LEEDARSON Motion sensor Pet immunity_Z-Wave
We build your success in IoT.

2
Motion Sensor Pet immunity
Quick Start Guide
1. Product Introduction
The Motion Sensor lets you know when movement is detected in a certain area and can trigger different
actions in response to that movement (or lack of movement). It supports the pet immunity up to 80 lbs.
This sensor integrated Z-Wave communication module to connect with Z-Wave gateway, and this device can
be adapted to EU(868.42Mhz) or US(908.42MHz).
If you want your Motion Sensor to be a security device that use secure/encrypted message to
communicate in a Z-Wave network, then a security enabled Z-Wave controller is needed.
The motion sensor can be included and operated in any Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other applications. All non -battery operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of the network.
2. Product Appearance
Product appearance and function overview.
LED

3
Bracket
Reset bu tton
Button:
Short press reset button into learning mode, then the sensor can inclusion or exclusion from the Z-
Wave network.
Hold the key for 5s to reset the sensor, after reset, Sensor will send “Device_Reset_Locally” to the
main controller and exclude from the Z-Wave network when the Button is released, this procedure
will reset the Sensor to factory default.
Short press button for 3 times then the sensor sending wake up notification to gateway,
and LED will fast blink when sending data, send over then the LED turn off..

6.23 ft. to 7.55 ft.
(1.9m to 2.3m)
20 lux for
day/night(bright/dark)
Z-Wave
908.42MHz (US)
868.42MHz(EU),
868.40MHz,868.42MHz, 869.85MHz
921.42MHz (AU)

5
3. Features/Capabilities:
Supports pet immunity up to 80 lbs (36 kgs)
Use PIR & Fresnel lens technology
Easy installation with bracket
Low battery alarm
Equipped with an anti-tamper switch that reports any tampering
4. Installation Position and Notes
1. Installation position should be chosen at the area which the bass-by will be across, try to make the bass-
by in the detection area as below.

6
Side view
Top view
2. Do avoid installation near air-conditioner, electric fans, refrigerators, ovens or other places where
temperature easy change.
3. In order not to affect the detecting result, there should be no object in front of the produces lens.
4. Building (such as the wall) will shorten the distance of wireless communication.
5. This device can be mounted on the wall only, it cannot be installed on the ceiling.
5. Product Installation
Adding the device as accessories, install it according to the diagram below:
① Choose the installation location on the wall, fix the bracket by screw or 3M adhesion tape on the
wall.
② Take off the bracket in the back, and draw out the battery insulation sheet, then assembly the
bracket.
③ Assembly the main body to the bracket.

7
6. Product Usage
Function of Action Button:
6.1 All functions of each trigger:
Function Of Action
In the network: Send Battery report and Wake up notification, the LED
turn on within 1 second.
Not in the network: Only the LED turn on within 5 second.
Short press
button one time
Add the Motion Sensor into the Z-Wave network:
1. Power on your Motion Sensor, and let your Z-Wave controller into
add/inclusion mode.
2. Implement the button action, the Motion Sensor will send out a node
info security CC in command class list (Security inclusion), the LED
will be fast blink for 60 seconds.
3. If the inclusion is successful, the LED will be turn on within 2
seconds. If failed, LED will be turn off forever, and please repeat the
steps in above.
Remove Motion Sensor from a Z-Wave network:
1. Power on your Motion Sensor, and let the Z-Wave primary controller
into remove mode.
2. Press the button on the Motion Sensor, the LED will be turn on for 60
seconds.
3. If Motion Sensor has been successfully removed from your Z-Wave
network, the LED will be fast blink 2 seconds. If failed, LED will be
turn off forever, and please repeat the steps in above.
Short press
button three time
In the network: Send Wake up notification, and LED will fast blink when
sending data, send over then the LED turn off.
Press and hold
more than 5
seconds
Reset Motion Sensor to factory default.
NOTE:
1. Triggering this action, in 5 seconds LED will be fast blink. The LED
will be turn on within 2 second until hold time is equal to 5 seconds.
Motion Sensor will send “Device_Reset_Locally” to the main
controller and exclude from the Z-Wave network when the button is
released, this procedure will reset the sensor to factory default.
2. Please use this procedure only when the network primary controller
is missing or otherwise inoperable.
3. When not in the network, ignore this operation.

