depressing this button will allow you to communicate with all Door Units that are part of your system. Hold in the DOOR button while speaking and let it go when you are done. Your voice will be heard on any active Room or Desktop Units, the Main Console Unit, and all Door Units within the system.
MUTE: Press this button once to put the Unit in MUTE mode. Press the button again to return the Unit back to normal mode. While in MUTE mode, both the speaker and microphone of the unit will be inactive and the LED to the right of the MUTE button will glow red. MUTE mode is useful for maintaining privacy in a particular room. Multiple rooms can be in MUTE mode at the same time.
MONITOR: Press this button once to put the Unit in MONITOR mode. Press the button again to return the Unit back to normal mode. While in MONITOR mode, the microphone is constantly active, the speaker is disabled and any voice or noise within the room will be heard throughout the system. The LED to the right of the MONITOR button will glow green when in MONITOR mode. Multiple Units can be in MONITOR mode at the same time. This function is useful for baby monitoring or other types of situations which require any voice or noise in a room to be heard throughout the system.
VOLUME: There are two volume control keys with an associated volume level LED bar. There are 10 different volume levels which are adjusted up and down using these two buttons. Pressing the volume up button once will increase the volume one level higher. You may not see the LEDs change until you press the volume up or down multiple times (approximately every sixth button press). You can also hold in the volume up or down button until you have reached the desired volume level. It is recommended that you keep the volume level in the middle position (3 LEDs lit) for optimum sound quality
DOOR RELEASE: There is no specific button on the Unit for the DOOR RELEASE function. However, by depressing both the TALK and the DOOR buttons at the same time, the Unit will engage the door release device (not included with the Intercom System) if a door release device is installed in conjunction with the Intercom System. Once you let go of the TALK and DOOR buttons, the door release device will be disengaged, which will lock the door again.
©Copyright 2005 by On-Q/Legrand All Rights Reserved.