Legacy HERYTAGE H2kVA, HERYTAGE H3kVA, HERYTAGE H4kVA Configuration Manuals

HERYTAGE™
H2kVA, H3kVA and H4kVA
Configuration Guide
LPC-22004 Rev C 12/04/07
HERYTAGE H2kVA, H3kVA, and H4kVA Configuration Guide
The HERYTAGE order number is determined by the configuration or options selected. This guide will assist in configuring the product and determining the list price. The resulting order number should be 15 digits in length. Example Order Number: H02AB00AC3K3A0A
The digits in the order number designate the following:
Digits 1-5 - The kVA rating, input voltage and output voltage of the UPS. Digit 6 - Battery configuration (internal, external, or less battery). Digit 7 - Bypass option. Currently only external bypass is allowed. Digit 8 - Input Connection Digit 9-14 - Output connect, receptacle type and quantity Digit 15 - Other options
Items that are not directly attached to the UPS from the factory, such as external maintenance bypass switches and battery packs, will need to be ordered as a separate line item and are shown under the External Accessories section .
Base Model (Digits 1 - 5)
KVA Rating Input Voltage Output Voltage Order Code List Price
120 Out H02AA $2,950
120 In
120/208Out H02AB $2,950
2kVA
3kVA
4kVA
208 In
240 In
120 In
208 In
240 In
120 In
208 In
240 In
120/240 Out H02AC $2,950
120 / 208 Out H02BB $2,950
120 / 240 Out H02BC $2,950
120 / 208 Out H02CB $2,950
120 / 240Out H02CC $2,950
120 Out H03AA $3,286
120/208Out H03AB
120/240 Out H03AC
120 / 208 Out H03BB
120 / 240 Out H03BC
120 / 208 Out H03CB
120 / 240Out H03CC
$3,286
$3,286
$3,286
$3,286
$3,286
$3,286
120 Out H04AA $4,200
120/208Out H04AB $4,200
120/240 Out H04AC
120 / 208 Out H04BB
120 / 240 Out H04BC
120 / 208 Out H04CB
120 / 240Out H04CC
$4,200
$4,200
$4,200
$4,200
$4,200
Product and Prices subject to change without notice. All Prices F.O.B. Necedah, WI, USA in U.S. dollars
Legacy Power Conversion, Suite 7, N9246 Hwy 80 South, Necedah, WI 54646 800-859-5877
HERYTAGE H2kVA, H3kVA, and H4kVA Configuration Guide
Battery Options (Digit 6)
KVA Rating Battery Option Charger Order Code Price
11 minute Internal Battery, (4) BAT-0373 Standard 0 $850
32 minute Internal Battery, (4) BBAT-0065 Standard 1 $950
2kVA
3kVA
4kVA
84 minute Internal Battery, (4) BBAT-10032 Standard 8 $1,400
186 minute Internal Battery, (8) BBAT-10032 Standard 9 $2,700
Set up for External Battery Standard 2 $0
Set up for Internal Battery/ Less Battery Standard 4 $470
18 minute Internal Battery, (4) BBAT-0065 Standard 0 $950
50 minute Internal Battery, (4) BBAT-10032 Standard 1 $1,400
116 minute Internal Battery, (8) BBAT-10032 Standard 9 $2,700
Set up for External Battery Standard 2 $0
Set up for Internal Battery/ Less Battery Standard 4 $470
11 minute Internal Battery, (4) BBAT-0065 Standard 0 $950
34 minute Internal Battery, (4) BBAT-10032 Standard 1 $1,400
85 minute Internal Battery, (8) BBAT-10032 Standard 9 $2,700
Set up for External Battery Standard 2 $0
Set up for Internal Battery/ Less Battery Standard 4 $470
Bypass Options (Digit 7)
Bypass Option Order Code Price
No Internal Bypass 0 $0
Input Connection Options (Digit 8)
KVA Rating Input Connection Option Input Voltage Required Order Code Price
2kVA - 4kVA Hardwired Any A $0
2kVA NEMA 5-20 120 C $60
2kVA NEMA L5-20 120 I $60
2kVA – 3kVA NEMA L5-30 120 J $60
2kVA – 4kVA NEMA 5-50 120 E $90
2kVA – 3kVA NEMA 6-15 208 or 240 O $60
2kVA – 3kVA NEMA L6-20 208 or 240 K $60
2kVA – 4kVA NEMA L6-30 208 or 240 L $60
Product and Prices subject to change without notice. All Prices F.O.B. Necedah, WI, USA in U.S. dollars
Legacy Power Conversion, Suite 7, N9246 Hwy 80 South, Necedah, WI 54646 800-859-5877
HERYTAGE H2kVA, H3kVA, and H4kVA Configuration Guide
Output Connection Options (Digit 9-14)
Output Connections are specified by three sets of 2 digits (9-10, 11-12, 13-14). Each set is used to specify a type of receptacle and the quantity of that type. If hardwired output is desired, all sets should be A0 (A0A0A0).
