LeCroy WS-DCADAP User Manual

Accessory
WS-DCADAP
User's Manual
WaveSurfer is a trademark of LeCroy Corporation.
f Microsoft Windows is a registered trademark or a trademark o
Corporation in the United States and other countries.
EXTERNAL DC ADAPTER User’s Manual
Foreword
Thank you for purchasing LeCroy's EXTERNAL DC ADAPTER. Before using this instrument, please read this manual thoroughly to
gain a good understanding of it. After reading, please keep the manual in a safe place.
This manual describes notes on use and basic usage of the
EXTERNAL DC ADAPTER.
Notes
Parts of the contents of this manual may be modified without prior
notice for improvements in performance and functions.
Reproduction or reprinting of the contents of this manual without
prior permission from LeCroy is prohibited.
If you have questions about this instrument, please contact LeCroy
Corporation. (Refer to the contact address given at the end of this manual.)
Revision History
June 2005: 1st edition
i
Checking the Packing Content
On delivery of the instrument, check each item. If any of the items are missing or there is any damage, immediately contact L eCroy or the sales office in charge.
[Items to be present]
DC Adapter (EXTERNAL DC ADAPTER)................................1
Accessories
WS-DCADAP cable.....................................................................1
Safety Ground cable ……………………………………………..1
User's manual ...............................................................................1
Sending Back for Repairs
If the instrument is inoperable, send it back to LeCroy Corporation. (Refer to the contact address given at the end of this manual.) We will repair it without charge as long as it is under warranty.
When sending back the instrument, explicitly describe the following: product name, serial number, description of the trouble, name/post/phone number of the contact person.
ii
Table of Contents
Safety Requirements....................................................................... 2
Safety Symbols & Terms................................................................. 2
Operating Conditions ...................................................................... 2
Product Disposal and Recycling...................................................... 5
Overview ......................................................................................... 6
Configuration................................................................................... 6
Units and Devices............................................................................ 7
(a) DC Adapter ................................................................................ 7
(b) WS-DCADAP Cable................................................................... 8
Operating Procedures ..................................................................... 9
(a) Mounting the DC Adapter on the Oscilloscope .......................... 9
(b) Connecting the DC Power Cord to the Oscilloscope ............... 10
(c) Connecting the WS-DCADAP Cable.........................................11
(d) Connecting the WS-DCADAP Cable to the Battery ................. 13
(e) Starting Up the Oscilloscope.................................................... 14
(f) Turning Off the Oscilloscope.................................................... 16
(g) Turning Off the DC Adapter and the Battery ............................ 16
Indicators....................................................................................... 17
Protective Functions...................................................................... 18
Specifications ................................................................................ 20
(a) Product Specifications - Electrical............................................. 20
(b) Product Specifications - Mechanical......................................... 21
(c) Certifications............................................................................. 21
Safety Requirements
This section contains information and warnings that must be observed to keep the DC Adapter operating in a correct and safe condition. You are required to follow generally accepted safety procedures in addition to the safety precautions specified in this section.
Safety Symbols & Terms
The following safety symbols & terms may appear on the product and they alert you to important safety considerations.
This symbol is used where caution is required. Refer to the accompanying information or documents in order to protect against personal injury or damage to the instrument.
This symbol warns of a potential risk of shock hazard.
The CAUTION sign indicates a potential hazard. It calls attention to a procedure, practice or condition which, if not followed, could possibly cause damage to equipment. If a CAUTION is indicated, do not proceed until its conditions are fully understood and met.
The WARNING sign indicates a potential hazard. It calls
attention to a procedure, practice or condition which, if not followed, could possibly cause bodily injury or death. If a WARNING is indicated, do not proceed until its conditions are fully understood and met.
CAUTION
WARNING
Operating Conditions
Before using this product, ensure that its operating environment will be maintained within these parameters:
Temperature : 5 to 40
o
C
Humidity : Maximum relative humidity 80 % for temperatures up to 31
o
C decreasing linearly to 50 % relative
humidity at 40
o
C.
Altitude: Up to 2,000 m
2
EXTERNAL DC ADAPTER User’s Manual
The design of the DC Adapter has been verified to conform to the applicable safety standards (EN 61010-1:2001, UL 61010-1 2
nd
Edition and CAN/CSA C22.2 No.61010-1-04) per the following limits:
Installation (Overvoltage) Category I (All mains isolated terminals)
Pollution Degree 2 Protection Class I
CAUTION
To avoid personal injury or damage to the WS-DCADAP or the WaveSurfer oscilloscope connected to it, review and comply with the following safety precautions.
Use only as intended.
The WS-DCADAP is intended to be used only with the LeCroy Wa veSurfer series oscilloscopes to supply the DC drive power to the scope. Use of the WS-DCADAP and/or the scope it is connected to in a manner other than specified may impair the protection mechanisms.
Connect and disconnect properly.
Avoid damage to cables thru excessive bending.
Do not use in wet/damp or explosive atmospheres.
For indoor use only.
The WS-DCADAP is intended for indoor use and should be operated in a clean, dry, environment.
Do not operate with suspected failures.
Do not use WS-DCADAP if any part is damaged. All maintenance should be referred to qualified service personnel.
Keep product surfaces clean and dry.
3
Do not float the WaveSufer oscilloscope when it is powered by
DC Adapter. Use the safety ground cable to connect oscilloscope to earth ground.
When operating the WaveSurfer oscilloscope from AC line power with the standard power cord the oscilloscope is connected to earth ground via the third-wire in the AC power cord. When operating the WaveSufer oscilloscope with the WS-DCADAP, there is no connection to earth ground and the oscilloscope is floating.
Operating the oscilloscope in this manner causes accessible metal parts to be at the same potential of the probe ground leads. This results in a dangerous condition with the potential of elevated voltages present on the oscilloscope causing a shock hazard to the operator and also places stress on the power transformer insulation. Over time this stress may result in dangerous failures which create a shock and fire hazard even during properly grounded operation.
Without AC power and the standard AC power cord the WaveSurfer oscilloscope is not grounded and will be floating unless the included grounding cable is connected between the oscilloscope and earth ground. If the oscilloscope probes or channels are connected to circuits or devices that have voltages less than 30Vrms or 42Vpk from earth ground the ground cable is not required. For any circuits where voltages greater than 30Vrms or 42Vpk may be present the ground cable must be connected. If the operator is unsure if a higher voltage is present the ground cable should be used. Operating the oscilloscope in the presence of these voltages without properly grounding the instrument may result in electrical shock which can result in serious personal injury or loss of life.
It is also important to remember not to connect a grounded device such as a computer or printer to the oscilloscope while it is floating. To connect a grounded device to the WaveSurfer oscilloscope while using the WS-DCADAP the ground cable must be connected between the oscilloscope and earth ground.
4
EXTERNAL DC ADAPTER User’s Manual
WARNING
To avoid electric shock, always connect scope ground terminal to earth ground when WaveSurfer oscilloscope is powered by DC Adapter.
CLEANING
The outside of the WS-DCADAP hardware should be cleaned with a soft cloth dampened with either deionized / distilled water or isopropyl alcohol. Allow the surface to dry completely before returning the instrument to service.
USE AND MAINTENANCE
The WS-DCADAP is a high quality, precision instrument. To maintain accuracy, mechanical shock should be avoided, as well as damage to the cables through excessive bending. All maintenance and component replacement should be referred to qualified personnel.
Product Disposal and Recycling
This electronic product is subject to disposal and recycling regulations that vary by country and region. Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles.
For more information about proper disposal and recycling of your LeCroy product, please visit www.lecroy.com/recycle.
5
Loading...
+ 18 hidden pages