LEADER Video Test Instruments Catalog 2008-2009

Page 1
Page 2

COMPANY PROFILE

LEADER Since LEADER
ELECTRONICS CORP. was established in 1954, has focused its attention on international markets. LEADER established local corporations in U.S.A. in 1969 and Hong Kong in 1980. Many other positive measures have also been taken before other companies. In July 1995, LEADER's own service center was set up in Shanghai for better service/maintenance in China. In 2003, Regional Offices were established in Beijing and Dongguan to support LEADER products, which are becoming increasing popular in view of the growing Japanese presence in China. In 2005, The Technical Service Center was established in Beijing. LEADER ELECTRONICS is keeping abreast of the times with the establishment of LEADER ELECTRONICS EUROPEAN OFFICE in The Netherlands in 2006. LEADER ELECTRONICS now has a global network linking its agents in 62 countries/areas.
Audit and Registration of ISO9001 and ISO14001, the internal standard for Quality and Environmental Management Systems
The electronic measuring instrument, the mother tool of electronics, consistently requires the highest technology and quality. The history of LEADER ELECTRONICS CORP. is indeed the history of the pursuit of higher technology and quality. In December 1994, we received an audit and successfully registered ISO9001, the international standard for quality management systems, and furthermore, as our basic policy of product development considering the environment, we received an audit and successfully registered ISO14001 in April 2007, that is the international standard for an environmental management system. It gives us great satisfaction to offer products manufactured with outstanding technologies and quality, and moreover, to contribute to society through activities that take into consideration the environment.
Company name
LEADER ELECTRONICS CORP.
Headquarters
2-6-33 Tsunashima-Higashi, Kohoku-ku, Yokohama 223-8505, Japan Phone: 81-45-541-2123 Fax: 81-45-541-2823
Headquaters annex
2-6-21 Tsunashima-Higashi Kohoku-ku, Yokohama 223-0052, Japan
Factory 1
6-11-28 Tsunashima-Higashi Kohoku-ku, Yokohama 223-0052, Japan
Factory 2
5-10-35 Tsunashima-Higashi, Kohoku-ku, Yokohama 223-0052, Japan
Headquarters
Headquaters annex
Factory 1
Factory 2
2
Page 3
3
Fuji Television Wangan Studio in Tokyo
ABC Studio in New York
Page 4
4
Selection
Guide
Waveform Monitor
※1 LV7720(SDonly) ※2 EyePattern(option) ※3 Option73A
Signal Generator/SDI System Margin Checker
Page 5
5
Video
Test Instruments
Dean Krueger, DP & DIT
LV 5750 in use on the set.
Page 6
6
MULTI SDI MONITOR
LV 5380
The LV 5380 is a multi-SDI monitor equipped with a precision video signal waveform and vectorscope display via a high­fidelity TFT LCD that produces high-quality picture displays. It also offers an embedded audio signal display featuring Lissajous and level-meter configurations. Additional features include simultaneous display of two SDI signals, screen cap­ture to USB memory, and on-picture gamut error monitoring. All these features are integrated into a thin, light instrument that allows it to be used in any video production or monitoring application.
FEATURES
High-Quality TFT LCD
Employs an XGA TFT LCD (1,024x768) that produces high­quality picture displays.
• Extensive Video Signal Displays
The waveform monitor display has gain adjustment, sweep, and cursor measurement features along with RGB and pseudo-composite information. The LV 5380 also provides vectorscope and embedded audio Lissajous and Level­meter displays.
• Multi-Functional Picture Display
The picture display has various adjustment features such as color temperature selection, brightness, contrast, gain, and bias. Other features include monochrome, chroma up, on­image gamut error, and safety marker displays.
Multi-Screen Display and 2-Channel Simultaneous Display
1)You can switch to multi-screen which simultaneously shows video signal waveforms and pictures.
2)You can switch to multi-screen which simultaneously shows video signal waveforms, picture, vectorscope, and audio levels.
3)You can display two SDI signals simultaneously.
• Dual link input *1
• Status Display
The LV 5380 can display SDI signal's data dump and error logs as well as the phase difference between the external sync signal and SDI signal.
•Display Mode Switch Keys
For quick operation, the LV 5380 provides dedicated keys for switching between different display modes such as video waveform, vectorscope, and picture displays. In addi­tion, all keys can be back-lit.
• Stereo Headphone Output
Delivers SDI signal's embedded audio signals in stereo through the headphone output jacks.
• External Sync Signal Input
Accepts tri-level sync signals or NTSC/PAL black burst signals.
• Presets
Stores up to 30 front panel presets.
• Last Memory
Equipped with a feature that stores panel settings to memory.
• 75-mm VESA Mounting
Provides 75-mm VESA mounting holes on the rear panel that allows the LV 5380 to be mounted on an arm or stand. Tripod mounting facilities also provided.
• External Remote Connector (Factory Option)
An external remote connector can be installed as a factory option. In addition, one of the connectors can be modified so that a tally indicator can be displayed on the screen.
Battery Mount (Factory Option)*2
A battery adapter can be installed on the rear panel as a factory option.
• OP73 : BATTERY MOUNT IDX (V-Mount)
• OP74 : BATTERY MOUNT ANTON (AntonBauer)
OP70: Cinelite II (Cinelite+Cinezone) (Option)
Leader's CINELITE and CINEZONE features are added as a single option in this instrument. For details on CINELITE & CINEZONE, please see page #49.
*1 To be supported in the future *2 If you install the battery mount, you cannot use the 75-mm VESA mounting holes.
Compact Multi-SDI Monitor
8.4 Inches
The design is subject to change.
4U size
option
Page 7
7
LV 5380 SPECIFICATIONS
Video Formats and Corresponding Standards
Audio Display
Compliant Standard Quantization Synchronization Channel Selection
Input/Output Connectors
SDI Input
Input Connectors Input Impedance Input Return Loss Maximum Input Voltage
SDI Output
Output Connector
Output Impedance Output Voltage Maximum Return Loss
External Reference Input
*1
Input Signal Input Connectors Input Impedance
Headphone Output
Output Signal
Sampling Frequency Output Connector Impedance
LCD
LCD Type Backlight Brightness Auto Shutoff
Screen Capture
Capture
Waveform Comparison
Data Output
Data Input
Presets
Display Mode Presets Number of Presets
Waveform Display
Waveform Operation
Display Mode
Overlay Display
Parade Display Blanking Period RGB Conversion Pseudo-Composite Display
Channel Assignments
Line Select
Vertical Axis
Gain Variable Gain Amplitude Accuracy Frequency Characteristics HDTV
Y Signal
C
B, CR Signals
Low-Pass Attenuation Frequency Characteristics SDTV
Y Signal
CB, CR Signals
Low-Pass Attenuation
Horizontal Axis
Line Display Field Display
Cursor Measurement
Types
Amplitude Measurement Time Measurement Frequency Display
Scale
Type Color Thumbnail Display
Vectorscope Display
Gain Variable Gain Amplitude Accuracy Scale
Type IQ Axis Color
Pseudo-Composite Display
Thumbnail Display
5 Bar Display
Bar Display Channel Assignments Scale Error Level
SMPTE 299M (HD-SDI), SMPTE 272M (SD-SDI) 20 bits Must be synchronized to all video clocks Two groups (eight channels in the same SDI channel) selec­table
Two BNC connectors 75 15 dB 5 MHz to the serial clock frequency ±2 V (DC + ACpeak)
One BNC connector Reclocks and transmits the selected SDI input signal 75 800 mVp-p ± 10 % 15 dB 5 MHz to the serial clock frequency
Tri-level sync or NTSC/PAL black burst One pair of BNC connectors 15 kpassive loop-through
Extracts and transmits the embedded audio signal (when synchronized to the video signal) Supports 48 kHz One stereo miniature jack 16
8.4-inch color XGA TFT. Effective area 1,024 x 768 dots 32 adjustable levels Time to turn off the LCD can be set.
Captures the screen to an image file Superimposes the input signal over an image from memory. Screen captures can be saved as bitmap files to USB memory or to a PC over the Ethernet. Data saved to USB memory can be loaded and displayed on the LV 5380.
Only stores settings specific to each display mode 30 total. Display Mode Presets:Five presets for each display mode.
Overlays component signals Displays component signals side by side H and V blanking periods can be masked Converts Y, CB, CRsignals into RGB and displays the result Digitally converts component signals into composite signals and displays the result The G, B, R order or R, G, B order selectable for RGB con­version display Displays the selected line
x1 or x5 selectable x0.2 to x2.0
±0.5 %
±0.5 % for 1 to 30 MHz±0.5 % for 0.5 to 15 MHz20 dB (at 20 MHz)
±0.5 % for 1 to 5.75 MHz±0.5 % for 0.5 to 2.75 MHz20 dB (at 3.8 MHz)
x1, x10, x20, ACTIVE, or BLANK selectable x1, x20, or x40 selectable
Two horizontal cursors (REF and DELTA) Two vertical cursors (REF and DELTA) Measures in % or V Measures in usec or msec Displays the frequency by assuming the interval between the cursors to be one period
% scale or V scale selectable Selectable from seven colors Can display thumbnails of picture displays and audio level meters
x1, x5, or IQ-MAG selectable x0.2 to x2.0 ±0.5 %
75 % or 100 % selectable Show or hide selectable Selectable from seven colors Digitally converts component signals into composite signals and displays the result Can display thumbnails of picture displays and audio level meters
Displays the peak levels of Y, R, G, B, and composite RGB or GBR selectable mV or % selectable Based on gamut error level and composite gamut error level settings, user settable.
Picture Display
Color Temperature Quality Adjustment Display Size Color
Frame Rate
Aspect Marker Display Aspect Marker Format Safety Marker Size Line Select Gamut Error Display Thumbnail Display
Embedded Audio Display
Lissajous Display
Display Channels Display Mode
Level Meter Display
Display Channels Meter
Channels
Group Selection
Audio Information Detection Sampling Frequency
Status Display
Event Log Data Dump Display Data Output
Phase Difference Display
Display
Display Range
Vertical
Horizontal
Error Count
Error Count
Count Period Video Errors
CRC Error EDH Error
Gamut Error
Gamut Error
Detection Range Upper Limit
Lower Limit
Composite Gamut Error
Detection Range Upper Limit
Lower Limit
Audio Errors
CRC Error BCH Errors
Time Display
Current Time Display Elapsed Time Time Code
Other Display Features
ID Display Tally Indicator
Front Panel
Key LEDs Last Memory
Environmental Conditions
Operating Temperature Operating Humidity Range Operating Environment Overvoltage Category
Pollution Degree Power Requirements Dimensions
Weight Accessory
Option Sold Separately
6500K or 9300K selectable Brightness, contrast, gain, bias, aperture Fit, full frame, real, and 4:3 full screen R, G, or B can be turned off separately. Variable chroma gain and monochrome available. Displays by converting the frame rate using the internal sync signal 4:3, 13:9, 14:9, or 16:9 selectable Line, shadow (three types), black ARIB TR-B4, SMPTE RP-218, or user-defined selectable Displays a mark on the selected line Displays gamut error locations over the picture Displays thumbnails of audio level meters
2ch (single) or 8ch (multi) selectable X-Y or L-R selectable
2ch or 8ch display selectable 60 dB peak level, 90 dB peak level, or average selectable. (Peak level meters include setable peak hold indication.)
Select any two groups within the same SDI channel from groups 1, 2, 3, and 4 Detects the presence of each audio channel 48 kHz (must be synchronized with the video signal)
Stores up to 1,000 events Dumps data by serial data sequence or by channel Can be saved in text format to USB memory or to a PC
Displays numerically and graphically the phase difference between an SDI signal and the external sync signal
±1 field (for interlace) ±1/2 frame (for progressive) ±1 line
Counts up to 999,999 video, audio, and gamut errors separately Counts all errors that occur in one field as one error
Detects transmission errors of HD-SDI signals Detects transmission errors of SD-SDI signals
Detects gamut errors
90.0 to 109.4 %
-7.2 to +6.1 % (0.1 % steps) Monitors level errors when component signals are converted to composite signals
90.0 to 135.0 %
-40 to -20 % (0.1 % steps)
Detects CRC errors in channel status bits Detects transmission errors of HD-SDI audio packets
Time display based on the internal clock Time elapsed since the error count was cleared LTC or VITC selectable (complies with SMPTE RP-188)
ID can be assigned to each input channel. One of the remote connectors can be modified so that tally indication can be shown on the screen (to be supported in the future).
All keys illuminate dimly. (The selected key illuminates brightly.) Backs up panel settings to memory
0 to 40 ºC 85 % RH (without condensation) Indoors I 2
10 to 18 VDC, 30 W max. 215 (W) x176 (H) x 85 (D) mm (excluding projections)
8 1/2(W) x 6 15/16(H) x 3 3/8(D) in. (excluding projections)
2.0 kg, 4.5 lbs
Instruction manual.................................................................1
Ferrite Core ...........................................................................1
AC adapter LP 1960 Rack mount LR 2751 I Blank Panel LC 2129
Format Quantization Scanning Frame (Field) Frequency
Corresponding Standard
Y, C
B, CR 4:2:2 10bit 1080i 60/59.94/50 SMPTE 274M
1080p 30/29.97/25/24/23.98 SMPTE 292M 1080PsF 30/29.97/25/24/23.98
SMPTE RP211 SMPTE 292M
720p
60/59.94/50/ SMPTE 296M 30/29.97/25/24/23.98 SMPTE 292M
525i 59.94
SMPTE 259M
625i 50
• The video signal waveform display and vectorscope display may be delayed by up to 1 frame with respect to the picture display.
•V sweep cannot be displayed when the video signal waveform displays for two simultaneous inputs are shown.
• Phase difference accurary between external reference and internal signal is ±1 clock cycle.
Cinelite Cinezone
*1
      
Cinelite II (Option)
Page 8
8
LV 5380 DISPLAY
Picture Display
Versatile Picture Display
Picture adjustment options include color temperature (6500K/9300K), brightness, contrast, gain, bias, and aperture. You can switch the R, G, and B signals on and off.
Picture adjustment menu Picture and waveform time axis correspondence
Multi-Screen Display Waveforms Y RGB Display Audio Display
Phase Difference Display
Data Dump Status Aperture
Composite Display 5 Bar/Picture/Gamut Gamut Error Display
Video Waveform Color Selection Various Markers Line Selection
Whitedisplay Greendisplay
Marker display menu
ON
Changes the color of gamut error areas in the picture display.
OFF
Page 9
9
LV 5380 REAR PANEL
ExternalDimensions
RackMounting
215 mm.
8.46 in.
85 mm.
3.35 in.
75 mm.
2.96 in.
47.5 mm.
1.87 in.
20
mm.17mm.
48
mm.
0.79 in.
1.89 in.
0.67 in.
176 mm.
6.93 in.
155.2 mm.
6.11 in.
75 mm.
2.95 in.
34.2 mm.
1.35 in.
10.4 mm.
0.41 in.
10.4 mm.
0.41 in.
FIT Display Size (with audio levels) REAL Display Size
(pixel to pixel correlation)
MONOCHROME Display
ACAdapterLP1960(soldseparately)
LV 5380 dual mount example
LR 2751 I Rack Mount (sold separately; tiltable) LC 2129 Blank Panel (sold separately)
Page 10
10
MULTI SDI MONITOR
LV 5330
The LV 5330 is a compact and lightweight multi-SDI test moni­tor specifically designed for oncamera and portable applica­tions. Picture, waveform, vector, audio and status screens can be displayed individually or in multi-screen representations. The instrument is also equipped with on-picture measurement functions, Cinelite and Cinezone, and helps facilitate measure­ments that are easily understood by both technical and opera­tions personnel. High-accuracy measurement and monitoring facilities also include settable error level monitoring and alarms as well as extensive data analysis. A screen capture function facilitates communication between production and post production personnel and aids in project documentation.
FEATURES
Two Serial Digital Inputs
Two SDI input connectors (channels A and B) support HD-SDI and SD-SDI signals. The selected SDI input is passed through an SDI output connector to facilitate switched monitor output opera­tion.
• Display
A built-in 6.5-inch XGA TFT LCD (1,024x768) provides brilliant and clear representations of waveforms, vectors, pictures, audio level meters, status, etc. The multi-screen feature allows these displays to be shown simultaneously in tiled windows.
• Picture display
Brightness, contrast, and saturation is adjustable and aspect ratio, safe action and safe title markers can be displayed. The edge enhancement feature provides visual assistance with focus.
• Cinelite II (Cinelite and Cinezone)
The Cinelite on-picture measurement feature displays the lumi­nance of any three user definable points and provides luminance measurements in %, RGB levels (or %) as well as in f-stops. The Cinezone feature uses false-colors to represent luminance values on the display enabling quick confirmation of the luminance dis­tribution levels on the display.
• Waveform Monitoring
Parade, overlay, Y C
B CR, RGB, and pseudo-composite displays
are available.
• Vectorscope
Vectorscope display is available and accommodates both 75 % and 100 % saturation levels; pseudo-composite vectorscope dis­play is also available.
•5 Bar Display
The 5 Bar display enables simultaneous monitoring of compo­nent and composite gamut.
• Line Selector
Selects any line of the video signal to be displayed and provides waveform, vector and 5-bar representations of the selected line. A line marker on the picture facilitates visual selection of the appropriate line.
• Audio Level Meter
Up to 8 channels of embedded audio signals can be displayed using audio bar level meters.
*The SD-SDI audio quantization precision is up to 20 bits.
• Viewfinder
The camera's composite video output (in NTSC or PAL) can be shown on the picture display. The edge enhancement feature assists you in focusing the camera.
• Screen Capture
The displayed screen can be captured and saved to internal mem­ory or USB memory.
• Extensive Analysis Features
Various types of error detection
SDI signal event log
Digital data dump
• Flexible Control
Instrument can be remote controlled from a PC over an
Ethernet network.
Internal memory holds up to 30 presets allowing quick access to your favorite instrument setups. Personalize your LV 5330 by loading your own custom presets via USB thumb-drive.
• External Synchronization
Accepts tri-level sync or NTSC/PAL black burst signals.
• Stereo Headphone Output
Extracts embedded audio signals and sends 2 user selectable audio channels to the headphone jack.
• Panel LED Illumination
You can illuminate all of the panel keys; a useful feature when working in a dark environment.
• Power Supply
XLR DC input connector is provided; accepts 12Vdc- 18Vdc. A V-mount battery adapter is also available as a factory option.
• Tripod Mounting
A Screw(1/4.in) hole attaching a camera tripod is provided on the bottom panel of the LV 5330.
• Battery Mount (Factory Option)
A battery adapter can be installed on the rear panel as a factory option.
BATTERY MOUNT IDX (V-MOUNT)*1
BATTERY MOUNT ANTON (AntonBauer)
*1 To be supported in the future
Compact, Slim & Lightweight Multi-SDI Test Monitor
6.5 Inches
1.3 kg
The design is subject to change.
215 mm
63 mm
128 mm
Page 11
11
LV 5330 SPECIFICATIONS
Video Formats and Corresponding Standards
Other Standards
Ancillary Data Standard Embedded Audio Standard
Format Setting
Format Setting Sampling Frequency
External Synchronization
Input/Output Connectors
SDI Input
Input Connector
External Reference Input
Input Signal Input Connector
SDI Output
Output Connector
Output Voltage
Headphone Output
Output Signal Sampling Frequency
Output Connector
USB Memory
Function
Remote Control
Function Connector
Ethernet
Function
Type:
Viewfinder Input
Function Input Signal Input Connector
Picture Display
HDTV Display SDTV Display Display Frame Rate
Marker Display
Adjustment:
Cinelite Display
f-STOP:
Measurement points Reference
%DISPLAY
Measurement points Measurement areas GAMMA
0.45
USER 1-3
USER A-E On Picture Level Indicator
Cinezone Display
Screen
UPPER
LOWER
Display Form
Display Size
1 Screen Display
2 Screen Display
SMPTE 291M SMPTE 299M (HD-SDI), SMPTE 272M (SD-SDI)
Auto or manual setting from the supported formats
74.25 MHz (HDTV), 74.25/1.001 MHz (HDTV),
13.5 MHz (SDTV) Auto setting from supported formats
Two BNC connectors (switching between A and B)
Tri-level sync or NTSC/PAL black burst One pair of BNC connectors (15 kpassive loop-through) *
Phase difference accurary between external reference
and internal signal is ±1 clock cycle.
One BNC connector (reclocks and transmits the selected SDI input signal) 800 mVp-p±10 % outputs (75
)
Extracts and outputs the embedded audio signal. Supports 48 kHz (must be synchronized to the video signal) One stereo miniature jack, 32
(16 to 600 Ω)
Stores screen captures, error logs, preset data, and data dumps, Also used for Firmware update.
Recalls presets, transmits errors, controls the tally indicator D-sub 15-pin female
Enables remote control from an external computer and data transmission 10BASE-T/100BASE-TX auto switching, one RJ-45 jack
Monitors composite video signals, picture only. NTSC/PAL VBS signal One BNC connector
Displays by sampling pixels Displays by interpolating pixels Color or black and white selectable Displays by converting the frame rate using the inter­nal sync signal Center marker, aspect marker, safe title marker, safe action marker Brightness, contrast, chroma, aperture
Measures relative brightness in f-stops Three points specified using the cursor Uses an object with an 18 % reflectance as reference Displays luminance percentage (LEVEL%), RGB per­centage (RGB%), and RGB numeric values Three points specified using the cursor 1x1, 3x3, 9x9
Reference gamma User-defined gamma Gamma downloaded from USB memory Switches the screen to black and white and displays the set luminance level in green
Maps colors based on luminance levels. Linear or step selectable. Can be set from -6.3 % to 109.4 %. Displays white when the level is above the set level. Can be set from -7.3 % to 108.4 %. Displays Black when the level is below the set level.
6.5-inch color XGA. Effective area 1024 x 768 dots Picture display, Cinelite display, Cinezone display, waveform display, vectorscope display, status dis­play, viewfinder display Picture and waveform displays, waveform and vec­torscope displays, waveform and picture displays, waveform and audio level displays, audio numeric and bar displays
4 Screen Display
Waveform Display
Waveform Operation
Display Modes Timing Display
EAV-SAV period G, B, R Conversion
Pseudo-Composite Display
Channel Assignments
Vertical Axis
Gain Variable Gain
Amplitude Accuracy Frequency Characteristics HDTV
Y Signal C
B, CR signals
Frequency Characteristics SDTV
Y Signal C
B, CR signals
Horizontal Axis
Line Magnification Field Magnification
Cursor Measurement
Horizontal Cursors Vertical Cursors Amplitude Measurement Time Measurement Frequency Display
Marker Display
75 % Marker
Vectorscope Display
Scale Gain Variable Gain
Amplitude Accuracy IQ Axis Pseudo-Composite Display
5 Bar Display
Bar Display
Embedded Audio Display
Display Channels Meter Group Selection Channel Mapping
Viewfinder
Display Size Adjustment
Status
Data Dump Display Event log Data output
Screen Capture
Waveform Comparison Presets Other Display Features
LCD
Backlight brightness Screen Display Panel LED Illumination
Environmental Conditions
Operating Temperature Operating Humidity Range Operating Environment Overvoltage Category Pollution Degree
Power Requirements Dimensions and Weight
Accessory Option Sold Separately
Audio level display or status display selectable in addition to waveform display, vectorscope display, and picture display
Overlay and parade Displays by calculating Y-C
B and Y-CR
Uses bowtie signals (authorized by Tektronix, Inc.) Show or hide selectable Converts Y, C
B, CR signals into G, B, R and displays
the result Digitally converts component signals into composite signals and displays the result The G, B, R order or R, G, B order selectable for G, B, R conversion display
x1, x5, or variable selectable x0.2 to x2.0 at the x1 setting, x1.0 to x10.0 at the x5 setting
±0.5 %
±0.5 % 1 to 30 MHz±0.5 % 0.5 to 15 MHz
±0.5 % 1 to 5.75 MHz±0.5 % 0.5 to 2.75 MHz
x1 or x10 selectable x1, x20, or x40 selectable
2 (REF and DELTA) 2 (REF and DELTA) Measures in % or V Measures in usec or msec Displays the frequency by assuming the interval between the cursors to be one period
Indicates the value corresponding to the peak chromi­nance signal of the 75 % color bar.
75 % or 100 % selectable x1, x5, IQ-MAG, or variable selectable x0.2 to x2.0 at the x1 setting, x1.0 to x10.0 at the x5 setting ±0.5 % Show or hide selectable Digitally converts component signals into composite signals and displays the result
Displays the peak levels of Y, R, G, B, and composite
8-channel simultaneous display 60 dB peak level or 90 dB peak level Select any two groups from groups 1, 2, 3, and 4 Mapping to L, R, SL(S), SR, C, LFE, RL, RR
Full-screen display Brightness, contrast, chroma, aperture
Dumps data by serial data sequence or by channel Stores up to 1,000 events To USB memory or over an Ethernet network
Captures the displayed screen Superimposes the input signal over an image from memory.
