Leader Light LL46 400 User Manual

Leader Light s.r.o.
SK-052 01 Spisska Nova Ves
M.Gorkeho 33
Slovakia
www.leaderlight.eu
USER MANUAL
LL PRO LED SPOT DC24V Z-POWER OneChip RGB
LL46 400
COMPLIMENTS ON YOUR PURCHASE!
01 SAFETY INFORMATION
WARNING!!!
Carefully read before installing, powering or servicing. Nothing to do if anything misunderstand! Only for professional use!
01.1 Risk of eyes damage
03 INSTALLATION
03.1 Unpacking
- Unpack carefully.
- This is electronic equipment and should be handled carefully.
- Damaged delivered package or if are any mechanical parts immediately by the transport company.
Photo pictures as evidence are valuable for future claim.
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all device clusters
- (luminaries, clamps, cables, ...).
- Heigrbreadth from combustible materials is 0,5m.
broken – it must be claim
All dimensions are in milimeters
max.121
Φ
120
- Do not look directly into LED lamps.
- Do not look into light beam from a distance of less than 40 cm (16 inches)!
01.2 Protection from electric shock
max.196
- Shut down power before installation or maintenance.
- Luminaries, Drivers and recommended power supply must be installed by a qualified professional in
accordance with relevant local codes. Only acceptable source of AC power and frequency that complies with local buidling and electrical codes to use.
- Do not use or do not connect the products if the power cable, power plug or fixtures are any way
damaged, wet, or if they are overheating.
- Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the warranty.
Following items are included:
- LL PRO LED SPOT with 5 m cable and XLR 6PIN connector 1 pc.
- User manual 1 pc.
Additional items needed:
- LL PRO LED Z-POWER DRIVER
- DMX controller
01.1 Risk of eyes damage
01.2 Protection from electric shock
01.3 Fire prevention
02 PRODUCT SPECIFICATION
02.1 Technical Specification
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connecting to AC/DC power supply
04 MAINTENANCE
ENVIRONMENT
Do not throw away the appliance with the normal household waste at the end of its life,
but hand it in at an official collection point for recycling. By doing this, you help to preserve
the environment.
©MMVIII - Leader Light – All right reserved If you have any question please, contact support@leaderlight.sk
- Before removing or installing any cover or part of appliance disconnect it from AC power.
01.3 Fire prevention
- Follow all safety consideration.
- Thermostatic switches or fuses never to bypass.
- Device never shield. Around the axis of the fitting (180°) must be maintained space for cooling. Minimum distance from the surrounding objects must be 50mm (2 in.) (figure 1.1).
- LEDs never direct cover with filters or other materials.
- Allowing max. ambient temperature is 40°C (104°F).
- Luminaries never use without mounting brackets. The housing never install directly to the surface.
02 PRODUCT SPECIFICATION
02.1 Technical Specification
Lamp type:
Lifetime:
Control data Input:
Input power:
DC Power Connection:
Net weight:
Dimensions LxHxΦ:
Ambient temp. (Ta):
Cooling:
Materials and finish:
Installation:
12xRGB 3x1W P5 (Red, Green and Blue)
Long 60 000 hrs 60% degradation
Optic:
35mm standard 25° optional 40°- on request
3 channels 24V dimming
max. 50W
24V DC 5m cable with XLR 6PIN
2,5kg
max. 121mm x max. 196mm x 125mm without bracket
IP:
IP65
Maximum 40°C
Conventional
Housing: powder-painted anodized aluminium in black (other colours on request) Cover: clear or frosted PMMA
Any position for ceiling, wall and surface mounting
Edition: A - 2008
03.3 Connecting to DC power supply
- To tackle all Safety Information- 01!
- You can suffer a dangerous electric shock by using a high voltage AC/DC power supply - by touching AC/DC power supply the wires inside the unit!
- LL PRO LED SPOT operate with the LL PRO DRIVER IN:100-260AC/ OUT: 24V (Figure Nr. 2.1, 2.2).
- It is not necessary to open the fixture before connecting to LL PRO DRIVER.
- Pull the XLR 6PIN cable connector from fixture to the LL PRO DRIVER.
AC Power Supply Cord plug connections to LL PRO DRIVER:
Symbol Pin Wire Colour Screw (US)
L live brown yellow or brass
N neutral blue silver
ground (earth) yellow/green green
04 MAINTENANCE
- To tackle all Safety Information- 01!
- Damage caused by inadequate cleaning or maintenance is not coverd by warranty.
- Regular cleaning is demand (dust, dirt, ...).
Maintenance policy:
- Unplug mains befor maintenance and at least 10 minutes cool off.
- Cleanup dust from cover.
- Use dampy duster (warm watter).
- Before reinstalling to check failure-free state – no wet parts!
Order code Product name Current
LL46 400 LL PRO LED SPOT OneChip RGB 3x0,7A
LL PRO LED SPOT connecting to PWM DRIVER 12
DC 24V
LL PRO LED SPOT connecting to PWM DRIVER 36
DMX
CONTR.
4 GROUPs: XLR 6PIN
max. 12A
DRIVER 12
100-260V AC
3 x 4 GROUPs: XLR 6PIN max. 40A
Detail: LL PRO LED DRIVER 12
2.1
INSTALLATION
Ventilation space 180° free
minimal.
50mm
Minimal mounting distance from surface
WARNING!!!
!!
Non-minimum distance and / or non-use the original brackets is at your own risk!
minimal.
50mm
Ventilation space 90° free
minimal.
50mm
minimal.
100mm
1.1
MOUNTING
90°
Aiming possibility
The fixture could be aim to wish position with
bracket.
DC 24V
DMX
CONTR.
Detail: LL PRO LED DRIVER 36
DRIVER 36
100-260V AC
2.2
If you have any question please, contact support@leaderlight.sk