LEADER PHABRIX DOLBY D-D-E ANALYSIS AND GENERATION User Manual

®
PHABRIX®
broadcast excellence
DOLBY D / D+ / E ANALYSIS AND GENERATION
This option is the combination of two options: PHSXOBD-A and PHSXOBD-G. Therefore, it allows the display of Dolby D/D+/E meta data present in a selected audio stream and it can also generate Dolby D/D+/E streams from a wide seection allowing engineers to enter and adjust parameters to check broadcast infrastructure.
Just like the Dolby D/D+/E Analysis option, this combined option can determine if the Dolby packet is timed correctly on the SDI video stream. Also, the Dolby D/D +/E may be monitored from any of the SDI input
embedded audio channel pairs or the AES input.
During use the new start menu window displays both the V Bit information and PCM values along with a snapshot of the Dolby D/D+/E metadata if a Dolby signal is present. Using the Signal Information menu, Dolby D/D+/E will present the full analysis display.
The Dolby D/D+/E metadata screen shown below carries primary information including signal source, Dolby ‘guard band’ timing, CRC errors, program channel and metadata detail. The characters shown in white will only be present when a Dolby D/D+/E signal is introduced into the unit. These include:
Config Frame rate Bit depth Timecode CNC error count
Program Information
Channel(s) Start and End gain Description Dialog level Mix levels
The peak audio levels included in the Dolby D/D+/E meta data packet are displayed on the Audio>Meters page. Select the appropriate set of meters to display Dolby levels which will follow the selected Dolby D/D+/E source.
Dolby E meter display
FEATURE HIGHLIGHTS
DOLBY D/D+/
• 8 CHANNEL VIEW SIMULTANEOUSLY
• DOLBY ‘GUARD BAND’ TIMING
• METADATA VIEW
• CRC ERROR DETECTION
• PROGRAM INFORMATION
• LOGGING
• DOLBY D/D+/E STREAMING SOURCE
• PCM STREAM ON EMBEDDED PAIR
• PCM STREAM ON AES PAIR
• ADJUST START OF FRAME
SET VIDEO LINE NUMBER
• EDIT PROGRAM INFORMATION
• EDIT METADATA
E ANALYSIS
APPLICATIONS
• R&D/TEST DEPARTMENTS
• SYSTEM INTEGRATORS
• SUPPORT ENGINEERS
Dolby E Timing, Program and Metadata display
Note: Dolby E audio will not be decoded.
LEADER INSTRUMENTS CORPORATION
Toll Free 1-800-645-5104 Sales@LeaderAmerica.com
www.LeaderAmerica.com
Fullerton, CA 928311501 E. Orangethorpe Avenue, Suite 140 Tel 1-714-527-9300
AVAILABLE FOR
PHABRIX® SxA
PHABRIX® SxD
PHABRIX® SxE
PHABRIX® TAG (Requires PHSXT-GEN and PHSXOSD)
Represented in the Americas by
®
PHABRIX®
broadcast excellence
DOLBY D / D+ / E ANALYSIS AND GENERATION
This PHSOXBD-AG opion is unique in being the world’s first metadata Dolby generator with editable profiles.
With a selection of Dolby D/D+/E streams to choose from, engineers can quickly enter and adjust parameters to check broadcast infrastructure.
Dolby streams are provided for all program configurations with fixed audio data. Among the Dolby D/D+/E streaming option is the ability to adjust the 'start of frame’ for Dolby D/D+/E packets.
The generated Dolby D/D+/E follows the video generator reference source.
There is also the ability to edit the program configuration and bit depth with fixed audio signal.
the tools included in
The PCM stream can be carried on any embedded or AES pair.
The option can sets the video line number where the internally generated Dolby D/D+/E test stream begins.
Meta data can be edited by the user and stored in memories.
Dolby E generation
Dolby E Generation + Analysis Option (PHSXOB