30
6.5-inch color LCD High or low selectable Format, color system, date, time Illuminates all keys
0 to 40 ºC 85 %RH (no condensation) Indoors, or outdoors with no rain I 2
12 VDC (10 to 18 V), 18 Wmax. 215 (W) x128 (H) x 63 (D) mm (excluding projections), 1.3 kg
8 1/2 (W) x 5 3/64 (H) x 2 31/64(D) in. 2.9 lbs
Instruction manual......................................................1
AC adapter LP 1960
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
1080i/60 1080i/59.94 1080i/50 1080p/30 1080p/29.97 1080p/25 1080p/24 1080p/23.98 1080PsF/30 1080PsF/29.97 1080PsF/25 1080PsF/24 1080PsF/23.98 720p/60 720p/59.94 720p/50 720p/30 720p/29.97 720p/25 720p/24 720p/23.98 525i/59.94 625i/50
Format
SMPTE 274M, 292M
SMPTE RP211, 292M
SMPTE 296M, 292M
SMPTE 259M
Corresponding Standard
Cinelite Cinezone
Cinelite II
Page 12
MULTI MONITOR
LV 5800
Your Desired combination of units allows a flexible waveform monitor
The LV 5800 is a new type of multi monitor that allows you freely configure various input and output units according to your application. You can construct a versatile system by combining dedicated input and output units. In particular, simultaneous display and error monitoring of multiple SDI inputs are possible, and four-waveform parade display on the waveform monitor is also supported.
FEATURES
Four Input Slots
Up to four input units can be inserted. Each input unit operates
independently.
Two Output Slots
Up to two output units can be inserted. Each output unit operates independently.
Display Function
Employs a color TFT LCD monitor with XGA resolution (1,024 x 768). The display function of each unit can be displayed on a full screen or 4 screen multi display. The 4 screen display allows arbitrary combination of signals of different input units to be displayed.
Capture Function
In addition to simply displaying the image data, this cap­ture function allows you to superimpose the input signal
Unit List
and the captured data views,allows you to save the data to USB memory and to reload the data into the LV 5800 later, and allows you to view the captured data as bitmap data on a computer.
Ethernet Connector
Remote control through TELNET or FTP, error monitoring, and file transfer are possible by connecting a PC to the Ethernet connector on the rear panel.
Remote Connector
The remote connector on the rear panel allows recalling of presets, detection of errors, and switching of inputs.
Low Noise Cooling System
Equipped with a low noise fan. Fan speed controlled using a temperature sensor. If the fan stops due to a malfunction, an alarm can be displayed on the screen through the revo­lution sensor.
Headphone Socket
Sound can be monitored when the LV 58SER40A is installed.
LV 5800 REAR PANEL
Please use exclusive cabi­net for Model LV 5800 (pho­tograph shows LR 2427B) The Panel design is subject to change. The cabinet is sold separately.
LV 58SER20/LV 58SER40A/LV 58SER02/LV 58SER01A x 2 for installation example
PATENTED:
Equivalent cable length measurement
12
option
LV 58SER01A
SDI INPUT
LV 58SER02
EYE PATTERN UNIT
LV 58SER03
COMPOSITE VIDEO UNIT
LV 58SER04
MPEG DECODER
LV 58SER20
DVI-I OUTPUT UNIT
LV 58SER40A
DIGITAL AUDIO
AFD Ready
Page 13
13
LV 5800 SPECIFICATIONS
Slot
Number of Slots for Input Number of Slots for Output
LCD Display
LCD Screen Type Display Format Frame Frequency
Backlight Brightness Auto Shutoff
Display Screen
Screen Capture
Capture
Waveform Comparison Media Format
Data Output
Presets
Number of Presets Media Recall Method
Copy
External Reference Input
Input Signal Input Connector Input Impedance Input Return Loss Maximum Input Voltage
4 2
6.3-inch TFT color XGA Effective area 1024 x 768 dots
59.94 MHz (The input signal and the display clock signal have not been synchronized.) Selects HIGH or LOW Sets the time for the backlight to shutoff automat­ically. 1-screen display, 2-screen display, 4-screen display
Image capture by the still picture of the display screen Superimposes the input signal over an image from memory. Internal memory (RAM) or a USB memory TIF, DPX
Save displayed test screens or full-frame cap­tures in various formats, including BMP, DPX, and TIFF. Save data to a PC via a USB memory or Ethernet network.
60 Internal memory (RAM) or a USB memory Through the front panel, remote connector, and Ethernet network (Switches 8 points and 60 points for recalling through the remote connector.) Copies presets collectively to the USB memory or from the USB memory to the LV 5800.
Tri-level sync signal or NTSC/PAL black burst BNC connector 1 system 2 connectors 15 kPassive Loop-through 30 dB ±5 V (DC + peak AC)
External Control Connector
USB Connector
Specifications Function
Ethernet Connector
Corresponding Standard Input/Output Connector Function
Type
Remote Connector
Function Control Signal Control Connector
Headphone Output
PHONES connector Function
Environmental Conditions
Operating Temperature Operating Humidity Operating Environment Operating Altitude Overvoltage Category Pollution Degree Power Requirements
Dimensions and Weight
Accessories
USB2.0 Only a large capacity memory device is supported.
IEEE802.3 RJ-45 Remote control from an external computer and monitoring of errors, etc. 10BASE-T/100BASE-TX
Recalling of presets, monitoring of errors LV-TTL level (LOW active) 25-pin D-sub (female)
Miniature jack (stereo) Like LV 58SER40A (DIGITAL AUDIO), it is effec­tive when the unit that has audio decoding func­tion is inserted.
0 to 40 °C 85 % RH(without condensation) Indoor use Up to 2,000 m II 2 90 to 250 VAC 50 Hz/60 Hz, 150 Wmax.
215(W) x 133(H) x 449(D) mm 5 kg 8 1/2(W) x 5 1/4(H) x 17 11/16(D) in 11 lbs
Power cord .......................................................1
Cover/Inlet stopper...........................................1
Screws for rack mounting
(inch specification)...........................................2
Instruction manual............................................1
25-pin D-sub connector ...................................1
25-pin D-sub connector cover .........................1
EX, LV 58SER01A 2 sets are installedEX, LV 58SER01A 2, LV58SER02
1 sets are installed
EX, LV 58SER01A 2 sets are installed EX, LV 58SER01A/LV 58SER02 1 sets
each are installed
EX, LV 58SER01A 2 set are installed (4Y PARADE)
EX, LV 58SER01A 1 set is installed EX, LV 58SER01A 2 set are installed
EX, LV 58SER01A 2 set are installed
EX, LV 58SER01A 1 set is installed EX, LV 58SER01A 1 set is installed
EX, LV 58SER01A 1 set is installed EX, LV 58SER01A 1 set is installed EX, LV 58SER02 1, LV 58SER 01A
1 set is installed
EX, LV 58SER02 1, LV 58SER 01A 1 set is installed
EX, LV 58SER03 1 set is installed
OptionEX, LV 58SER04 1 set is installed EX, LV 58SER40A 1 set is installed EX, LV 58SER40A 1 set is installed
Multi
Wave form Vector
4 input Picture Waveform
Status Phase
V-ANC 5 Bar EyePattern/Jitter COMPOSITE
CinezoneMPEG Audio
Option
Cinelite
Page 14
14
LV 5800 Platform Options
This unit is an SDI input unit that installed in a LV 5800 input slot. The unit allows waveform display, pic­ture display, and error detection of the SDI signal on the LV 5800. Combination with other optional units allows various displays such as the eye pattern display of the SDI signal (LV 58SER02) and the Lissajous and level displays of the embedded audio (LV 58SER40A). The SDI signal that is inputted to the ACH or the BCH can be out­putted respectively from the ACH/BCH Reclockout output con­nector by interlocking with the input key of the front panel.
Video Formats and Corresponding Standards
Single Link System Video Signal Corresponding Formats and Corresponding Standards
Dual Link System Video Signal Corresponding Formats and Corresponding Standards
Ancillary data standard Embedded audio standard Format Setting
Input/Output Connector
SDI Input
Input Connector
Input Impedance Input Return Loss Maximum Input Voltage
External Sync Signal Input
Input Signal Input Connector
SDI Output
Output Connector
Output Impedance Output Voltage Output Return Loss
Waveform Display Function
Waveform Operation
Display Mode
Overlay display Parade display
Gain Adjustment Blanking Period YCBC
R
GBR conversion
Pseudo-Composite Display
Timing Display
Channel Assignment
Line Select Image Quality Adjustment
Vertical axis
Sensitivity
Gain Variable Gain Amplitude Accuracy Frequency Response HDTV
Y Signal
C
B, CR Signal
Low-pass Attenuation Frequency Response SDTV
Y Signal
C
B, CR Signal
Low-pass Attenuation
Horizontal Axis
Line Display
Display Format
SMPTE 291M HD-SDI: SMPTE 299M SD-SDI: SMPTE 272M Automatic setting
BNC connector 2 connectors For single link A ch / B ch 2 systems For dual link link A / link B 1 system 75 15 dB or more 5 MHz to serial clock frequency ±2 V (DC + peak AC )
Tri-level sync or NTSC/PAL black burst BNC connector 1 system 2 connectors
BNC connector 2 connectors Reclocks serially and outputs the input signal. For single link A ch / B ch 2 systems For dual link link A / link B 1 system 75 800 mVp-p ±10 % 15 dB or more 5 MHz to serial clock frequency
Displays component signals overlaid Displays component signals side by side x1 / x5 / variable Show / hide selectable Converts YCBCRsignals into GBR and displays the result. Digitally converts component signals into compos­ite signals and displays the result. Displays by calculating Y-C
B and Y-CR
Uses bowtie signals (authorised by Tektronix, inc.) Selects GBR order or RGB order for the GBR con­version display Displays the selected line Brightness adjustment
V scale 0 V to 0.7 V, -0.3 V to 0.7 V % scale 0 % to 100 %, -50 % to 100 % x1, x5, and variable x0.2 to x10 ±0.5 %
±0.5 % 1 MHz to 30 MHz ±0.5 % 0.5 MHz to 15 MHz 20 dB or more at 20 MHz
±0.5 % 1 MHz to 5.75 MHz ±0.5 % 0.5 MHz to 2.75 MHz 20 dB or more at 3.8 MHz
Overlay: 1H, 2H Parade: 1H, 2H, 3H Timing: Y-C
B,Y-CR
4Y Parade*1: 4H
FEATURES
Two-Channel Serial Digital I/O
An SDI input unit contains two channels of SDI input connec­tors. The two connectors can also function as a dual link input of a single channel. SDI output that is reclocked using a serial signal is provided for each input. In addition, the SDI signal that is inputted to the ACH or the BCH can be outputted respectively from the ACH/BCH Reclockout output connector by interlocking with the input key of the front panel.
Video Signal Display Function
In addition to displaying the video waveforms, vectors, and pic­tures of the SDI signal on a full screen, 2- and 4-screen multi display can be shown. The multi display allows arbitrary combi­nation of a single or multiple input signals to be displayed. (Multi display in which link A and link B are separated during dual link operation is not allowed.)
Error Detection Function
Detects various errors related to the SDI, embedded audio, and ancillary data including CRC errors and EDH errors.
Ancillary Data Analysis
Supports various types of ancillary data for analysis display. In particular.
5 BAR DISPLAY
Peak levels of video signals can be displayed in place of the vectors.
SDI-EXT REF Phase Difference Display Function
The SDI-EXT REF phase difference display function shows the phase difference between the SDI signal and the external sync signal (EXT REF).
Simultaneous Monitoring of Component and Composite Gamut Using the 5 Bar Displays
Japanese Caption Display Function (to be supported in the future)
Embedded Audio Demultiplex Function
The unit is equipped with a function for demultiplexing the embedded audio signal. Level meter and Lissajous displays can be achieved when used in combination with the digital audio unit (LV 58SER40A). The signal can also be output as AES/EBU.
Dual link input
OPTION
FS 3033 Cinelite II (Cinelite and Cinezone)
Format
Y, CB,C
R
4:2:2
Quantization
10bit
Scanning 1080i
1080p
1080PsF
720p
525 625
Standard Supported
SMPTE 274M SMPTE 292M
SMPTE
RP211
SMPTE 292M SMPTE 296M
SMPTE 292M
SMPTE 259M
Frame(Field) Frequency
60/59.94/50 30/29.97/25/ 24/23.98 30/29.97/25/ 24/23.98 60/59.94/50/ 30/29.97/25/ 24/23.98
59.94 50
Scanning
1080p
1080PsF
1080i 1080p
1080PsF
1080i 1080p 1080p
1080PsF
1080i
Quantization
10 bit
12 bit
10 bit
12 bit
Format
GBR 4:4:4
Y, CB,CR 4:2:2
Frame(Field) Frequency
30/29.97/25/ 24/23.98 30/29.97/25/ 24/23.98 60/59.94/50 30/29.97/25/ 24/23.98 30/29.97/25/ 24/23.98 60/59.94/50 60/59.94/50 30/29.97/25/ 24/23.98 30/29.97/25/ 24/23.98 60/59.94/50
Standard Supported
SMPTE 372M (1920x1080)
LV 58SER01A SDI INPUT SPECIFICATIONS
option
Cinelite Cinezone
LV 58SER01A SDI INPUT
Plug-In Unit for LV 5800
Page 15
15
Magnification
Field Display
Display Format
Time Base Accuracy
Cursor Measurement
Configuration
Amplitude Measurement Time Measurement Frequency Display
Vectorscope Display
Scale Gain Variable gain Amplitude Accuracy IQ Axis Pseudo-Composite Display
Image Quality Adjustment
Phase Difference Display
Display
Display Range
Sync Signal Phase Difference Measurement of Dual Link(future support)
Picture Display
HDTV Display SDTV Display Marker Display
Gamut Error Display Line Select Image Quality Adjustment
Status Display
Status Display of SDI Signal
Signal Detection Format Equivalent Cable Length Measurement
Embedded Audio Channel
Error Detection of SDI signals
CRC Error EDH Error TRS Error Line Number Error
Illegal Code Error
Embedded Prohibition Error
Cable Length Meter Error
Error Detection of Embedded Audio
BCH Error
DBN Error Parity Error
Error Detection of Ancillary Data
Checksum Error Parity Error
Image Evaluation
Gamut Error
Composite Gamut Error
Level Error
Freeze Detection Black Detection
Event Log
Number of Logs
5 Bar Display
Bar Display
Analysis Function
Data Dump Display
Display Format
Line Select Sample Select Jump Function Data Output
Audio Control Packets
Display Content Group Selection
EDH Display
Standard Supported Display Content
Format ID Display
Standard Supported Display Content
Closed Caption Data Display
Standard Supported
Display Content Inter-Stationary Control Data (NET-Q) Display
Standard Supported
Display Content
Log Function V-ANC User Data Display
Standard Supported Arbitrary ANC Packet Display
Method of Specifying ANC Time Code Display
Corresponding Time Code
Display Method
Embedded Audio Processing
Clock Generation System
Closed Caption Processing (future support)
SMPTE System
Cable Length Measurement
Detection method
Supported Cables
Display Range
Accuracy Resolution
Frame Capture Function
Media Internal Memory Capacity
Data Output
Recalling Capture Data
Waveform Comparison
Power Consumption
Weight Accessory
Selects x1, x10, x20, ACTIVE, or BLANK *1 As for 4Y parade mode, two LV 58SER01A (SDI
INPUT unit) should be inserted, and four inputs need to synchronize in the same format each other together.
Overlay: 1V, 2V
(2V display not allowed for progressive) Parade: 1V, 2V, 3V Magnification: x1, x20, x40 ±0.5 %
Horizontal cursors: 2 cursors (REF and DELTA) Vertical cursors: 2 cursors (REF and DELTA) Measured in [%] and [V] Displayed in [usec] or [msec] Displays the frequency in which the time between cursors is considered a cycle.
Selects 75 % or 100 % (Using a color bar) Selects x1, x5, IQ-MAG or variable x0.2 to x10 ±0.5 % Selects show or hide Digitally converts component signals into compos­ite signals and displays the result. (the color matrix for HDTV signal is converted into SDTV) Brightness adjustment
Displays the phase difference between the SDI signal and external sync signal numerically and graphically Holds and displays eight phase difference values being measured V direction ±1/2 Frame H direction ±1 Line *The phase difference display in the H direction may fluctuate in the range of ±1 clock when the signal is switched. HD tri-level sync or black burst
Displays phase difference between Link A and B with the number of the parallel reclock. (including ±1 clock error)
Displayed by sampling the pixels (8 bit RGB) Displayed by interpolating pixels (8 bit RGB) Center marker 4:3 or 16:9 marker display Safe action marker display Safe title marker display On picture indication of gamut errors Displays the selected line as a marker GBR gain adjustment, Contrast adjustment, Brightness adjustment
Detects the presence or absence of SDI signals. Auto format Detection
Converts the SDI signal attenuation into a coaxial cable length and displays the result. Displays the embedded audio channel number.
Detects transmission error of HD-SDI signals. Detects transmission error of SD-SDI signals. Detects errors in the TRS position and protection bit. Line number errors in the HD-SDI signals are being detected. Detects data in the range of 000h to 003h and 3FCh to 3FFh outside the TRS or ADF header. Detects the presence or absence of embedded audio at the embedded prohibition line. Detects the signal attenuation and displays the result.
Detects transmission errors of embedded audio packets in the HD-SDI signal. Detects sequential errors in audio packets. Detects parity errors in audio packets embedded in HD-SDI dignals
Detects transmission errors in the ancillary data. Detects parity errors in the ancillary data header.
Detects Gamut Errors by specifying duration and size. Upper limit: 90.8 % to 109.4 % (0.1 % steps) Lower limit: -7.2 % to +6.1 % (0.1 % steps) Monitors the level error when the component sig­nal is converted into composite signal Upper limit: 90.0 % to 135.0 % (0.1 % steps) Lower limit: -40.0 % to 20.0 % (0.1 % steps) Detects Y C
B CR level errors
Y upper limit: -51 mV to 766 mV (1-mV resolution) Y lower limit: -51 mV to 766 mV (1-mV resolution) CBCRupper limit: -400 mV to 399 mV (1-mV resolution) C
BCR
lower limit: -400 mV to 399 mV (1-mV resolution) Detects video freeze Detects blackouts of the video signal
Error items, time stamps, etc.
Displays the Y GBR component Gamut and com­posite Gamut
Displayed by serial data sequence or channel separation. Displays the selected line Displays the selected sample Move to EAV or SAV by one-key operation Save data in text format to a PC via or Ethernet or USB memory.
Analyzes and displays the audio control packets One group is selected from four groups.
SMPTE RP-165 Analyzes and displays the EDH packets. Displays the received CRC errors.
SMPTE 352M ARIB STD-B39 Analyzes and displays the Format ID.
ARIB STD-B37,EIA/CEA-608,EIA-708 Analyzes and displays the closed caption data.
ARIB STD-B39 Analyzes and displays the Inter-Stationary Control Data. Logs Q signals
ARIB TR-B23
Selects DID or SDID
Selects LTC or VITC SMPTE RP-188 Switches the display of internal clock, and the time code.
SD-SDI: Generated from the video clock HD-SDI: Generated from the video clock Dual link (future support): Generated from the video clock
The closed caption data that is multiplexed in the SDI signal can be overlaid on the picture display. CEA/EIA-608-B embedded in the CDP packets as defined in CEA/EIA-708-B. CEA/EIA-608-B VBI(CEA/EIA-608-B Line21)
Converts the SDI signal attenuation into a coaxial cable length and displays the result. HD-SDI: Selects L-7CHD, LS-5CFB, or 1694A SD-SDI: Selects LS-5C2V, 8281, or 1505A HD-SDI: From under 5 m to 130 m or more (For L-7CHD: From under 10 m to 200 m or more) *
Less than 10 m to greater than or equal to 200 m for L-7CHD SD-SD: From under 50 m to 300 m or more ±20 m 5 m (For L-7CHD: 10 m)
Internal memory (RAM) or USB memory Video data 1 Frame 2 Systems For Dual Link mode: 1 Frame 1 system Save capture data to a PC via Ethernet network
or a USB memory. Recalls and displays the Picture/ Waveform/ Vector of 1 frame capture data. The capture data saved in the USB memory can be read back. (
Reading back operation is possible only if an SDI input
of the same format as the captured data is available
) Simultaneous display of captured data and real data.
Supplied from LV 5800 70 Wmax. (If one unit is installed to the LV 5800) 18 Wmax. (additional power consumption for each additional unit installed to the LV 5800)
0.28 kg, 0.6 lbs
Instruction manual ................................................1
Precautions Concerning Dual Link Operation
Aliasing occurs in the V sweep display of 1080p/60, 59.94, and 50, because the unit processes the sampling data. The picture display is processed using 8 bits even if the quantization is set to 12 bits. In addition, waveform display in external synchronization mode is not allowed if 1080p/60 (59.94) or 1080p/50 signal is applied.
Page 16
16
LV 5800 Platform Options
LV 58SER02 EYE PATTERN UNIT
Plug-In Unit for LV 5800
LV 58SER03 COMPOSITE VIDEO INPUT UNIT
Plug-In Unit for LV 5800
This unit displays eye patterns. It is installed in a LV 5800 input slot. By combining with the LV 5800 input unit, eye pattern waveforms of SDI signals can be monitored. Automatic measurement of para­meters such as amplitude, rise time, and fall time is also possible.
FEATURES
HD-SDI, SD-SDI Format Support
6 Systems of Eye Pattern Displays and Jitter Measurement
Displays the SDI signal eye pattern or measures the jitter of one system among up to 6 systems by combining 3 SDI input units and selecting A or B among the three modules. (Two Eye units cannot be installed simultaneously.)
Eye Pattern Display
Displays the eye pattern of the timing jitter or alignment jitter by switching the filter.
Jitter Measurement
The jitter measurement by the phase detection method allows accurate jitter measurement even if the eye is barely open. In addition, timing jitter and alignment jitter can be measured.
Automatic Measurement
The eye pattern display allows automatic measurement of the eye pattern amplitude, rise time, and fall time. The jitter display allows automatic measurement of the timing jitter and alignment jitter values.
Jitter Display Using Video Sweep
Allows V sweep and H sweep displays.
Simultaneous Display on the Multi Display
The multi display allows the eye pattern waveform and jitter waveform to be displayed simultaneously. In addition, the eye pattern display screen automatically measures the eye pattern amplitude, rise time, and fall time, while the jitter dis­play screen automatically measures the timing jitter and alignment jitter.
Alarm Monitoring
The alarm monitor mode allows the eye pattern amplitude, rise time, and fall time to be monitored with respect to the threshold level specified in advance. It also monitors the tim­ing jitter and alignment jitter using the phase detection method. An alarm is displayed when the threshold level is exceeded. The alarm can also be logged.
Supported Formats
Data Rate
HD-SDI SD-SDI
Eye Pattern
Method Amplitude Accuracy Time Axis Time Axis Accuracy Jitter Filter
Jitter Detection
Method Time Axis Time Axis Accuracy Jitter Filter
Power Consumption
Weight Accessories
LV 58SER02 EYE PATTERN UNIT SPECIFICATIONS
SMPTE292M 1.485 Gbps, or 1.485/1.001 Gbps SMPTE259M 270 Mbps
Equivalent time sampling method 800 mV ±5 % for 800 mV input 2 / 4 / 16 Eye pattern Display ±3 % 10 Hz HPF 100 Hz HPF 1 kHz HPF 100 kHz HPF
Phase detection method H rate or V rate ±3 % 10 Hz HPF 100 Hz HPF 1 kHz HPF 100 kHz HPF (* Doesn't support JITTER measurement of a DVB­ASI standard Eye pattern only.)
Supplied from LV 5800 20 Wmax.
0.4 kg, 0.9 lbs
Coaxial cable .........................................................1
Instruction manual..................................................1
The LV 58SER03 provides the LV 5800 with two composite (NTSC/ PAL) inputs. The LV 5800's newest functions related to waveforms such as the waveform monitor, vectorscope, and simple picture monitor can be used on analog video signals of NTSC and PAL formats. For a description of the specifica­tions other than those of this newly added option, see the specifications of the standard model. This unit in combination with the LV 58SER01A is suitable for moni­toring in a mixed environment containing SDI and composite signals.
FEATURES
Input/Output
There are two input connectors: INPUT A and INPUT B. The selected channel is output from the PIX OUT connector on the rear panel.
