Legacy RMC-LC10NG, RMC-LC10LP, RMC-LC20NG, RMC-LC20NGF, RMC-LC20LP User's Operation And Installation Manual

...
INSTALLER / CONSUMER
SAFETY INFORMATION
Please read this manual before installing and using the heater.
WARNING:
If the infor
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier
from a neighbour’s phone. Follow the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer, service agency or the gas supplier.
Installer: Leave this manual with the heater.
Consumer: Retain this manual for futur
e r
efer
ence.
This is an unvented gas-fir
ed heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be pr
ovided. Refer to the
Installation section on page 3.
Unvented
Gas-Fired Room Heater
Blue Flame Heaters
Models: RMC-LC10NG, RMC-LC10LP - 10,000 Btu/hr.
RMC-LC20NG(F), RMC-LC20LP(F) - 20,000 Btu/hr RMC-LC30NG(F), RMC-LC30LP(F) - 30,000 Btu/hr
RMC-LC10NG(T), RMC-LC10LP(T) - 10,000 Btu/hr. RMC-LC20NG(T),(F), RMC-LC20LP(T),(F) - 20,000 Btu/hr RMC-LC30NG(T),(F), RMC-LC30LP(T),(F) - 30,000 Btu/hr
Infra-Red Heaters
Models:
RMC-LI10NG, RMC-LI10LP - 10,000 Btu/hr RMC-LI18NG(F), RMC-LI18LP(F) - 18,000 Btu/hr RMC-LI30NG(F),
RMC-LI30LP(F)
- 30,000 Btu/hr
RMC-LI06NG, RMC-LI06LP - 6,000 Btu/hr. RMC-LI10NG
(T)
, RMC-LI10LP
(T)
- 10,000 Btu/hr
RMC-LI18NG
(T),(F)
, RMC-LI18LP
(T),(F)
- 18,000 Btu/hr
RMC-LI30NG
(T),(F)
, RMC-LI30LP
(T),(F)
- 30,000 Btu/hr
User’s Operation and Installation Manual
(F)=Fan, (T)=Thermostat Gas Control
(F)=Fan, (T)=Thermostat Gas Control
07/05 Rev 3.
2
General Information
SAFETY: Accidents are always tragic especially because so many of them could have been prevented with a little care and attention. These are some basic good practices we hope you will follow for safe use of your gas fired room heater.
IMPOR
TANT: Read this user's manual carefully and completely before trying to assemble, operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock (fan models) or carbon monoxide poisoning.
Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol or those at high altitude.
Begin by ensuring proper installation and servicing. Ensure that your qualified technician who installs this heater follows the installa
tion instructions provided with this product.
Ha
ve the installer show you where the gas supply shut off valve is loca
ted so tha
t you kno
w where to shut off the gas to the
hea
ter
.
If the connections are not perfectly sealed or tightened, you may have a leak and therefore a faint gas smell.
F
inding a leak is NOT a do-it-yourself procedure. Some leaks can only be found with the main burner gas on and this must be done by a qualified technician.
Table of Contents
bathroom and an unvented room heater having an input rating of more than 6,000 BTU per hour shall not be installed in a bathroom.
• Do not install RMC-LC30,
LI30, LC20 or LI18 heaters in a
bedroom or a bathroom.
• Do not install RMC-LC10 or LI10 hea
ters in a bathroom, they
are allowed in bedrooms.
• LI06 heaters are allowed in bathrooms or bedrooms.
• This appliance is intended for supplemental heating.
• Do not use a blower or other accessory not approved for use with this heater.
• Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Keep flammable objects more than 36” from the front and top of the heaters and more than 10” from the sides of the heater ( 8”
for the L106 heater).
• Provide adequa
te clearances for accessibility for purposes of
servicing the heater.
• Maintain adequa
te clearances around the air openings to
allo
w for proper and safe operation of the heater.
WARNING: Do not allow fans to blow directly into the heater. Avoid any drafts that alter the burner flame patterns.
• This heater needs fresh, outside air for combustion to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air (oxygen content > 18%) is available.
• Never run heater in confined space. Refer to page 4.
• If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, clean it and have it serviced.
• Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
• Keep burner and control compartment clean. See maintenance section of this manual.
• Do not place clothing or other flammable material on or near the appliance.
• Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns and clothing ignition.
• Young children should be carefully supervised when they are in the same room with the appliance. Never allow them to sit, stand or play on or around the heater.
• Make sure tha
t if the safety screen or guard is removed for
ser
vicing or lighting the a
ppliance,
it is replaced prior to
operating the heater.
Do not use the hea
ter if an
y part has been under water.
