LeCroy 9354C Data Sheet

9350C 9354C
9370C 9374C 9384C
Datasheet
LEADING SPECIFICATIONS
LeCroy Digital Oscilloscopes
Get the Complete Picture
500 MHz and
1 GHz Bandwidth
2 GS/s and
Two and Four
Channels
•Memory lengths to 8M points
8-bit vertical
resolution, 11 with ERES option
Floppy Disk
and Centronics Port standard
Internal Printer
option
Histogram and
FFT Signal Processing options
Innovative Peak
Detect
Glitch, Pattern,
Qualified, Interval, Dropout, TV, and Exclusion Triggers
Digital oscilloscopes from LeCroy are designed to save engineers valuable time in troubleshooting and problem­solving.
Each oscilloscope is an integrated and powerful system providing the capability to:
Capture fast signals with high
resolution for longer time intervals
View data like never before, giving
you more information more quickly, with a large CRT and advanced zooming techniques
Analyze your signal to get answers
quickly and more accurately with a powerful processing system and math packages
BANDWIDTH
ADVANCED PEAK DETECT
AP015 Current Probe, 50 MHz bandwidth
The LeCroy DSOs open up new horizons for engineers and scientists at the leading edge of technological developments. With 500 MHz (935xC) and 1 GHz (937xC, 9384C) bandwidth, long acquisition memories and a powerful trigger system, it is now possible to reveal previously hidden waveform details. Narrow glitches are more accurately defined; risetime measurements below 1 ns are more precise; and high frequency content, filtered out in lower bandwidth systems, is retained, thereby preserving signal amplitudes and overall signal integrity.
SAMPLE RATE
These LeCroy DSO’s sample simulta­neously on all channels at 500 MS/s (935xC, 937xC) and 1 GS/s (9384C). Thus, they are ideal for demanding high-speed applications. In addition, two channels can be combined to provide a sample rate of 1 GS/s (935xC, 937xC) and 2 GS/s (9384C), or 2GS/s (9354C, 9374C) and 4 GS/s (9384C) in single channel mode. Finer horizontal resolution and accuracy are assured by higher sample rates. This is especially critical in digital design where unpredictable circuit behavior needs to be identified and analyzed in detail to be fully understood. Together with this excellent single-shot performance the LeCroy oscilloscopes also provide a sample rate equivalent to 10 GS/s for repetitive signals. The innovative peak­detect mode enables glitch capture even at the slowest time settings without loss of precision.
ACQUISITION MEMORY
Channel record lengths of 50k, 100k, 500k, 1M and 2M are available on the LeCroy oscilloscopes. The memory power is revealed when the user seeks to sample at the highest speed over many timebase settings. DSOs with less memory may boast a high sample rate for short waveforms, but only LeCroy’s long memory oscilloscopes deliver high sample rates for long waveforms. To exploit this capability to its fullest, the long memory version combines its channel acquisition memories to give the user up to 8 million sample points, thereby providing the waveform detail required on long and complex signals.
SYSTEM
The 93xxC series offers an innovative peak detect capture mode. This captures fast glitches by running the ADCs at a high sampling rate even at slow time base settings thereby capturing signal details that might have been missed due to under-sampling.
SMART TRIGGERTMSYSTEM
SMART Trigger functions including Glitch, Pattern, Interval, Exclusion, TV, Dropout, and State-or-Edge Qualified triggers are available. Pre- and Post­trigger delay are fully variable, Time and Events Holdoff are also included.
ACQUISITION SYSTEM
Bandwidth (-3 dB):
935XC:
@50 : DC to 500 MHz 100 mV/div: 400 MHz 50 mV/div and above: 350 MHz
937xC/938xC:
@ 50 : DC to 1 GHz 10 mV/div and above.
Bandwidth (-3 dB):
@ 1 M: DC to 500 MHz typ. at probe tip with optional 1 GHz FET probe for 935xC and with PP005 supplied as standard for 937xC and 9384C.
No. of Channels:
4 (9354C/9374C/9384C) and 2 (9350C/9370C)
No. of Digitizers:
4 (9354C/9374C/9384C) and 2 (9350C/9370C)
Sensitivity:
935xC:
2 mV/div to 5 V/div, fully variable
937xC/9384C:
2 mV/div to 1 V/div, 50 fully variable. 2 mV/div to 10 V/div, 1 Mfully variable.