The receptacles should be specified alphabetically by the order code. Unneeded sets should remain A0. If a quantity of two (2) NEMA 5-20 and one (1) NEMA L6-30 receptacles are desired the digits should be C2K1A0. A total quantity of three (3) receptacles can be specified.
Output Connection Option Output Voltage Required Order Code Price Ea.
Hardwired Any A $0
NEMA 5-15 120 B $50
NEMA 5-20 120 C $50
NEMA L5-15 120 D $75
NEMA L5-20 120 E $75
NEMA L5-30 120 F $75
NEMA 6-15 208 or 240 G $75
NEMA 6-20 208 or 240 H $75
NEMA L6-15 208 or 240 I $75
NEMA L6-20 208 or 240 J $75
NEMA L6-30 208 or 240 K $75
Other Internal Options (Digit 15)
Other Options Order Code Price
No Other Options A $0
Neutral to Ground Bond Removal (for Shipboard Applications) B $25
Internal Modem Option M $245
Product and Prices subject to change without notice. All Prices F.O.B. Necedah, WI, USA in U.S. dollars
Legacy Power Conversion, Suite 7, N9246 Hwy 80 South, Necedah, WI 54646 800-859-5877
HERYTAGE H2kVA, H3kVA, and H4kVA Configuration Guide
External Accessories
External options, such as maintenance bypass switches and battery packs must be ordered as a separate line item.
External Maintenance Bypass Switches
Part Number Description UPS Output Voltage Price1
SW040BBMA
SW040BBMC
SW040BBML
SW040MBBA
SW040MBBC
SW040MBBL
1
. Use discounting structure of Herytage 6kVA for external bypass switches.
40 Amp Break-Before-Make with AC Disconnect, Wall Mounted
40 Amp Break-Before-Make with AC Disconnect and Aux. contacts, Wall Mounted
40 Amp Break-Before-Make with AC Disconnect and Lock Option, Wall Mounted
40 Amp Make-Before-Break with AC Disconnect, Wall Mounted
40 Amp Make-Before-Break with AC Disconnect and Aux. contacts, Wall Mounted
40 Amp Make-Before-Break with AC Disconnect and Lock Option, Wall Mounted
Any $600
Any $620
Any $860
120 or 120/240 $750
120 or 120/240 $770
120 or 120/240 $1010
External Battery Packs and Accessories
Part Number Description Price
BP048A1100
BP048B1100
BP00000100
MBAC-10113 3 FT. Battery Cable Extension $60
BAT-0373 NP18-12BFR battery Call
BBAT-0065 12 volt, 33 amp-hour battery Call
BBAT-10032 UPS12-300MR, 12 volt, 300 WPC. Replaces BBAT-0103 Call
Battery Pack for 4kVA system. Includes battery cabinet, (4) BBAT-0065 batteries, cables. Can be daisy chained for additional runtime.
Battery Pack for 4kVA system. Includes battery cabinet, (4) BBAT-10032 batteries, and cables. Can be daisy chained for additional runtime.
Battery Cabinet with cables for 2kVA, 3kVA, and 4kVA. Does not include batteries.
$950
$1,400
$485
External Communication Options
Part Number Description Price1
SNMP-10002 SNMP Adapter with cables $400
CIFK-10001 AS/400 Cable $180
SFWR-10001 UPS Management Software for Windows $99
SFWR-10002 UPS Management Software for Unix $250
1
. Use discounting structure of Herytage 6kVA for external communication options.
Product and Prices subject to change without notice. All Prices F.O.B. Necedah, WI, USA in U.S. dollars
Legacy Power Conversion, Suite 7, N9246 Hwy 80 South, Necedah, WI 54646 800-859-5877
HERYTAGE H2kVA, H3kVA, and H4kVA Configuration Guide
Battery Information
Runtime Chart
Battery Option 100% Load 75% Load 50% Load 25% Load
11 minute Internal, (4) BAT-0373 11m 18m 32m 1h17m
32 minute Internal, (4) BBAT-0065 32m 47m 1h17m 2h44m
2kVA
84 minute Internal, (4) BBAT-10032 1h24m 1h56m 3h06m 7h07m
186 minute Internal, (8) BBAT-10032 3h06m 4h22m 7h07m 15h39m
18 minute Internal, (4) BBAT-0065 18m 27m 47m 1h44m
3kVA
4kVA
50 minute Internal, (4) BBAT-10032 50m 1h12m 1h56m 4h22m
116 minute Internal, (8) BBAT-10032 1h56m 2h41m 4h22m 10h09m
11 minute Internal, (4) BBAT-0065 11m 18m 32m 1h17m
34 minute Internal, (4) BBAT-10032 34m 50m 1h23m 3h06m
85 minute Internal, (8) BBAT-10032 1h25m 1h56m 3h06m 7h07m
Product and Prices subject to change without notice. All Prices F.O.B. Necedah, WI, USA in U.S. dollars
Legacy Power Conversion, Suite 7, N9246 Hwy 80 South, Necedah, WI 54646 800-859-5877
Loading...