Leeson 132426.00 Product Information Packet

Page 1
PRODUCT INFORMATION PACKET
Model No: C182T34DC111A
Catalog No: 132426.00
..5HP..3600RPM.184TC.ODP.230/460V.3PH.60HZ.CONT.40C.1.15SF.C FACE......GENERAL
PURPOSE........
Open Drip Proof (ODP)
Regal and Leeson are trademarks of Regal Beloit Corporation or one of its affiliated companies.
©2018 Regal Beloit Corporation, All Rights Reserved. MC017097E
Page 2
Product Information Packet: Model No: C182T34DC111A, Catalog No:132426.00
..5HP..3600RPM.184TC.ODP.230/460V.3PH.60HZ.CONT.40C.1.15SF.C FACE......GENERAL PURPOSE........
Nameplate Specifications
Output HP Frequency 60 Hz Voltage 230/460 V Current Service Factor Efficiency 86.5 % Duty Continuous Insulation Class KVA Code J Frame 182TC Enclosure Drip Proof Overload Protector No Ambient Temperature Opp Drive End Bearing Size 6205 UL Recognized CSA IP Code
5 Hp
12.4/6.2 A
1.15
F
40 °C
Y 22
Output KW
Speed Phase
Design Code
Drive End Bearing Size
CE
3.7 kW
3500 rpm 3
B
6206
Y
Technical Specifications
Electrical Type Poles 2 Rotation Reversible
Squirrel Cage Induction Run
Starting Method
Across The Line
Mounting Drive End Bearing BALL Opp Drive End Bearing BALL Frame Material Rolled Steel Shaft Type T Overall Length Shaft Diameter 1.125 in Shaft Extension 2.75 in Assembly/Box Mounting Outline Drawing
Round
13.20 in
F1/F2 CAPABLE 035344-900
Motor Orientation
Frame Length
Connection Diagram
HORIZONTAL
9.00 in
005010.01
This is an uncontrolled document once printed or downloaded and is subject to change without notice. Date Created: 10/15/2018
Page 3
RBC PROPRIETARY AND CONFIDENTIAL INFORMATION This document is the property of REGAL BELOIT CORPORATION ("RBC") including its subsidiaries and divisions and contains proprietary information of RBC. This document is loaned on the express condition that neither it nor the information contained therein shall be disclosed to others without the express written consent of RBC, and that the information shall be used by the recipient only as approved expressly by RBC. This document shall be returned to RBC upon its request. This document may be subject to certain restrictions under U.S. export control laws and regulations.
"C"
LIFT WARNING
.06
NAMEPLATE
WARNING
"AD"
EFF. or WATTSVR.
8.39
(3)
1.13
KNOCKOUTS
DASH
NO. 850 12.70 7.88
"C" "AD"
900 13.20 8.38
950 13.70 8.88 1000 14.20 9.38 1050 14.70 9.88 1100 15.20 10.38 1150 15.70 10.88
.15
2.90
2.750
2.63.27
1.78
FULL
DEPTH
1.1250
1.1245
GASKETS THROUGHOUT MAXIMUM FACE RUNOUT TO BE .004 T.I.R. MAXIMUM PILOT ECCENTRICITY TO BE .004 T.I.R. PERMISSIBLE SHAFT RUNOUT TO BE .002 T.I.R.
- UPDATED & REDRAWN TO SOLIDWORKS LST 12/17/2009 XX
NO
.25 SQ. X 1.75 KEY
REVISION
THIRD ANGLE PROJECTION
8.500
8.497
DECAL­CONNECTION UNDER COVER WHEN REQ'D.
(4) 1/2-13 UNC-2B X .75 DEEP ON A 7.250 B.C.
BY & DATE
RFP NETWORK FILE NAME
UNLESS SPECIFIED
DEC .X .XX .XXX .XXXX ANG
CHK
6.64
TOLERANCES
INCHES ±.1 ±.03 ±.005 ±.0005 ±1/2°
5.32
45°
TITLE
OUTLINE - 180TC FRAME DRIP PROOF - "C" FACE
MAT'L FINISH PREV
45°
1.67 REF.
DRAWN
RDW 7/22/97
CHK
PG 7/28/97
APPR SCALE
1:2
REF
035326
FMF
OF
PAGE
B
035344
REVSIZE DRAWING NO
-
12/18/2009 10:13:22 AM
Page 4
Uncontrolled Copy
Page 5
Date:
Speed (RPM)
Data Sheet
Current (Amps)
E
0.0
0 500 1000 1500 2000 2500 3000 3500 4000
5.0
10.0
TORQU
15.0
20.0
25.0
30.0
30.0
40.0
50.0
60.0
70.0
80.0
0% 20% 40% 60 % 80% 100% 120% 140%
F
100.0
90.0
E
F
F
P
Torque (ft-lb)
Efficiency (%) P.F. (%) Current (Amps)
45.5 41.0 28.9 6.2 2.50 5.0
16.1 14.5 25.0 7.5 0.00 3600 0 1800 2900 3500 3600
P.F. (%)
3600 3576 3552 3526 3500 3,478 3465 0
2.50 2.90 3.8 5.0 6.2 7.2 7.8 45.5
0.00 1.80 3.7 5.6 7.5 8.7 9.5 16.1
13.0 52.8 73.0 82.0 86.0 87.8 88.7 55.5
LR Pull-Up BD Rated Idle
1/29/2018 132426.00
Load 0% 25% 50% 75% 100% 115% 125% LR
Current (Amps)
Torque (ft-lb)
RPM
Efficiency (%)
Motor Speed Data
LOAD
Torque Amps
76.8 84.6 86.5 86.5 85.9 85.2
Uncontrolled Copy
Speed -Torque Curve
Motor Load Data
RPM
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
A
M
P
S
0
0
1.3270 1.2190 3.0560 1.6670 97.8640
R1 R2 X1 X2 Xm
EQUIV CKT (OHMS / PHASE)
Outline Dwg 035344-900
Conn. Diag 005010.01
Additional Specifications:
Ref Wdg
Sound Pressure @ 1M
VFD Rating
NONE
Rotor/Shaft wk²
Ambient
Elevation
T82117 R1
1,000
0.18
71 dBA
40
LR Code letter
Service Factor
Temp Rise @ FL
Duty
CONT
1.15
30
J
Voltage
Frequency
Design
Construction
HP
Sync. RPM
Frame
Enclosure
Information Block
230/460#190/380
TDW
182
60
B
DP
Data @
feet
Lb-Ft²
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
A
M
P
S
°
°
C
C
Hz
V
460
v
5 of 5