Scale Factors: A wide choice of probe attenuation factors are selectable.
Offset Range:
935xC: 2.0 - 9.9 mV/div: ±120 mV
10.0 - 199 mV/div: ±1.2 V
0.2 - 5.0 V/div: ±24 V
937xC/9384C:
2.0 - 4.99 mV/div: ±400 mV
5.00 - 99 mV/div: ±1 V
0.1 - 1.0 V/div: ±10 V
1.0 - 10 V/div: ± 100 V
(1 Monly).
± 20 V across the whole sensitivity range when using the AP020 FET probe.
DC Accuracy: 1% typical.
9354CL/9374CL/9384CL
9350CL/9370CL
9354CTM/9374CTM 9384CM/9384CTM
9354CM/9374CM
9350CM/9370CM
9354C/9374C
9350C/9370C n.a
50 kpoints
100 kpoints
n.a
250 kpoints
500 kpoints
2 Mpoints
9384C
2 Channels
in use
4 Channels
in use
1 Channel
in use
50 kpoints 100 kpoints 250 kpoints
250 kpoints 500 kpoints
1 Mpoints
2 Mpoints 4 Mpoints
100 kpoints 200 kpoints 500 kpoints
500 kpoints
1 Mpoints
2 Mpoints
4 Mpoints 8 Mpoints
Memory per Channel
Models
n.a
Vertical Resolution: 8 bits. Bandwidth Limiter:
935xC: 30 MHz user selectable. 937xC/9384C:
25 MHz or 200 MHz user selectable.
Input Coupling: AC, DC, GND. Input Impedance:
935xC: 10 M// 15 pF typical, system capacitance at probe tip using PP002 probe, or 50± 1% 937xC/9384C: 10 M// 11 pF typical, system capacitance at probe tip using PP005 probe, or 50± 1%
Max Input:
935xC: 1 M: 250 V (DC+peak
AC 10 kHz) 50 : ±5 V DC (500 mW) or 5 V RMS
937xC/9384C:
1 M: 400 V (DC + peak AC 10 kHz) or 5 V RMS 50 : ±5 V DC (500 mW) or 5 V RMS
MAXIMUM SAMPLE RATE
Models 4 Channels
in use
9350C/9370C n.a 500 MS/s 1 GS/s
2 Channels
in use
1 Channel
in use
TRIGGERING SYSTEM
Trigger Modes: Normal, Auto, Single. Trigger Sources: CH1, CH2, CH3, CH4,
External, Line, Slope, Level and Coupling are unique to each source.
Slope: Positive, Negative. Coupling: AC, DC, HF, LFREJ, HFREJ. Pre-trigger recording: 0 to 100% of
full scale (adjustable in 1% increments). Post-trigger: 0 to 10,000 divisions, (adjustable in 0.1 div increments).
Holdoff by Time: 10 ns to 20 s. Holdoff by events: 0 to 99,999,999. Internal Trigger Range: ±5 div. EXT Trigger Max Input:
935xC: 1 M//15 pF using PP002
probe 250 V DC + peak AC < 10 kHz) 50 ± 1 %: ± 5 V DC (500 mW) or 5 V RMS.
937xC/9384C:
1 M// 11 pF using PP005 probe 400 V (DC + peak AC < 10 kHz) 50 ± 1%: ± 5 V DC (500 mW) or 5 V RMS.
EXT Trigger Range: ± 0.5 V (±5 V with Ext/10). Trigger Timing: Trigger Date and Time are listed in the Waveform Status Menu.
9354C/9374C
9384C
500 MS/s
1 GS/s
1 GS/s
2 GS/s
2 GS/s
4 GS/s
TIME BASE SYSTEM
Timebases: Main and up to 4 zoom
traces.
Time/Div Range:
1 ns/div to 1,000 s/div
Clock Accuracy: 10 ppm Interpolator Resolution: 10 ps Roll Mode: ranges 500 ms to 1,000 s/div.
For > 50k points: 10 s to 1,000 s/div.
