LDT Littfinski Daten Technik Light-Power-F Operation Instruction

Littfinski DatenTechnik (LDT)
Operating Instruction
Light-Power-Module
Light Control
Light@Night and Light-DEC
Light-Power-F Part-No.: 050062
>> finished module <<
At least one Light-Power-Module and one Light-
Interface (LI-LPT or LI-LAN), will build together the
hardware of the PC-Layout-Light-Control Light@Night.
If a Light-Power-Module will be connected to a Light-DEC-
Basic-Module it will be the basic unit for the Layout Light
Control Light-DEC.
Light-Power-Modules contain 24 light outputs with a
max. current-load of 2.5 Ampere each.
The light effects (e.g. neon lamps, emergency flash lights, light chains, traffic lights and many others) can be assigned individually to each of the 24 outputs.
This product is not a toy! Not suitable for children under 14 years of age! The kit contains small parts, which should be kept away from children under 3! Improper use will imply danger of injuring due to sharp edges and tips! Please store this instruction carefully.
CE Part-No.:
146 40 20
Introduction/Safety instruction:
You have purchased the Light-Power-Module for the Light­Control Light@Night and Light-DEC of the assortment of Littfinski DatenTechnik (LDT). We are wishing you having a good time using this product.
The finished module comes with 24 month warranty.
Please read the following instructions carefully. Warranty will
Connecting Light-Power-Module:
Attention: Before starting the installation switch off the
Connect the Light-Power-Module to the Light-Interface (LI­LPT or LI-LAN), to the Light-DEC-Basic-Module or to already available Light-Power- or Light-Display-Modules via the 10­poles pin-plug-bar.
Take care that there is no offset between pin-bar plug and pin­bar socket. The modules are correct connected if the pc-board will be flush at top and bottom. The picture 1 at the rear side of this instruction shows the correct connection of the modules. Light-Power- and Light-Display-Module do not need to be connected directly to each other. It is as well possible to connect the module via the „Kabel
L@N“ or via the screened and therefore interference protected „Kabel Patch“ (from Light-Power Version 1.2 and Light-Display Version 1.7). Light-Power-Modules contain 24 outputs with a possible max. current load of 2.5 Ampere each. With reason to the possible high current output they are suitable for switching
Suitable for analog and digital model railways.
expire due to damages caused by disregarding the operating instructions. LDT will also not be liable for any consequential damages caused by improper use or installation.
drive voltage by pushing the stop button or disconnect the main supply.
simultaneous many incandescent model railway lamps e.g. switching simultaneously light poles of one street.
Light-Power-Module and Light@Night:
The PC-Layout-Light-Control Light@Night consists of one
Light-Interface (LI-LPT or LI-LAN) and from the PC-Software Version 2.0 of up to 7 Light-Modules with max. 280 light outputs. A mixed application of Light-Power- and Light­Display-Modules is possible. Light-Display-Modules contain 40 outputs each. Each output can cover a maximum load of
0.5 Ampere.
Light-Power-Module and Light-DEC:
Via one Light-DEC-Basic-Module can be up to 160 light control outputs with max. 7 Light-Modules controlled. Therefore is it possible to combine any desired Light-Power- and Light-Display-Module. Light-Display-Modules provide 40 outputs with a possible current load of 0.5 Ampere. If there are more than 160 light outputs required is it possible to install further Light-DEC-Systems.
OUT
IN
Voltage supply to the Light-Power-Modules:
The Light-Power-Modules have to be supplied with 12 to 24 Volt DC. The positive pole of the direct current voltage has to be connected to one of the positive clamps of the Light- Power-Module. As the four clamps of the Light-Power­Module are connected to each other is it unimportant which clamp will be used.
The picture 1 at rear side of this instruction shows how to connect the negative pole of the direct current to all clamps which are marked with “-“. This is required to prevent the destruction of the printed circuit at the Light-Power-Module during high current load.
The used voltage level of the direct current depends to the
incandescent model lamps which shall be connected to Light-Power-Module. The voltage layout of incandescent
model lamps is mostly 16 Volt. Feed the Light-Power-Module either by a direct current
transformer or even better by a switched mode mains power supply (picture 2) which is able to supply a considerable higher current output. Suitable switched mode mains power supply e.g. with 15 Volt can be purchased by Conrad (www.conrad.com) and Reichelt Electronic
(www.reichelt.de). Please consider to implement a sufficient dimension of the
wires in correspondence to the required current load. The table 1 at the rear side of this instruction shows the correlation
between current load, wire cross section and cable length.
Connecting the lights:
The common pole for all lamps is the positive pole. This connection is available within the four positive clamps of the Light-Power-Module. All consumers will be switched to negative via the 24 outputs of the Light-Power-Module. The maximum current at each output can be up to 2.5 Ampere.
12...24V DC
Picture 1: The Light-Power-Module has to get a direct current supply of between 12 and 24 Volt. Each of the 24 outputs can cover a maximum load of 2,5 Ampere.
Picture 2: Switched mode mains power supply are especially
suitable for the supply to the Light-Power-Modules because of the possibility to supply a higher current level. Switched mode mains power supply can be purchased by Conrad- (www.conrad.com) and Reichelt Electronic (www.reichelt.de).
max. 2,5 A max. 2,5 A
16151413121110
BU1
white weiss
BU3
OUT
KL8
KL9 KL10 KL11
17181920212223
987654321
Littfinski DatenTechnik (LDT)
12 ... 24 V DC
KL12
24
Light-Power
Rev. 1.2
BU2
Light Interface (LPT)
Rev. 1.0
Littfinski DatenTechnik (LDT)
C2
KL1 KL2 KL3 KL4 KL5 KL6 KL7
white weiss
IC1
C1
BU1
ST1
IN
Printer Port LPT
BU2
IC4
IC3
IC2
Computer LPT-Schnittstelle (Interface)
- +
Picture 3: Attend to the correct polarity of the DC-current supply at the Light-Power-Modules.
16151413121110
BU1
white weiss
BU3
OUT
KL8
KL9 KL10 KL11
17181920212223
max. 2,5 Amax. 2,5 A
987654321
Littfinski DatenTechnik (LDT)
12 ... 24 V DC
KL12
24
KL1 KL2 KL3 KL4 KL5 KL6 KL7
Light-Power
Rev. 1.2
BU2
white weiss
16151413121110
ST1
BU1
white weiss
BU3
KL8
OUT
IN
KL9 KL10 KL11
17181920212223
max. 2,5 Amax. 2,5 A
987654321
Littfinski DatenTechnik (LDT)
12 ... 24 V DC
KL12
24
KL1 KL2 KL3 KL4 KL5 KL6 KL7
Light-Power
Rev. 1.2
BU2
white weiss
IN
ST1
L N
(AC)
C2
C1
C4
BU1
V ADJ
-V +V
-
+
Computer
LAN-Schnittstelle
DMX
Littfinski DatenTechnik (LDT)
IC5
IC7
C11
RN2
RN1
D1
C6
L1
C9
IC6
C3
IC8
C21
IC2
KL1 KL2 KL3 KL4
ST1
Q1
C20
IC3
8
+5V
(Interface)
PC/
LAN
BU2
C8
KL5
C5
CR1
Taster
Trxcom
C10
IC1
Rev. 1.0
C17
C14 C12
C15
C18 C19
C13C16
Light-LAN (Ethernet Interface)
1234567
GND
- +
12...24V DC
- +
12...24V DC
Picture 4: The Layout-Light-Control Light-DEC consists of one Light-DEC-Basic and of up to 7 Light-Modules. Mixed usage of Light-Display- (right) and Light-Power-Modules (left) is possible.
Optional: Von DCC-Digitalzentrale oder Booster From DCC command station or booster
J
max. 2,5 A max. 2,5 A
16151413121110
987654321
max. 0,5 Ampere
45678
26272829303132
GBS-Display / Light-Display
Rev. 1.8
Littfinski DatenTechnik (LDT)
KL1 KL2 KL3 KL4 KL5 KL6 KL7
25
KL4 KL3 KL2
9
101112131415161819202122232417
123
KL1
D1
braun brown
K
rot red
K J
red brown
KL5
Light-DEC V1.0
IC5
Light-Power
BU1
white weiss
BU3
KL8
OUT
Colored sample connections are available at our Web-Site www.ldt-infocenter.com within the section “Sample Connections”.
KL9 KL10 KL11
17181920212223
24
- +
12...24V DC
Littfinski DatenTechnik (LDT)
12 ... 24 V DC
KL12
Rev. 1.2
ST1
BU1
white weiss
BU2
white weiss
OUT
IN
KL7
BU3
max. 1 Ampere
KL5
KL6
braun
10...18V~
39383736353433
40
12...24V=
braun brown
Vom Modellbahntrafo From transformer
BU2
gelb yellow
gelb
ST1
white weiss
IN
12:15:00 T 300
BU1
Light-DEC-Service
Rev. 1.0
Littfinski DatenTechnik (LDT)
Light-DEC-Basis
Rev. 1.0
Littfinski DatenTechnik (LDT)
S2
S3
KL1 KL2 KL3 KL4
8
+5V
S1
S4
Taster / Button
R1
1234567
GND
Table 1:
current wire cross section
0,5 sq mm
wire cross section
0,75 sq mm
wire cross section
1,5 sq mm
wire cross section
2,5 sq mm
1 Ampere 7,0 meter 10,5 meter 21,0 meter 35 meter 2 Ampere 3,5 meter 5,3 meter 10,5 meter 17,5 meter
3,5 Ampere 2,0 meter 3,0 meter 6,0 meter 10,0 meter
4 Ampere 1,8 meter 2,6 meter 5,3 meter 8,8 meter 5 Ampere 1,4 meter 2,1 meter 4,2 meter 7,0 meter
Littfinski DatenTechnik (LDT)
D-25492 Heist/Germany
Phone: 0049 4122 / 977 381
Fax: 0049 4122 / 977 382
Internet: http://www.ldt-infocenter.com
Subject to technical changes and errors.
Made in Europe by
Kleiner Ring 9