LEDone Distribution Inc L401, L402, L403, L404 Installation Instructions Manual

Installation Instructions
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. To reduce the risk of electrical shock, turn off power supply before installation or servicing.
2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician.
3. If NEMA photo control is installed refer to NEMA Receptacle section for instructions.
4. Verify the availability of necessary tools and incidental material.
TO INSTALL:
260
102
458
L401/L402
330
Latc he s
Moun ti ng Bracje t Bolt s
Powe r Do or
2
3
1
134
527
L403/L404
LUMINAIRE INSTALLATION
STEP 1:
Unfasten the stainless steel latches. See Figure 1.
STEP 2:
Open the power door. Power door will securely hang. See Figure 2.
STEP 3:
Slide fixture on to pole through opening on the rear of housing and through splashguard. See Figure 3.
STEP 4:
To level fixture, use bubble level located inside housing. Adjust leveling of fixture from side to side. To level from front to back, slide pole to different step in upper housing. Each step changes the angle in 2.5° degree increments. See Figure 3.
Spla sh guard
Moun ti ng Brac ke t
Tilt: Stopping at the step marked “0”
provides no tilt. Stopping at the step marked ”+5" provides maximum tilt.
Adju st ment Step s
Pipe
Pipe Size
1-3/4 IN O.D. (44.45mm)
2-3/4 IN O.D. (60.3mm)
TORQUE VALUES
Pipe Position
+5.0 degrees tilt 200 22
+2.5 degrees tilt 200 22
0 degrees (no tilt) 200 22
-2.5 degrees tilt 200 22
-5.0 degrees tilt 200 22
+5.0 degrees tilt 200 22
+2.5 degrees tilt 200 22
0 degrees (no tilt) 200 22
-2.5 degrees tilt 200 22
-5.0 degrees tilt 200 22
Bolt Torque
Required (in-lbs)
Bolt Torque
Required (N-m)
STEP 5:
Once desired position is achieved, tighten mountingboltstotheappropriate torquevaluesspecifiedinTORQUE VALUEStabletotheleft. IMPORTANT :DO NOT exceed these torque levels on the mount bolts. Exceeding recommended torque value resulting in excessive deformation of mounting bracket will causes tripping of mount hardware which could lead to an unsafe mounting condition.
STEP 6:
Reference Electrical Connections section for completing electrical connections. See
Figure 4.
4
Step 7:
Close the housing cover and fasten the two stainless steel latches. See Figure 5.
L N G
Make the fo llowing Elect rical Conn ections to the te rminal blo ck:
1. For 120/ 277V/347/48 0 connect th e black fixtu re le ad to the voltage s upply positio n of the termi nal block .
2. For 120/ 277V/347/48 0 connect th e white fixtu re le ad to the neutral s upply positio n of the termi nal block .
3. Connec t the green or gree n/yellow g round lead to the green wir e position of the t erminal bl ock.
4. If Dimmi ng is an optio n; co nnect the vi olet dimmi ng positiv e lead to the suppl y dimming po sitive lead.
5. If Dimmi ng is an optio n; co nnect the gr ey dimming negativ e lead to the suppl y dimming ne gative lead
Latc he s
Step 8:
If luminaire is furnished with photocontrol receptacle, install the photocontrol or shorting.See Figure 6.
Phot oc ontrol
6
5