MEMORY PER CHANNEL
SMART TRIGGER TYPES
Model
9350C/9354C/9370C/9374C
Segments
9350CM/9354CM/9370CM/9374CM/9384C 9350CL/9354CL/9370CL/9374CL/9384CL
9354CTM/9374CTM/9384CTM/9384CM
2-200 2-500
2-2,000
Model
9350C/9354C/9370C/9374C
Zoom Factor
9350CM/9354CM/9370CM/9374CM
9350CL/9354CL/9370CL/9374CL/9384CM/9384CTM
2,000x
10,000x 20,000x9354CTM/9374CTM/9384C
9384CL
100,000x 400,000x
Pattern: Trigger on the logic combination of 5 inputs - CH1, CH2, CH3, CH4, and EXT Trigger, (9350C and 9370C: 3 inputs - CH1, CH2, EXT) where each source can be defined as High, Low or Don’t Care. The Trigger can be defined as the beginning or end of the specified pattern. Signal or Pattern Width: Trigger on glitches <2.5 ns (1 ns typical) or on pulse widths between two limits selectable from 2.5 ns to 20s. Exclusion Trigger: Trigger on a signal or period outside two limits selectable from 2.5 ns to 20s. Signal or Pattern Interval: Trigger on an interval between two limits selectable from 10 ns to 20 s. Dropout: Trigger if the input signal drops out for longer than a time-out from 25 ns to 20 s. State/Edge Qualified: Trigger on any source only if a given state (or transition) has occurred on another source. The delay between these events can be defined as a number of events on the trigger channel or as a time interval. TV: Allows selection of both line (up to
1500) and field number (up to 8) for PAL, SECAM, NTSC or non-standard video.
ACQUISITION MODE
Random Interleaved Sampling:
9384C (RIS):
For repetitive signals from 1 ns/div to 2 ms/div.
935xC/937xC (RIS):
For repetitive signals from 1 ns/div to 2 µs/div. (M, L: signals from 1 ns/div to 5 µs/div).
Random Interleaved Sampling Rate:
10 GS/s
Single Shot:
9384C:
For transient and repetitive signals from 2 ns/div (all channels active).
935xC/937xC:
For transient and repetitive signals from 10 ns/div (all channels active).
Peak Detect: Captures and displays <2.5 ns glitches or other high-speed events at 400 MS/s. Data points available at the same time. Sequence: Stores multiple events ­each of them time stamped - in segmented acquisition memories.
NUMBER OF SEGMENTS AVAILABLE
DISPLAY
Waveform Style: Vectors connect the
individual sample points, which are highlighted as dots. Vectors may be switched off.
CRT: 12.5 x 17.5 cm (9” diagonal) raster. Resolution: 810 x 696 points. Modes: Normal, X-Y, Variable or
Infinite Persistence. Real-time Clock: Date, hours, minutes, seconds. Graticules: Internally generated; separate intensity control for grids and waveforms.
Grids: 1, 2 or 4 grids. Formats: YT, XY, and both together. Vertical Zoom: Up to 5x vertical
expansion (25x with averaging, up to 80 µV sensitivity with Advanced Waveform Math option WP01). 9354CL/9374CL: Waveforms can be expanded to give 2-2.5 points/division. Zoom factors up to 400,000x with all channels combined. 9384CL: Waveforms can be expanded to give 0.4-0.5 points/division. Zoom factors up to 2,000,000x with all channels combined.
MAXIMUM HORIZONTAL ZOOM
AUTOMATED PARAMETRIC
PARAMETER ANALYSIS MEASUREMENTS AND STATISTICS
The LeCroy DSOs provide more than 40 parametric measurements and their Average, Highest, Lowest values and Standard Deviation. Pass/Fail testing allows up to 5 parameters to be tested against selectable thresholds. Waveform Limit Testing can also be performed using Masks that may be defined inside the instrument. Any failure will activate preprogrammed actions such as Hardcopy, Save, Stop, Beep, GPIB SRQ, or Pulse Out.
