LED Roadway Lighting Installation Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
!
TOOLLESS
ACCESS
WARNING – RISK OF SHOCK – DISCONNECT POWER BEFORE SERVICING
IMPORTANT: READ CAREFULLY BEFORE INSTALLING LUMINAIRE.
GENERAL: Upon receipt of luminaire thoroughly inspect for any damage.
SAFETY: OPENING THE COVER FOR INSTALLING, SERVICING, OR CLEANING SHOULD BE PERFORMED BY A QUALIFIED SERVICE PERSON. This luminaire
must be wired in accordance with the National Electrical Code, National Electrical Safety Code and applicable local codes and ordinances. Proper
grounding is required to ensure personal safety. Overload circuit protection is recommended. Min 75°C supply conductors. ATTENTION: See the electrical specications on the product label.
1
If mounting on a pole arm greater than
1.66” (42 mm) outside diameter (O.D.), re-
6
✓
X
ORIENTATION: For optimum light distribution, install luminaire parallel to the road.
move inner circle of barrier shield.
2
Open the door by releasing the quick access
latch. Care should be taken to exert force
only in the direction of the arrow, as rotational force can cause inadvertent latch dis-
7
Once luminaire is set to desired tilt and orientation, tighten all pole clamp bolts to 16
ft-lb (21.7 N m).
location. Note: Door will now swing freely.
3
Loosen pole clamps in two places with
9/16” (14 mm) hex head. Clamp should be
loosened suciently to allow insertion of
pole as needed.
8
Route AC mains cable through strain relief.
Attach AC wires to terminal block; L1: Line
(Hot) lead; N/L2: Neutral lead or Second
Line lead; Ground/Protective Earth :
4
Slide luminaire onto pole, ensuring pole
barrier shield is not displaced.
Ground/Protective Earth lead. Maximum
screw driver blade size is 7/32” (5.5mm),
straight-shaft blade-tip. Recommended
torque on terminal screws is 16 in-lb (1.8
Nm). It is essential that proper polar-
ity is observed or the luminaire may be
damaged. Secure leads with tie wrap to
5
Check the level of the pole arm. Select step
for desired tilt (-5°, -2.5°, 0°, +2.5°, +5°),
40 lb (178 N). A minimum 9 mm outside
diameter entry cable is recommended.
then tighten bolts until clamps are snug
against pole.
-5° -2.5° 0° +2.5° +5°
Customer Service Centre
(Hours: 8:00 AM – 4:30 PM, AST)
T: +1.855.667.1228 (Canada & USA)
F: +1.902.667.1233 (Worldwide)
Close door; ensure latch is fully engaged.
Apply force only as shown by arrow.
10
TO UPGRADE COMPONENTS PLEASE REFER TO THE APPROPRIATE STEPS BELOW:
Install photocontrol or shorting plug, if
applicable. To maintain luminaire certi-
cation, these items must contain electrical
certication appropriate for the installation
region (e.g. UL/CSA-listed in North America,
CE in Europe).
A
WARNING – RISK OF SHOCK – DISCONNECT
POWER BEFORE SERVICING. Open the door
by releasing the quick access latch. Note:
Door will swing freely.
TO REPLACE THE LED LIGHT ENGINE
B
Note plug orientation and then unplug.
Turn the LED light engine latch to release
the engine. Remove the existing light engine and insert the new engine, ensuring
one end is fully inserted under the retention bar. Ensure the new engine mounts
ush against the luminaire. Turn the latch
to secure the engine in place. Attach cable
connector to new LED engine.
TO REPLACE THE POWER SUPPLY
C
Unplug the cable connector and push the
clip to release the power supply. Insert
the new power supply and ensure the clip
secures it in place. Attach the cable connector.
TO REPLACE THE SURGE MODULE (IF APPLICABLE)
To disconnect surge module, utilize tool-
D
less cable connectors only. Do not adjust
load-side of terminal block. Remove
surge module from retention features
by twisting cable-clips. Open lever on
splicing connector to each of the three
electrical leads (L1, N/L2, G/PE) to disconnect surge protection module. Connect new surge protection module using
the same connectors. ENSURE PROPER
POLARITY IS MAINTAINED. Secure replacement surge module by twisting cable-clips onto new surge module wiring.
E
Close door; ensure latch is fully
engaged. Apply force only as shown
by arrow.
Ingress Protection: The NXTTM Series luminaire is designed to be protected from the eects of the outside environment. The power supply and optics compart-
ment is designed to be impervious to dust and powerful water spray, and carries an IP66 protection rating. The primary service compartment for installation of the
mounting pole and electrical connections carries an IP23 protection rating. For higher IP rating, please consult factory.
MODEL LEDSWEIGHTLENGTHWIDTHHEIGHTEPA RATING
NXT-C
NXT-S
NXT-M
Max. Ambient Temperature (Ta): NXT-C (+50ºC) NXT-S (+50ºC) NXT-M (+40ºC)
Mounting Height: Up to 65.6 ft (20 m)
Nominal Pole Arm: 1.66” (42 mm) to 2.375” (60 mm) O.D.
12 LEDs
12, 24, & 36 LEDs
48, 60, & 72 LEDs
< 12 lbs (5.4 kg)
Customer Service Centre
(Hours: 8:00 AM – 4:30 PM, AST)
18 lbs (8.2 kg)
26 lbs (11.8 kg)
18.3” (465 mm)
23.2” (589 mm)
29.5” (750 mm)
Torque Setting for Mounting Bolts: 16 ft-lb (21.7 N m)
Recommended Force to Secure Strain Relief: 40 lb (178 N)
Acceptable Supply Wire Sizes: #14 AWG (2.5 mm2) up to #6 AWG (13.3 mm2)
T: +1.855.667.1228 (Canada & USA)
F: +1.902.667.1233 (Worldwide)
IMPORTANT: LIRE ATTENTIVEMENT AVANT D’INSTALLER LE LUMINAIRE.
AVIS: À la réception du luminaire, inspectez-le soigneusement pour déceler tout endommagement
SÉCURITÉ: L’OUVERTURE DU COUVERCLE POUR L’INSTALLATION, LA MAINTENANCE OU LE NETTOYAGE DEVRAIT ÊTRE EFFECTUÉ PAR UNE PERSONNE
QUALIFIÉE. Ce luminaire devrait être câblé en conformité avec le National Electrical Code, le National Electrical Safety Code ainsi que tout autre code
de conformité local. Une mise à la terre appropriée est requise pour assurer la sécurité. Un circuit de protection de surcharge est recommandé. Conducteurs d’alimentation Min 75°C. ATTENTION: Consulter les spécication électriques sur l’étiquette du produit.
1
Si le montage est sur un fût à potence
supérieur à 1.66” (42 mm) de diamètre
6
✓
X
extérieur, retirer le disque intérieur de
barrière de protection.
2
Ouvrir la portière en relâchant le loquet à
accès rapide. Il faut veiller d’exercer une
force seulement dans la direction de la
7
èche, étant donné que la force de rotation peut provoquer la dislocation de ver-
ORIENTATION: Pour une distribution
d’éclairage optimale, installer le luminaire
parallèle à la route.
Lorsque le luminaire est installé avec
l’inclinaison et l’orientation désirés, serrer
tous les écrous des pinces de xation à
21.7 N (16 ft-lb).
rouillage involontaire. Note: La portière
sera désormais libre de tout mouvement.
3
Desserrer les pinces de xation à deux endroits avec les têtes hexagonales de 9/16”
(14 mm). Les pinces de xation devraient
être susamment desserrées pour assurer
l’insertion du fût tel que désiré.
8
Acheminer les câble AC dans le dispositif
de décharge de traction; Fixer les câbles
AC au bloc terminal; L1: Ligne de plomb
(Chaud); N/L2: Fil neutre ou seconde ligne
4
Insérer le luminaire sur le fût, en vous assurant que la barrière du fût n’est pas déplacée.
de plomb; Protection de mise à terre :
Fil de masse. Taille maximale de lame du
tournevis à 5.5mm (7/32’’), extrémité de la
lame arbre droit. Couple recommandé sur
les vis des bornes est de 1,8 Nm (16 in-lb).
Il est essentiel que la polarité appropriée soit observée sinon le luminaire
5
Vérier le niveau du bras. Choisir l’échelon
pour l’inclinaison désirée (-5°, -2.5°, 0°,
+2.5°, +5°), et serrer les écrous jusqu’à
ce que les pinces de xation soient bien
ajustées au fût.
risque de s’endommager. Sécurisez les
lignes en les xant à 40 lb (178 N) à
l’aide d’attaches autobloquantes. Un
câble de diamètre extérieur minimum de
9mm est recommandé.
-5° -2.5° 0° +2.5° +5°
Centre de Service à la Clientèle
(Heures d’ouverture: 08h00 – 16h30, AST)
T: +1.855.667.1228 (Canada et États-Unis)
F: +1.902.667.1233 (Mondial)