Display
Waveform display, vectorscope display, picture display, and EXT REF phase display function are available. In addition, the luminance component can be displayed using a low-pass filter.
SCH Measurement Function
You can perform SCH measurements which are essential when editing the composite signal.
EXT REF Phase Display Function
Compares the input signal to the V.H sync signal of the external reference signal and displays the phase difference numerically and graphically. This function makes synchronization phase management easy.
Miscellaneous
Cursors can be used to measure the amplitude and time, with high accuracy.
Page 17

17

LV 58SER04 MPEG DECODER

Plug-In Unit for LV 5800
Measured Signal Supported Standards
Input
Composite Video Input Connector Input Impedance Input Return Loss Maximum Input Voltage
Output
Composite Video
Output Signal Output Connector Output Impedance Output Amplitude Frequency Characteristics
Display
WAVE Display VECTOR Display PICTURE Display
Waveform Display Section
Vertical Axis
Sensitivity
Gain Variable Gain Amplitude Accuracy Frequency Characteristics
Composite Signal
Step Response (for 1 V full scale, flat, 2T pulse, and 2T bar)
Overshoot Preshoot Ringing Pulse/Bar Ratio
Vertical Tilt Filter DC Restorer
LV 58SER03 COMPOSITE VIDEO INPUT UNIT SPECIFICATIONS
Composite video signal (NTSC/PAL) SMPTE 170M and ITU-R BT.470
Select A or B BNC connector 75 30 dB (up to 6 MHz) ±5 V (DC + Peak AC)
Active BNC connector 1 system 1 connector 75 1 Vp-p ± 5 % ±5 % 25 Hz to 5 MHz +5 % to -10 % 5 MHz to 5.6 MHz
Waveform display Vectorscope display Picture display
V Scale (PAL) -0.3 V to 0.7 V IRE Scale (NTSC) -40 IRE to 100 IRE Select x1 or x5 0.2 to 2 ±1 %
±2 % 25 Hz to 5 MHz +3 % to -7 % 5 MHz to 5.6 MHz
±2 % ±1 % ±2 % ±1 % ±1 % Luminance filter Clamp to the back porch (fixed)
Horizontal Axis
Operation Mode Display Format
Line Display Line Magnification Field Display Field Magnification
Time Base Accuracy
Vectorscope Display Section
Sensitivity Gain Variable Gain Phase Accuracy Amplitude Accuracy Phase Adjustment Range Setup (NTSC) NTSC Display (PAL) IQ Axis SCH
Status Display Section
Display
Display Range
V direction H direction
Synchronization Signal
General Specifications
Environmental Conditions
Power Consumption Weight Accessories Picture Display Line Selector Cursor Measurement
Amplitude Measurement Screen Capture
Overlay Displays only a single waveform
1H or 2H Select x1, x10 or x20 1V or 2V Select x1, x20 or x40 ±1 %
Select 75 % or 100 % Using a color bar Select x1, x5, or IQ-MAG
0.2 to 2 ±2 ˚ ±3 % 360˚ Select 0 % or 7.5 % Select NTSC or PAL display Select show or hide Displays the SCH value numerically
Displays the phase difference between the com­posite signal and external sync signal numerically and graphically. Holds and displays eight phase difference values being measured.
±1/2 frame ±1/2 Line NTSC/PAL black burst signals
Conforms to the LV 5800 Supplied from the LV 5800 9 Wmax.
0.25 kg, 0.5 lbs
Instruction manual .................................................1
(Conforms to the LV 5800) (Conforms to the LV 5800) (Conforms to the LV 5800)
Measure in terms of [IRE] or [V] (Conforms to the LV 5800)
The LV 58SER04 is an input unit that receives MPEG-2 TS (DVB­ASI) signals and displays video/audio information on the LEADER LV 5800 (Multi Monitor). Because it contains an MPEG-2 video decoder and audio decoder, it can display the signal using the video signal waveform display, vectorscope display, pic­ture display, and audio display. The LV 58SER04A can also be used to monitor errors defined by ETSI ETR-290, to display PAT and PMT data, and to display the TS bit rate and the bit rate for each PID. These features are ideal for continuous monitoring of MPEG-2 TS signals in broadcasting sta­tions and similar facilities. In addition, the LV 58SER04 can do the following when combined with other units.
*1 Cannot descramble broadcast scrambling. May not be able to decode all
MPEG-2 data formats. *2 Dolby is a trademark of Dolby Laboratories. *3 When decoding Dolby Digital(AC-3), Dolby E option is necessary for the LV
58SER40A(DIGITAL AUDIO)separately. *4 There are some limitations on the error detection feature. *5 Jitter cannot be displayed even if the LV 58SER02 is used.
• Eye pattern display of DVB-ASI signals (when combined with the LV 58SER02).
• Lissajous and level displays of audio signals (when com­bined with the LV 58SER40A).
FEATURES
DVB-ASI Input Connector
The unit comes with one DVB-ASI input connector.
Video Decoding
Decodes compressed video data on the MPEG-2 TS (MPEG-2 Video 4:2:2, 4:2:0) and displays a video signal waveform, vectorscope, or picture.
*1
Audio Decoding
Combine with the LV 58SER40A (DIGITAL AUDIO) to decode audio data on the MPEG-2 TS and show Lissajous, sound image, and level meter displays as well as outputs digital audio signals. The decodable audio data types are MPEG-2 AAC, Dolby
*2
Digital (AC-3)*3, and LPCM (SMPTE 302M)
PID Search
Video and audio search for PID automatically.
Error Detection
Monitors and displays ETSI ETR 290 priority 1 and 2 errors.
*4
Status Display
Displays packet bit rates and measures PCR jitter. Displays PAT, PMT, and a selected packet dump.
Eye Pattern Display
Combine with the LV 58SER02 (EYE PATTERN unit) to dis­play DVB-ASI eye patterns.
*5
Standards
Supported Standards Profile and Level
DVB-ASI I/O
Input Connector
Input Connector Number of Input Connectors Maximum Input Voltage
Input Signal
Serial Clock Transmission Mode Maximum Bit Rate Supported Packet Sizes Packet Size Detection
LV 58SER04 MPEG DECODER SPECIFICATIONS
ISO/IEC 13818-1 MP@HL, MP@ML, 422@ML, 422P@HL
BNC-R 1 connector, 75 ±2 V (DC + peak AC)
270 MHz Packet/Burst 66 Mbps 188, 204, and 208 bytes Audio Detects supported packet sizes
Page 18
18
LV 5800 Platform Options
Decoding Function
Video Formats:
Audio Signals
Video Signal Waveform Display Function
Waveform Operation
Display Mode
Y, CB, CRto G, B, R Conversion
Pseudo-Composite Display
Channel Assignment
Line Select Image Quality Adjustment
Vertical Axis
Sensitivity
V Scale % Scale Gain Variable Gain Amplitude Accuracy
HDTV Frequency Characteristics
Y Signal C
B,CR signal
Low-pass Attenuation
SDTV Frequency Characteristics
Y Signal C
B,CR signal
Low-pass Attenuation
Horizontal Axis
Line Display
Display Mode
Magnification
Field Display
Display Mode
Magnification Time Accuracy
Cursor Measurement
Composition
Horizontal Cursors
Vertical Cursors Amplitude Measurement Time Measurement Frequency Measurement
1920x1080i / 59.94, 60, 50 (4:2:0,4:2:2) 1440x1080i / 59.99, 60, 50 (4:2:0,4:2:2) 1280x720p / 59.94, 60, 50 (4:2:0,4:2:2) 720x480i / 59.94 (4:2:0,4:2:2) 720x576i / 50 (4:2:0,4:2:2) MPEG-2 AAC, Dolby Digital(AC-3), MPERG-1 LAYER-2
LPCM(SMPTE 302M) (LV 58SER40A (DIGITAL AUDIO) is necessary sep­arately. In addition, when decoding Dolby Digital (AC-3), Dolby E option is necessary) *
This unit decodes only one set of video data and audio data. Even if you use the LV 5800 multi display, the unit cannot decode different video and audio streams simultaneously. If you assign the display showing the data that this unit is decoding to multiple displays and you change the PID of the data being decoded, the PIDs on all displays change simultaneously.
Overlay display
(displays component signals overlaid)
Parade display
(displays component signals side by side) Converts Y, CB, CR signals into G, B, R and displays the result Displays component signals artificially as compos­ite signals G, B, R or R, G, B order (when displaying G, B, R converted signals) Displays the selected line Adjusts the brightness
0 to 0.7 V, -0.3 to 0.7 V 0 to 100 %, -50 to 100 % x1, x5, variable x0.2 to x2 ±0.5 %
±0.5 % (1 to 30 MHz) ±0.5 % (0.5 to 15 MHz) 20 dB or more (at 20 MHz)
±0.5 % (1 to 5.75 MHz) ±0.5 % (0.5 to 2.75 MHz) 20 dB or more (at 3.8 MHz)
Overlay: 1H, 2H *
1
Parade: 1H, 2H, 3H x1, x10, x20, ACTIVE, BLANK
Overlay: 1V, 2V *
1
Parade: 1V, 2V, 3V x1, x20, x40 ±0.5 %
2 cursors (REF and DELTA) 2 cursors (REF and DELTA) Percentage and voltage displays Displays time in seconds Displays the frequency by considering the time between cursors to be a cycle *1 The 2V display is not allowed if the input signal
is progressive.
Vectorscope Display
Scale Gain Variable Gain Amplitude Accuracy IQ Axis Pseudo-Composite Display
Image Quality Adjustment
Picture Display
HDTV Display SDTV Display Marker Display
Line Select Display Size Image Quality Adjustment
Section and PCR Information
PAT
PAT Detection
Cycle Measurement
*2
PAT data display
PMT
PMT Detection Cycle Measurement
*2
PMT data display
NIT
NIT Detection
Cycle Measurement
*2
CAT
CAT Detection Cycle Measurement
*2
PCR
PCR detection
Cycle Measurement
*2
PCR jitter
Dump Display
Function
Notation
Bit Rate Display
Function
Bar Display
Displayed Sections Displayed Packets
General Specifications
Environmental Conditions Power Supply
Weight Accessory
75 %, 100 % (for the color bars) x1, x5, IQ-MAG, variable x0.2 to x2 ±0.5 % Show or hide Displays component signals by converting to com­posite signals that have burst added artificially. (The color matrix for HDTV signals is converted to SDTV.) Adjusts the brightness
Displayed by sampling pixels Displayed by interpolating pixels Center marker display 4:3 or 16:9 marker display Safe action marker display Safe title marker display Marks the selected line Optimized display, actual size display GBR level adjustment, contrast adjustment, bright­ness adjustment
Automatically recognizes packets whose PID is 0000h as PAT Measures the PAT cycle in 1-ms intervals PAT dump display
Select the PID of the PMT to be decoded Measures the PMT cycle in 1-ms intervals PMT dump display
Automatically detects packets with the NIT PID specified by the PAT. Measures the NIT cycle in 1-ms intervals
Recognizes packets whose PID is 0001h as CAT Measures the CAT cycle in 1-ms intervals
Automatically detects packets with the PCR PID specified by the selected PMT Measures the PCR cycle in 1-ms intervals Measures the PCR accuracy based on the internal reference clock
*2: If a section is divided into multiple TS packets,
the cycle is measured for each section.
Dump display of the PAT, PMT, and the dump dis­play of the selected packet Displays binary and hexadecimal values and contents
Displays the bit rate and cycle of the main sections and packets Displays the occupied bandwidth with respect to the TS bit rate using bars NIT, CAT, PAT, and PMT Video, audio, PCR, and null
Conforms to the LV 5800 Supplied from the LV 5800 70 W max. (if one unit is installed to the LV 5800) 20 W max. (additional power consumption for each additional unit installed to the LV 5800)
0.4 kg, 0.9 lbs
Instruction manual..................................................1
LV 58SER20 DVI-I OUTPUT UNIT
Plug-In Unit for LV 5800
This unit is a DVI-I OUTPUT unit that outputs the contents dis­played on the front LCD panel from the DVI-I connector to an external monitor. The unit is installed in a LV 5800 output slot.
FEATURES
DVI-I Connector
The connector allows the screen displayed on the LV 5800 to be shown on an external monitor. The DVI output provides both digital and analog output allowing the signal to be used on a wide variety of XGA-com­patible monitors.
DVI-I Connector
Signal Format
Display Format DDC Function HOT PLUG Detection Function Output Connector
Power Consumption
Weight Accessory
LV 58SER20 DVI-I OUTPUT UNIT SPECIFICATIONS
Single Link T.M.D.S Analog RGB XGA (Effective area 1024x768 dots) Not supported Not supported DVI-I 1 system
Supplied from LV 5800 5 Wmax.
0.2 kg, 0.4 lbs
Instruction manual..................................................1
Page 19

19

LV 58SER40A DIGITAL AUDIO

Plug-In Unit for LV 5800
The LV 58SER40(A) (DIGITAL AUDIO) operates as an AES/EBU I/O unit when installed in a LV 5800 input slot or as an AES/EBU output unit when installed in a LV 5800 output slot. It allows the LV 5800 to display Lissajous, sound image, level meter, and signal status displays*
1
for data in 8 AES/EBU channel pairs (16 chan­nels)*
2
and 2 analog audio chan-
nels.*
3
If the LV 58SER01A (SDI INPUT) is installed in the LV 5800, this unit can process AES/EBU signals that are embedded in SDI signals. If the LV 58SER04 (MPEG DECODER) is installed, this unit can process MPEG-1 Layer 2, MPEG-2 AAC, AC3 and LPCM that are embedded in DVB-ASI signals.
FEATURES
8 AES/EBU I/O Pairs (16 Channels)
This unit operates as an AES/EBU I/O unit when installed in a LV 5800 input slot or as an AES/EBU output unit when installed in a LV 5800 output slot.
Headphone Output
When you install this unit into an LV 5800 input slot, you can listen to the selected channel audio using a headphone.
Various Display Features
This unit enables the LV 5800 to display the following items on the AES/EBU input signals.
•Single Lissajous display between any two channels
•Multi Lissajous display that simultaneously shows 4 or 8 sin­gle Lissajous displays of different channel pair combina­tions.
•Sound image display
•Meter display
The unit also enables the LV 5800 to display the following AES/EBU signal status bits.
• Channel status bit
• User bit
• Validity bit
• Parity bit
* You cannot assign the audio measurement display to multiple areas
.
Analog Audio Input
The LV 58SER40A can measure analog audio signals on 2 channels.
Dolby Decoding Capability (Optional)
* Dolby E, Dolby Digital is a trademark of Dolby Laboratories.
Input and Output Signals
Supported Formats Sampling Frequency
Rear BNC Connectors
Maximum Input Voltage Output Voltage I/O Connectors
Input/Output Impedance Input and Output Switching
Analog Audio Input
Maximum Input Voltage Input Connector
Input Impedance
Waveform Displays
Lissajous Display
Sound Image Display
Channel Mapping Surround Formats
Correlation Meter
Meter Display
During Multi Lissajous Display
During Single Lissajous Display
Response Mode Selection
*1
LV 58SER40A LV 58SER40
Peak Hold Mode Selection
*1
LV 58SER40A
LV 58SER40 Peak Hold Time Display dynamic range
*2
Reference Level Setting Warning Level Setting Over Level Setup
Status Display
Channel Status Bit Display
User Data Bit Display
Dolby E Metadata Display
Dolby Digital Metadata Display
Error Detection
Level Over Detection
Detection Setting
Clip Detection
Detection Setting
Mute Detection
Detection Setting
Parity Error Detection
Validity Error Detection
CRC Error Detection
Code Violation Detection
Headphone Output
Output Connector
Output Power General Specifications
Environmental Conditions Power Consumption
Weight Accessories
LV 58SER40A DIGITAl AUDIO SPECIFICATIONS
IEC60958, Dolby E* (option), Dolby Digital* (option) 48 kHz
± 5V (DC + ACpeak)
1.0 Vp-p ± 10 % (into 75 ) BNC connectors (eight channels in four-channel pairs) 75 Whether to use the connectors as audio signal input connectors or as output connectors for audio signals that are embedded in SDI or DVB-ASI sig­nals is selectable on the LV 5800.
+18 dBm (6.2 Vrms) D-Sub 25-pin connector on the LV 5800 (DC-cou­pled balanced input) At least 5 k * The LV 58SER40 does not support analog audio input.
Single Lissajous display between any two channels Multi Lissajous display that simultaneously shows 4 or 8 single Lissajous displays of different channel pair combinations.
L, R, C, LFE, Ls(S), Rs, LL, RR 3-1, 3-2, 3-2-2
Displays the correlation between 2 channels in the range of -1 to 1
Displays the levels of 8 channels or 16 channels on a bar graph Displays the levels of 2 selected channels on a bar graph
TRUE PEAK, PPM type I, PPM type II, VU TRUE PEAK, PPM, VU (when the meter response mode is VU) TRUE PEAK, PPM type I, PPM type II TRUE PEAK, PPM
0.5 to 5.0 s (in 0.5-s steps), HOLD
-60 dBFS, -90 dBFS
-40.0 to 0.0 dBFS
-40.0 to 0.0 dBFS
-40.0 to 0.0 dBFS *1 The LV 58SER40 PPM (Peak Program Meter) and
the LV 58SER40A PPM type I are equivalent.
*2 Fixed at -60 dBFS when measuring an analog
audio signal.
Dump display, text display Dump display Text display Text display Counts the number of errors for each channel Counts the number of times the input signal level exceeds the specified level
-40.0 to 0.0 dBFS Detects an error when the number of maximum sig­nal values that are received consecutively exceeds the specified number of samples and counts the number of times this error occurs 1 to 100 samples Detects an error when the length of a received mute signal exceeds the specified duration, and counts the number of times this error occurs 1 to 5000 ms Counts the number of times the input signal parity bit differs from the parity bit value that the LV 58SER40(A) calculates Counts the number of times the input signal validity bit is 1 Counts the number of times the input signal CRC value differs from the CRC value that the LV 58SER40(A) calculates Counts the number of times the input signal bi­phase modulation status is in error
3.5 mm stereo mini jack
121.5 mWrms max. (into 8 )
The same as the LV 5800 9 Wmax. supplied from the LV 5800
0.27 kg, 0.6 lbs
Instruction manual .................................................1
Analog audio cable
(LV 58SER40A only) ..............................................1
*1 All AES/EBU signals must be synchronized. This unit only supports 48 kHz
sampling frequency.
*2 The standard LV 58SER40(A) provides 4 AES/EBU channel pairs (8 chan-
nels). Installing the optional I/O expansion unit expands the I/O connectors to 8 AES/EBU channel pairs (16 channels).
*3 The LV 58SER40 does not support the measurement of analog audio signals.
Page 20
VIDEO
LV 5800/LV 7800 Platform Options
LV 58SER06 3G-SDI INPUT
This 3G-SDI input unit can be in­stalled into an input slot of an LV 5800 (multi monitor) or into an LV 7800 (multi rasterizer). The LV 58SER06 supports 3G-SDI levels A and B, and it can be used to display information such as 3G-SDI signals' video waveforms, vector waveforms, pictures, and error detection results on an LV 5800 or LV 7800. Additionally, by combining the LV 58SER06 with the LV 58SER40A, you can display information such as the Lissajous curves and level meters of embedded audio signals. What's more, the LV 58SER06 can generate 3G-SDI signals and test patterns.
FEATURES
Two Serial Digital Inputs
■
The LV 58SER06 has two switchable 3G-SDI input connectors for monitoring.
Two Serial Digital Outputs
■
The LV 58SER06 can reclock input signals that are received by the input terminal that has been select­ed with the input key (3G-SDI A or 3G-SDI B) and generate these reclocked signals from the 3G-SDI A/B output connector. From the 3G-SDI B output connector, the LV 5800 can transmit a reclocked signal from the 3G-SDI signal that is received through the 3G-SDI B input connector.
Test Pattern Signal Outputs
■
The LV 58SER06 can operate as a 3G-SDI signal pattern generator to generate a 3G-SDI signal from the two output terminals.
Video Signal Display
■
The LV 58SER06 can be used to display 3G-SDI signals' video signal waveforms, vector waveforms, and pictures on not only the 1-screen display, but 2- and 4-screen multi displays.
Error Detection
■
The LV 58SER01A can detect CRC and other 3G­SDI signal errors that are related to embedded audio signals and ancillary data.
Automatic Video Format Setting
■
The LV 58SER06 automatically sets the video for­mat based on payload ID packets.
5 Bar Display
■
You can use the 5 bar display to simultaneously monitor component and composite gamut.
Embedded Audio Extraction
■
By combining the LV 58SER06 with a digital audio unit (the LV 58SER40A), you can perform actions such as displaying level meters and Lissajous curves. You can also generate AES/EBU signals.
SPECIFICATIONS
Video Formats and Corresponding Standards
3G-SDI Video Signal Formats and Corresponding Standards
Color System Quantization
, CR 4:2:2 10 bits 1080p 60, 59.94, 50
Y, C
B
Other Standards Ancillary Data: SMPTE 291M Embedded Audio: SMPTE 299M
Format Setting: Manual and automatic Manual: Manually set the frame frequency Automatic: The LV 58SER06 detects the format informa-
Output Signal
Depending on your selection, the LV 58SER06 generates a reclocked signal (input loop-through) from the input signal or generates a test pat­tern signal, and transmits it from the 3G-SDI A/B output connector and the 3G-SDI B output connector.
3G-SDI A/B Output Connector
When Set to Input Reclock
When Set to Test Pattern
3G-SDI B Output Connector
When Set to Input Reclock
When Set to Test Pattern
Test Pattern Generation Format: Y, C
Corresponding Standard
Pattern: 100 % color bar (100 % white, 100 % satu-
Embedded Audio: Not supported Bit Rate: 2.97 Gbps or 2.97/1.001 Gbps Oscillation Clock: Driven by the internal oscillator
I/O Connectors
3G-SDI Input Connectors Input Connectors: 2 BNC connectors
2 connections (channels A and B)
Input Impedance: 75 Ω Input Return Loss: 15 dB or greater (5 MHz to 1.485 GHz)
10 dB or greater (1.485 to 2.97 GHz)
Maximum Input Voltage
3G-SDI Output Connectors Function: Generation of reclocked signals from the in-
Output Connectors: 2 BNC connectors Output Impedance: 75 Ω Output Return Loss: 15 dB or greater (5 MHz to 1.485 GHz)
10 dB or greater (1.485 to 2.97 GHz)
Output Voltage: 800 mVp-p ± 10 %
Waveform Display
Waveform Operations Display Modes Overlay: Overlays component signals Parade: Displays component signals side by side Blanking Period: Show or hide
Y, CB, CR to GBR Conversion
Pseudo-Composite Display
Channel Assignment: Displayed in GBR or RGB order (when dis-
Line Select: Displays the selected line Display Adjustment: Brightness adjustment and waveform color
(Multi color is only available on the 1-screen
Scanning Frame Frequency
(
Only the audio data of data stream 1 is supported.
tion within the payload ID (SMPTE 325M) and automatically sets the format.
: Generates a reclocked signal from the signal
received through the selected input channel.
: Generates a test pattern signal
: Generates a reclocked signal from the signal
received through input channel B
: Generates a test pattern signal
: SMPTE424M and SMPTE425M
ration),75 % color bar (100 % white, 75 % saturation),100 % white, 50 % white, black, check eld, equalizer, and PLL
148.5 MHz ± 10 ppm or 148.5/1.001 MHz ± 10 ppm
: ±2 V (DC + AC peak)
put signals and generation of test patterns
: Converts the Y, CB, CR signal to GBR and dis-
plays it
: Displays component signals artificially as
composite signals
playing GBR converted signals)
selection (white, green, or multi color)
display.)
Format
, CR 4:2:2 1080p/60, 59.94, 50
B
Corresponding
Standard
SMPTE 424M SMPTE 425M
)
Page 21
Vertical Axis Sensitivity V Scale: 0 to 0.7 V or –0.3 to 0.7 V % Scale: 0 to 100 % or –50 to 100 % Gain: ×1, ×5, or variable Variable Gain: ×0.2 to ×10 Amplitude Accuracy: ±0.5 % Frequency Response Y Signal: ±0.5 % (1 to 60 MHz)
, CR Signal: ±0.5 % (0.5 to 30 MHz)
C
B
Low-Pass Attenuation
: 20 dB or greater (at 40 MHz)
Horizontal Axis Line Display Display Format: Overlay: 1H, 2H
Parade: 1H, 2H, 3H
Magnication: ×1, ×10, ×20, ACTIVE, or BLANK Field Display Display Format: Overlay: 1V
Parade: 1V, 2V, 3V
Magnication: ×1, ×20, ×40 Time Accuracy: ±0.5 % Cursor Measurement Composition Horizontal Cursors: 2 (REF and DELTA) Vertical Cursors: 2 (REF and DELTA)
Amplitude Measurement
: Percentage and voltage displays
Time Measurement: Second display
Frequency Measurement
: Computes and displays the frequency with
the length of one period set to the time be­tween two cursors
Vectorscope Display
Scale: 75 % or 100 % (color bar) Gain: ×1, ×5, IQ-MAG, or variable Variable Gain: ×0.2 to ×10 Amplitude Accuracy: ±0.5 % IQ Axis: Show or hide
Pseudo-Composite Display
: Converts component signals into composite
signals with articially added burst and dis-
plays the results (The color matrix is converted to SDTV.)