ADVANCED WAVEFORM MATH PACKAGE
The Advanced Waveform Math Package option (WP01) provides Summed and Continuous Averaging, Waveform Math Functions, Extrema and Enhanced Resolution Modes. Functions can be chained together, allowing complex computations. Waveform operations can be performed on live, stored, processed or expanded waveforms. The package is fully programmable over GPIB or RS-232-C. Advanced Math extends the processing capabilities of the oscilloscope and eliminates the need for external computers and controllers for processing.
SPECTRAL ANALYSIS
PACKAGE
The Parameter Analysis option (WP03)
provides extensive analysis capabilities
including trending and histogramming
of key parameters. Detailed characteri-
zation can easily be performed on
difficult-to-measure waveform
phenomena such as amplitude
fluctuation and timing jitter. Live
displays include a line graph
representing the trend of a parameter or
bar chart showing the statistical distri-
bution of selected waveform parameter
measurements. Statistical information
can be extracted directly from the
histograms using automatic statistical
measurements including max, min,
average, median, std. deviation, etc.
CURSOR MEASUREMENTS
Relative Time: Two cursors provide
time measurements with resolution of
±0.05% full-scale for unexpanded
traces; up to 10% of the sampling
interval for expanded traces. The
corresponding frequency value is
displayed.
Relative Voltage: Two horizontal bars
measure voltage differences up to
±0.2% of full-scale in single-grid mode.
Absolute Time: A cross-hair marker
measures time relative to the trigger and
voltage with respect to ground.
Absolute Voltage: A reference bar
measures voltage with respect to
ground.
PACKAGE
The Spectral Analysis Package option (WP02) provides comprehensive frequency analysis capabilities, permitting the system designer to identify characteristics that may not be apparent in the time domain. The Spectral Analysis Package provides a wide selection of windowing functions, as well as averaging in the frequency domain. Spectrum analysis can be performed on repetitive and single events. Users can obtain time and frequency values simultaneously and compare phases of the various frequency components with each other.
WAVEFORM PROCESSING
With the Optional Advanced Waveform
Math Package up to four processing
functions may be performed simulta-
neously. Functions available are: Add,
Subtract, Multiply, Divide, Negate,
Identity, Summation Averaging, and
Sine x/x.
Average: Summed averaging of up to
1,000 waveforms in the basic
instrument. Up to 106averages are
possible with the Advanced Math option.
Extrema : Roof, Floor, or Envelope
values from 1 to 106sweeps with the
Advanced Math option.
ERES: Low-Pass digital filter provides
up to 11 bits vertical resolution.
Sampled data is always available, even
when a trace is turned off (with the
Advanced Math option).
FFT: Spectral Analysis with five windowing functions and FFT averaging with Spectrum analysis option. Histogramming and trending: The Parameter Analysis option permits in­depth diagnostics on waveform parameters.
ADDITIONAL INFORMATION
INTERNAL PRINTER
The LeCroy DSOs offer an optional internal printer that can produce a 126 X 90 mm full resolution screen dump in under 10 seconds at the push of a button. The unique “Strip-Chart” format expands the horizontal axis up to 200 cm per division for viewing fine waveform detail within long memory acquisitions.Most printers and plotters can be driven via GPIB, RS-232-C and standard Centronics interface.
INTERNAL MEMORY
Waveform Memory: Up to four 16-bit
Memories (M1, M2, M3, M4). The length of each memory is equal to the data acquisition memory. Processing Memory: Up to four 16-bit Waveform Processing Memories (A, B, C, D). Setup Memory: Four non-volatile memories. Optional IC Memory Cards, ATA Flash Card, floppy disk or PC Card (PCMCIA) hard drives may also be used for high-capacity waveform and setup storage.
AUTOSETUP
Pressing Autosetup sets timebase, trigger and sensitivity to display a wide range of repetitive signals. (Amplitude 2 mV to 40 V; frequency above 50 Hz; Duty cycle greater than 0.1%). Autosetup Time: Approximately 2 seconds. Vertical Find: Automatically sets sensitivity and offset.
REMOTE INTERFACING
GPIB and RS-232-C interfaces may be used for full remote control of the instrument. All front panel and internal processing functions can be controlled via either interface.
