Lefroy Brooks X1-2010 Installation, Operating And Maintanance Instructions

Page 1
INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS
X1-2010
CROSS HANDLE THERMOSTATIC WITH ZU LEVER FLOW CONTROL TRIM ONLY, TO SUIT M1-4201 ROUGH
Page 2
2
Contents
InstalLation Procedure 4
Page 3
8 3/8"
5 11/16"
2 13/16"2 5/8"
1 5/8"
2 3/16"
1 1/16"
45°
7/8"
1 15/16"
3/16"
9/16"
1 7/16"~3 1/16"
(212.5mm)
(145mm)
(72mm)(67mm)
(42mm)
(55mm)
(27.5mm)
(22.2mm)
(49mm)
(4.5mm)
(15mm)
(37~78.5mm)
3
Dimensions in Inches (& Millimetres)
Whilst every effort is made to ensure accuracy, design and dimensions are subject to change without notice as part of the company’s product development process.
Page 4
4
2
1
Marble wall
3 1/8 - 4 1/8”
80-105
3
5 3/8"~5 1/2"
(136mm~140mm)
1 3/8"~1 5/8"
(35mm~42mm)
2 5/8"
(67mm)
3 9/16"~4 1/8"
(90mm~105mm)
4
Steps 1-4
Installation Procedure
Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation.
1
Before installing the valve into the wall, please note that a distance between 3 1/8”~ 4 1/8”
(80mm ~ 105mm) from the wall surface to the back of valve should be left, so that it can fit the trim kit.
2
Install valve assembly into the wall.
3
Cut a hole on the wall surface for fitting the trim kit. The hole dimension should be as shown.
4
Throw away the protective caps only when the building construction is completed and you are
ready to fit the trim.
Page 5
7
8
5
6
5
Installation Procedure
Steps 5-8
Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation.
5
Take out the stopper.
6
Turn on the flow controller. Turn the thermostatic cartridge till you get the water temperature at
38°. Suggestion: attach a hose to the outlets and guide the water tothe basin or another container to test the temperature and prevent it from spilling on the floor.
7
Turn off the water supply. Install the stopper and make sure its “B” plane, as shown, is horizontal
and on the left side.
8
Fix the stem extension and the adjusting ring.
Page 6
9
10
11
12
Set screw
Horizontal
6
Installation Procedure
Steps 9-12
Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation.
9
Install the canopies.
10
Fix the front plate with screws.
11
Fix the canopy with screw. When it is fixed, ensure the temperature-limit-button is in the
horizontal position. Turn clockwise to increase the temperature and turn counter- clockwise to reduce the temperature.
12
Install handle assembly with set screws.
Page 7
1 Screw (008772) 2 Cross handle (069910) 3 Screw (008994) 4 Adaptor (018210) 5 O-ring (048060) 6 Set screw (065086) 7 Canopy (071437) 8 Adjusting ring (104295) 9 Front panel (006596)
10 Seal (013218) 11 Plug (028008) 12 Handle seat (215479) 13 Button (036272) 14 Spring (005157) 15 Pin (003147) 16 Handle stem (108926) 17 Handle sleeve (038104) 18 Adaptor (205469)
19 Screw (008255) 20 Screw (008186) 21 Extension stem (110438) 22 O-ring (048085N) 23 Sleeve (041817) 24 Allen key (031003) 25 Allen key (031220)
8
7
13
6
4
1
3
2
12
23
21
16
17
14
15
20
24
10
5
18
19
9
22
25
11
7
Parts List
Exploded view
Page 8
8
Fault Finder
Fault Cause Rectification
Wobbling of handle. The fixing screw comes loose. Check for fixing screw and
re-tighten it properly.
Wobbling of canopy. The canopy comes loose. Check and tighten the canopy.
Page 9
9
Safety Tips, Care and Maintenance
Safety Tips
If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to applying flame, otherwise you will void the warranty.
Cover drain openings to avoid losing small parts.
When cutting or soldering pipe, use safety glasses to protect your eyes.
Important Points
Prior to beginning installation. turn off the cold and hot water lines and open the old faucet to release built-up pressure.
Overtightening nuts may cause damage.
Wrap all threaded connections with pipe tape available at your local plumbing supply store. Always wrap in a clockwise direction. The fittings should be installed by a state-licenced plumber.
Please note: When there is a difference in water pressure between hot and cold supplies to the mixing valve, the pressures should be equalized by a plumber in accordance with best practice and legislation.
Maintenance
Your new bathroom faucet is designed for years of trouble-free performance. Keep it looking new by cleaning it periodically with a soft cloth. Avoid abrasive cleaners, wire wool and harsh chemicals as these will dull the finish and void your warranty.
Routine Maintenance
The frequency and extent of attention required will vary according to prevailing site and operational conditions, however a 12 monthly maintenance schedule is recommended.
If the product has operated satisfactorily for some time, but performance has been degraded, please check the Fault Finder section to identify the problem.
Maintenance Check List
 s 7ORNORDAMAGEDSEALSANDWASHERS  s $AMAGEDSEALFACES  s 4HREADWEAR  s )NCORRECTADJUSTMENT  s #OMPONENTFAILURE  s $EBRISORLIMESCALEBUILDUP
Page 10
10
Guarantee
Guarantee of Quality
This product is guaranteed against faulty materials and workmanship for 12 months from date of purchase. For the guarantee to be valid, the unit must be installed by a competent person, in accordance with the instruction booklet.
Any part found to be defective during the guarantee period, will (at our option) be repaired or replaced, free of charge, provided the unit has been installed, and properly used in accordance with the instruction booklet.
Our products correspond to the valid technical and water supply standards as well as the relevant approvals requirements. We guarantee them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliabl
y.
Guarantee period
sThe guarantee is valid in private homes for 5 years from the purchase date. Proof of purchase
has to be provided when making a guarantee claim.
s By use in commercial or institutional applications the guarantee is valid for 1 year after first use.
To make a guarantee claim, proof of purchase or, the beginning of use is required.
Not Covered by this Guarantee
Damage or defects arising from incorrect installation, improper use or lack of maintenance. Installed product damaged in transit Consequential loss, damage or product removal and installation costs.
Lefroy Brooks is not responsible for any on site labour charges.
Page 11
The use of trademarks, product design and artwork is subject to licence or agreement with Christo A. Lefroy Brooks. The design
registrations, trademark registrations and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibited.
The right to modify designs and dimensions is reserved. Christo Lefroy Brooks is a member of ACID (Anti Copying in Design).
LEFROY BROOKS INC, 1828 TROUTMAN STREET, RIDGEWOOD, NY, 11385
TELEPHONE: 718-302-5292. FAX: 718-302-4177
COPYRIGHT©LBIP LTD 2013
718-302-5292
www.lefroybrooks.com
Loading...