Display Adjustment: Brightness adjustment and waveform color
selection (white or green)
Picture Display
Display Format: Samples pixels and displays them (R, G, and
B each use 8 bits)
Marker Displays: Center marker, 4:3 marker, safe action
marker,and safe title marker
Gamut Error Display: Marks the areas of the picture that exhibit
gamut errors
Line Select: Marks the selected line Display Sizes: Compressed and full frame
Image Quality Adjustment
: G, B, R level; contrast; and brightness adjustment
Status Display
3G-SDI Signal Status Display Signal Detection: Detects the presence of a 3G-SDI signal Format:
Detects from the supported video signal formats
(When the LV 58SER06 is configured to
automatically set the format, the format is detected from the payload ID.)
Embedded Audio Channel
Displays the embedded audio channel number
(Only the audio data of data stream 1 is sup-
ported.)
3G-SDI Signal Error Detection CRC Error: Detects 3G-SDI signal transmission errors TRS Error:
Detects TRS position and protection bit errors
Line Number Error: Detects 3G-SDI signal line number errors Illegal Code Error: Detects data within the range of 000h to
003h and 3FC to 3FF in locations other than the TRS and ADF headers
Ancillary Data Error Detection Checksum Error: Detects ancillary data transmission errors Parity Error: Detects ancillary data header parity errors Image Quality Error Detection Frequency Response: Approx. 1 MHz LPF (IEEE STD 205 response)
and approx. 2.8 MHz LPF (removes transient composite gamut and gamut errors due to overshoot and other anomalies)
Gamut Error: Detects time-specied gamut errors Upper Limit: 90.8 to 109.4 % Lower Limit: –7.2 to 6.1 % Area Specication: 0.1 to 5.0 % Time Specication: 1 to 60 frames
Composite Gamut Error
: Detects level errors that occur when com-
ponent signals are converted to composite signals
Upper Limit: 90.0 to 135.0 % Lower Limit: –40.0 to 20.0 % Area Specication: 0.1 to 5.0 % Time Specication: 1 to 60 frames Embedded Audio Error Detection (Only data stream 1 is supported for 3G-SDI level B.)
BCH Error: Detects transmission errors in the audio
packets that are embedded in 3G-SDI signals
DBN Error: Detects audio packet continuity errors Parity Error: Detects parity errors in the audio packets
that are embedded in 3G-SDI signals
Embedded Position Error
: Detects the presence of audio in lines where
it should not be embedded
Event Log Recorded Events: Errors, changes in the input channel, and
time stamps
5 Bar Display
Bar Display: Displays the Y GBR component and com-
posite gamut
(When you are using line select, only the
component gamut of the selected line is de­tected.)
Error Level Setting Component Gamut: The same as the gamut error Composite Gamut: The same as the composite gamut error Frequency Response: The same as the gamut error
Analysis Features
Data Dump Display Display Format: Displays data separated by serial data se-
quence or by channel
(The 3G-SDI level B data dump can display
data stream 1, data stream 2, and data stream 1 and 2 simultaneously.)
Line Select: Displays the selected line Sample Select: Displays from the selected sample Jump Feature: Moves to EAV or SAV with the press of a
single button
Data Output: Data can be saved as text les to USB mem-
ory or to a PC over an Ethernet
Audio Control Packet Display (Only data stream 1 is supported for 3G-SDI level B.)
Display Details: Displays audio control packet analysis Display Format: Text, hexadecimal, and binary Group Selection: Select one group from four available groups Format ID Display
Corresponding Standard
: SMPTE 352M
Display Details: Displays payload ID packet analysis
ANC Packet Display (Only data stream 1 is supported for 3G-SDI level B.)
ANC Specication Method
: DID/SDID
Display Format: Hexadecimal and binary
Time Code Display (Only data stream 1 is supported for 3G-SDI level B.)
Supported Time Codes
Display Mode:
: LTC and VITC (SMPTE 12M-2)
The instrument's internal clock or the time code
Embedded Audio Processing
Clock Generation: Generated from the video clock Synchronization: All audio channels must be synchronized to
the video clock.
Phases: All phases must be in-sync. Channel Separation: You may select a maximum of 4 groups of 16
channels each.
(Only data stream 1 is supported for 3G-SDI
level B.)
* You need an LV 58SER40A unit to display and generate audio.
Frame Capture Feature
Function: Captures frame data Capture Timing: Manual and automatic (error capture) Display: Displays the captured frame data or superim-
poses the captured frame data over the input
signal
Media: Internal memory (RAM) and USB memory
You can only record one frame of data to the
internal memory.
Data Output:
Screen captures can be saved as .dpx les, .tif
les, or in a le format that the instrument can
load. They can be saved to USB memory or
sent to a PC through an Ethernet connection.
Data Input: Data saved to USB memory can be loaded
and displayed on the instrument.*1
Error Capturing: Automatically captures frame data when an
error occurs
*1 Captured data cannot be displayed unless the instrument is receiving
a 3G-SDI signal that matches the format of the captured signal.
Environmental Conditions
Conforms to those for the LV 5800 or LV 7800
Power Consumption
Supplied by the LV 5800 or LV 7800; 18 W max. (This is the power consumption for a single
LV 58SER06 unit installed in an LV 5800 or LV
7800.)
Weight
0.24 kg
Accessory
Instruction manual .......................................1
Page 22
VIDEO
MULTI RASTERIZER
Simultaneous Multiple Input Viewing and Monitoring
Monitor not included
HD-SDI
SD-SDI
LV 7800
MULTI RASTERIZER
GENERAL
The LV 7800 is a new-concept multi rasterizer that enables you to freely combine all the LV 5800 series input and output units to provide  exible support for a variety of situations.
FEATURES
Slots for Four Units
The LV 7800 is equipped with two input slots and two input/out­put slots, which means you can install a maximum of four units. Each input and output unit operates independently
Exter
nal Sync Signal Input
The LV 7800 can receive tri-level sync signals and NTSC or PAL black
burst signals. You can display video signal waveforms in
phase with an external sync signal.
DVI-I Connector
You can view the various LV 7800 displays on an external XGA (1024 × 768) display by connecting the display to the DVI-I connector Additionally, the vector, picture, and audio displays support dis­plays with aspect ratios of 16:9 (in squeeze mode).
Display Examples
Multi-Screen
4 Input Picture
.
.
Waveform/4YPalade
Squeezemode
Supports aspect ratios of 4:3 and 16:9.
eset Settings
Pr
The LV 7800 can store up to 60 frequently used setting con gura­tions. Y
ou can also directly recall preset settings that have been
assigned to the shortcut button.
Key Lock
The key lock feature is useful in preventing mistaken changes to the settings and in pr
USB Port
By connecting a USB memory device to the front panel USB port, you can take scr
Ether
net Port
By running TELNET or FTP on a PC that is connected to the LV 7800
ough the rear panel Ethernet port, you can control the LV 7800
thr remotely, monitor errors, and transfer  les. (SNMP is also supported.)
Parallel Remote Connector
You can load preset settings, detect errors, switch inputs, and ap­ply analog audio signals* thr *To measure analog audio signals, an LV 58SER40A (DIGITAL AUDIO) unit is necessary.
eventing accidental operations on the LV 7800.
een captures, record data, and save preset settings.
ough the rear panel remote connector.
Waveform/Vector
Status
EX, LV 58SER01A, LV 58SER02 1 sets each are installed
5 Bar/Gamut
EX, LV 58SER01A 1 set is installed
EX, LV 58SER01A 2 set are installed
EyePattern/Jitter
EX, LV 58SER01A 2, LV58SER02 1 sets are installed
EX, LV 58SER01A 2 sets are installed
MPEG
EX, LV 58SER04 1 set is installed
EX, LV 58SER01A 1 set is installed
Audio
EX, LV 58SER40A 1 set is installed
EX, LV 58SER01A 1 set is installed
Composite
EX, LV 58SER03 1 set is installed
Page 23
SPECIFICATIONS
LV 7800
Input/Output Slots
SLOT1, SLOT2: Slots for input units
SLOT3, SLOT4:
Slots for input, output, or input/output units
Combinations of Supported Units
LV 7800 Slots
Unit
LV 58SER01A (SDI INPUT) Yes Yes Yes Yes
LV 58SER02 (EYE PATTERN) Yes* Yes* Yes* Yes*
LV 58SER03
LV 58SER04 (MPEG DECODER) Yes Yes Yes Yes
LV 58SER06 (3G-SDI INPUT) Yes Yes Yes Yes
LV 58SER20 (DVI-I OUTPUT) No No Yes Yes
LV 58SER21 (ANALOG COMPONENT OUTPUT)
LV 58SER40A (DIGITAL AUDIO) Yes* Yes* Yes* Yes*
* Only one of this type of unit can be installed in an LV 7800.
(COMPOSITE INPUT)
Does the Slot Support the Units
SLOT1
SLOT2
(Input)
(Input)
Ye s Ye s Ye s Yes
No No Yes Yes
SLOT3
(Input/Output)
(Input/Output)
SLOT4
DVI-I Output
Output Connector: 1
Signal Format: Single link T.M.D.S
Analog RGB
Display Format:
XGA(The effective resolution is 1024 × 768.) Wide displays are also supported (squeeze mode). * Only if the LCD pan­el has a resolution conversion feature.
DDC: Not supported HOT PLUG: Not supported
Screen Capture
Screen Capture:
Capture the screen to an image le (only one screen capture is stored in internal memory)
Media:
Internal memory (RAM) and USB memory
Data Output: Save screen captures in bitmap format
to USB memory or send them to a PC over an Ethernet connection.
Preset Settings
Number of Presets: 60
Media:
Internal memory (RAM) and USB memory
Recall Method: Front panel, remote connector, or Eth-
ernet command
Copying Saved Settings Loading Saved Settings
: Copy preset settings to USB memory.
: Copy all preset settings from USB
memory to the LV 7800.
External Sync Signal Input
Input Connector: 1 pair of BNC connectors
Input Signal: Tri-level sync or NTSC/PAL black burst
Input Impedance: Passive loopthrough, 15 kΩ Input Return Loss: 30 dB or higher Maximum Input Voltage: ±5 V (DC + peak AC)
* If the video signal waveform is displayed using an external sync signal
as a reference, the waveform phase one clock before or after an SDI signal is inserted or the power is turned on is indenite.
External Control Connectors
USB Port
Compliant Standard
Device:
: 2.0
Only large-memory devices are supported.
Function: Take screen captures, record data,
and save preset settings
Ethernet Port
Compliant Standard
: IEEE802.3 10BASE-T/100BASE-T
Connector: RJ-45 Function: Control the LV 7800 and monitor errors
from a PC and save screen captures and data to a PC
Remote Connector Connector: 25-pin D-sub (female) Signal: LV-TTL level (Low active) Function:
Load preset settings, detect errors, switch inputs, and receive analog audio signals*
* To measure analog audio signals, an LV 58SER40A (DIGITAL AUDIO)
unit is necessary.
Headphone Output*
Output Signal: SDI-embedded audio signal, or an
audio signal that was received from an external source
Output Connector: One 6.3-mm stereo jack Volume Adjustment: Volume knob
* Headphone output is enabled when an LV 58SER40A (DIGITAL AUDIO)
unit is installed.
Environmental Conditions
Operating Temperature
: 0 to 40 °C
Operating Humidity: 85 %RH or less (no condensation)
Operating Environment
: Indoors
Operating Altitude: Up to 2,000 m
Overvoltage Category
: II
Pollution Degree: 2
Power Supply Requirements
90 to 250 VAC, 50-60 Hz, 150 W max.
Dimensions and Weight
482 (W) × 88 (H) × 450 (D) mm (not in-
cluding protrusions), 8.5 kg
Accessories
Instruction manual ........................... 1
Power cord ...................................... 1
Cover/Inlet stopper ..........................1
25-pin D-sub connector...................1
25-pin D-sub connector cover .........1
Rear Panel (LV 58SER01A × 3 and LV 58SER40A × 1)
Optional Units
LV 58SER01A
SDI input
(Factory Option) Each unit is the same as the 5800 series units.
LV 58SER02
Eye pattern unit
LV 58SER03
Composite video input
LV 58SER04
MPEG decoder
LV 58SER06*
3G-SDI INPUT
LV 58SER20
DVI-I output unit
LV 58SER21
Analog component output
LV 58SER40A
Digital audio I/O
* To be supported in the future
Page 24
VIDEO
MULTI SDI RASTERIZER
Low-Cost Multi SDI Rasterizer
GENERAL
FEATURES
The LV 7330 is a highly functional, compact, light-weight SDI raster­izer that boasts exceptional cost performance. When the LV 7330 is connected to an external XGA or WXGA moni­tor, it can display the picture of an HD-SDI or SD-SDI signal in addi­tion to video signal waveforms, vectors, audio data, and data analy­ses of the signal. The LV 7330 also comes standard-equipped with CINELITE II, a convenient tool for analyzing luminance data.
■
SDI I/O
The LV 7330 has two SDI input connectors that can be used for both HD-SDI and SD-SDI input. It also has an SDI output connec­tor that you can use to send a reclocked SDI signal.
■
DVI Output
The various LV 7330 displays are transferred through a DVI-I connector to an XGA (1024 × 768) display. The LV 7330 also uses a squeeze method to support aspect ratios of 16:9 (1366 × 768) and 15:9 (1280 × 768).
■
CINELITE II
The LV 7330 comes standard-equipped with CINELITE II (CINELITE and CINEZONE), which is a video signal luminance in­formation analysis tool. With CINELITE, you can use the cursor to select any 3 points and display their f-Stop numbers, percentage values, and level val­ues. You can choose to analyze a single pixel or a small area by setting the size of the measured area to 1 pixel or to the average value for 9 or 81 pixels. With CINEZONE, you can display the luminance levels in the pic­ture using different colors. This allows you to quickly determine the overall luminance distribution in the picture, and it makes it easy to spot overexposure, underexposure, and different lumi­nance levels in dark areas.
■
Picture Display
The LV 7330 has a wide assortment of SDI signal picture display features including zoom, various safety markers, and brightness, contrast, and chroma adjustment. The LV 7330 also supports CEA/EIA-608 closed captioning and superimposition.
■
Video Signal Waveform Display
The LV 7330 uses fully digital waveform display processing to achieve high precision and quality. From video signal waveform display gain expansion, sweep expansion, and cursor measure­ment to pseudo-composite and RGB displays, the LV 7330 has all of the features that people look for in a waveform monitor. The LV 7330 is equipped with an external sync signal input and it can display video signal waveforms based on a tri-level sync signal or an NTSC or PAL black burst signal.
■
Vector Display
The LV 7330 can display component chrominance signal vectors. The amplitude can be manually zoomed, or set to a  xed magni ­cation value such as  ve. The IQ axes, which are useful for vector observation, can be turned on and off.
■
5 Bar Display
The LV 7330 can display the peak levels of the Y, R, G, B and pseudo-composite signals. This feature is useful for monitoring gamut errors.
■
Audio Display
The LV 7330 can extract the audio signal embedded in an SDI signal and display level meters, Lissajous curves, and surround­sound images for up to eight channels. The LV 7330 also supports external digital audio input, for which it can display a two-channel level meter and Lissajous curves. The level meter supports loudness metering and is useful for managing the volume level experienced by the listener. * The resolution of SD-SDI audio quantization is up to 20 bits.
■
Stereo Headphone Output
The LV 7330 can extract the audio signal embedded in an SDI signal. You can select two channels from the extracted audio and transmit them in stereo through the headphone output connector.
■
Status Display
The status display has a number of advanced features, including SDI signal error detection and analysis features.
■
Time Code Display
The LV 7330 can decode SMPTE 12M-2 time codes (LTC or VITC) and SMPTE 266M time codes (D-VITC) and display them. These codes can be used as timestamps in the event log.
■
Screen Capture
The display can be captured. Captured displays can be viewed or superimposed over an input signal. Captured displays can be saved in internal memory (RAM) or USB memory or sent to a PC through an Ethernet connection as bitmap data.
■
Presets Settings
The LV 7330 can remember up to 30 frequently used setting configurations. The configurations can be recalled easily from the front panel or using commands sent through the Ethernet or remote connector.
■
Remote Connector
You can recall presets by sending commands through the remote connector. Also, a tally light can be displayed on the screen.
■
Ethernet Connector
From a PC connected to the LV 7330 through the Ethernet con­nector, you can recall presets, execute panel operations, transfer  les, and monitor errors.
■
Last Memory
The LV 7330 backs up the current settings so that you can use the same settings that you were using before immediately after powering it up.
■
Power Supply
The LV 7330 has an XLR DC input connector and runs on a 12­VDC power supply.
LV 7330
MULTI SDI RASTERIZER
HD-SDI
SD-SDI
External Display
Supports aspect ratios of 4:3, 16:9, and 15:9.
■
Squeeze Feature
(SNMP will be supported in the future)
Page 25
SPECIFICATIONS
LV 7330
Video Signal Formats and Corresponding Standards
Single Link System Video
Color System
Y, C
, CR 4:2:2 10 bits
B
Quantization
Scanning Frame(Field) Rate 1080i 60/59.94/50 1080p 30/29.97/25/24/23.98
1080PsF 30/29.97/25/24/23.98
720p
525i 59.94 625i 50
Format
60/59.94/50/ 30/29.97/25/24/23.98
Corresponding Standards
SMPTE 274M SMPTE 292M
SMPTE RP211 SMPTE 292M
SMPTE 296M SMPTE 292M
SMPTE 259M
(only link A is supported for dual link)
Color System
GBR 4:4:4
, CR 4:2:2
Y, C
B
Quantization
Scanning Frame(Field) Frequency
1080p 30/29.97/25/24/23.98
10 bits
1080PsF 30/29.97/25/24/23.98 1080i 60/59.94/50 1080p 30/29.97/25/24/23.98
12 bits
1080PsF 30/29.97/25/24/23.98 1080i 60/59.94/50
10 bits 1080p 60/59.94/50
1080p 30/29.97/25/24/23.98
12 bits
1080PsF 30/29.97/25/24/23.98 1080i 60/59.94/50
Format
Corresponding Standard
SMPTE 372M (1920x1080)
Format Setting: Can be set automatically based on the
corresponding format or set manually (Set manually for dual link)
Supported Sampling Frequencies
: HD:74.25 MHz or 74.25/1.001 MHz
SD:13.5 MHz
External Sync: Automatically set from the corresponding
format
Audio Playback
Compliant Standard: HD:SMPTE-299M, SD:SMPTE-272M Sampling Frequency: 48 kHz (must be synchronized to the
video signal)
Quantization: HD:24 bits, SD:20 bits Synchronization: All audio channels must be synchronized
to the video clock.
Channel Separation: 2 groups of 8 channels are selectable.
Input/Output Connectors
SDI Input Input Connector: 2 BNC connectors (A/B switching) Input Impedance: 75 Ω Input Return Loss: ≥15 dB for 5 MHz to the serial clock fre-
quency
Maximum Input Voltage
: ±2V (DC + peak AC)
External Reference Input* Input Signal: Tri-level sync or NTSC/PAL black burst
signal
Input Connector: 1 pair of BNC connectors loop-through
* If the video signal waveform o r phase difference is display ed using an e xternal sync
signal as reference, the waveform phase one clock before or after an SDI signal is inserted or the power is turned on is indenite.
AES/EBU Input Input Connector: 1 BNC connector Supported Formats: IEC 60958 Sampling Frequency: 48 kHz SDI Output Output Connector: 1 BNC connector
Reclocks and transmits the selected SDI
input signal
Output Impedance: 75 Ω Output Voltage: 800 mVp-p ± 10 % DVI-I Output Output Connector: 1 DVI-I connector Signal Format: Single Link T.M.D.S analog RGB Output Format: XGA (1024 x 768) Supports wide displays (using squeeze
methods)
DDC: Not Supported
HOT PLUG Detection
: Not Supported
Headphone Output Output Signal: The LV 7330 extracts and transmits the au-
dio signal embedded in an SDI signal.(Must be synchronized to the video signal.)
Output Connector: One 6.3-mm (1/4 in.) stereo jack Volume Adjustment: Congured in the menu Impedance: 32 Ω (16 to 600 Ω)
Control Connectors
USB Connector Function: Used to save screen captures, event
logs, preset data, and data dumps
Specications: USB 2.0 Media: Only USB memory devices are supported. Remote Connector Function: Used to recall presets, display a tally
light, and switch input channels (A/B)
Control Signal: TTL level (active-low logic) Control Connector: 15-pin D-sub (female) Ethernet (SNMP will be supported in the future) Function: Used to control the LV 7330 from a PC
and monitor errors and other events
Compliant Standard: IEEE802.3
Input/Output Connectors
: 1 RJ-45 connector
Type: 10Base-T/100Base-TX
(automatic switching)
Display Form
1 Screen Display: Picture display, CINELITE display, CIN-
EZONE display, video signal waveform display, vector display, status display, or audio display
2 Screen Display: Picture display and video signal wave-
form display Video signal waveform display and vector display Video signal waveform display and picture display Video signal waveform display and audio level display Audio waveform display and level meter display
4 Screen Display: Select audio level display or status dis-
play in addition to video signal waveform display, vectorscope display, and picture display
Format Display: Displays the video signal format at the
top of the screen.
Color System Display: Displays the video signal color system at
the top of the screen.
Date Display: Displays the date according to the inter-
nal clock at the top of the screen
Time or Time Code Display
: Displays the time according to the inter-
nal clock or a time code at the top of the screen
Time code: LTC, VITC, or D-VITC
Screen Capture
Function: Captures the screen Display: Displays the captured image or superim-
poses the captured image over the input signal
Media: Internal memory (RAM) and USB memory
Only one screen capture can be stored in the internal memory.
Data Output: Screen captures can be saved as bitmap
les or in a le format that the LV 7330 can load.
They can be saved to USB memory or
transmitted through an Ethernet and saved on a PC.
Data Input: Data saved to USB memory can be load-
ed and displayed on the LV 7330.
Presets Settings
Number of Presets: 30 Recall Method: Front panel or remote connector or Eth-
ernet command.
Copying: Preset congurations can be copied as a
group to or from USB memory.
Video Signal Waveform Display
Waveform Operations Display Modes Overlay: Overlays component signals. Parade: Displays component signals side by side.
Page 26
Timing: Computes and displays Y-CB and Y-CR.
Uses a bowtie signal.
Blanking Period: Show or hide RGB Conversion: Converts a Y,C
signal into an RGB
B,CR
signal and displays the result.
Pseudo-Composite Display
: Articially converts component signals into
composite signals and displays the result.
Channel Assignment
: In RGB conversion display, the order can
be set to GBR order or RGB order.
Line Select: Displays the selected line. Sweep Modes: H and V Vertical Axis Gain: ×1 or ×5 Variable Gain: ×0.2 to ×2.0 Amplitude Accuracy: ±0.5 % HD Frequency Characteristics Y Signal: ±0.5 % for 1 to 30 MHz C
Signals: ±0.5 % for 0.5 to 15 MHz
B,CR
Low-Pass Attenuation
: ≥ 20 dB (at 20 MHz)
SD Frequency Characteristics Y Signal: ±0.5 % for 1 to 5.75 MHz C
Signals: ±0.5 % for 0.5 to 2.75 MHz
B,CR
Low-Pass Attenuation
: ≥ 20 dB (at 3.8 MHz)
Horizontal Axis Line Display: ×1, ×10, ×20, ACTIVE, or BLANK Field Display: ×1, ×20, or ×40 Cursor Measurement Composition
Horizontal Cursors
: 2 (REF and DELTA)
Vertical Cursors: 2 (REF and DELTA)
Amplitude Measurement
: %, or V
Time Measurement: usec/msec Frequency Display: Computes and displays the frequency
with the length of one period set to the time between two cursors.
Scale Type: %, or V 75 % Marker: Displays where the location of the peak
of a 75 % color bar chrominance signal would be.
Display Colors: 7 colors to choose from
Vector Display
Gain: ×1, ×5, or IQ-MAG Variable Gain: ×0.2 to ×2.0 Amplitude Accuracy: ±0.5 % Blanking Period: Masked Scale Type: 75 % or 100 % (color bar) IQ Axis: Show or hide Display Colors: 7 colors to choose from Line Select: Displays the selected line Pseudo-Composite: Artificially converts component signals
into composite signals and displays the result.
