Ledj Stage Par CZ 120 RGBA User Manual

Order codes:
LEDJ192 - Black Housing
LEDJ192P - Polished Housing
Stage Par CZ 120 RGBA
User Manual
2
Safety advice
WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Before your initial start-up, please make sure that there is no damage caused during transportation.
• Should there be any damage, consult your dealer and do not use the equipment.
• To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
• Please note that damages caused by user modications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
CAUTION!
KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING THIS EQUIPMENT!
HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
• Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
• Never remove warning or informative labels from the unit.
• Do not open the equipment and do not modify the unit.
• Do not connect this equipment to a dimmer pack.
• Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.
• Only use the equipment indoors.
• Do not expose to ammable sources, liquids or gases.
• Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
• Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.
• Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.
• If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualied engineer inspect the equipment before operating again.
• If the equipment has been exposed to drastic temperature uctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature.
• If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service.
• Only use fuses of same type and rating.
• Repairs, servicing and power connection must only be carried out by a qualied technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
• This lighting xture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualied technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The xture presents risks of severe injury or death due to re hazards, electric shock and falls.
• Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
• WARRANTY: One year from date of purchase.
3
Stage Par CZ 120 RGBA
FUSE:
T2A 250V
100-240V~50/60Hz
POWER CONSUMPTION: 150W
POWER INPUT POWER OUTPUT
SAFETY
EYE
DMX OUTPUTDMX INPUT
MENU ENTERDOWNUP
www.prolight.co.uk
01
02
07
03
04
0605 08 09
Product overview & technical specications
The CZ 120 RGBA Stage Par is powered by a high output 120W quad-colour COB (chip-on-board) RGBA LED, ideal for stage productions, concerts or theatre applications. The beam angle can be manually adjusted between 15° and 35° and on-board controls offer 4 different dimmer curve options, whilst the 5-pin DMX and powerCON input/ output allow for easy connections, adding to the host of professional features on these xtures. The traditional par can style housing is available in black or polished aluminium and a gel frame holder is supplied enabling diffusion lters to be tted.
• 1 x 120W quad-colour LED (RGBA)
• Manually adjustable beam angle: 15° - 35°
• 13,800 Lux @ 2m (full on)
• 3kHz refresh rate
• DMX channels: 4/7 or 11 selectable
• Manual and master/slave modes plus built-in programs
• 0-100% dimming and variable strobe
• Supplied with hanging bracket
• 4 push button menu with LED display
• PowerCON input/output
• 5-Pin XLR input/output
• Fan cooled
• Filter frame included
Stage Par CZ 120 RGBA
Specications Stage Par CZ 120
Power consumption 150W
Power supply 100~240V, 50/60Hz
Fuse T2A 250V
Dimensions 405 x 302 x 444mm
Weight 3.9kg
Order codes LEDJ192 - Black Housing
LEDJ192P - Polished Housing
01 - LED display
02 - Function buttons
03 - 5-Pin XLR input
04 - 5-Pin XLR output
05 - PowerCON input
06 - PowerCON output
07 - Fuse T2A 250V
08 - Earth point
09 - Safety eye
In the box: 1 x xture,
1 x lter frame, 1 x power cable & 1 x user manual
4
Beam angle (lens) adjustment:
To adjust the beam angle squeeze the spring loaded latch inside the front nose of the par can.
The latch can then be moved forwards or backwards smoothly, allowing the operator to select
the beam angle required between 15° and 35° using the markers provided as a guide.
Release the spring loaded latch once the beam angle has been selected to prevent any
further movement.
405mm
302mm
237mm
444mm
419mm
Product overview & technical specications
5
Operating instructionsOperating instructionsOperating instructions
MENU
0 0 1
5 1 2
A d d r
DMX address setting
O N
O F F
N A S t
Master setting
S L 1
S L 2
S L N d
Slave setting
b L N d
L A S t
d N S t
No DMX signal
S N O O
F A S t
S P d
Dimmer speed setting
C U r V
Dimming curves
L I N
S q U
I S q U
S C U r
4 C H
7 C H
1 1 C H
C H N d
Channel modes
S H N d
Show modes
Colour macros
C o 0 1
C o 6 4
S H 0
S H 1
S H 9
S P 0 0
S P 9 9
Loading...