LDT Littfinski Daten Technik s88 2m Operation Instruction

Littfinski DatenTechnik (LDT)
Operating Instruction
pin-pin plug 6 poles
Please attend to the marking at the pin bar “OUT” and “IN” in accordance to the operation instruction of the feedback module.
for the s88-feedback bus and the PC-light control
Light@Night
from the Digital-Professional-Series!
Kabel s88 2m Part-No.: 000101
Kabel Light@Night 2m Part-No.: 000101
The interference protected twisted connection cable of 2 meter length can be used for:
extending the installation distance of all LDT s88
components or directly to the command station / interface or to each other (for RM-88-N, RM-88-N-O, RM-GB-8-N only).
connecting s88 feedback module from Märklin /
Viessmann directly together at a distance of 2 meter or extend the installation at 2 meter distance each.
connecting the Display and Power Module of the
PC-Light control Light@Night to each other.
This product is not a toy! Not suitable for children under 14 years of age! The kit contains small parts, which should be kept away from children under 3 years of age! Improper use will imply danger of injuring due to sharp edges and tips! Please store this instruction carefully.
CE Part-No.:
24 00 09
Introduction / Safety Information:
You have purchased a connection cable for your digital model railway.
The connection cable is a high quality product which is supplied within the assortment of Littfinski DatenTechnik (LDT).
We are wishing you having a good time using this product. The connection cable comes with 24 month warranty.
Please read the following instructions carefully. Warranty will expire due to damages caused by disregarding the operating instructions. LDT will also not be liable for any consequential damage caused by improper use or installation.
Attention: Please switch off your model railway by disconnecting the transformers from AC-current before starting any installation.
Description for Kabel s88:
The s88 connection cable consists of a 2 meter twisted bus cable with two original s88 pin-socket connectors. At one socket is a pin-pin plug inserted.
Stiftleiste pin plug
If you want to use the s88 connection cable for connection of the feedback module RM-88-N, RM-88-N-O or RM-GB-8-N you have to remove at first the pin-pin plug. Attach now one socket in that position onto the 6-poles pin bar of the feedback module that the single white wire corresponds with white marking at the pin bar.
rosa pink
2 m
rosa pink
BU1
s88-N
OUT IN
OUT
ST1
weiß
ST2
BU2
s88-N
IN
RM-GB-8-N
8-fach Rueckmeldemodul mit Gleisbesetztmeldern 8-fold feedback module with occupancy detectors
Attach the second pin-socket of the bus-cable directly to the command station or to the interface respectively to an other feedback module within the feedback line.
If you want to use the
8 7 6 5 4 3 2 1
s88 connection cable for connecting two Märklin or Viessmann feedback module together please
decoder s 88
9 10 11 12 13 14 15 16
remove first the pin­plug. Insert the pin-socket
weiss white
connectors of the connection cable into the feedback module
Verbindungskabel connection cable
that the cable is directed to the bottom. To assure a constant orientation has the white single wire to be
weiss white
8 7 6 5 4 3 2 1
located into the direction to the middle of the feedback module.
decoder s 88
9 10 11 12 13 14 15 16
The following draft shows an assembled s88 connection cable shown from the left side.
decoder s88
rosa pink
10911
1213141516
rosa pink
1
If you want to extend the s88 bus-connection of
LDT feedback module RM-DEC-88(-O) or RM­GB-8 by 2 meters please
leave the pin-pin plug bar inserted at the plug connector.
The draft shown at the
Digital-Profi werden!
Rückmeldemodul RM-DEC-88
16 Rückmeldeeingänge für den s88-Rückmeldebus.
www.ldt-infocenter.com
Rueckmeldedecoder RM-DEC-88 16-channel feedback modul Rev. 3.0
Peter Littfinski DatenTechnik
L
ittfinski DatenTechnik
rosa
grau
right indicates how to extend a 75cm s88 bus­cable of a feedback module RM-DEC-88 by 2 meters.
Attend to the correct orientation of the bus connectors to assure that the cable colors of the single wires correspond exactly.