5 Bar Display
Function: Displays ve peak levels: those of the Y, R,
G, B and composite signals.
Error Level: Based on gamut error level and compos-
ite gamut error level settings.
Filter: Removes transient errors
(The lter characteristics are the same as
for gamut errors.)
Line Select: Displays the selected line
Phase Difference Display
Display: Displays the phase difference between
an SDI signal and the external sync sig-
nal both numerically and graphically.
Display Range Vertical: ±1 eld (for interlace)
±1/2 frame (for progressive)
Horizontal*: ±1 line
* If the video signal waveform is displayed using an external sync signal as a reference,
the waveform phase one clock before or after an SDI signal is inserted or the power is turned on is indenite.
Picture Display
Image Quality Adjustment
: Brightness, contrast, chroma level, and
aperture
Display Sizes: FIT, ×1, or ×2 (HD)
FIT ×2 (SD)
Color Selection: Color or monochrome Frame Rate: The frame rate is converted and dis-
played using the internal sync signal.
Marker Displays Center Marker Aspect Markers HD: 4:3, 14:9, 13:9, 2.35:1, 1.85:1, and 1.66:1 SD: 16:9, 14:9, 13:9, 2.35:1, 1.85:1, and
1.66:1
Safe Action Markers: 95 %, 93 %, and 90 % Safe Title Markers: 88 % and 80 % Line Select: Marks the selected line
CINELITE Display
Function: f-Stop display, percentage display, and
level display
f-Stop Display: Displays the f value relative to the refer-
ence point
The reference point is set to the value of
an object with a reection level of 18 %.
f-Stop Gamma Correction Reference Gamma: 0.45 (ITU-R BT709)
User-Dened Correction Tables External Correction Tables
: 3 : 5 (read from USB memory)
Percentage Display: Displays luminance or RGB components
as percentages.
Level Display: Displays luminance or RGB components
with 256 levels (8 bits).
Measured points: 3 Measurement sizes: 1 pixel, 3 × 3 pixels, or 9 × 9 pixels
CINEZONE Display
Function: Displays the luminance levels in the pic-
ture using different colors
Display Colors: Linear (1024 colors) or step (12 colors) Upper Limit Setting: -6.3 to 109.4 % (values above the upper
limit are displayed using white)
Lower Limit Setting: -7.3 to 108.4 % (values below the lower
limit are displayed using black)
Level Search Display: Displays a specied luminance level ±0.5
% using green on an otherwise mono-
chrome picture display.
Luminance Level Setting
: -7.3 to 109.4 %
Embedded Audio Display
Lissajous Display Displayed Channels: 2 channels or 8 channels (only for em-
bedded audio)
Display Mode: X-Y or MATRIX Sound Image Display Channel Mapping: L, R, C, LFE, Ls(s), Rs, LL, RR Surround Formats: 3-1, 3-2, 3-2-2 Level Meter Display Displayed Channels: 8ch / 2ch Meter: 60 dB peak level, 90 dB peak level, aver-
age, or loudness
Peak Hold Time: 0.5 to 5.0 seconds/HOLD (when display-
ing the peak level)
Channels Group Selection: You can select any 2 groups from groups
1, 2, 3, and 4.
Audio Information: Detects the presence of each audio
channel
Sampling Frequency: 48 kHz (must be synchronized to the
video signal)
* The LV 7330 cannot display Lissajous curves, 8-channel level meters, or sound images
for AES/EBU signals that it receives.
Status Display
SDI Signal Error Detection Signal Detection: Detects the presence of an SDI signal TRS Error: Detects TRS location and protection bit
errors
Page 27
Line Number Error: Detects HD-SDI signal line number errors CRC Error: Detects HD-SDI signal transmission errors EDH Error: Detects SD-SDI signal transmission errors Gamut Error: Detects gamut errors
Detection Range Upper Limit Detection Range Lower Limit
Filter: Removes transient errors
Composite Gamut Error
Detection Range Upper Limit Detection Range Lower Limit
Filter: Removes transient errors
Parity Error: Detects ancillary data header parity errors Checksum Error: Detects ancillary data transmission errors BCH Error: Detects errors in the transmission of the
Audio CRC Error: Detects CRC errors in channel status bits
Audio Information Detection
Error Count: Up to 100,000 errors
Count Period: Only one error is counted for each sec-
Event Log Display Recording Capacity: Up to 1,000 events Description: Records all events from start to nish Recorded Events: Errors, changes in input type, time stamps,
Data Output: Event logs can be saved to USB memory
Data Dump Display Display Modes: Display data separated by serial data se-
Line Select: Displays the selected line Sample Select: Displays from the selected sample Jump Feature: Jumps to an EAV or SAV Data Output: Event logs can be saved to USB memory
Audio Status Display Control Packets: Analyzes and displays SDI signal audio
: 90.8 to 109.4 % (0.1 % step) : -7.2 to 6.1 % (0.1 % step)
Low-pass (HD: 5 MHz LPF. SD: 1.8 MHz LPF)
: Detects level errors that occur when com-
ponent signals are converted to composite signals
: 90.0 to 135.0 % (0.1 % step) : -40.0 to -20.0 % (0.1 % step)
Low-Pass (HD: 5 MHz. SD: 1.8 MHz)
audio signal embedded in an HD-SDI signal
: Detects the presence of each audio
channel
(Only the specied errors are counted.)
ond or frame.
etc.
or sent to a PC through an Ethernet con­nection as text data.
quence or by channel
or sent to a PC through an Ethernet con­nection as text data.
control packets
Channel Status: Analyzes and displays or displays the
dump of the channel status of the em­bedded audio signal
EDH Display EDH packets: Analyzes and displays received EDH
packets
Closed Caption Display Compliant Standard: ARIB STD-B37/CEA-608, ELA-708 Display Details: Analyzes and displays the closed caption
signal.
Inter-Stationary Control Data Display (NET-Q) Compliant Standard: ARIB STD-B39 Display Details: Analyzes and displays inter-stationary
control data
Data Broadcast Trigger Signal Display
Compliant Standard

V-ANC User Data Display
Standard Supported
Time Code Display
Corresponding Time Code
Display Method: Switches the display of internal clock,
Front Panel
Key LEDs: You can dimly light all of the keys by
Power Switch: Turns the power on and off. If power
Last Memory: Backs up the panel settings.
Environmental Conditions
Operating Temperature
Operating Humidity: 85 %RH or less (no condensation)
Power Supply
Voltage: 10 to 18 VDC Power Consumption: 18 W max.
Dimensions
Weight
Accessories
: ARIB STD-B35
: ARIB TR-B23
: Selects LTC or VITC SMPTE RP-188
and the time code.
pressing the shortcut key.
is removed when the switch is on, the instrument will turn on when power is restored.
: 0 to 40°C
215(W) × 44(H) × 250(D) mm (excluding protruding parts)
1.3 kg
Instruction manual ................................. 1
AC adapter (LP 1960) ............................ 1
15-pin D-sub connector ........................ 1
15-pin D-sub connector cover ............. 1
Ferrite core ............................................ 1
■LV 7330 Front Panel ■LV 7330 Rear Panel
215 mm
250 mm
44 mm
■Rack Mounting
LR 2481 Rack Mount Adapter (sold separately)
Page 28
LV 5152
LV 5152 REAR PANEL
Displays Analog Component Signals of Multi-Format DTV Monitoring with Conversion Matrix (Y, P
B
, PR, to GBR)
MULTI FORMAT WAVEFORM MONITOR
28
The cabinet is sold separately.
The LV 5152 Multi-format Waveform Monitor is designed to display analog component signals of multi-format DTV. This instrument features two analog component signal input sys­tems. In addition to the waveform monitor function, vector, timing, and audio signal display functions are provided. Moreover, the full line selector function and control setting menu are provided.
FEATURES
Comply DTV for U.S.A. and Europe
Accepts eight analog video formats for DTV-USA and three analog video formats for DTV-Europe.
Two analog signal input systems (Y, P
B, PR or GBR) are
provided.
Picture monitor output is provided.
Vectorscope function (SMPTE 274M, 296M)
Displays color difference signal of component signals in vector format. The analog GBR signal is converted into color difference signal with a matrix and displayed in vector format.
Conversion matrix, Y, P
B, PR into GBR (SMPTE 274M,
296M)
Simplifies signal level monitoring.
Measurements using cursor
Ensures level measurement with 0.5% accuracy.
Preset memory function
Stores/recalls up to 10 panel settings to reduce setup time by presetting frequently used measurement conditions.
Basic Operation Mode WFM(Waveform monitor mode)
Displays up to three channel waveforms.
VEC(Vectorscope mode)
Vector display of P
B and PR channel input signals.
PIC(Picture monitor mode)
Monochrome display of Y/G channel input signals.
AUDIO(Audio mode)
Lissajous display of analog stereo audio signal.
Page 29
29
LV 5152 SPECIFICATIONS
Measurement Signal and Standards
Input System
Signal Input
Input Channel Input Connector Retaurn Loss Impedance Maximum Input Voltage
EXT REF Input
Input Channel Input Connector Return Loss Impedance
Maximum Input Voltage Sync Amplitude Picture Monitor Output
Frequency Response Output Impedance Output Connector Amplitude
Vertical Axis
Deflection System
Deflection Sensitivity
Variable Range
GBR Matrix
Deflection Sensitivity
Frequency Response
FLAT
LOWPASS
Attenuation
DIF'D STEP
Attenuation
Step Response
DC Restorer
Frequency Response
Slow Mode
Fast Mode
Clamp
Point
Variable Range
Blanking Level Shift Horizontal Axis
Operation Mode
Display Method
Line:
Line Magnified
Field:
Field Magnified
Time Base Accuracy Linearity
Vectorscope Mode
Frequency Range Amplitude Accuracy
CH1(Y/G),CH2(P
B/B),CH3(P
R/R),2-system
BNC 30 dB, 50 kHz to 30 MHz (both power on/off) 75 passive loop-through ±2 V (DC + peak AC)
EXT REF, 1-system BNC 30 dB, 50 kHz to 30 MHz (both power on/off) 75 passive loop-through ±12 V (DC + peak AC)
0.3 Vp-p ±6 dB
25 Hz to 30 MHz, within ± 5 % 75 BNC, 1 system 1 V ± 5 %
Within ± 1 %, GAIN x 1 Within ± 3 %, GAIN x 5 At least 0.5 to 1.2 times (both GAIN x 1 / x 5)
Within ± 1 %, GAIN x 1 Within ± 3 %, GAIN x 5 x 1 GAIN Within ± 1 %, 25 Hz to 30 MHz (50 kHz ref., GBR Matrix OFF mode)
20 dB, at 20 MHz (50 kHz ref.)
20 dB, at 30 kHz (1.6 MHz ref.)20 dB, at 7 MHz (1.6 MHz ref.)
For 2T pulse, 2T bar Within ± 1 %, pulse/bar ratio Within ± 1 %, overshoot Within ± 1 %, preshoot Within ± 1 %, ringing Within ± 1 %, sag (vertical tilt)
20 %, attenuation at 60 Hz input80 %, attenuation at 60 Hz input
Back porch
0.5 to 2 µs, relative to sync pulse raising edge 1 % (10 to 90 % of APL Variation)
Overlay: Displays waveforms overlaid Parade: Displays waveforms side by side Timing: For bowtie signal* measurement * Authorized by Tektronix, Inc.
1H, 2H, 3H 1H MAG, 2H MAG, 3H MAG 1V, 2V, 3V 1V MAG, 2V MAG, 3V MAG Within ±3 % (0.1 µs/ div) Within ±3 %
1 MHz ±2 % (Y, P
B, PR Input)
±2 % (G, B, R Input)
Variable Range
Graticule Sync Blanking
Picture Monitor Mode
Audio Mode
Calibration Accuracy Full Scale Bandwidth
X-Y Phase Accuracy Calibration Signal Line Selector
Operation Mode
Operation Field
Display Line Window
Function
Window Range
Operation Mode
Operation Field Preset Function
Preset/ Recall
Controls
Remote Control
Control Signal
Control Input Cursor Measurement
Configuration
Amplitude Measurement
Measurement Range Accuracy Resolution
Amplitude Ratio Measurement
Time Measurement
Measurement Range Accuracy Resolution
Time Ratio Measurement
Frequency Measurement
CRT
Effective Display Area
Graticule
Environmental Conditions
Operating Temperature
Operating Humidity
Operating Environment
Operating Altitude
Overvoltage Category
Pollution Degree Power Requirements Dimensions and Weight
Accessories
Optional Accessories
At least 0.5 to 1.2 times (both GAIN x1 / x5) (for vertical and horizontal axes) Electronic graticule Blanks sync dot
Displays picture using the Y or G signal. The picture is horizontally reduced in size because the CRT aspect ratio is not 16:9.
±0.5 dB of full sale 0, 2, 4 dBm (menu selectable) Within –3 dB at 20 kHz Within 1 ˚ at 20 kHz
1 V ±0.5 %
WFM, VEC, PIC FLD1, FLD2, ALL (at Interlace) Only ALL at 1080/50i (1250Line). The selected line is intensified
Displays brighter by overlaying multiple lines resulting in higher effective refresh rate. 1 to 15 lines WFM, VEC, PIC FLD1, FLD2, ALL (at Interlace)
Up to 10 front panel controls All front panel controls (except INTEN, READOUT INTEN, ROTATION, FOCUS, ILLUM, POWER)
TTL (low active) D-sub, 25-pin (REMOTE), rear panel
Two horizontal cursors (REF, ∆) Two vertical cursors (REF, ∆) Voltage (V or %) between the REF and cursors 0 to 2000 mV, 0 to 280.0 % ±0.5 % 1 mV or 0.1 % Amplitude between the REF and cursors rela­tive to 100 % REF is displayed in R%. Measures time between the REF and cursors At least ±6 div from graticule center ±3 % 1/ 80 div When [ R% ] is selected with the menu, time between the REF and cursors relative to 100 % REF is displayed in R%. Frequency of one cycle between the REF and cursors
80 x 100 mm Internal (waveform) External (vector) Electronically-generated (vector, audio)
0 to 40 ˚C 90 % RH (without condensation) Indoor use up to 2000 m II 2
90 to 250 VAC, 48 to 440 Hz, 60 W max. 215 (W) x 132 (H) x 429 (D) mm, 5.5 kg
8 1/2(W) x 5 1/4(H) x 16 3/4(D) in., 12.1 lbs
Illumination lamp...............................................5
25-pin D-sub connector....................................1
25-pin D-sub connector cover..........................1
Screw, rack mounting (inch size) .....................2
Cover, inlet stopper ..........................................1
Power cord .......................................................1
Instruction manual ............................................1
LR 2427B (Cabinet, with handle) LR 2404A (Cabinet, without handle) LR 2700A-I (Rack-Mount Adapter, inch size)
No Format
FullLine/Flame Frequency
Complied Spec. 1 1080/60i 1125/29.97(30) SMTPE 274M 2 1080/50i 1125/25 SMTPE 274M 3 1080/24P 1125/23.98(24) SMTPE 274M 4 1080/24sF 1125/23.98(24) SMTPE 274M 5 720/60P 750/59.94(60) SMPTE 296M 6 720/50P 750/25 SMPTE 296M 7 480/60P 525/59.94(60) SMPTE 293M 8 480/60i 525/59.97(30) SMPTE 253M 9 1080/50i 1250/25 SMTPE 295M
10 576/50P 625/50 ITU-R BT.1358 11 576/50i 625/25 ITU-R BT.601-4
Page 30
WAVEFORM MONITOR
30
5222
The Model 5222 is a precision Waveform Monitor designed to monitor video signals. The 5222 with its bright CRT adds such extra features to conventional waveform monitors as a line selector, picture monitor mode, X-Y display mode for stereo audio signals, and menu screen for setting functions. These instruments have eight video inputs and one external reference input channel. Up to four waveforms, component or composite signals, and the external reference can be dis­played side-by-side to reduce system size. These instruments can also be remotely controlled when combined with the 5212 Vectorscope.
Precise Video Signal Level Measurements with Cursor Provides Full Component Monitoring Capability
PAT. PEND. The cabinet is sold separately.
Eight video inputs and one external reference input channel
These instruments have eight video inputs and one external reference input channel. Up to four waveforms, including the external reference, can, be displayed simultaneously. The parade (side-by-side) or ALT (overlaid) display is selec­table. The component signal can be displayed in the bowtie con­figuration. (Bowtie signal: U.S. PATENT 4,829,366 is used with permission of Tektronix, Inc.)
Menu function
For user-friendly front panel control, a menu controller is provided for various functions.
Dual filter
Both FLAT and LUM (low-pass filter) filtered characteristics can be displayed simultaneously.
Preset function
The front panel settings, including vertical and horizontal positioning, can be stored in memory, and recalled from the front panel or via the remote control connector on the rear panel. You can reduce setup time by presetting frequently used measuring conditions.
Clamp position setting
The clamp point can be set at any position, with the position being highlighted on the waveform.
RGB/YRGB display function
Y/C input connectors
Bright CRT, accelerating potential of 16.5 kV
Universal AC power supply, 90 to 250 V
FEATURES
Precise measurements with cursor
The cursor permits signal level measurements with 0.5% accuracy.
Full line selector
Since one or two lines of a video signal can be displayed, you can conveniently observe VITS, VIR, or teletext signals. The function also helps to test video camera characteristics.
Picture display function
These instruments can display video signals as a TV picture even without a picture monitor. In the line selector mode, the selected line is highlighted for identification on the picture.
Page 31
31
5222 SPECIFICATIONS
CRT
Type Accelerating Potential Effective Display Area Graticule
Input
Input Channel
Input Impedance Maximum Input Voltage Return Loss Isolation between Channels Gain Difference Between Channels
Loop Through Isolation Measurement Signal Vertical Axis
Deflection Factor
Variable Range
Filter
FLAT
LUM
Attenuation CHROMA Band-Pass Filter
Bandwidth
Bandwidth error
Amplitude error DIF'D STEP
Gain
Attenuation
Attenuation Step Response
Overshoot
Preshoot
Ringing
Pulse/Bar Ratio
Vertical Tilt DG
DC Restoration
Frequency Response
Slow Mode
Fast Mode
Clamp Point
Variable Range
Blanking Level Shift
Video Output
Frequency Response Input /Output Gain Ratio Return Loss DG, DP
Horizontal Axis
Time Accuracy
Sweep Length Linearity Position Control Range
RGB/YRGB
Selectable Staircase Input Maximum Input Voltage
CAL
Amplitude
EXT REF
Input Impedance Return Loss Maximum Input Voltage
150 mm rectangular (P4)
16.5 kV 100 (H)×80 (V) mm
Illuminated internal graticule
(625) (525)
CHA: 1, 2, 3, 4 CH1, 2, 3 CHB: 1, 2, 3, 4 15 k, 75 loop-through ±2 V (DC+peak AC)
40 dB, 50 kHz to 6 MHz60 dB, (Fsc)
0.5% CH1 to CH470 dB (Fsc)
NTSC/PAL/SECAM video signal (625/50)
±1%: 1 Vp-p full scale (140 IRE ref) ±3%: ×5
±0.5%: Cursor measurement
0.5 Vp-p to 1.45 Vp-p: ×1 full scale
0.1 Vp-p to 0.29 Vp-p: ×5
Within ±2% (25 Hz to 6 MHz) Within+2 to
5% (6 MHz to 8 MHz)
(50 kHz ref.)
35 dB (Fsc)
(625) (525)
Fac ±2.4 MHz Fac ±2.2 MHz
2.4 MHz ±200 kHz 2.2 MHz ±200 kHz 1% (Fsc) 400 kHz band-pass filter
×
5 ±10% (FLAT ref.)
20 dB (14 kHz, 2 MHz) 400 kHz ref.40 dB (Fsc) 400 kHz ref.
For 1 V full scale, FLAT, 2T pulse, 2T bar ±2% or less ±1% or less ±2% or less Within ±1% (0.99: 1 to 1.01: 1) Within 1%
1%
20% (absolute attenuation value for 60 Hz
input) 80% (absolute attenuation value for 60 Hz input) Back porch 5 to 7 µs or more (with respect to sync pulse leading edge) 1% (With 10 to 90% APL or color burst on/off)
Within ±3% (25 Hz to 6 MHz)
1.1 ±3% (75 Ω term.)
30 dB (50 kHz to 6 MHz)1%,
Within ±3% (1 µs/div) Within ±3% (0.2 µs/div)
12.5 div ±0.7 div Within ±3% Anywhere in the screen
Factory setting: RGB 10 V ±15%, 9 divisions display ±12 V (DC+peak AC)
1 V ±0.5%
15 k, 75 loop-through40 dB (50 kHz to 6 MHz)
±12 V (DC+peak AC)
Synchronization
Sync Amplitude
INT EXT
Remote Sync Sensitivity
Line Selector
Field 1, 3 Field 2, 4 ALL
Preset Function
Controllable Functions
Remote Control
Combinations Controllable Functions
Control Input
Cursors
Configuration
Amplitude Measurement
Measurement Range
Calibration Accuracy Resolution
Time Measurement
Measurement Range Calibration Accuracy Resolution
Frequency Measurement
Environmental Conditions
Operating
Spec-Guaranteed
Power Requirements
Power Consumption
Dimensions and Weight
Supplied Accessories
Optional Accessories
5222: CH1A, 4A, 1B, 4B
(625) (525)
0.3 Vp-p ±6 dB 0.286 Vp-p ±6 dB
0.3 Vp-p ±6 dB 0.286 Vp-p ±6 dB 143 mV to 4 V composite sync amplitude
2.0 to 5.0 V square wave or 4.0 V composite sync (activates at sync leading edge)
(625) (525)
Line 1 to 313 Line 1 to 263 Line 314 to 625 Line 1 to 262 Line 1 to 312 Line 1 to 262
Up to 10 panel settings, Recallable All front panel controls (except REMOTE, INTEN, ROTATION, FOCUS, GAIN VAR, POWER)
5222 → 5212 (NTSC/PAL/SECAM) All front panel controls (except INTEN, ROTATION, FOCUS, GAIN VAR, POWER) Rear panel D-sub, 15-pin (REMOTE A) D-sub, 9-pin (REMOTE B)
Horizontal cursors (REF, ∆) Vertical cursors (REF, ∆) Voltage between the REF and cursors Unit: V, IRE, %
(625) (525)
0 to 2000.0 mV 0 to 2000.0 mV 0 to 286.0% 0 to 280.0 IRE
0.5%, vertical
0.5 mV, 0.1 IRE, or 0.1% Time between the REF and cursors ±6 div or more from center ±3% 1/80 div Frequency between the REF and cursors those apart 1 cycle
Temperature: 0 to 40°C Humidity: 90% RH (without condensation) Temperature: 10 to 35°C Humidity: 80% RH (without condensation)
90 to 250 VAC, 48 to 440 Hz 50 Wmax.
215 (W)×132 (H)×429 (D) mm, 4.2 kg 8 1/2 (W)×5 1/4 (H)×16 3/4 (D) in., 9.3 lbs
Illumination lamp
5
Screw, rack mounting (inch size)
2
15-pin D-sub connector
1
Metal case, 15-pin D-sub connector
1
Power cord
1
Cover, inlet stopper
1
Screw lock
2
E-ring
1
Instruction manual
1
LR 2427B (Cabinet, with handle) LR 2404A (Cabinet, without handle) LR 2700A-I (Rack-Mount Adapter, inch size)
5222 REAR PANEL
Page 32
WAVEFORM MONITOR
32
5861V
(PAL) 5860V(NTSC)
The 5861V and 5860V Waveform Monitors are oscilloscopes that are capable of quick monitoring amplitude, time and fre­quency response, etc. of composite TV signals, which are hard for ordinary oscilloscopes to measure. The waveform monitor is equipped with various modes and trigger functions that are optimum to video signal monitoring. Such various modes as 2H, 1H, 1 µs/div, 2V, 1V, and 2V MAG can be selected by the horizontal axis sweep. As FLAT, LUM (5861V), IRE (5860V), CHROMA, DIF GAIN and DIF'D STEP can be switched, it is possible to observe various characteris­tics of video signals. Furthermore, the line selector function is provided for observ­ing VITS and VIR signals which are inserted during the vertical blanking period. In addition, the blanking output connector for blanking other periods that lines selected by the line selector, video output connector and other functions necessary for video signal monitoring are provided.
FEATURES
•Depending on synchronization system and subcarrier fre­quency, the 5860V is compatible with the M system, and 5861V is compatible with the B, C, D, G, H, I, and K sys­tems.