PROBES
935xC: One PP002 (10: 1, 10 M// 15 pF) probe supplied per channel. DC to 250 MHz typical at probe tip. 937xC/9384C: One PP005 (10:1, 10 Ω// 11 pF) probe supplied per channel. DC to 500 MHz typical at probe tip. The 93xxC family is fully compatible with LeCroy’s range of FET Probes, which may be purchased separately. Probe Calibration: Max 1 V into 1 M 500 mV into 50 , frequency and amplitude programmable, pulse or square wave selectable, rise and fall time 1 ns typical. Alternatively the Calibrator output can provide a trigger output or a PASS/FAIL test output.
INTERFACING
Remote Control: Possible by GPIB
and RS-232-C for all front-panel controls, as well as all internal functions. RS-232-C Port: Asynchronous up to
115.2 kb/s for computer/terminal control or printer/ plotter connection. GPIB Port: (IEEE-488.1) Configurable as talker/listener for computer control and fast data transfer. Centronics Port: Standard hardcopy parallel interface. Hardcopy: Screen dumps are activated by a front panel button or via remote control. TIFF and BMP format are available for importing to Desktop Publishing programs. The following printers and plotters can be used to make hardcopies: HP ThinkJet, QuietJet, LaserJet, PaintJet, and EPSON printers, HP7400 and 7500 series, or HPGL compatible plotters. An optional internal high-resolution graphics printer is also available.
GENERAL
Auto-calibration ensures specified DC and timing accuracy. Temperature: 5°C to 40°C (41°F to 104°F) rated. 0°C to 50°C (32°F to 122° F) operating.
Humidity: <80% Shock & Vibration: Conforms to
selected sections of MIL-PRF-28800F, Class 3. Power: 90-250 VAC, 45-66 Hz, 350 W (9384C), 230 W (935xC/937xC). Battery Backup: Front panel settings maintained for two years. Dimensions: (HWD)
8.5” x 14.5” x 16.25”, (210mm x 370mm x 410mm). Weight: 13 kg (28.6 lbs) net, 18.5 kg (40.7 lbs) shipping.
Warranty: Three years.
APPROVALS
EMC: Conforms to EN50081-1
(Emissions) and EN50082-1 (Immunity). Safety: The oscilloscope has been designed to comply with EN61010-1 Installation Category (Over-voltage Category) II, Pollution Degree 2. UL and cUL approved: UL standard: UL 3111-1; cUL Canadian Standard CSA­C22.2 No. 1010. 1-92.
Copyright © January 1997
LeCroy is a registered trade­mark of LeCroy Corporation. All rights reserved. Information in this publication supersedes all earlier versions. Specifica­tions subject to change without notice.
MathCad is a registered
trademark of Centronics is a registered trade­mark of Data Computer Corp. Epson is a registered trademark of Epson America Inc. PowerPC is a registered trademark of Microelectronics
MATLAB is a registered trade-
mark of The MathWorks, Inc. DeskJet, ThinkJet, QuietJet, LaserJet, PaintJet, HP 7470 and 7550 are registered trademarks of Hewlett-Packard Company.
Datasheet DS93XXC 0198
MATHSOFT Inc.
