Electric, 2/3 Jacketed
Insulated Self-
Insulated for Safety™
Model
Deep Drawn Construction
Contained Kettle
Stationary, Floor Mounted
LTCRE
Made in USA
Standard Features
♦ The Legion 316L Kettle System
◊316L stainless liner
◊316 stainless draw-off tube and welds
◊316 stainless 1.5” compression draw-off
♦ 304 stainless kettle jacket
♦ Kettle protection system
◊ Thermostat temperature control, 150˚F - 260˚F
◊ Pressure relief valve, 30 psi maximum operating pressure
◊ Air eliminator valve
◊ Pressure gauge
◊ Jacket-water fill
◊ Automatic low water cut off and indicator light
◊ Field replaceable heating elements
♦ Full body insulation between kettle jacket and outer casing
♦ 304 stainless outer casing seam welded to radius lip
♦ 304 stainless, seam welded control console
♦304 stainless, one piece, domed cover
♦ Recirculating pump with automatic timer and manual control
♦ Graduated, break-resistant coee level sight glass
♦ Gridded riser basket with canvas coee bag and stainless spreader ring
♦ Bag removal hoist
♦ Water ll connection
Model LTCRE-60 shown with
custom dispensing faucet
Legion equipment is built to comply with applicable standards fo manufacturers. Approval agencies may include ASME, NSF, UL, ETL, AGA, CSA, CGA and
others. Legion reserves the right of design improvement or modication as warranted.
♦ Adjustable anged feet
Models and Capacities
LTCRE-40 40 gal. (151 l.)
LTCRE-60 60 gal. (227 l.)
LTCRE-80 80 gal. (303 l.)
LTCRE-100 100 gal. (379 l.)
Select Voltage: __208V __240V __380V __415V
__440V __480V
Select Phase: __1ф __3ф
Revision 1102
Prison/Security:
_Draw-o protection package Voltage ф Phase Amps H.P.
_Fasteners (screws & nuts)
_Nut driver tool 115 1 5.2 1/3
_Screw driver tool
_Lockable lid 220 1 3.2 1/3
_Lockable control cover
Other Options:
_Pressure switch
_Elevated draw-o faucet ” 208 3 1.4 1/3
_Water supply plumbing assembly
_Stainless mesh cloth coee lter 230 3 1.2 1/3
_Remote coee ll
Accessories:
_Draw-o drain with 6 foot hose
_Cloth coee bag insert with stainless spreader ring
_Care kit
Optional Features and Accessories
See price list for supplemental information regarding options
PUMP MOTOR OPTIONS
230 1 2.6 1/3
460 3 .6 1/3
Legion Industries, Inc., Post Ofce Box F, Dallas, PA 18612, (800) 833-9803, (570) 675-1595,
Fax: (570) 675-7551, www.legionindustries.com, sales@legionindustries.com

Model
LTCRE
Electric, 2/3 Jacketed
Insulated for Safety™
Deep Drawn Construction
Stationary, Floor Mounted
Made in USA
Insulated Self-
Contained Kettle
M O D E L LT C R E D I M E N S I O N S
Gal A B C D E F H J S T U W AA & BB
40 23.0 35.5 53.5 28.6 13.6 54.6 14.6 70.5 20.0 49.1 28.9 18.4 11.9
60 25.5 40.5 58.5 31.3 15.0 58.0 14.6 75.5 21.4 52.9 30.1 19.6 12.9
80 29.5 41.5 60.5 35.3 17.0 59.0 15.9 76.5 23.4 58.9 32.1 21.6 14.3
100 32.5 42.5 61.8 38.3 18.5 62.0 16.0 83.3 24.5 63.4 33.6 23.1 15.4
M O D E L LT C R E E L E C T R I C A L S P E C I F I C AT I O N S ( A m p e r e s p e r l e g )
Gal. kW
40 12.0 57.7 33.3 50.0 28.9 31.6 18.2 28.9 16.7 27.3 15.7 25.0 14.4
60 24.0 115.4 66.6 100.0 57.7 63.2 36.5 57.8 33.4 54.5 31.5 50.0 28.9
80 36.0 173.1 99.9 150.0 86.6 94.7 54.7 86.7 50.1 81.8 47.2 75.0 43.3
100 36.0 173.1 99.9 150.0 86.6 94.7 54.7 86.7 50.1 81.8 47.2 75.0 43.3
208 Volt 240 Volt 380 Volt 415 Volt 440 Volt 480 Volt
1ф 3ф 1ф 3ф 1ф 3ф 1ф 3ф 1ф 3ф 1ф 3ф
Revision 1102
Legion Industries, Inc., Post Ofce Box F, Dallas, PA 18612, (800) 833-9803, (570) 675-1595,
Fax: (570) 675-7551, www.legionindustries.com, sales@legionindustries.com