•Differentiated-step methods are used to display the differen­tial of staircase signals to make measuring the linearity of transmission system luminance components easier.
•Built-in line selector function for monitoring VITS and VIR signals, a blanking output and a video output.
•Horizontal sweep mode selection from 2H, 1H, 1 µs/div, 2V, 1V, and 2V MAG. The frequency response of the vertical axis is switchable among FLAT, LUM (5861V), IRE (5860V), CHROMA, DIF GAIN, and DIF'D STEP.
•K factor scale provided for checking of frequency charac­teristics.
5860V FRONT PANEL
5861V REAR PANEL
Measurements of Composite Video Signal Amplitude, Timing, and Frequency Response
5860V
5861V
(5861V only)
Page 33
33
5861V
(PAL)
5860V
(NTSC)
SPECIFICATIONS
5861V WAVEFORMS DISPLAY
Model
CRT
Type
Accelerating Potential Effective Display Area Beam Rotator
Input Section
Input Connector
Input Impedance
Maximum Input
Full Scale Graticule
Full Scale SYNC VIDEO
Deflection Accuracy
1 V Full-scale Range
4 V Full-scale Range
Frequency Characteristics
FLAT
LUM
IRE
CHROMA
DIF GAIN
DIF'D STEP
Transient Response
Sag (Vertical window signal) Variable Range
1 V Full-scale Range 4 V Full-scale Range DC Regeneration
5861V 5860V
150 mm rectangular, internal graticule with scale illumination 12 kV 80 (V)×100 (H) mm Adjustable from the front panel
A and B on the rear panel (loop-through, BNC connector) 1 Vp-p full scale range: 15 kΩ, 50 pF 4 Vp-p full scale range: 60 kΩ, 50 pF
±5 V (DC+peak AC), AC coupled
1.0 scale
0.3 scale
0.7 scale
Within ±2% of 1.0 scale at 1 V input Within ±4% of 1.0 scale at 4 V input
25 Hz to 3.6 MHz ±2%, 3.6 MHz to 5 MHz+2%,
5% at 50 kHz reference More than 35 dB of attenuation at 4.43 Mz
4.43 MHz bandpass filter Response: Within ±2% at filter FLAT
4.43 MHz bandpass filter 3 to 5.5 times of CHROMA amplitude For measuring the linearity of luminance
450 kHz bandpass filter
Response at filter "FLAT"
400 kHz: Within ±2% 500 kHz: Within +0,
20%
14 kHz, 2 MHz: Within
90%
3.58 MHz (5861V), 4.43 MHz (5860V):
99% ±1.5% or less in overshoot, preshoot, and ringing using the sin
2
pulse & bar signal at FLAT with 1 V full scale range. 2% or less Input voltage of 1.0 full scale
0.25 V or less to 1 V 1 V or less to 4 V Clamped at the back porch
Model
Video Output
Output Connector Output Voltage Output Impedance Frequency Characteristics
Sweep
1H Sweep 2H Sweep 1 µs/div 1V Sweep 2V Sweep 2V MAG Sweep Linearity RGB/YRGB Display Staircase Maximum Input Voltage Sweep
Sweep Line Length
Composite to YRGB
Control Signal Control Signal RGB and YRGB Input
External Synchronization
Input Connector Input Impedance Input Sensitivity
Maximum Input Voltage
Line Selector
Display Line
Blanking Output
Output Connector Voltage Level
Calibrator
Waveform Amplitude Frequency
Environmental Conditions
Operating Power Requirements Dimensions and Weight
Accessories
5861V 5860V
BNC connector on the rear panel 1 V ±15% at full scale input 75 ±10% 25 Hz to 5 MHz ±5%
Display of 1H waveform Display of 2H waveform 10 times magnification of 2H sweep, 1 µs/div ±3% Display of 1 V waveform Display of 2 V waveform Approx. 20 times magnification of 2V sweep ±3% RGB is standard. (YRGB is optional.) 10 V ±15%/9 div ±12 V (DC+peak AC) 1H display at 2H sweep 1V display at 2V sweep RGB: 30%×3 or composite display YRGB: 22%×4 of composite display Remote control from external or internal control signal 12 to 15 V (negative or positive), 15 mA 9-pin MT socket on the rear panel 9-pin D-sub connector (option)
2 terminals, BNC, loop-through type on the rear panel 15 k
0.143 to 5 Vp-p (Level of sync signal in composite video signal) ±8 Vp-p
13 to 22 and 325 to
14 to 21 lines of first and
334 lines
second fields
BNC connector on the rear panel 0 V: selected by line selector
2 V: for other duration
Square waveform 1 Vp-p ±1% 32 kHz
Temperature: 0 to 40°C 100, 120, 200, 240 VAC, 50/60 Hz, 50 Wmax. 215 (W)×132 (H)×429 (D) mm, 7.4 kg 8 1/2 (W)×5 1/4 (H)×16 3/4 (D) in., 16.3 lbs Scale illumination lamp
5
9-pin MT plug
1
Cover/lnlet stopper
1
Screw, rack mounting(inch size)
2
Power cord
1
Instruction manual
1
140 IRE 40 IRE 100 IRE
Within ±2% of 140 IRE at 1 V input Within ±4% of 140 IRE at 4 V input
Conforms to IRE STD23S-1 (1958); more than 22 dB of attenuation at 4.43 MHz
3.58 MHz bandpass filter
3.58 MHz bandpass filter
±2 IRE or less in overshoot, preshoot, and ringing using the sin
2
pulse & bar signal at FLAT with 1 V full scale range.
Input voltage of 140 IRE full scale
•Sweep Range
•Frequency Response Range
2H
FLAT LUM CHROMA DIF GAIN DIF'D STEP
1 µs/div 2V 2V MAG
Page 34
VECTOR SCOPE
34
5212
The Model 5212 is precision Vectorscope designed to moni­tor video signals. The 5212 with its bright CRT features a vec­tor display, DG/DP function to measure differential gain and differential phase with a line display, X-Y display mode for stereo audio signals, and menu screen for setting functions. These instruments have three video inputs and one external reference input channel. Up to four waveforms, including the external reference, can be displayed. The newly developed digital phase control ensures a phase measurement accuracy of within 1%. These instruments can also be remotely con­trolled when combined with the 5222 Waveform Monitor.
Precise DG/DP Measurements with CRT Readout Three Video Inputs, One External Reference Input X-Y Display Capability, Auto Phase & Mag Burst
PAT. PEND. The cabinet is sold separately.
X-Y display function
The level and phase of stereo audio signals can be mea­sured.
Menu function
For user-friendly front panel control, a menu controller is provided for various functions.
Preset function
The front panel settings, including vertical and horizontal positioning, can be stored in memory, and recalled from the front panel or via the remote control connector on the rear panel. Yon can reduce setup time by presetting frequently used measuring conditions.
Automatic NTSC/PAL system discriminator
The 5212 automatically selects the NTSC or PAL color sys­tem.
Y/C input
The C signal vector can be displayed by respectively apply­ing the Y signal and C-signal to the CH1 and CH2 input con­nectors.
Remote control
These instruments can also be remotely controlled when combined with the 5222 Waveform Monitor. The line select­ed by the waveform monitor is displayed automatically.
Bright CRT, accelerating potential of 16.5 kV
Universal AC power supply, 90 to 250 V
FEATURES
Three video inputs and one external referenceinput channel
Up to four waveforms, including the external reference, can be displayed simultaneously.
Digital phase control
The newly developed digital phase control ensures a phase measurement accuracy of within 1% and display resolution of within 0.1° with alphanumeric readout.
DG/DP measuring function
These instruments enable accurate measurement of differ­ential gain (DG) and differential phase (DP) with alphanu­meric readout.
Page 35
35
5212 SPECIFICATIONS
CRT
Type Accelerating Potential Effective Display Area Graticule
Input
Input Channel Input Impedance Maximum Input Voltage Return Loss Isolation Between Channels Gain Difference Between Channels Phase Difference Between Channels Loop-Through Isolation
Synchronization
Sync Amplitude
CH1, 2, 3
Video Signal
EXT
Video Signal
Subcarrier Signal Selection
Vector Mode
Bandwidth
Upper -3 dB Point Lower -3 dB Point Center Frequency (Fsc)
Display
Phase Accuracy
Amplitude Accuracy
Digital Phase Control
Phase Accuracy
Subcarrier Regeneration
Pull-In Range Pull-In Time Phase Control Range Phase Shift Phase Shift Burst Jitter
Position Variable Range
Vertical Position Horizontal Position
DG/DP Mode
Measurement Accuracy
DG DP
Position Control Range
Vertical Position Horizontal Position
Auto Setup
DG Setup Accuracy DP Setup Accuracy
X-Y Mode
Input
Input Impedance Calibration Accuracy Input Amplitude
Maximum Input Voltage Frequency Response X-Y Phase Difference Input Connector V Position Control Range H Position Control Range
150 mm rectangular (P4)
16.5 kV 100 (H)×80 (V) mm
Illuminated internal graticule
CH1, CH2, CH3, EXT 15 k, 75 loop-through ±12 V (DC+peak AC)
40 dB (50 kHz to 6 MHz)70 dB (Fsc)±0.5%±0.5% (Fsc)70 dB (Fsc)
PAL NTSC
Burst, sync amplitude Burst, sync amplitude
0.3 Vp-p ±6 dB 0.286 Vp-p ±6 dB
Burst, sync amplitude Burst, sync amplitude
0.3 Vp-p ±6 dB 0.286 Vp-p ±6 dB 2 Vp-p ±6 dB Video or subcarrier, selectable
PAL NTSC
Fsc+500 kHz ±100 kHz Fsc+500 kHz ±100 kHz Fsc−500 kHz ±100 kHz Fsc−500 kHz ±100 kHz
4.43361875 MHz 3.579545 MHz Color bars 75%, 100% MAG mode setting OFF: Within ±1° BURST: Within ±2°
×
5 MAG: Within ±2° OFF: Within ±3% BURST: Within ±3%
×
5 MAG: Within ±5%
Within ±0.5°
Within ±150 Hz Within 1 sec 360° Within ±2° (Fsc ±50 Hz) Within ±2° (Burst amplitude ±6 dB) ±0.5°
At least ±8 mm from center At least ±8 mm from center
Within ±0.5% Within ±0.5°
±40 mm ±4 mm from center At least ±8 mm from center At CAL position Within ±2% Within ±2°
DC-coupled differential inputs (Balanced input) 20 k Within ±3% 0 dBm to 12 dBm (600 Ω) (0.775 V to 3.1 Vrms) ±12 V (DC+peak AC) DC to 20 kHz, 3 dB 1° (20 kHz) 15-Pin D-sub connector (rear panel) At least ±8 mm from center At least ±8 mm from center
GAIN
GAIN Variable Range Phase Shift by GAIN
Auto Phase
Accuracy
REF SET
VECT Mode DG Mode DP Mode
Preset Function
Controllable Functions
Remote Control
Combinations Line Selection
Recall Function Controllable Functions Control Signal Input Connector
CRT Readout
Color System Phase
Display Resolution NTSC Setup REF Channel DG
Display Resolution DP
Display Resolution X-Y Display Recall Mode Y/C Display
Environmental Conditions
Operating
Spec-Guaranteed
Power Requirements
Power Consumption
Dimensions and Weight
Supplied Accessories
Optional Accessories
+3 dB to
14 dB or more
Within ±1° (+3 dB to
6 dB)
Burst phase is set to-(B-Y) axis. Within ±2°
PHASE display is set to 0.0° DG display is set to 0.00% DP display is set to 0.00°
Up to 10 panel settings All front panel controls (except INTEN, FOCUS. ROTATION, ILLUM, GAIN, VAR, POWER), and Menu (SYSTEM, DISPLAY)
5222 → 5212 (NTSC/PAL) Full line selection capability Window display capability Available INPUT, REF, Y/C, RECALL TTL, low active D-sub, 9-pin (rear panel)
NTSC/PAL (SYNC ABSENT)
0.0° to 359.9°
0.1° SETUP 7.5%/SETUP 0% CH1, CH2, CH3, EXT +10.00% to
10.00% (DG mode)
0.01% +10.00° to
10.00° (DP mode)
0.01° X-Y scale is displayed (X-Y mode). Address to be recalled Y/C is displayed (Y/C mode).
Temperature: 0 to 40°C Humidity: 90% RH (without condensation) Temperature: 10 to 35°C Humidity: 80% RH (without condensation)
90 to 250 VAC, 48 to 440 Hz 55 Wmax.
215 (W)×132 (H)×429 (D) mm, 4 kg 8 1/2 (W)×5 1/4 (H)×16 3/4 (D) in., 8.8 lbs
Illumination lamp
5
Screw, rack mounting (inch size)
2
15-pin D-sub connector
1
Metal case, 15-pin D-sub connector
1
9-pin to 9-pin D-sub connector cable
1
Power cord
1
Cover, inlet stopper
1
Screw lock
6
E-ring
3
Instruction manual
1
LR 2427B (Cabinet, with handle) LR 2404A (Cabinet, without handle) LR 2700A-I (Rack-Mount Adapter, inch size)
5212 REAR PANEL
Page 36
VECTOR SCOPE
36
5850V
(NTSC)
The 5850V Vectorscope is designed to simultaneously mea­sure the amplitude and phase of chrominance components contained in a composite video signal. To measure phase (i.e., direction with respect to burst signal) and amplitude (i.e., length from center) in vector format, the chrominance components containing color information of the video signal are first demodulated, then displayed on the CRT. VITS and VTR can also be displayed in vector format by applying blanking signal output from the waveform monitor to Z INPUT of the vectorscope.
FEATUREFS
•The 150 mm rectangular CRT with internal graticule (with the scale illumination), it is possible to measure without parallax reading error.
•DP and DG measurements enable using the modulated staircase.
•Use with a waveform monitor to observe the vector VITS and VIR signals.
•The optional rackmount adapter enables a pattern genera­tor, color monitor, and vectorscope to be integrated in a sys­tem.
5850V REAR PANEL
Vector Display for Composite Video Signal
Page 37
37
5850V
(NTSC)
SPECIFICATIONS
THE ANGLES FOR EACH HUE 5850V
CRT
Type
Accelerating Potential Effective Display Area Beam Rotator Graticule
Composite Video Signal Input
Input
Input Impedance Max. Input Voltage Sensitvity
Calibrated Value
EXT REF
Blanking Input
Sensitivity Polarity
Chrominance
Bandwidth
Phase Accuracy Amplitude Accuracy Differential Phase Differential Gain
Measurement Item
Vector Measurement
150 mm rectangular, internal graticule with scale illumination 12 kV 80 (V)×100 (H) mm Adjustable from the front panel Internal scale Allowable frame: ±20%/ ±10° of standard color bar, circle, angle, R-Y axis, B-Y axis, I axis, Q axis, DG and DP, ±2.5 IRE/±2.5° of standard color bar, and ±20 %/ ±10° of burst signal
A, B and EXT REF on the rear panel (loop-through, BNC connector) A, B: 2 M, EXT REF: 10 k
±5 V (DC+peak AC)
Color Saturation: 75%, 100%, full scale Amplitude: 1 Vp-p, 1.24 Vp-p Variable Range: 0.5 to 5 times of the calibrated value Subcarrier: 2 Vp-p ±6 dB Black Burst: 0.43 Vp-p ±6 dB
DC ±1 V Brightens With positive voltage
Center: Fsc=3.579545 MHz High Freq.=Fsc +500 kHz Low Freq.=Fsc -500 kHz ±2° ±3% ±1° ±1%
Phase and amplitudeofchrominance component in 75% or 100% saturation color bar signal
Horizontal Synchronization
Input
Sync Polarity Sync Level Range
Subcarrier Signal Synchronization
Synchronization by Burst Signal (of composite video signal)
Sync Level Range Synchronization by External Subcarrier Signal (which is applied to the EXT REF input)
Subcarrier Signal Sync
Level Range Synchronization by Black Burst Signal (which is applied to the EXT REF input)
Black Burst Sync Level
Range
Subcarrier Frequency
Sync Capture Range
Phase Adjustment Range Calibration
Test Circle
Power Requirements
Dimensions and Weight
Accessories
Synchronization by the horizontal sync signal of composite video signal from input A or B. Negative
0.286 Vp-p ±6 dB
0.286 Vp-p ±6 dB
2 Vp-p ±6 dB
0.43 Vp-p ±6 dB Note: The external subcarrier signal is switched to and from the black burst signal internally. (set in black burst mode at shipment)
3.579545 MHz ±50 Hz (0°C to 40°C) 360°, continuously variable
Set the chrominance signal applied from the input connector in asynchronous mode. 100, 120, 200, 240 VAC, selectable by internal wiring 50/60 Hz, 40 Wmax. 215 (W)×132 (H)×429 (D) mm, 7.3 kg 8 1/2 (W)×5 1/4 (H)×16 3/4 (D) in, 16.1 lbs Illumination lamp
5
Cover/Inlet stopper
1
Screw, rack mounting (inch size)
2
Power cord
1
Instruction manual
1
123° 103.4° 60.8°
33°
347.1°
303°283.4°240.8°
213°
167.1°
-(B-Y) BURST
-(R-Y)
R-Y
B-Y
Page 38
38
MULTI FORMAT VIDEO GENERATOR MAINFRAME
LT 443D
The LT 443D Signal Generator can be flexibly used for the mul­tiformat digital broadcast systems. Various plug-in units enable the output of SDI signals (i.e., HDTV, SDTV), sync signals, and analog signals. By using these signals and genlock functions, users can customize this signal generator as desired.
FEATURES
Plug-in units provide various functions
Since up to four plug-in units can be installed in the main­frame (consisting of a power supply, main signal generator, and controller), users can customize this signal generator as desired. *1 The plug-in unit is installed at the factory; user cannnot
replace the unit.
Applicable to multiformat HDTV
For the SDI signals, 14 HDTV format unit and 525 line/625 line SDTV unit are provided. The NTSC/PAL analog video signal unit is also available. Since each unit can output the signal simultaneously, a mul­tiformat system can be constructed to satisfy user's require­ments.
Various sync output
Two units can simultaneously output HD signals with 74.25 MHz clock and 74.25/1.001 MHz clock.
Easy-to-use sync signals
For today's modern age of digital TV systems, BB signal (for NTSC/PAL) and HDTV tri-level sync signals can be generat­ed from the Analog BB Unit.
Ethernet provided
Since the ethernet capability is provided as standard. This feature can remotely control various functions and monitor the genlock status.
User-friendly operability
Leader's traditional design and operability concepts are also reflected in this instrument. User-friendly operation includes significantly reduced power-on initialization time is advantageous to a high-performance instrument.
Reading logo mark data
OPTION
LT 443D-70 (NATURAL Picture Memory: Option 70)
This option adds the NATURAL picture pattern output capability to the LT 443D mainframe. A compact flash memory card is used as an additional memory to store the NATURAL picture pattern.
Various plug-in units expand the capability of the Multiformat Signal Generator.
Compartment
Number of compartments
ID Function
LCD Panel
Number of Characters
Internal Clock
Internal Reference Frequency Memory Card Slot
Applicable Card
Function
External Interface
Ethernet
USB
(Universal Serial Bus)
General Specifications Environmental Conditions
Operating Temperature Range
Operating Humidity Range
Spec-Guaranteed Temperature Range
Spec-Guaranteed Humidity Range
Operating Environment
Operating Altitude
Overvoltage Category
Pollution Degree Power Requirements Power Consumption Dimensions and Weight
Accessories
4 Automatically identifies the unit installed. *2 Refer to specifications of each unit.
20 characters x 2 lines can be displayed (W/backlight)
27 MHz
Compact flash memory card (CFA TYPE-1) *3 Storing/reading preset data Reading logo mark data Reading NATURAL PICTURE data *4 *3 No compact flash memory card is sup­plied as standard accessory. Memory cards produced by following manu­facturers should be procured (as of August
2002):SanDisk *4 The NATURAL picture function is only usable when the LT 443D-70 Option is installed in the mainframe.
10Base-T/100 Base-T (Automatic selection) Applicable to USB 1.1 This function will be supported.
0 to 40 ˚C 90% RH (without condensation) 10 to 35 ˚C 85% RH (without condensation) Indoor use Up to 2000 m II 2 90 to 250 VAC, 50/60 Hz Approx. 150 W max. (Approx. 75 W max. *5) 426 (W) x 44 (H) x 560 (D) mm, Approx. 7 kg *5 *5 When four plug-in units (i.e., LT 443D-HD, LT 443D-SD, LT 443D-BL, LT 443D-GL) are installed. 16 3/4 (W) x 1 3/4 (H) x 22 (D) in., 15.4 lbs
Power cord....................................................1
Cover/Inlet stopper .......................................1
Rack Support (right and Left) .......................1
Screw (for rack support)...............................4
Rubber Feet..................................................5
Logo Mark Software CD-R............................1
Instruction manual ........................................1
LT 443D SPECIFICATIONS
Page 39
LT 443D-GLA GENLOCK UNIT
39
This unit provides genlock capability to lock the LT 443D mainframe with the external reference signal, and three independent black signal genera­tors. The NTSC/PAL black burst signals, principal 20 types of HDTV analog tri­level sync signal formats, and 525p/625p analog sync signals can be used as an external reference signal. The following black burst signal formats can be selected. For NTSC/PAL system, black burst signal with field reference pulse is pro­vided. For NTSC system, black burst with 10-field sequence identification conforming to the SMPTE 318M standards is provided. The instrument continues operation since the flywheel mode is provided even if the external reference signal is accidentally removed in genlock mode. By logging the genlock status, the time can be obtained when the external reference signal is removed. The log information can be stored on
the CF CARD. The genlock timing can be adjusted for the entire color frame range when the NTSC/PAL black burst signal is applied; entire frame range when the HDTV analog tri-level sync signal is applied. Three black burst signal output systems with selectable formats are avail­able as follows: For NTSC/PAL system, standard black burst signal and black burst signal with field reference pulse are provided. For NTSC system, 10-field black burst signal with ID conforming to the SMPTE 318M standards, 525p/625p analog sync signal, and HDTV analog tri-level sync signal are provided. The format and output signal timing of each output can be respectively set. The black signal timing can be adjusted for the entire color frame range when the NTSC/PAL black burst signal is applied; entire frame range when the HDTV analog tri-level sync signal is applied.
The LT 443D-HD HD-SDI Unit adds the 14 format HD­SDI signal output capability to the LT 443D mainframe. Various functions (e.g., ID character, simple motion pictures, embedded audio, NATURAL picture pattern*) are provided. *The NATURAL picture function is only usable when the LT 443D-70 Option is installed in the mainframe.
Output
• HD-SDI Video Output
Specifications
• Specifications
SDI Characteristics
• Bit Rate
• Output Amplitude
• Overshoot
• Rise and Fall Time
• Return Loss
Function
• Applicable Format
• Test Patterns
1 system, 2 outputs (75 , BNC)
Conforms to SMPTE 240M(Except for Return Loss) /274M/296M standards
1.485 Gbps, 1.485/1.001 Gbps 800 mVp-p ±10%
10 %270 ps (20 % to 80 %)15 dB (5 MHz to 742.5 MHz)10 dB (742.5 MHz to 1.485 GHz)
1035i/60, 1035i/59.94, 1080i/60, 1080i/59.94, 1080i/50, 1080p/30, 1080p/29.97, 1080p/25, 1080p/24, 1080p/23.98, 1080PsF/24, 1080PsF/23.98, 720p/60, 720p/59.94 The following formats will be supported: 720p/29.97, 720p/24, 720p/23.98, 720p/50, 720p/30, 720p/25 COLOR BAR 100 %, COLOR BAR 75 %, MULTIFOR­MAT COLOR BAR (ARIB STD-B28) FLAT FIELD 100 %,
• Variable Timing Variable Range Variable In V
H
Simple Motion Picture Mode (Scroll)
Direction Speed
(Range, Resolution) Field Frame Interlace V Interlace H Common
• ID Character
• Embedded Audio Number of Channels Embedded
Sampling Frequency Resolution Preemphasis Frame Number Frequency
Level
FLAT FIELD 50 %, FLAT FIELD 0 %, LINE SWEEP 100 %, MULTI BURST 100 %, BOWTIE 100 %, RAMP, SHAL­LOW RAMP, 10 STEP, PULSE & BAR, CHECK FIELD, RED RASTER 100 %, CROSS & DOT, MONOSCOPE
Entire frame range Line steps Clock steps (74.25 MHz or 74.25/1.001 MHz)
8 directions (vertical, horizontal, diagonal)
Variable in field steps 0 to 256 lines in 2 line steps 0 to 256 dots in 4 dot steps ID characters can be displayed at the arbitrary posi­tion on the screen.