IBM
ORDERING INFORMATION
Digital Oscilloscopes: Product Code
500 MHz, 500 MS/s, 50 kpts/ch, 2 or 4 channel DSO 9350C/9354C 500 MHz, 500 MS/s, 250 kpts/ch, 2 or 4 channel DSO 9350CM/9354CM 500 MHz, 500 MS/s, 500 kpts/ch, 4 channel DSO 9354CTM* 500 MHz, 500 MS/s, 2 Mpts/ch, 2 or 4 channel DSO 9350CL/9354CL
1 GHz, 500 MS/s, 50 kpts/ch, 2 or 4 channel DSO 9370C/9374C 1 GHz, 500 MS/s, 250 kpts/ch, 2 or 4 channel DSO 9370CM/9374CM 1 GHz, 500 MS/s, 500 kpts/ch, 4 channel DSO 9374CTM* 1 GHz, 500 MS/s, 2 Mpts/ch, 2 or 4 channel DSO 9370CL/9374CL
1 GHz, 1 GS/s, 100 kpts/ch, 4 channel DSO 9384C 1 GHz, 1 GS/s, 500 kpts/ch, 4 channel DSO 9384CM/9384CTM* 1 GHz, 1 GS/s, 2 Mpt/ch, 4 channel DSO 9384CL
Included with Standard Configuration:
935xC: 10: 1, 10 MPassive Probe (1 per channel) PP002 937xC/9384C: 10:1, 10 MPassive Probe (1 per channel) PP005 Operator’s Manual 93XXC-OM Remote Control Manual 93XX-RCM Hands on Guide 93XX-HG Floppy Disk Drive
PROBES & ACCESSORIES:
1 GHz 10:1 FET Probe AP020 15 MHz (±700 V) Differential Probe AP031 15 MHz (±1400 V) Differential Probe AP032 A Wide Range of Differential Amplifiers and Probes are available 50 MHz Probe AP015
2.5 GHz, 0.6pF FET Probe (x5) AP54701A** 8 GHz, 10:1, 500 Passive Probe (x10) PP063 1 GHz, 100:1, 5 kPassive Probe (x10) PP064 High Voltage Probe 2 kV, 400 MHz PPE2KV High Voltage Probe 20 kV (40 kV peak), 100 MHz PPE20KV SMD Kit for PP005 PK006 SMD Kit for AP020 PK106 Rackmount 93XX-RM01
SOFTWARE OPTIONS:
Advanced Waveform Math Package 93XX-WP01 Spectrum Analysis Package 93XX-WP02 Parameter Analysis Package 93XX-WP03 Disk Drive Measurements 93XX-DDM Supplementary Disk Drive Measurements 93XX-PRML Disk Drive Failure Analysis 93XX-DDFA
HARDWARE OPTIONS:
Memory Card Reader with 512K Memory Card 93XX-MC01/04 512K Memory Card 93XX-MC04 HD01/HD02 Combination 93XX-HDD Hard Disk Adapter 93XX-HD01 PCMCIA Hard Disk 170 MB 93XX-HD02 PCMCIA type III External Desktop Adaptor for PC (110V) 93XX-DA01-110 PCMCIA type III External Desktop Adaptor for PC (220V) 93XX-DA01-220 4 MB ATA Flash Card (requires HD01 option) 93XX-4MBFC Internal Graphics Printer 93X2-GP01 External Clock, Reference Clock and Trigger Comparator
Order as model number: 935XC-CKTRIG, 937X-CKTRIG, 938X-CKTRIG
MANUALS:
935xC Service Manual 935xC-SM 937xC Service Manual 937xC-SM 9384C Service Manual 9384C-SM
WARRANTY & CALIBRATION
Swiss OFMET Standard 93XX-CCOFMET US NIST Standard 93XX-CCNIST 5 Year Warranty 93XX-W5 5 Year Calibration Contract 93XX-C5 5 Year Warranty and Calibration 93XX-T5
* Includes WP01, WP02 and graphics printer ** Requires AP1143A
Sales and Service Throughout the World
Corporate Headquarters
700 Chestnut Ridge Road Chestnut Ridge, NY 10977 USA
http://www.lecroy.com
LeCroy Sales Offices:
Asia South: Australia Phone (61) 3 9890 7358 FAX (61) 3 9890 8754
Asia North: Hong Kong Phone (852) 2836 7361
AX (852) 2836 7007
F
France: Les Ulis Phone (33) 1 69 18 83 20 F
AX (33) 1 69 07 40 42
Germany: Heidelberg Phone (49) 6221 827 00
AX (49) 6221 834 655
F
Italy: Venice Phone (39) 41 456 97 00 F
AX (39) 41 456 95 42
Japan: Osaka Phone (81) 6 396 0961
AX (81) 6 396 0962
F
Japan: Tokyo Phone (81) 3 3376 9400
AX (81) 3 3376 9587
F
Japan: Tsukuba Phone (81) 298 41 5810 F
AX (81) 298 41 5830
Switzerland North: Niederlenz Phone (41) 62 885 8050 FAX
(41) 62 885 8055
Switzerland West: Geneva Phone (41) 22 719 2228 FAX
(41) 22 719 2230
U.K.: Twyford Phone (44) 1189 344 882 FAX
(44) 1189 348 900
U.S.A.: Chestnut Ridge Phone (1) 914 578 6020 F
AX
(1) 914 578 5985
Loading...