Immedia
tely call a qualified ser
vice technician to inspect the room heater and to replace any part of the control system and an
y gas control which has been under wa
ter
.
The ODS pilot light safety system is designed to prevent asphyxiation due to a lack of oxygen in the air.
The hea
ter does not monitor the air for CO.
This appliance may be installed in an aftermarket, per
manently located,
manufactur
ed (mobile) home
,
wher
e not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Any c
hange to this heater or
its controls can be dangerous.
PRECAUTIONS
• Never use natural gas in a unit designed for propane gas.
• Never use propane in a unit designed for natural gas.
• Check all joints and connections.
T
o a
void the danger of fire, accident or explosion, never check a potential gas leak with an open flame.
An unvented room hea
ter ha
ving an input rating of more than
10,000 BTU per hour shall not be installed in a bedroom or
SAFE OPERATION OF YOUR LEGACY
VENT FREE HEATER
Installer / Consumer Safety Information . . . . 1
General information . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operating Instructions . . . . . . . . . . . . . . . . . 8
Troubleshooting . . . . . . . . . . . . . . . . . . . . . 10
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 11
Replacement Parts . . . . . . . . . . . . . . . . . . . 12
Accessories . . . . . . . . . . . . . . . . . . . . . . . . 14
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3
RMC-LCNG, RMC-LCLP, RMC-LING, RMC-LILP Specifications
Models
(Manual &
Thermostat)
Gas Type
Input Rating
(Btu/Hr) Variable
Regulator
Pressure
Setting
Inlet Gas Supply
Pressure
Size
of Heater
Weight
Min. Max Min. Max
RMC-LC30NG
Natural
15,000 30,000
4.0” w.c. 5.0” w.c. 11” w.c.
27”x24”x8
1/2
30 lbs.
RMC-LC20NG
10,000 20,000
19
3/8
”x22
7/8
”x8
1/2
22 lbs.
RMC-LC10NG
5,000 10,000
15
1/2
x20
7/8
x7
7/8
17 lbs.
RMC-LC30LP
LP
15,000 30,000
10” w.c. 11.0” w.c. 14.0” w.c.
27”
x24”x8
1/2
30 lbs.
RMC-LC20LP
10,000 20,000
19
3/8
”x22
7/8
”x8
1/2
22 lbs.
RMC-LC10LP
5,000 10,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI30NG
Natural
6,400 30,000
27”x24”x8
1/2
30 lbs.
RMC-LI18NG
6,400 18,000
19
3/8
”x22
7/8
”x8
1/2
22 lbs.
RMC-LI10NG
5,500 10,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI06NG
- 6,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI30LP
LP
6,400 30,000
10” w.c. 11.0” w.c. 14.0” w.c.
27”x24”x8
1/2
30 lbs.
RMC-LI18LP
6,400 18,00
19
3/8
”x22
7/
8
”x8
1/2
22 lbs.
RMC-LI10LP
5,500 10,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
RMC-LI06LP
- 6,000
15
1/2
”x20
7/8
”x7
7/8
17 lbs.
NOTE: For altitude above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level.
DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes,
use the la
test edition of the National
Fuel Gas Code
ANSI Z223.2,
also kno
wn as NFP
A54.
Available from: American Na
tional
Na
tional F
ire Protection
Standards Institute,
Inc.
Associa
tion,
Inc.
1430 Broadway
Batterymarch Park
New
Y
ork,
NY 10018
Quinc
y, MA 02269
RMC-LC30 / RMC-LC20 / RMC-LC10
RMC-LI30 / RMC-LI18 / RMC-LI10 / RMC-LI06
Certified to ANSI Z21.11.2b-2004 Unvented Heaters
This heater has a pilot with an Oxygen Depletion Sensor Shut­off system (ODS).
The ODS pilot is a required fea
ture for vent-
free hea
ters.
The ODS pilot shuts off the hea
ter if the normal air
oxygen content is reduced belo
w 18%.
This hea
ter has a piezo ignitor
.
This system requires no ma
tch
-
es,
ba
tteries or other electrical sources to light the heater.
PRODUCT FEATURES
SAFETY DEVICE
PIEZO IGNITION SYSTEM
4
Installation
• This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home.
Modern construction standards have resulted in homes that are highly energy efficient and that allow little heat loss. However, your home needs to breathe and all fuel burning appliances need fresh air to function properly and safely. Exhaust fans, clothes dryer, fireplaces and other fuel burning appliances all use the air inside the building. If the available fresh air supply is insufficient to meet the demands of these appliances, problems can result.
Confined Space:
The National fuel Gas Code, ANSI Z223.1 / NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space.