In the network: Send Notification report and Sensor multilevel report
and Basic set (Setup configuration parameter 0x0E to 0x01), and the
LED will be blink 0.5 second.
Tamper switch is
triggered
In the network: Send Notification report, and the LED will be blink 0.5
second.
Not in the network: Only the LED will be blink 0.5 second.
6.2 Caution:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Hereby, Corporation declares that this device is in compliance with the essential requir ements and other
relevant provisions of Directive 2014/53/EU
6.3 Low voltage alarm to remind changing battery.
This product has low voltage detection reminder, when the battery voltage is in low status, the
detector will give out low battery signal to controller.
6.4 Z-Wave command.
Special Rule Of Each Command Class
Z-Wa ve Plus Info Report Command Class
0x06
(ZWAVEPLUS_INFO_RE PORT_ROLE_TY PE_SLAV E_SLE EPING_REPOR
TING)
0x00 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAV EPLUS_NODE)

0x0C06
(ICON_TY PE_SPECIFIC_SENSOR_ NOTIFI CATION_A CCESS_CONTROL)
0x0C06
(ICON_TY PE_SPECIFIC_SENSOR_ NOTIFI CATION_A CCESS_CONTROL)
Association Command Class
Motion Sensor supports 2 association groups and max 5 nodes for each group.
Association Group Info Command Class
Association Group Info
Association Group Command List
COMMAND_CLASS_NOTIFICATION(0x71)
NOTIFICATION_REPORT(0x05)
COMMAND_CLASS_BATTERY(0x80)
COMMAND_CLASS_DEVICE_RESET_LOCALLY(0x5A)
DEVICE_RESET_LOCALLY_NOTIFICATION(0x01)
COMMAND_CLASS_SENSOR_MULTILEVEL(0x31)
SENSOR_MULTILEVEL_REPORT(0x05)
COMMAND_CLASS_BASIC(0x20)
(0x03) TAMPERING_COVERING_REMOVED
(0x08) MOTION_DETECTION_UNKNOWN_LOCATION
(0x0A) REPLACE_BATTERY_SOON
(0x0B) REPLACE_BATTERY_NOW

10
Wake Up Interval Capabilities Report CC
WAKEUP_PAR_DEFAULT_SLEEP_TIME
WAKEUP_PAR_MAX_SLEEP_TIME
WAKEUP_PAR_MIN_SLEEP_TIME
Manufacturer Specific Report
Configuration Set Command Class
Command Format
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Configuration Value 1(MSB)
Configuration Value n(LSB)
Parameter Number Definitions (8 bit)
Low battery power level of alarm threshold values: the
value range are 0~50 for percentage, the battery low
power level can setting 0%~50%.

Setup the PIR detects functionality.
0 = Disable the PIR
1 = Enable the PIR
Setup the wait time of PIR for clear the motion.
Valid values: 0x05~0x3BC4
When the Motion Sensor is triggered, if this parameter is
0x01 then it will send Basic set command to group 1.
0 = Don't send.
1 = Send.
PIR triggers the correspondence between the value of the
Basic set and the PIR state.
-If this value is 0x00 :
PIR triggers send the basic set with 0xFF, PIR alarm
release send the basic set with 0x00.
-If this value is 0x01 :
PIR triggers send the basic set with 0x00, PIR alarm
release send the basic set with 0xFF.
Only support 0x00 and 0x01 values as valid value.
7. Attention
1. If need to clean the sensor, please use a soft cloth with a little alcohol to wipe it after you cut off the
power.
2. This product is just for indoor use.
3. Replace the battery timely on low battery warning to ensure the detector works properly. Please remove
the battery and safe keeping, if you don’t use this product for a long time.
4. This device can be mounted on the wall only, it cannot be installed on the ceiling.
5. The reference range template of PIR detection is tested at the indoor temperature (the range is 20℃~
25℃),the target of the test is 77kg±10kg weight and 1.71m±0.3m height, the target of the test across
movement speed is 4m/s±0.15m/s.
6. In order to prevent the PIR sensor’s abnormal fault, please don’t mounting and operating sensor in the
bellow conditions,
Firstly, product mounting should prevent installed in the air flow environment such as in front of the
door, window, heater, air conditioner and so on.
Secondly, the PIR detection area should not be shielded by other screen.
Thirdly, if the operating temperature range is out of the defined range of product specification may result
in some product faults, which is not in the technique commitment of manufacturer.
Fourthly, this product has mot pet immunity function, so when some animals go through in front of the
product may trigger PIR function reported.

12
FCC Statement
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Note: The grantee is not responsible for any changes or modifications not expressly approved by
the party responsible for compliance. Such modifications could void the user’s authority to operate
the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occ ur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help
RF Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance of 20 cm
between the radiator and your body.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUCTIONS