Evolution Series
Legrand/Wiremold electrical systems conform to and should be properly
grounded in compliance with requirements of the current National
Electrical Code or codes administered by local authorities.
All electrical products may present a possible shock or fire
hazard if improperly installed or used. Legrand/Wiremold electrical
products may bear the mark of a Nationally Recognized Testing
Laboratory (NRTL) and should be installed in conformance with current
local and/or the National Electrical Code.
™
Work Surface Portal
I N S T A L L A T I O N I N S T R U C T I O N S
Installation Instruction No.: 1 008 956 – December 2009
roducts: WS6F, WS6S, WS8F, WS8S
P
CAUTION: The 3-prong, grounding type plugs in all units are for use with 3-prong, grounded receptacles only.
SURFACE INSTALLATION:
Step 1. Using a jigsaw and the template provided, cut a
Modifying or bypassing the ground pin for use in a non-grounded receptacle may lead to electrical shock,
and voids the product warranty. All units are designed for interior use in dry locations only.
circular opening in the table.
WS6S – 6 1/4" [159mm] diameter
WS8S – 8 1/4" [210mm] diameter
IMPORTANT: Please read all instructions
before beginning.
Step 2. Insert Evolution Series Work Surface Portal into
opening in the table, and orient as desired.
FLUSH INSTALLATION:
Step 1. Using a router with a 1/2" [12.7mm] straight cutting bit
and a circle cutting jig, rout a circular pocket based on
the dimensions shown below.
WSF6
WSF8
6 1/4"
[159mm]
7 1/4"
[184mm]
8 1/4"
[210mm]
9 1/4"
[235mm]
5/32"
[4.0mm]
[4.0mm]
5/32"
FLUSH INSTALLATION (continued):
Step 2. Using a jigsaw, cut along the inside edge of the
routed recess to remove the center.
MOUNTING & WIRING (Flush & Surface Models):
Step 1. Insert mounting clip into slot that is appropriate for
the table thickness, and tighten thumb screw.
Accommodates table thicknesses between 3/4"
[19mm] and 3 1/4" [82mm].
Step 3. Insert Evolution Series Work Surface Portal into
opening in the table, and orient as desired.
Step 2. Install Extron Electronics MAAP devices (Not
provided) using screws provided with the devices.
Step 3. Make wiring connections to AV devices and data
connectors. Utilize the slots on the underside of the
Evolution Series Work Surface Portal to provide
strain relief for the cables.
Step 4. If additional protection for the work surface is
desired, apply adhesive-backed bumper to cover
in location indicated.