Model No: M4C17DJ18H
Catalog No: 100046.00
3/4HP..1725RPM.48.DP.115/208-230V.1PH.60HZ.CONT.MANUAL.40C.1.25SF.RESILIENT BASE.
Open Drip Proof (ODP)
Regal and Leeson are trademarks of Regal Beloit Corporation or one of its affiliated companies.
©2019 Regal Beloit Corporation, All Rights Reserved. MC017097E
1 of 5
Page 2
Nameplate Specifications
Output HP Frequency 60 Hz Voltage 115/208-230 V Current Service Factor Efficiency 70 % Duty Continuous Insulation Class KVA Code K Frame S56 Enclosure Drip Proof Overload Protector Manual Ambient Temperature Opp Drive End Bearing Size 6203 UL Recognized CSA IP Code
0.75 Hp
10.8/5.3-5.4 A
1.25
B
40 °C
Y 22
Output KW
Speed Phase
Design Code
Drive End Bearing Size
CE
0.56 kW
1725 rpm 1
N
6203
N
Technical Specifications
Electrical Type Poles 4 Rotation Selective Counterclockwise
Capacitor Start Induction Run
Starting Method
Across The Line
Mounting Drive End Bearing BALL Opp Drive End Bearing BALL Frame Material Rolled Steel Shaft Type NEMA 56 Overall Length Shaft Diameter 0.625 in Shaft Extension 1.88 in Assembly/Box Mounting Outline Drawing
Resilient Base
11.81 in
F1 ONLY 031641-700
Motor Orientation
Frame Length
Connection Diagram
HORIZONTAL
7.00 in
005003.52
This is an uncontrolled document once printed or downloaded and is subject to change without notice. Date Created: 02/14/2019
2 of 5
Page 3
Uncontrolled Copy
3 of 5
Page 4
Uncontrolled Copy
4 of 5
Page 5
HZ
3/22/2018
1780
1780
Uncontrolled Copy
LEESON ELECTRIC CORPORATION
TYPICAL PERFORMANCE CURVE for AC MOTOR
Curve at 230 Volts HP 0.76
60 HZ
Model No 100046.00 0.75 HP VOLTS 115/208-230
1
Catalog No 100046.00
60 70 80 90 100
EFF
60 70 80 90 100
PF
HP
60 RPM 1725
Eff
−−
PF
−−
HP
−−
RPM
−−
KW
−−
Amps
−−
1790 1800 1810 1820
0.6 0.7 0.8 0.9 1
RPM
1.2 1.4 1.6 1.8 2
KW
1790 1800 1810 18201.2 1.4 1.6 1.8 26 7 8 9 10
60 70 80 90 10060 70 80 90 1000.6 0.7 0.8 0.9 1
PF
HP
KW
EFF
RPM
AMPS
0 10 20 30 40 50
0 10 20 30 40 50
0 5 10 15 20 25 30 35 40 45 50
FL TORQUE 36 Oz.Ft FL AMPS 10.8/5.3-5.4 BD TORQUE 83.6 Oz.Ft PU TORQUE 82.4 Oz.Ft LR TORQUE 114 Oz.Ft LR AMPS 27.3 WINDING CE484207-3 Date
0 0.1 0.2 0.3 0.4 0.5
0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
0 0.2 0.4 0.6 0.8 1
1720 1730 1740 1750 1760 1770
0 5 10 15 20 25 30 35 40 45 50
Torque
0 10 20 30 40 50
0 10 20 30 40 50
0 0.1 0.2 0.3 0.4 0.5
0 0.2 0.4 0.6 0.8 1
0 1 2 3 4 5
1720 1730 1740 1750 1760 1770
0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
0 5 10 15 20 25 30 35 40 45 50
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque in Oz.Ft