8 channels (4 channels x 2 groups) Each group can be set ON/OFF 48 kHz (sync to video signal) 20 bits, 24 bits, selectable OFF, 50/15 µs, CCITT, selectable (CS bit is only selected.) None 50, 100, 150, 200, 250, 300, 400, 500, 600, 750, 800, 1.0 k, 1.2 k, 1.5 k, 1.6 k, 2.0 k, 2.4 k, 3.0 k,
3.2 k, 4.0 k, 4.8 k, 5.0 k, 6.0 k, 8.0 k, 9.6 k, 10 k, 12 k, 15 k, 16 k, 20 kHz, silence
-60 to 0 dBFS (settable in 1 dB steps) *Frequency, level, and audio click can be set to each channel. *When the CHECK FIELD pattern is selected, no audio signal is embedded.
Sync Level (into 75 Ω)
• HDTV
• 525p
• 625p
• NTSC
• PAL
Rise and fall times
• HDTV
• 525p
• 625p
• NTSC
• PAL
Horizontal Sync Width
• 1125-Line Format
• 750-Line Format
• 525p
• 625p
• NTSC/PAL
Vertical Sync Width Output Connector Number of Outputs Timing Variable Range
• H-PHASE
• V-PHASE
• F-PHASE
N14/SMPTE RP-154/SMPTE 170M/SMPTE 318M standards PAL black burst signal conforming to ITU-R BT. 470­6 standards
Positive polarity: 300 mV ±6 mV Negative polarity: -300 mV ±6 mV
-300 mV ±6 mV
-300 mV ±6 mV 40 IRE ±1 IRE
-300 mV ±6 mV
54 ns ±20 ns 70 ns ±10 ns 100 ns ±10 ns 140 ns ±10 ns 200 ns ±10 ns
Positive polarity: 593 ns ±40 ns Negative polarity: 593 ns ±40 ns Positive polarity: 539 ns ±40 ns Negative polarity: 539 ns ±40 ns
2.35 µs ±0.05 µs
2.35 µs ±0.1 µs
4.7 µs ±0.1 µs 5H (HDTV) / 6H (525p) / 5H (625p) / 3H (NTSC) / 2.5H (PAL) BNC 1 each
Up to ±1 line-1 dot Up to ±1 frame-1 line Up to ±5 frames
(depends on the input signal format.)
Genlock Function
Loop-Through Input
Input Configuration Return Loss Reference Input Signal
Reference Input Signal Level
• HDTV
• 525p/625p
• NTSC
• PAL
Operation Modes
Genlock Timing Variable Range
• H-PHASE (FINE)
• H-PHASE (COARSE)
• V-PHASE
• F-PHASE
Analog Sync Signal Output
BLACK 1/BLACK 2/BLACK 3 Output Format
BNC connector, 75 loop-through30 dB (0.3 MHz to 30 MHz)
HDTV tri-level sync signal conforming to SMPTE 240M/274M/296M standards 525p/625p analog sync signal conforming to SMPTE 293M/ITU-R BT 1358 standards NTSC black burst signal conforming to EBU N14/SMPTE RP-154/SMPTE 170M/SMPTE 318M standards PAL black burst signal conforming to ITU-R BT. 470-6 standards
Positive polarity: 300 mV Negative polarity: -300 mV
-300 mV
-286 mV
-300 mV AUTO and MANUAL modes are provided for select­ing INT or EXT mode.
Fine adjustment between the H-PHASE (COARSE) steps. ±1/2 line with respect to the input signal ±1 frame with respect to the input signal Up to ±5 frames with respect to the input signal. (Variable range depends on the input signal format.)
HDTV tri-level sync signal conforming to SMPTE 240M/274M/296M standards 525p/625p analog sync signal conforming to SMPTE 293M/ITU-R BT 1358 standards NTSC black burst signal conforming to EBU
Plug-In Unit For LT 443D
LT 443D-HD HD-SDI UNIT/LT 443D-HDB (HD-SDI Out x 2, HD-SDI Black Out x 2) UNIT
Plug-In Unit For LT 443D
Page 40
40
Output
• SD-SDI Video Output
Specifications
• Specifications
SDI Characteristics
• Bit Rate
• Output Amplitude
• Overshoot
• Rise and Fall Time
• Return Loss
Function
• Applicable Format
• Test Patterns
1 system, 2 outputs (75 , BNC)
Conforms to ITU-R BT. 601, SMPTE 125M standards Conforms to ITU-R BT. 656, SMPTE 259M standards
270 Mbps 800 mVp-p ±10 % 10 %
0.4 to 1.5 ns (20 % to 80 %) 15 dB (5 MHz to 270 MHz)
525i/59.94-270 MHz, 625i/50-270 MHz COLOR BAR 100%, COLOR BAR 75%, EBU COLOR BAR, BBC COLOR BAR, SMPTE COLOR BAR, RAMP & COLOR, FLAT FIELD 100%, FLAT FIELD 50%, FLAT FIELD 0%, FIELD ID, CROSSHATCH, LINE SWEEP 100%, LINE SWEEP 60%, MULTIBURST 100%, MULTI­BURST 60%, OVER SIZE RAMP, DIGITAL LIMIT RAMP, SHALLOW RAMP, 10 STEP, CHECK FIELD, MONOSCOPE, BOWTIE 100%, PULSE & BAR, RED RASTER, MULTIPULSE
• Variable Timing Variable Range Variable In V
H
Simple Motion Picture Mode (Scroll)
Direction Speed
(Range, Resolution) Field Frame V H
• ID Characters Number of Characters Size
• Embedded Audio Number of Channels Embedded
Sampling Frequency Resolution Preemphasis Frame Number Frequency
Level
Entire frame range Line steps Clock steps (27 MHz)
8 directions (vertical, horizontal, diagonal)
Variable in field steps 0 to 256 lines in 2 line steps 0 to 256 dots in 4 dot steps
Up to 20 32 x 32 dots, 64 x 64 dots, selectable
8 channels (4 channels x 2 groups) Each group can be set ON/OFF respectively. 48 kHz (sync to video signal) 20 bits, 24 bits, selectable OFF, 50/15 µs, CCITT, selectable(CS bit is only selected.) ON/OFF, selectable 50, 100, 150, 200, 250, 300, 400, 500, 600, 750, 800,
1.0 k, 1.2 k, 1.5 k, 1.6 k, 2.0 k, 2.4 k, 3.0 k, 3.2 k,
4.0 k, 4.8 k, 5.0 k, 6.0 k, 8.0 k, 9.6 k, 10 k, 12 k, 15 k, 16 k, 20 kHz, silence
-60 to 0 dBFS (settable in 1 dB steps) *Frequency, level, and audio click can be set to each channel. *When the CHECK FIELD pattern is selected, no audio signal is embedded.
Function
• Sampling Frequency
• Frequency
• Level
48 kHz (Sync to video signal) 50, 100, 150, 200, 250, 300, 400, 500, 600, 750, 800,
1.0 k, 1.2 k, 1.5 k, 1.6 k, 2.0 k, 2.4 k, 3.0 k, 3.2 k,
4.0 k, 4.8 k, 5.0 k, 6.0 k, 8.0 k, 9.6 k, 10 k, 12 k, 15 k, 16 k, 20 kHz, silence
-40 to 4 dBm (settable in 1 dBm steps)
Output
• Number of Outputs
• Output Impedance
• Output Amplitude
Output Amplitude Accuracy
Output Amplitude Flatness
• Output Connector
2 600 , balanced
0.775 Vrms (into 600 at 0 dBm) ±0.5 dB (at 1 kHz) ±0.5 dB (1 kHz ref.) XLR-3P x 2
The LT 443D-SD SD-SDI Unit adds the 525/625 line format SD-SDI signal (4:2:2 component signal) output capability to the LT 443D mainframe. Various functions (e.g., ID charac­ter, simple motion pictures, embedded audio, NATURAL picture pattern*) are provided. *1: The NATURAL picture function is only usable when the LT 443D-70 Option is installed in the mainframe.
Installing the LT 443D-AA Analog Audio Unit in the LT 443D mainframe can output analog audio signal (two systems). Output characteristics (e.g., output level, frequency) can be independently set for each output system. The sound sampling frequency is synchronized with the video signal of plug-in unit installed in the mainframe.
Analog Sync Signal Output
BLACK 1, 2/BLACK 3, 4/BLACK 5, 6 Format
Sync Level (into 75 Ω)
• HDTV
• 525p
• 625p
• NTSC
• PAL
Rise and fall times
• HDTV
• 525p
HDTV tri-level sync signal conforming to SMPTE 240M/274M/296M standards 525p/625p analog sync signal conforming to SMPTE 293M/ITU-R BT 1358 standards NTSC black burst signal conforming to SMPTE RP­154/SMPTE 170M/SMPTE 318M standards PAL black burst signal conforming to ITU-R BT. 470­6 standards
Positive polarity: 300 mV ±6 mV Negative polarity: -300 mV ±6 mV
-300 mV ±6 mV
-300 mV ±6 mV 40 IRE ±1 IRE
-300 mV ±6 mV
54 ns ±20 ns 70 ns ±10 ns
• 625p
• NTSC
• PAL
Horizontal Sync Width
• 1125-Line
• 750-Line
• 525p
• 625p
• NTSC/PAL
Vertical Sync Width Output Connector Number of Outputs Timing Variable Range
• H-PHASE
• V-PHASE
• F-PHASE
100 ns ±10 ns 140 ns ±10 ns 200 ns ±10 ns
Positive polarity: 593 ns ±40 ns Negative polarity: 593 ns ±40 ns Positive polarity: 539 ns ±40 ns Negative polarity: 539 ns ±40 ns
2.35 µs ±0.05 µs
2.35 µs ±0.05 µs
4.7 µs ±0.1 µs 5H (HDTV) / 6 H (525p) / 5H (625p) / 3H (NTSC) / 2.5H (PAL) BNC (BLACK 1, 2/BLACK 3, 4/BLACK 5, 6) 2 each
Up to ±1 line-1 dot Up to ±1 frame-1 line Up to ±5 frames
(depends on the input signal format.)
The LT 443D-BL Analog Black Signal Unit adds the 20 HDTV format analog tri-level sync signal, 525p/625p analog sync signals, and NTSC/PAL black burst signals output capability to the LT 443D main­frame. Three independent output systems (six outputs, two outputs per sys­tem) are provided to output multiformat black sync signal. The format and output signal timing can be respectively set each output.
The ten-field black signal with ID conforming to the SMPTE 318M standards is also available. The entire range of timing can be set for the 525p/625p analog sync signals and NTSC/PAL black burst signals in 54 MHz clock steps. The entire range of timing can also be set for the HDTV analog tri­level sync signal in 74.25 MHz or 74.25/1.001 MHz clock steps.
LT 443D-BL ANALOG BLACK UNIT
LT 443D-SD SD-SDI UNIT/LT 443D-SDB
(SD-SDI Out x 2, SD-SDI Black Out x 2)
UNIT
LT 443D-AA ANALOG AUDIO UNIT
Plug-In Unit For LT 443D
Plug-In Unit For LT 443D
Plug-In Unit For LT 443D
Page 41
41
Output
AES/EBU Digital Audio Output
Number of Outputs Output Amplitude Output Connector
Silence Signal (DARS grade 2) Output
Number of Outputs Output Amplitude Output Connector
• 48 kHz Word Clock Number of Outputs Output Amplitude Output Connector
Signal Specifications
• Specifications
4 (2-channel output) 1 Vp-p ±0.1 V (into 75 Ω) BNC
1 (2-channel output) 1 Vp-p ±0.1 V (into 75 Ω) BNC
1 1 Vp-p ±0.1 V (into 75 ), 5 V CMOS, selectable BNC
ANSI S4.40 (AES3-1992), AES 11-1997 SMPTE 276M, AES-3id-2001
Function
• Sampling Frequency
• Resolution
• Preemphasis
• Frequency
• Level
• Audio Click
• Output ON/OFF
• Timing Variable Range
48 kHz (sync to video signal) 20 bits, 24 bits, selectable OFF, 50/15 µs, CCITT, selectable (CS bit can only be selected.) 50, 100, 150, 200, 250, 300, 400, 500, 600, 750, 800,
1.0 k, 1.2 k, 1.5 k, 1.6 k, 2.0 k, 2.4 k, 3.0 k, 3.2 k,
4.0 k, 4.8 k, 5.0 k, 6.0 k, 8.0 k, 9.6 k, 10 k, 12 k, 15 k, 16 k, 20 kHz, silence
-60 to 0 dBFS (settable in 1 dB steps) 1, 2, 3, 4 sec, none Selectable
±1 AES/EBU frame Settable in 512 fs (24.576 MHz) steps *The timing can be varied with respect to the Video Unit installed in the LT 443D mainframe. The settings are common to the digital audio, silence and word clock signals. *Frequency, level, and audio click can be set to each channel. Other items (except timing) can be respectively set to the 2-channel output.
Installing the LT 443D-DA Digital Audio Unit in the LT 443D mainframe can output AES/EBU digital audio signals (four systems), silence signals (one system), and 48 kHz word clock signals. The AES/EBU signal characteristics (e.g., output level, fre­quency) can be independently set for each output system. The sampling frequency is synchronized with the video sig­nal of plug-in unit installed in the mainframe.
Test Signal Output
• Format
• Pattern
• NATURAL Picture *5
• APL MODE
Time Interval
• ID Charactor Number of Characters Size Display Position Blinking
NTSC, NTSC+REFERENCE *2, NTSC+ID *3, NTSC+REF­ERENCE+ID *2 *3, NTSC+SETUP, NTSC+SETUP+REF *2, NTSC+SETUP+ID *3, NTSC+SETUP+REF+ID *2 *3, PAL *4, PAL+REFERENCE *4 *2
*2 REFERENCE and REF denote Field Reference. *3 ID denotes 10 field ID. *4
The 25-Hz offset subcarrier is used for the PAL system. COLOR BAR 100%, COLOR BAR 75%, EBU COLOR BAR, BBC COLOR BAR, SMPTE COLOR BAR, FLAT FIELD 100%, FLAT FIELD 50%, FLAT FIELD 0%, CROSSHATCH 1, CROSSHATCH 2, LINE SWEEP 100%, LINE SWEEP 60%, MULTIBURST 100%, MULTIBURST 60%, SHAL­LOW RAMP, 10 STEP, MOD 10 STEP, RAMP, MOD RAMP, MONOSCOPE, RED RASTER, WINDOW, PULSE & BAR Up to five screens of 24-bit full color BMP file can be simultaneously switched.
APL OFF, APL HIGH, APL LOW, APL(BOUNCE), BOUNCE APL (BOUNCE) is switched at a preset time interval for APL HIGH and APL LOW. BOUNCE is switched at a preset time interval for FLAT FIELD 100 % and FLAT FIELD 0 %. 1 to 20 seconds (settable in one second steps)
Up to 20 32 x 32 dots, 64 x64 dots, selectable Arbitrary position on the screen. OFF, 1 to 10 seconds (settable in one second steps)
Simple Motion Picture Function
Direction Speed
• Timing Variable H-PHASE V-PHASE F-PHASE
• Number of Outputs
Black Signal Output
• format
• Output Signal
• Format
• Timing Variable H-PHASE V-PHASE F-PHASE
• Number of Outputs
• Signal Level
Horizontal Drive Pluse Output
• Format
• Signal Level
• Signal Polarity
• Timing Variable H-PHASE
• Number of Outputs
Vertical Drive Pluse Output
• Format
• Signal Level
• Signal Polarity
• Timing Variable V-PHASE
• Number of Outputs
8 directions (up, down, left, right, and combinations) H: 0 to 256 dots in 4 dot steps V: 0 to 256 lines in 2 line steps (Pattern can be scrolled in field time steps.) *5 The Option LT 443D-70 should be installed in the mainframe to enable this function. The timing of OUTPUT 1 and 2 can be varied simultaneously. Up to ±1 line-1 dot Up to ±1 frame-1 line NTSC:Up to ±5 frames PAL: UP to ±2 frames 2
Depends on the test signal format. (Supports the field Reference and 10 field ID) Analog black burst The timing of OUTPUT 1 and 2 can be varied simultaneously.
Up to ±1 line-1 dot Up to ±1 frame-1 line NTSC:Up to ±5 frames PAL: UP to ±2 frames 2 Systems (one each) 1 Vp-p (into 75 Ω)
Depends on the test signal format. 2 Vp-p (into 75 Ω) Negative
Up to ±1 line-1 dot 1
Depends on the test signal format. 2 Vp-p (into 75 Ω) Negative
Up to ±1 frame-1 line 1
The LT 443D-CS Analog Composite Unit adds the NTSC/PAL analog composite signal output capability to the LT 443D mainframe. Various functions (e.g., ID character, simple motion pictures, embedded audio, NATURAL picture pattern *1) are provided. *1: The NATURAL picture function is only usable when the Option LT 443D-70 is installed in the mainframe.
LT 443D-DA DIGITAL AUDIO UNIT
LT 443D-CS ANALOG COMPOSITE UNIT
Plug-In Unit For LT 443D
Plug-In Unit For LT 443D
Page 42
42
MULTI FORMAT VIDEO GENERATOR
Applicable to both HD-SDI and SD-SDI systems, 1U half-rack size
The compact, 1U half-rack sized, LT 4400 Multiformat Video Generator is applicable to both HD-SDI and SD-SDI systems. The various output capabilities are provided: color bar, SDI check field test pattern, ID characters, logomark in QVGA size, safety-area marker, superimposing embedded audio, genlock mode to synchronize external reference signal, and three independent analog black signal systems.
Genlock mode
This instrument can be locked by a NTSC/PAL black burst or HDTV tri-level sync signals for variable timing. The NTSC/PAL black burst signals with field reference pulse signal, and NTSC/PAL black burst signal with 10-field ID are also applicable.
Stay-in sync function
This function ensures the stable operation in genlock mode even when the external reference signal is accidentally intermitent.
Analog black signal output
Three independent analog black signal output systems are provided. The black burst signal with the same format as the SDI output, or HDTV tri-level sync signal with the same format of clock frequency can be selected for variable tim­ing. The NTSC/PAL black burst signals with field reference pulse signal, and NTSC black burst signal with 10-field ID are also applicable.
Pattern scroll (Simple motion picture mode)
The simple motion picture mode is provided to scroll the pattern.
Word clock output
The 48 kHz word clock output is provided to synchronize the audio signal.
Applicable to SNMP
The network system can easily be constructed since this instrument supports SNMP. (Not available currently)
FEATURES
Applicable to both HD-SDI and SD-SDI systems
Applicable to both HDTV (18 types of HDTV formats) and SDTV (525i/59.94, 625i/50) systems. The HDTV or SDTV can be selected.
Superimposing ID characters
The ID characters can be superimposed at the arbitrary position on the screen. The character blinks to indicate the freeze status.
Superimposing logomark
A logomark up to 320 (pixel) x 240 (line) in QVGA size can be superimposed at an arbitrary position on the screen. The logomark is converted from the bit map to four-grade monochrome data.
Safety-area marker
The 90 % and 80 % safety-area markers can be superim­posed on the screen. The 4:3 aspect-ratio marker can also be superimposed in HDTV format.
Superimposing embedded audio
The 16 channels of embedded audio signals (4 channels x 4 groups) can be superimposed. The frequency and level can be respectively set for each channel.
LT 4400
OPTION
OP70:FULL SIZE LOGO Option
Applicable to the LOGO MARK of a full screen The Logo Mark of full screen size (up to 1920 x 1080 pixels) can be displayed.
Page 43
43
LT 4400 SPECIFICATIONS
SDI Output
Number of Outputs Conform To
HDTV SDTV
Applicable Format
HDTV
SDTV
Timing Variable
Variable Range Resolution
Test Patterns
HDTV
SDTV
Safety Area Marker
HDTV
SDTV
ID Characters
Number of Characters Size
HDTV
SDTV Display Position Freeze Confirmation Display
Logo Mark
Logo Mark Data Maximum Size Display Position Display Level Display Method File Format
Before Conversion
After Conversion Conversion Color Matrix
Conversion Method Transferring the Logo Mark Data
Pattern Scroll (Simple Motion Picture Mode)
Direction
Speed (Range, Resolution)
Field and Frame
Interlace Others
V Interlace
Others
H Common
Embedded Audio
Number of Channels Embedded
Sampling Frequency Resolution Preemphasis Frame Number Frequency Level
Audio Click
Genlock Function
Reference Input Signal
Input Configuration Input Signal
NTSC black burst signal
PAL black burst signal
HDTV tri-level sync signal Sync Level
NTSC black burst signal
PAL black burst signal
HDTV tri-level sync signal Maximum Input Level Operating Input Level Range External Lock Range Jitter
Burst Lock Mode
Sync Lock Mode
Operation Modes
INTERNAL
1 system, 2 outputs (75 , BNC) HD-SDI/SD-SDI, selectable
SMPTE 274M, SMPTE 296M, SMPTE 292M (except return loss) ITU-R BT 601, SMPTE 125M ITU-R BT 656, SMPTE 259M
1080i/60, 1080i/59.94, 1080i/50, 1080p/30, 1080p/29.97, 1080p/25, 1080p/24, 1080p/23.98, 1080PsF/24, 1080PsF/23.98, 720p/60, 720p/59.94, 720p/50, 720p/30, 720p/29.97, 720p/25, 720p/24, 720p/23.98 525i/59.94-270 MHz, 625i/50-270 MHz
Entire frame range V: Settable in line steps H: Settable in clock steps (74.25 MHz, 74.25/1.001 MHz, 27 MHz)
COLOR BAR 100 %, COLOR BAR 75 %, MULTIFOR­MAT COLOR BAR (ARIB STD-B28:75 % White, 100 % White, and + I signal, selectable), CHECK FIELD COLOR BAR 100 % (applicable to both 525i/59.94, 625i/50), COLOR BAR 75 %, SMPTE COLOR BAR (applicable to 525i/59.94), EBU COLOR BAR/BBC COLOR BAR (applicable to 625i/50), CHECK FIELD (applicable to both 525i/59.94, 625i/50)
Action safety area (90 %), Title safety area (80 %) 4:3 aspect ratio Selectable ON/OFF individually Action safety area (90 %), Title safety area (80 %) Selectable ON/OFF individually
Up to 20 characters
32x32/64x64/128x128 dots selectable 32x32/64x64 dots selectable Displays at an arbitrary position on the screen. Blinking OFF, 1 to 10 seconds
4-level monochrome data between 0 and 3 320(dot) x 240(line) (QVGA size) Displays at an arbitrary position on the screen Set arbitrary levels for levels 0 to 3 Simultaneous display with the ID character
24-bit full-color bitmap data (.bmp) format LT 4400/LT 443D dedicated (.lg) format Y = 0.212*R + 0.701*G + 0.087*B Converts 256-level monochrome data(Y) to four levels (level 0 to 3) using arbitrary threshold values. Converted using the logo mark conversion application. Saves the data to a commercially sold Compact Flash card and inserts it to the LT 4400. *The data loaded from CF card to the LT 4400 can­not be held when the power is turned OFF.
8 directions (vertical, horizontal, diagonal)
Variable in field steps Variable in frame steps 0 to 256 lines in 2 line steps 0 to 256 lines in 1 line steps 0 to 256 dots in 4 line steps
16 Channels (4ch x 4group). Each group can be set ON/OFF 48 kHz (sync to video signal) 20 bits, 24 bits, selectable OFF, 50/15 ms, CCITT, selectable (CS bit can only be selected) ON, OFF, selectable 400 Hz /800 Hz /1 kHz, selectable (sets to each channel) Can be selected including silence (sets to each channel)
-60 to 0 dBFS (settable in 1 dBFS steps) 1 sec/2 sec/3 sec/4 sec/OFF (sets to each channel)
* When the CHECK FIELD pattern is selected, no
audio signal is embedded.
* In the SDTV format, resolution becomes 20 bits
when the 16ch is output.
BNC (75 , loop through)
EBU N14/SMPTE RP154/SMPTE 170M/SMPTE 318M ITU-R BT.470-6 SMPTE 274M, SMPTE 296M
-286 mV
-300 mV ±300 mV ± 4.5 V (DC + peak AC) ±6 dB ± 10 ppm
0.5 °1 ns
Internal reference signal is used for operation. (INT mode)
AUTO (GO INTERNAL)
The EXT is automatically selected when the external reference signal is applied to the GENLOCK input. The INT mode is automatically selected when the exter­nal reference signal is removed.
MANUAL (GO INT)
The EXT mode is automatically selected when the external reference signal with the same format specified to the GENLOCK input is applied after power is turned on. The INT mode is automatically selected when no external reference signal is applied to the GENLOCK input or signal format does not match the specified format.