Rev. 1.0
märklin
2 m
märklin
D-25492 Heist
gelb
braun
weiss
gruen
ST1
weiss white
Stiftleiste 6 pol.
weiss white
Verbindungskabel connection cable
digital
digital
8765432
ST2
INOUT
Description for Kabel Light@Night:
If you use the PC-light control Light@Night and you do not want to connect the Light-Display respectively Light-Power Module directly onto each other but prefer the installation of the module at a larger distance you can use the Kabel Light@Night with a length of 2 meters.
Insert the pin-plug connector of the connection cable with the pin plug into the 10-poles socket bar of the previous Light-Display respectively Light-Power Module at a position that the white single wire of the connection cable corresponds to the white marking at the Light-Display respectively Light-Power Module.
The other side of the cable has to be connected to the 10-poles pin-plug of the next module. Also on this side it has to be assured that the white single wire of the connection cable corresponds to the white marking at the Light-Display respectively Light-Power Module.
The following draft shows the correct connection of the connection cable. The cable has to show to the top.
Bestellbezeichnung / Order code: Kabel Light@Night xm
45678
GBS-Display / Light-Display
Rev. 1.7
Littfinski DatenTechnik (LDT)
BU1
white weiss
OUT
BU3
26272829303132
25
KL4 KL3 KL2 KL1
KL7
18192021222324
17
9
10111213141516
KL5
KL6
BU2
braun
10...18V~
39383736353433
40
12...24V=
123
ST1
white weiss
IN
gelb
weiss white
xm
weiss white
Stiftleiste (Adapter) pin plug (adapter)
GBS-Display / Light-Display
Rev. 1.7
Littfinski DatenTechnik (LDT)
BU1
white weiss
OUT
26272829303132
25
KL4 KL3 KL2 KL1
KL7
BU3
18192021222324
17
KL5
KL6
braun
10...18V~
39383736353433
40
12...24V=
45678
9
10111213141516
123
Light Interface (LPT)
Rev. 1.0
Littfinski DatenTechnik (LDT)
C2
IC1
C1
ST1
BU1
IC4
white weiss
BU2
IN
gelb
Printer Port LPT
BU2
IC3
IC2
Please pay attention: The first Light-Display respectively Light-Power Module has always to be connected directly to the Light- Interface. Therefore is it only possible to use the connection cable Kabel Light@Night for the connection of the second to the first Module.
Further products from the Digital-Professional-Series:
Kabel s88 0,5m / Kabel Light@Night 0,5m Connection cable (0,5m) for the s88-feedback bus and the PC-Light Control Light@Night.
Kabel s88 1m / Kabel Light@Night 1m Connection cable (1m) for the s88-feedback bus and the PC-Light Control Light@Night.
S-DEC-4 4-fold turnout decoder for four magnet accessories with free programmable decoder addresses and possible external power supply.
SA-DEC-4 4-fold switch-decoder with four bistable relays and free programmable decoder addresses and possible external power supply.
LS-DEC-DB, -DR, -KS, -ÖBB, -SBB, -NS, -NMBS, -BR, -FS, -SJ, -SNCF 4-fold light signal decoder. Light signals switched directly via decoder addresses.
RM-88-N / RM-88-N-O 16-fold feedback modules for the s88-feedback bus. RM-88-N-O with integrated opto coupling.
RM-BG-8-N 8-fold feedback modules with integrated track occupancy detectors for the s88-feedback bus.
HSI-88-(USB) High Speed Interface for the s88-feedback bus. Offers the possibility to create three feedback lines. The feedback reports will be transmitted directly via the command station via the COM- (HSI-88) or the USB-Interface (HSI-88-USB) to the PC.
Littfinski DatenTechnik (LDT)
D-25492 Heist/Germany
Phone: 0049 4122 / 977 381
Fax: 0049 4122 / 977 382
Subject to technical changes and errors. 02/2015 by LDT
Internet: http://www.ldt-infocenter.com
Märklin and Viessmann are registered trademarks
Made in Europe by
Kleiner Ring 9