Unconfined Space:
An unconfined space is defined in the same standards as a space whose volume is not less than 50 cubic feet per 1000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
Example:
10,000 BTU Legacy heater should only be installed in a room whose volume is more than 500 cubic feet. A room that is 8' x 8' x 8' (512 cubic feet) would be acceptable for a Legacy 10,000 BTU/hour heater.
If an additional fuel fired appliance is installed in the same room,
the input ra
ting of tha
t a
ppliance should be added to
tha
t of the Legac
y hea
ter to determine the minimum sized
room that should be serviced by both appliances.
Unusually tight construction is defined as construction
where:
a) Walls and ceilings exposed to the outside atmosphere have a
continuous wa
ter va
pour retarder with a rating of 1 perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed;
b)
Weather stripping has been added on openable windows and doors; and
c) Caulking or sealants are applied to areas such as joints
around windo
w and door frames, between sole plates and
floors,
between wall-ceiling joints,
between wall panels,
a
t penetrations for plumbing, electrical and gas lines and at other openings.
PROVIDE ADEQUATE COMBUSTION
AND VENTILATION AIR
WARNING: If the area in which the heater may be operated is
smaller that that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventila
tion air by one of the methods described in the National fuel Gas code, ANSI Z223.1 / NFPA 54,
Section 5.3 or applicable local codes.
Verify the type of gas supply to be used, either natural gas or LP (Propane), and make sure the marking on the appliance rating plate agrees with that of the supply gas. The rating plate is located on the side of the heater, which indicates the type of gas the heater is manufactured for.
WARNING: This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases.
Before installing the heater, make sure you have these items:
• Gas piping (check local codes)
• Test gauge connection
• Sealant (resistant to LP gases) - approved thread compound
• Manual shut-off valve*
• Sediment trap - where required
• Ground joint union
• Tee joint and pipe wrench
*An installer supplied design-certified manual shut-off valve
with 1/8 NPT tap connection.
ITEMS NEEDED FOR
HEATER INSTALLATION
GAS TYPE
LOCATING THE HEATER
5
PREPARING FOR INSTALLATION
1. Remove heater from carton
2.
Remove all protective packa
ging applied to heater
for shipment.
3. Check heater for any shipping damage. If heater is dama
ged,
promptly inform dealer/distributor.
4.
Select a loca
tion for the hea
ter tha
t will provide maximum exposure of the radiant surface to the room, but will not be subjected to accidental contact.
5.
Adequa
te c
learance must be a
vailable around the air open
­ing. Refer to Figure 2 for clearances that must be main­tained to the side walls,
floor and horizontal surface sur-
rounding the hea
ter
.
Fig. 2 Minimum clearances from mounting holes to top surface of flooring,
adjacent walls and ceiling
ATTACH MOUNTING SCREWS TO WALL
Fig.
3
Use pa
per templa
te supplied to mark loca
tion of mounting holes.
Be sure templa
te is level.
NOTE: Wall anchors and mounting screws are in hardware
package provided with heater.
1. Install mounting screws on wall as shown in Figure 3. Use enclosed paper template for proper location of holes. Be sure template is level. It may be necessary to use plastic or lead anchors for plaster walls.
2. Drill holes at marked location using 9/64” drill bit. Insert mounting screws.
3. Leave screw head out from wall far enough to attach heater.
• Due to high tempera
tures, the appliance should be located out of traffic and away from furniture and draperies. Keep flam­mable objects more than 36” from the front and top of the heaters and more than 10” from the sides of the heater.
• Provide adequate clearances for accessibility for purposes of ser
vicing the heater.
• Maintain adequate clearances around the air openings to allow for proper and safe operation of the heater.
WARNING: Do not allow fans to blow directly into the heater.
Avoid any drafts that alter the burner flame patterns.
This heater is designed to be mounted on a wall or on the floor.
WARNING: Never install the heater;
• in a bathroom*
• in a recreational vehicle
• where curtains, furniture, clothing or other flammable are less than 36” from the front, top or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
*Models RMC-L106NG or LP Permitted for bathroom installation.
WARNING: Vent-free heaters add moisture to the air. Although
this is beneficial, installing heater in rooms without enough ventilation may cause mildew formation from too much moisture content. See National Fuel Code for Fresh Air for Combustion and Ventilation.
This appliance may be installed in an aftermarket, permanently located manufactured (mobile) home, were not prohibited by state or local codes.
Caution: If you install the heater in a home garage:
• Heater must be at least 18” above floor
• Locate heater where moving vehicle will not hit it.
• Install to
ANSI Z223.2 / NFPA 54 using fixed gas supply piping.