AUTO (STAYinSYNC)
The EXT mode is automatically selected when the external reference signal is applied to the GENLOCK input after power is turned on. If the external reference signal is accidentally removed during operation, the instrument continues operation under the conditions immediately before the sig­nal is removed since STAYinSYNC mode is provided. After the external reference signal is recovered, the system is automatically locked.
MANUAL (STAYinSYNC)
The EXT mode is automatically selected when the external reference signal with the same format specified to the GENLOCK input is applied after power is turned on. If the external reference signal is accidentally removed during operation, the instrument continues operation under the conditions immediately before the signal is removed since STAYinSYNC mode is provided. The STAYinSYNC mode will be held until the reset operation is performed via the front panel even after the external reference signal is recovered.
Genlock Timing
Variable Range
NTSC black burst signal PAL black burst signal HDTV tri-level sync signal
Resolution
H V F
Reference Point
(at the time of the
black burst input)
NTSC
PAL
Analog Sync Signal Output
Format
NTSC black burst signal HDTV tri-level sync
Output Signal
Number of Outputs
Setting Output Format
Output Connector
Output Impedance Output Connector
Output Timing
Setting Variable Range
NTSC black burst signal PAL black burst signal HDTV tri-level sync
Setting Resolution
NTSC black burst signal HDTV tri-level sync
Word Clock Output
Frequency Output Impedance Output Amplitude Output Connector Number of Outputs Timing Variable
Variable Range Setting Resolution
Memory Card Slot
Function Ethernet Connector
Type Function
LCD Panel
Number of Characters
Environmental Conditions
Operating Temperature Range Operating Humidity Range Spec-Guaranteed Temperature Spec-Guaranteed Humidity Operating Environment Operating Altitude Overvoltage Category Pollution Degree
Power Requirements Dimensions and Weight
Accessories
±5 frames ±2 frames 1 frame (entire frame range)
0.0741 µs steps (13.5 MHz clock steps) 1 line steps 1 frame steps
The phase coincident point of line 4 of the NTSC and line 1 of the HDTV The phase coincident point of line 1 of the PAL and line 1 of the HDTV
EBU N14, SMPTE RP154, SMPTE 170M, SMPTE 318M SMPTE 274M, SMPTE 296M
6 Outputs (three output systems which equip with two connectors each) Settable
75 BNC
Three systems can be set individually.
±5 frames ±2 frames 1 frame (entire frame range)
0.0185 µs steps (54 MHz in clock steps)
0.0135 µs steps (74.25/1.001 MHz in clock steps, or 74.25 MHz in clock steps)
48 kHz 75 Ω unbalanced ("1 Vp-p" output) 1 Vp-p ± 0.1 V (into 75 ), or 5 V CMOS, selectable BNC 1
±1 AES/EBU frame 512 fs (24.576 MHz) steps
Storing/reading preset data Reading logo data
10BASE-T/100BASE-TX, auto switching Transferring operation status (e.g., genlock status) Remote control (e.g., pattern switching) SNMP supported (to be supported in the future)
20 characters x 2 lines can be displayed (w/backlight)
0 to 40 °C 85 % RH (without condensation) 10 to 30 °C 85 % RH (without condensation) Indoor use Up to 2000 m I 2
DC12 V (10 to 18 V) 20 W 213(W) x 44(H) x 400(D) mm (excluding projections), 1.8 kg
8 3/8(W) x 1 3/4(H) x 15 4/5(D) in., 4 lbs
AC adapter.............................................................1
Instruction manual..................................................1
Page 44
44
SPECIFICATIONS
AUTO CHANGEOVER
LT 444/LT 4440
The LT 444/LT 4440 is a changeover unit that automatically switches the signal from the primary signal to the backup signal when problems are detected in the primary signal. If a switch occurs from the primary signal to the backup signal, the LT 444/LT 4440 indicates the channel that caused the problem on the LED front panel.
The LT 444/LT 4440 is a changeover unit that switches to the backup system when failures occur.
FEATURES
Input/Output
Provides 11 channels (a single channel consists of PRIMA­RY input, BACKUP input, and OUTPUT output) on a single LT 444.
• Delay for Starting the Monitor
The delay for starting the error monitor at power up can be set to FAST or SLOW depending on the rise time of the sys­tem signal source being connected.
• Determination Criteria of the Signal Level
The internal preset switch allows level detection switching among SD-SDI, AES/EBU digital audio, NTSC or PAL analog black burst, HD analog tri-level sync, HD-SDI(only supported on channels 1 to 6), and other signals.
• Error Display
When a signal level error is detected, the LT 444 illuminates the error LED on the front panel as well as the LED panel that indicates the channel causing the problem. This feature allows quick investigation of the problem.
• Dimension
Inputs
PRIMARY inputs
BACKUP input
Outputs
OUTPUT outputs
Input/Output Characteristics (CH1 to CH11)
Return Loss
Input Signal Type
Signal Type
Determination Criteria of the Signal Level
Detection Level
Error Display
Total Error LED
Error Channel LED
Panel Key Lock
Time to Key Lock
External Control (REMOTE) Connector
Application Connector Type
Dimensions and Weight
Accessories
1 input each for 11 channels (75 BNC connector) 1 input each for 11 channels (75 BNC connector)
1 output each for 11 channels (75 BNC connector)
30 dB 0 to 10 MHz 15 dB 10 MHz to 750 MHz 10 dB 750 MHz to 1.5 GHz
Set the type of input signal applied to the LT 444 using the internal dip switch. HD-SDI (CH1 to CH6 only) SD-SDI (270 Mb/s) SD-SDI (143 Mb/s) AES/EBU digital audio Tri-level sync signal NTSC black burst PAL black burst
Detects an error when the amplitude of the input signal drops by 2 to 5 dB from the defined level and makes the switch. The detection level can be set to LOW or HIGH for each signal type.
Notifies errors by illuminating the error LED on the panel. Detects the channel causing the error and shows the channel by illuminating the corresponding LED.
The key lock is automatically enabled when key operation is not detected for 60 s.
For external remote control. 9-pin Dsub connector
426 (W) x 44 (H) x 560 (D) mm(LT 444) 426 (W) x 44 (H) x 400 (D) mm(LT 4440) (excluding protrusions), 4 kg 16 3/4 (W) x 1 3/4 (H) x 22 (D) in.(LT 444) 16 3/4 (W) x 1 3/4 (H) x 15 4/5 (D) in.(LT 4440) (excluding protrusions), 8.8 lbs
Rack supports
.......................................................
2
Rack support attachment screws
..........................
4
Power cord
............................................................
1
Instruction manual
.................................................
1
•LT 444 is a Deeper Cabinet
(LT 4440)
Page 45
45
The LT 4440 can be configured in the system with the LT4400
LT 4440 is a Short Cabinet
REAR PANEL
The LT 444 can be configured in the system with the LT443D
LT 444 is a Deeper Cabinet
The photo is LT 444
400 mm
15 4/5 in.
560 mm 22 in.
Dimension
Page 46
46
410BB SPECIFICATIONS
NTSC SYNC GENERATOR
410BB
The 410BB is an NTSC Sync Generator that provides sync generator signals for other video equipment.
410BB REAR PANEL
Provides six black burst outputs
FEATURES
Provides six black outputs
Provides composite sync and subcarrier outputs
Provides SMPTE color bars output
Digital waveform generation provides highly accurate and stable signals.
Supplies two 1 kHz outputs of audio tone
The low-profile rackmount size easily fits into system configuration
Black Burst (1)
System and other System
Number of Scanning Lines Field Frequency Line Frequency Subcarrier Frequency Output Impedance Number of Outputs
(2)
Sync Signal and Color Burst Sync Signal
Amplitude Blanking Level Rise/Fall Times Horizontal Sync Pluse Width Vertical Sync Pluse Width Equalizing Pluse Width Vertical Serration Pluse Width Virtical Blanking Period
Color Burst
Amplitude Number of Cycles Rise/Fall Times SCH Phase
NTSC-M, conforms to SMPTE 170M standards 525, interlaced
59.94 Hz
15.73426 kHz
3.579545 MHz ±10 Hz 75 6
286 ±14.3 mV 0 ±20 mV 140 ±20 ns
4.7 µs±100 ns 3H
2.3 µs±100 ns
4.7 µs±100 ns 20H +1.5 µs
286 ±14.3 mVp-p 9 300+200 ns, or 300-100 ns ±10 °
Composite Sync
Amplitude Output Impedance Polarity Timing Rise/Fall Times Number
of Outputs
Subcarrier
Amplitude Output Impedance Frequency Phase Number
of Outputs
SMPTE Color Bar
Specifications Full Amplitude Number of Outputs
Analog Audio Tone
Frequency Output Waveform Output Amplitude
Output Impedance Output Connector Number of Outputs
Others
Power Requirements
Size and Weight
Environmental Conditions Spec-Guaranteed Accuracy
Operating
Storage
Accessories
4±0.2 V into 75 75 Negative ±100 ns, compared with black burst 140±20 ns 1
2±0.2 Vp-p into 75 75
3.579545 MHz ±10 Hz ±10 °, compared with black burst 1
Conforms to SMPTE ECR1-1978 standards. 1 Vp-p ±20 mVp-p into 75 2
1 kHz±100 Hz Sine Wave 0±0.5 dBm, or 4±0.5 dBm, selectable by inter­nal switching 600 , balanced XLR type (3-pin), cannon 2
100, 120, 220, 240 VAC, 50/60 Hz, 20 Wmax. selectable by internal wiring 426 (W)×44 (H)×400 (D) mm, 6 kg 16 3/4(W)×1 3/4(H)×15 4/5(D) in., 13.3 lbs
Temperature:0 to 35 °C Humidity:85 % RH(without condensation) Temperature:0 to 40 °C Humidity:85 % RH(without condensation) Temperature:-10 to 50 °C
Rack support
1 set
Power cord
1
Instruction manual
1
Page 47
47
STEREO AUDIO MONITOR
5835
5835 REAR PANEL
Lissajous Display of Stereo Audio Signals Display with LED of Stereo Polarity Discrimination
The 5835 is a Stereo Audio Monitor that provides a lissajous pattern display of stereo audio signal on a CRT screen, enabling monitoring of the phase and level of the signal. The lissajous pattern display of the stereo signal is provided with the left and right axes inclined at 45 degrees, enabling a good visual presentation of audio effects such as broadening and apparent position. The 5835 features a stereo polarity discrimination function, a spot killer, and two Cannon-type inputs, making it ideal for use in not only program editing, but in checking of transmis­sion equipment as well. All this makes the 5835 a useful stereo audio monitor for broadcast, production, and record­ing studios or remote pickup applications as well.
FEATURES
•Parallel-connected male and female type XLR Cannon con­nectors are provided as standard for the balanced input configuration, enabling direct monitoring the lines required in broadcasting, production, and recording studios, or remote pickup applications.
•A stereo polarity discrimination function (patent pending) enables easy extraction and screen display of the audio sig­nal during editing of commercial tapes, and when monitor­ing the output waveform from a broadcast stereo signal, thereby greatly simplifying the task of checking the phase of the stereo signal.
•The 5835 is housed in an standard EIA half-rack size cabi­net, simplifying rack mounting and use in systems in com­bination with other equipment.
•A 150 mm post-acceleration (12 kV) type CRT ensures a bright display.
•The scale-illumination lamp can be replaced easily from the front panel.
•A spot killer blanks the trace with no signal applied to pre­vent burn-in of the CRT phosphor.
PAT. PEND.
5835 SPECIFICATIONS
CRT
Type Accelerating Potential Effective Display Area Scale Illumination Beam Rotator Graticule
X, Y-Axis
Input Connector
Input Impedance
Full Scale Input
Bandwidth Phase Difference Gain Adjustment
Stereo Polarity
Calibration
Z Axis
Spot-Killer
Front Panel Operation
Power Requirements
Dimensions and Weight
Accessories
Rectangular, 150 mm Post acceleration 12 kV 100 (H)×75 (V) mm Adjustable on the front panel Adjustable on the front panel External graticule with phase graticule
Two types input.L and R Rear cannon connector XLR-3-31, XLR-3-32 (First earth, second hot, third cold) Balanced input.more than 20 k, changing to 600 in internal At 775 mVrms input for L and R Full scale display in CRT (Y axis: L=R) (At CAL'D, RANGE 0 dB) 20 Hz to 20 kHz ±0.5 dB 20 Hz to 20 kHz ±1° RANGE (–20 dB, 0 dB, +10 dB) VARIABLE (approx, ±10 dB) An LED display lights yellow when stereo signal is in reversed phase (L-R). The LED hold time is a minimum of approximately 5 seconds. When the range is calibrated, a 1 kHz sine signal is input to the left and right channels enabling rotation adjustment and checking of gain.
The trace is blanked in the no-signal condition. POWER, INTEN, FOCUS, ILLUM, ROTAT, X-POSITION,
Y-POSITION, RANGE, VARIABLE, STEREO POLARITY 100, 120, 220, 240, VAC, 50/60 Hz Approx.
35 Wmax.
(set at the factory before shipping)
215 (W)×132 (H)×429 (D) mm, Approx. 7 kg 8 1/2 (W)×5 1/4 (H)×16 3/4 (D) in., Approx. 15.4 lbs
Power cord 1 Spare illumination lamp
2
Scale filter (for X-Y)
1
Screw, rack mounting (inch size)
2
Cover/Inlet stopper
1
Page 48
48
New Measurement Method
Overview of the 5 Bar Display
Overview of the SDI-EXT REF Phase Difference Display
■ 5BarDisplayEnablestheSimultaneousObservation ofDigitalBroadcastsandCompositeLevels
■ SDI-EXTREFPhaseDifferenceDisplay
■ SDI-EXTREFPhaseDifferenceDisplay
■ BarDisplayDetails
In the 5 bar display, video signal peak levels can be displayed instead of vectors. Five different bars are used to simultaneously display five different levels: luminance (Y), green (G), blue (B), red (R), and composite (COMP). The 5 bar display functions as a mode of the vector display. It is view­able as an alternate display under the vectorscope menu. The G, B, R, and COMP bars are converted from the SDI Y, C
B, and
C
R signals using matrix calculation.
100
0
100
0
100
0
100
0
-33
-40
120
133
135
GBR CMP
IRE
●Contentsofthe5BarDisplay
●Overview
The SDI-EXT REF phase difference display shows the phase differences between an SDI signal and an external sync signal (EXT REF).
●Features
Graphic and Numeric Displays of SDI and External Sync Signal (EXT REF) Phase Differences Traditionally, the most common SDI phase adjustment method was to determine the phase difference by switching between an internal and external sync signal and observing the waveform
●AfeaturethatshowsthephasedifferencesbetweenSDIandexternalsync(EXTREF)signals.
●You can readily determine the phase difference between an SDI and external sync (EXT REF) signal through graphic and numericphasedifferencerepresentations.YoucanalsodeterminethephasedifferencesbetweendifferentSDIsignalsbyset­tingthedifferenceforonesignaltozero.
●Youcanrecorduptoeightphasedifferences.Youcanquicklydeterminethephasedifferencesbetweenmultipleinputs.
shift. However, you can view phase differences and adjust phas­es more easily by using the SDI-EXT REF phase difference dis­play.
RelativeSDISignalPhaseDifferencesAreDisplayable
By setting a particular SDI-EXT REF phase difference to zero, you can display relative SDI signal phase differences.
StoreUptoEightDifferentPhaseDifferences
You can store up to eight different phase differences. This allows you to store up to eight different switcher SDI signal phases.
NumericDisplay
Thecurrentphase differences betweentheappliedSDIand EXTREFsignalsareindicated numericallyunder CURRENT PHASE.
PhaseDifferenceLog
Youcanstoreupto eight sets of measuredvalues.Thisisusefulin casessuchaswhenyouusea devicesuchasa switcher to changeinputsandmatchphases.
GraphicCenter
The V marker turns from white togreenwhenitisinthecenter. The H marker turns from white togreenwhenitiswithin±3 clocksofthecenter.
Y,G,B,R
100
0
●ContentsoftheComponentBarDisplay
CMP
IRE
0
100
120
133
135
-33
-40
●ContentsoftheCompositeBarDisplay
Y level bar
Positive peak
100 % color bar negative peak limit with 0 % setup.
Maximum negative modulation level
Luminance positive peak limit
Luminance negative peak limit
The blanking interval data does not appear in the bar levels.
Indicates the range between the positive and negative peak levels of Y + C (luminance + chromi­nance) in the SDI signal after it has been convert­ed to a composite signal.
100 % color bar negative peak limit with 0 % setup.
Reference level with
0.7 V set to 100 %
Reference level with 0 V set to 0 %
Negative peak
Indicates the range between the negative and positive peak levels
SDI Y signal level
Composite gamut bar
The combined luminance and chrominance signal level of the SDI signal after it has been converted to a composite signal.
GBR component gamut bars
The converted GBR levels of the SDI signal
Page 49
49
Page 50
50
OPTIONAL ACCESSORIES
Useful for incorporating video equipment system
LR 2404A
Cabinet
LR 2427B
Cabinet
LI 2306 (A set of 5 pcs.)
Illumination lamp
LI-2308 (LED)
Illumination lamp
without handle with handle
LI 2307 (A set of 2 pcs.)
Illumination lamp
LC 2126
Metal Cabinet
LH 2139
Viewing Hood
LR 2751-I
Rackmount adapter
A must for outdoor use
LC 2127
Tripod Mounting Plate
LP 1960
AC Adapter
For LV 5750For LV 5380 For LV 5750
For LV 5750
LC 2128
Front cover
For LV 5380, LV 5330,LT 4400, LV 5750,
LV 7700, LV 7720
126.5 mm.
4.98 in.
409 mm.
209.5 mm.
8.25 in.
16.10 in.
209.5 mm.
8.25 in.
126.5 mm.
4.98 in.
409 mm.
16.10 in.
Page 51
51
OPTIONAL ACCESSORIES
Dedicated Rack Mount Adapter (Sold Separately)
LR 2750-I
Rackmount adapter
LR 2700A-I
Rackmount adapter
EIA standard, inch size
LC 2125A Blank Panel
For LV 5750
190
482mm.
18.98in.
7.48in.
132mm.
5.20in.
mm.
LC 2125A Blank Panel
LR 2701 Rackmount Storage box
432mm.
130mm.
5.12in.
410mm.
16.14in.
482mm.
18.98in.
17.01in.
5.20in.
2.25in.
mm.
132mm.
57.2
Replacing with a lamp for 5222, 5850V, 5860V, etc. Replacing with a lamp for 5835
One unit of LV 7700 or LT 4400 fit in LR 2480 (Not for 2 units)
2 units of LV 7700/LT 4400 fit in LR 2477
LR 2701 is designed to be appropriated for the storage box LR 2700I/AI, Rackmount Adaptor
LV 5800, LV 5700A, LV 5152, 5212, 5222
LV 5800, LV 5152, 5212, 5222, LV 5700A,LV 5750, 5835, 5850V, 5860V, 5861V
Replacing with a lamp for 5850V, 5860V
LI 2306 LI 2307
LR 2480
LR 2477
LR 2701
LR 2404A LR 2427B
LR 2700A-I
LI 2308
Illumination lamp Illumination lamp
Rackmount adapter
Rackmount adapter
Rackmount Strage Box
LV 5380 only
LR 2751-I
Rackmount adapter
LV 5750 only
LR 2750-I
Rackmount adapter
Applicalle Model
Model Product Name
Cabinet (without handle) Cabinet (with handle)
Rackmount adapter
Illumination lamp (LED)
White CRT is standard.Description and specifications in this catalog are subject to change without previous notice.Caution: Use a cabinet with the specified model number. If you use a cabinet that has not been specified, ventilation will not take place properly, and damage to the instrument,
smoke emission, or fire may result.
LV 5700A, LV 5750
LC 2128
Front cover
LR 2700A-I, LR 2750-I
LR 2125A
Blank Panel
LR 2477
Rackmount adapter
LR 2480
Rackmount adapter
Page 52
2-6-33 Tsunashima-Higashi, Kohoku-ku, Yokohama 223-8505, Japan PHONE: 81-45-541-2123 FAX: 81-45-541-2823
LEADER ELECTRONICS CORP.
http://www.leader.co.jp
Jun.8,200909061KTS󱦯PrintedinJapan
SPECIFICATION CHANGES: LEADER ELECTRONICS CORP. reserves the right to discontinue the sale of instruments and/or change the speci ca-
tions of instruments at any time without responsibility for the incorporation of new features in the instruments already sold.
LEADER INSTRUMENTS CORP. (U.S.A.) PHONE:1-714-527-9300 LEADER INSTRUMENTS (H.K.) LTD. PHONE:852-2721-2503 LEADER ELECTRONICS CORP. BEIJING OFFICE PHONE:86-10-8511-8606/8607
LEADER ELECTRONICS CORP. SHANGHAI OFFICE PHONE:86-21-62756905, 62759629 LEADER ELECTRONICS EUROPEAN OFFICE PHONE:31-40-2565008
ACCESORIES For Video Test-Instruments
Also available following accessories
Dedicated Rack Mount Adapter (Sold separately)
LH 2140
LR 2751 I
LC 2129
LR 2481 For one Unit For two Units
LR 2752
LC 2130
LR 2478
for : LV 5380
The LV 5380 is sold
separatoly.
For : LV 5380
For:LR2751I
For:LV7330,LT4400
BatteryattachmentforLV5330andLV5380 ModelNo.:C-EB(XLR) ModelName: ExternalBatteryTerminal  (V-Mount:IDX)
CarryingCaseforLV5330 ModelNo.:i0812-2790 ModelName: CarryingcaseforLV5330
for:LR2752
For:LV7330,LT4400
for:LV5330
Handle
Rack Mount Adapter
Blank Panel (Sold Separatoly)
Rack Mount Adapter
Rack Mount Adapter
Blank Panel (Sold Separatoly)
Rack Mount Adapter
Model Product Name Applicable Model
LR 2751-I Rackmount adapter LV 5380 LR 2752 Rackmount adapter LV 5330 LR 2478 Rackmount adapter 2 units of LV 7330/LT 4400  t in LR 2478 LR 2481 Rackmount adapter One unit of LV 7330 or LT 4400  t in LR 2481 (Not for 2 units) LC 2129 Blank panel LR 2751-I only LC 2130 Blank panel LR 2752 only
LH 2140 Handle LV 5380
There are two kinds of battery adapters for LV 5330 and LV 5380. Please refer to the following table for the difference.
Model No.
Battery Status Display
Installation
Battery Mount IDX (V-Mount)
Ye s Factory
C-EB(XLR) No Customer
Page 53
SPECIFICATION CHANGES:
LEADER ELECTRONICS CORP. reserves the right to discontinue the sale of instruments and/or change the specifications of instruments at any time without responsibility for the incorporation of new features in the instruments already sold.
ORDERING INSTRUCTIONS:
When inquiries or orders re made, please specify operating voltage and AC frequency of the instrument the VOLTAGE of the power supply etc. of the instruments to be used. The instruments can be furnished for AC line voltages of 100, 120, 220, or 240 volts and desighed to operate at the voltages which are with in ±8 % of the rated line voltage.
ENVIRONMENTAL CONDITIONS:
Our products can be used under the following conditions unless stated otherwise. <Operating range>
1.Temperature: 0 to 40 °C
2.Humidity: 85 % RH (without condensation)
POWER REQUIREMENTS:
VA in the  Power Consumption indicates the apparent power.
Models marked with "Green Leaf" meet the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (Directive 2002/95/EC RoHS).
AboutGreen-LeafMark
EUWEEEDirective
LEADER ELECTRONICS CORP.
2-6-33 Tsunashima-Higashi, Kohoku-ku, Yokohama 223-8505, Japan
PHONE:81-45-541-2123
LEADER INSTRUMENTS CORP.(U.S.A) LEADER INSTRUMENTS (H.K.)LTD. LEADER ELECTRONICS CORP.BEIJING OFFICE LEADER INSTRUMENTS (H.K.)LTD.DONGGUAN OFFICE LEADER ELECTRONICS CORP.SHANGHAI OFFICE LEADER ELECTRONICS EUROPEAN OFFICE
AGENT
PHONE:1-714-527-9300 PHONE:852-2721-2503 PHONE:86-10-8511-8606/8607 PHONE:86-769-83829381,83829391 PHONE:86-21-62756905,62759629 PHONE:31-40-2565008
The EU WEEE Directive applies to this product and its accessories. When disposing of this product or its accessories, follow the regulations in your country or region. (WEEE Directive: Waste Electrical and Electronic Equipment)
http://www.leader.co.jp
FAX:81-45-541-2823 FAX:1-714-527-7490 FAX:852-2723-7573 FAX:86-10-8511-8608 FAX:86-769-83819289 FAX:86-21-62751486 FAX:31-40-2565009
12
TSSep.12,2008 08097K Printed in Japan
Loading...