Lectrotab OVAL, SETR-61, SETR-60 User Manual

Page 1
• Microprocessor based trim tab control with LED tab position indicators
• Completely sealed, completely waterproof and will not deteriorate in sunlight
• Tabs automatically retract and calibrate on key switch on or off
• Easy upgrade from rocker switch style control with BP-10 mounting plate
• No external power module required
• Automatically dims LED tab position indicators in darkness and brightens in sunlight
• Adjustable programming features located on back of specification sheet
• Operates up to 2 actuators per tab on 12vdc and 4 actuators per tab on 24vdc systems
• Black or Gray color display available
FEATURES
Linear Devices Corporation 8790 Park Central Drive, Richmond, VA 23772 www.lectrotab.com, Ph 804-261-3888, Fax 804-264-3070 January 2011
The Oval control combines a microprocessor based trim tab control with an LED tab position indicator. This control incorporates automatic tab retraction and calibration whenever the control power is switched on or off. This unique design requires no feedback sensor for tab position. LED indicators automatically dim at night and brighten in sunlight. The Oval is completely sealed and waterproof. Its rubberized cover is UV protected and will not deteriorate in sunlight. The control switch is self­contained and does not require an additional control box.
Lectrotab’s Oval control can be used as a single station or
can handle up to 6 stations in constant communication with each other.
Oval LED Control
SPECIFICATIONS
Model
Number
Display
Color
Number of
Stations
Overall
Width
Overall
Height
Mounting
Hole Cutout
(Diameter)
DC
Voltage
Fuse Size
Power Input
(1 Actuators per Tab)
Fuse Size
Power Input
(2 Actuators per Tab)
Fuse Size
AUX Terminal
(MUST CONNECT)
SETR-61
Black
Up to 6
(Use 1 SR
Cable per SETR for
2 or more stations)
3.94"/
100mm
3.38"/
86mm
2"/51mm -
2.5"/63.5mm 12/24
12vdc = 20 amp 24vdc = 10 amp
12vdc = 30 amp 24vdc = 20 amp
.1 amp
SETR-60
Gray
Up to 6
(Use 1 SR
Cable per SETR for
2 or more stations)
3.94"/
100mm
3.38"/
86mm
2"/51mm -
2.5"/63.5mm 12/24
12vdc = 20 amp 24vdc = 10 amp
12vdc = 30 amp 24vdc = 20 amp
.1 amp
SETR-61 Oval Control
Page 2
Linear Devices Corporation 8790 Park Central Drive, Richmond, VA 23772 www.lectrotab.com, Ph 804-261-3888, Fax 804-264-3070 January 2011
OVAL (SETR) PROGRAMMING
Enter, Adjust and Exit Program Mode:
• Before entering program mode, 12vdc or 24vdc must be applied to Oval main power
• Power to AUX terminal must be OFF (Aux is typically connected to ignition key switch or aux switch)
• Press and hold button noted in Oval Programming chart under column “Enter” for more than 2 seconds
while switching the Aux terminal switch to ON at the same time
• Release the “Enter” button and press “STBD BOW UP or DOWN” button to change the value
• Press and hold “PORT BOW UP” for more than 2 seconds to exit program mode
Program Mode Sequence
Function
Enter
Adjust
Exit
Range
Default
Program Details
Timing
PORT BOW DOWN
STBD BOW
DOWN/UP
PORT BOW UP
4 - 12sec
8sec
8 LED's = 8 second actuator 4 LED's = 4 second actuator
LED's On/Off
PORT BOW UP
STBD BOW
DOWN/UP
PORT BOW UP
On/Off
On
8 LED's = LED ON
1 LED = LED's OFF
Swap LED's
STBD BOW DOWN
STBD BOW
DOWN/UP
PORT BOW UP
LED's
Opposite of
button/same
side button
LED's
Opposite of
button press
1 LED on right and left = LED
lights opposite of button press
8 LED's on right and left = LED
lights same side as button press
OVAL (SETR) WIRING/INSTALLATION DIAGRAM
(-)
DC ground Use 14ga. wire
Communications Port for second station. See Installation Manual for details.
"OVAL " (SETR) Control Installation/Wiring Diagram
(+)12 or 24 VDC input power. Use 14ga. wire. 12vdc = 15 or 20 amp fuse 24vdc = 10 amp fuse This input voltage must match the voltage rating on the actuators being used.
Note (for S1): "Oval" AUX terminal function:
1) Switch (S1) opens 12vdc power to initiate a 10 second tab retract and Oval control will shut down.
2) Switch (S1) closes 12vdc power to initiate a 10 second tab retract and Oval control will continue functioning.
3) The Aux terminal is typically connected to a
+12vdc source that is shut down after docking to allow tabs to retract, recalibrate and prevent
damage.
(+)
(-)
AUX
BK RD GN
WH
GREEN
WHITE
BLACK
RED
BLACK
WHITE BLACK
WHITE
Stbd Actuator
W4-** Interconnect Cable
Port Actuator
BK
RD
GN WH
W4-** (**=length) 4 conductor, 14 AWG interconnect cable may be used or actuator may be ordered with extended cable i.e. A-BK-13 = 23 ft. (7m), A-BK-24 = 28 ft. (8.5m) connecting to SETR.
Oval (SETR) Control
MUST CONNECT
(+)12 or 24 VDC input power. Use 16ga. wire min.
.1 amp Fuse
See Note S1
OR Use A-BK-13 or A-BK-24 extended cable from actuator connecting directly to SETR.
Port Actuator
Stbd Actuator
(+)
(-)
AUX
BK
RD
GN WH
Oval (SETR) Control Dimensions
Port Actuator
Stbd Actuator
3.38
86mm
1.48
37.6mm
3.94
100mm
1.69
42.9mm
MUST CONNECT
Loading...