Technical data
047 71 604 770 604 772
Supply voltage: 230V 50/60Hz 120V 50/60Hz 24V AC/DC Consumption : ca. 1 W Contact rating: 2 changeover contact 16 A 250V~µ cos ϕ = 1 Parallel compensation 60VA max. 7µF Accuracy : ± 0,2 s /day under typical installation conditions
single strand multi strand
Terminal capacity: 1,5...4 mm
2
1,5...2,5 mm
2
Programmes: 28 per channel Battery reserve: 6 years Storage ambient: -20°C to +60°C Working ambient: -20°C to +55°C
Set language
Overview
General information
• Start-up: after applying the supply voltage, the time switch starts automatically with the last selected function. The relay position is set by the current program.
• Battery backup
- Backlighting not active
- Data key READ/WRITE only via the menu.
• For saftety, when the time switch is connected to the mains
supply the contact should not be used on an isolated low volta­ge supply and when the time switch is connected to the isola­ted voltage supply the contact should not be used on the mains supply.
Channel display
Day, Time, Date
Switch status of the cur rent channel
Function
Receptacle for
data key
1800W 1800W 1800W 2300W 100W 100W 1800W 2300W
+
+
Overview of programmed switching times for the week. Resolution 0.5h
C1
C2
Select menu, back to main menu, Hold down > 1s = operating display
Confirm selection or load parameters
• Select menu options or set parameters
• Channel selection
햷 햸 햹 햶
Time switch D22 - 2 Channel
047 71 / 604 770 / 604 772
®
Safety notes
The device may be installed and connected only by a qualified electrician. Incorrect installation and use may result in electric shock or in fires, possibly with fatal results! Do not attempt to open the device! Before installing the device, read the operating instructions and observe the requirements for the installation location. Use only original accessories with the device. All Legrand products may be opened and repaired only by specially trained Legrand employees.
Unauthorised opening or repair of the device will invalidate all rights with respect to liability, replacement and warranty claims.
Modes
Reset
Auto - Automatic operation
Constant ON
Constant OFF
Extra
The switch status imposed by the program is inverted (manual override). With the next effective switch command, the time switch resumes control of on/off switching.
Programming
MENU
OK
Set time/date, summertime/wintertime and holiday period
Holiday
After activation, the holiday program is executed between 0:00h on the start date and 24:00h on the end date (Constant ON/OFF). After the holiday program has run once, it must be reactivated.
Summertime: ± 1 hour Europe: Factory set. SPECIAL: The switchover to/from
summertime can be freely programmed by entering a start date and end date
and is then executed each year on the
same day of the week, e.g. Sunday.
A program consists of an ON time, OFF time and associated ON and OFF days. Programs with predefined on/off days (Mon to Sun, Mon to Fri and Sat and Sun): for these programs, you only need to set the switching times. With the "INDIVIDUAL” option, you can allocate switching times to specific days of your choice. The programs of a channel are linked to one another by logical OR.
Warning!
The memory will be cleared, and all set data will be lost.
Hold down all keys simultaneously for about 2 seconds and release. The language, time, date, summertime/wintertime and switching times will have to be re-entered.
Set MON and TUES as on/off days
*
*
CHRONO = All switch commands are executed in chronological order in a week INPUT = Programs are executed in the order in which they are entered
Additional function descriptions are provided on the attached sheet.